Experimental Investigation of a Domestic Refrigerator using Nano Lubricants

Similar documents
EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Enhancement of COP using Nanoadditives in Domestic Refrigerator

EXPERIMENTAL ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOREFRIGERANT

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

ENHANCEMENT OF HEAT TRANSFER USING NANO-REFRIGERANT. * Corresponding author s

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Adsorption refrigeration system using waste heat

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

International Journal of Informative & Futuristic Research ISSN (Online):

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

PERFORMANCE STUDIES ON A VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANO-LUBRICANT

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

A performance study of Vapour compression refrigeration system using ZrO2 Nano particle with R134a and R152a

Performance Analysis of VCRS with Nano-Refrigerant

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

中国科技论文在线 Energy Conversion and Management 52 (2011)

Design of LPG Refrigeration System

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Performance Assessment of Water Cooled Condenser Refrigeration System

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

II. OBJECTIVE OF RESEARCH

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Design & Fabrication of Hybrid Cooler

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Design, Manufacturing of Chilled Water System for Process Cooling Application

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Department of MCE, Islamic University of Technology 2. Abstract

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

IGCSE PHYSICS GRADE 11 TERM 1 ASSESSMENT BOOKLET

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Experimentation of Heat Pipe Used In Nano-Fluids

Performance of an Improved Household Refrigerator/Freezer

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

R-407A R-448A R-449A

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

CHAPTER 1 INTRODUCTION

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Sarthak Thakar, 2 R.P.Prajapati 1

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Experimental Investigations of Heat Pump for Domestic and Light Commercial Market.

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Oyelami S., Bolaji B. O.

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

PERFORMANCE INVESTIGATION AND EXERGY ANALYSIS OF VCRS OPERATED USING R600a REFRIGERANT AND NANOADDITIVE COMPRESSOR OIL.

Waghmare Tushar Ramrao, D.S.Nakate

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Fabrication of Hot and Cold Water Dispenser

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Transcription:

Research Inventy: International Journal of Engineering And Science Vol.6, Issue 9 (September 2017), PP -14-25 Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com Experimental Investigation of a Domestic Refrigerator using Nano Lubricants Aravind M.S.*, Betson Jose*, Dinay K.P.*, Jaison Elias*, Praveen Raj**, Sreejith K.** *(UG Scholars, Department of Mechanical Engineering, Jyothi Engineering College, Thrissur, Kerala, India) ** (Assistant Professors, Department of Mechanical Engineering, Jyothi Engineering College, Thrissur, India) Corresponding Author: Aravind M.S ABSTRACT: Nanoparticles have attracted great attention in different fields as they show unique properties which can t be attained by conventional macroscopic materials. Low cost additives like nanoparticles play a vital role in modern lubricants. It improves the performance and life of machines by reducing frictional work, wear and prevents failure of its components. In the situations of high thermal loading and high heat flux nanofluids with stabilized nanoparticles emerge as a key for efficient heat transfer. Here a performance analysis was conducted on a hermetically sealed compressor in a domestic refrigeration system working with conventional POE oil lubricant. the POE oil is replaced by SUNISO3GS mineral oil. Nano lubricant samples of POE+ silver nanoparticles oil mixture, POE +tin nanoparticles oil mixture, POE +nickel nanoparticles oil mixtures SUNISO3GS+ silver nanoparticles oil mixture, SUNISO3GS +tin nanoparticles oil mixture, SUNISO3GS +nickel nanoparticles oil mixtures are made. The COP, freezing capacity, power consumption, dome temperature, flash and fire point are measured in all cases and studied. Compressor working with nanofluid as lubricant shows lower power consumption. Heat transfer rate was also found to be higher by the use of nanofluids. The viscosity of mineral oil and nanofluid were measured and are compared. From this study, it was found that use of nanoparticles as additives is economical and aids in better performance compared to mineral oil lubricant. Keywords: Compressor, Dome, Nanolubricant, Refrigerator, Thermometer, Ultrasonic Agitator --------------------------------------------------------------------------------------------------------------------------- Date of Submission: 17-10-2017 Date of acceptance: 31-10-2017 --------------------------------------------------------------------------------------------------------------------------- I. INTRODUCTION Refrigeration is the technology which makes a major contribution to humanity in many ways including food preservation, control of indoor air quality, gas liquefaction, industrial process control, storage and transport of food and drinks and computer cooling. Without refrigeration, modern life is impossible. IIR (Indian Institute for Refrigeration) has estimated that about 15% of all electricity produced worldwide is used for refrigeration and air-conditioning processes of various kinds. Inefficient use of energy is waste of valuable resource and it leads to global warming. So, to protect the environment and to find the solution for the energy crisis it is essential to develop techno economical viable systems. The aim of this work is to experimentally investigate the performance of a domestic refrigerator using nano lubricants. The experiment is done using R134a as the refrigerant. Experimental study on the system is done at various load conditions. The objective is to compare the performance of a nano lubricant at various load conditions. The household refrigerator is converted to the experimental setup with suitable modifications and is properly instrumented with various measuring instruments to note down the various system variables. II. EXPERIMENTAL SETUP Following are some of the important requirements and parameters taken for the system design: Refrigerant inlet temperature = 380K Refrigerant exit temperature = 310K Condenser load (QC) = 700W Outer diameter of water tube = 1.47e -2 m Inner diameter of water tube = 1.27e -2 m Outer diameter of refrigerant tube =0.835e -2 m Inner diameter of refrigerant tube = 0.635e -2 m Density of refrigerant = 1154.90 kg/m 3 14

Viscosity of refrigerant = 182.50e-6 Ns/m 2 Specific heat of refrigerant = 1104 J/kg Thermal conductivity of refrigerant = 0.0759 W/mK Density of water = 993.38 kg/m 3 Viscosity of water = 693.54e -6 Ns/m 2 Specific heat of water = 4179.2 J/kg Thermal conductivity of water = 0.62609 W/mK Inside area of the refrigerant tube = 3.17e -5 m 2 III. SPECIFICATION OF THE SYSTEM Model - Godrej Capacity - 165litres Power - 500W Refrigerant - R134a Maximum Current - 1A Maximum Voltage - 220V Refrigerant mass - 140g Condenser type - Air Cooled Compressor type - Hermetic Expansion device - Capillary tube Length of air-cooled condenser - 12m Length of the WHRS - 7m Diameter of water tube - ½ inch Diameter of refrigerant tube - ¼ inch Material - Copper IV. MEASURING INSTRUMENTS As the measurement of variables affect the test results, care is taken to choose the best instrument at our premises. 1. Pressure Gauge Fig.1 Pressure Gauges The pressure gauges used in this rig is of Bourdon tube type pressure gauges. Using copper tubes, tapings are taken from various points and the gauges are fixed on the panel board. For the high-pressure side, gauge with maximum pressure of 35Kg/cm2is used and at low-pressure side, gauge with maximum pressure of 17.5Kg/ cm 2 is used. Number of gauges - 2 Number of high pressure gauge - 1 Number of low pressure gauge - 1 Range of high pressure gauge - 0 to 35 kg/cm 2 Range of low pressure gauge - 0 to 17.5 kg/cm 2 15

2. Digital Energy meter Fig.2 Energy Meter In the experimental setup single phase digital energy meter is used for measuring the power input to the compressor. Energy meter constant - 3200 Imp/kWh Maximum current - 5-20 A Maximum voltage - 240 V ±25% Frequency - 50Hz± 10% 3. Stop Watch A stopwatch is a handheld timepiece designed to measure the amount of time elapsed from a particular time when activated to when the piece is deactivated. Two buttons on the case traditionally control the timing functions. Pressing the top button starts the timer running, and pressing the button a second time stops it, leaving the elapsed time displayed. A press of the second button then resets the stopwatch to zero. The second button is also used to record split times or lap times. When the split time button is pressed while the watch is running, the display freezes, allowing the elapsed time to that point to be read, but the watch mechanism continues running to record total elapsed time. Pressing the split button a second time allows the watch to resume display of total time. 4. Digital Thermometer Fig.3 Stop Watch Fig.4 Digital Thermometer 16

Digital thermometers are the most commonly used temperature measuring instruments. They are easier to read than glass thermometers, generally more accurate than the older dial-type thermometers based on bimetal coils, have a great range of specialized uses and applications and tend to have a much quicker responsetime. Temperature measuring range : 10oC ~ +100oC Accuracy : ±1oC (10oC ~ +100oC) Resolution : 0.1 o C Product size : 55.5mm x 42.5 mm x 16 mm Sensors : NTC sensors Temperature : 0 o C ~ 60 o C Relative humidity : 20% ~ 85% RH Power : one button battery (LR44, 1.5V) 5. Measuring Jar Measuring jar is used to measure the volume flow rate. It is usually made of glass or plastic. Measuring jar are graduated ones that help us to measure the volume flow rate accurately and precisely. 6. Measuring Tank A graduated tank or measuring tank is a piece of laboratory equipment used to measure the volume of a liquid with respect to time. Graduated tanks are generally more accurate and precise than laboratory flasks and beakers. However, they are less accurate and precise than volumetric glassware, such as a volumetric flask or volumetric pipette. For these reasons, graduated tanks should not be used to perform volumetric analysis. Graduated tanks are sometimes used to indirectly measure the volume of a solid by measuring the displacement of a liquid. V. FABRICATION Few types of fabrication methods are done on the machine. They are: Bending, Flaring and Brazing. Also, further operations are cleaning and assembling Bending is the operation used to make the waste heat recovery system. Bending of the copper tube is done using spring bender. Flaring is the process which is used to increase the diameter of the copper tube in order to fix the valves properly using flaring tool. Brazing is a metal joining process whereby a filler material is heated above melting point and distributed between two or more closely fitting parts by capillary action. This is done in order to prevent leakage. Gas filling is the operation of filling required amount of R134a refrigerant into the system. Cleaning is the operation to clean the all machined parts without dust and chip formals. By meaning, the parts they are brightened and good looking. Assembling is the operation, it deals with the assembling of various parts produced by above operations. Charging of refrigerant in the system includes: Before charging the refrigerant, pressure test is conducted to make it leak-proof. Nitrogen gas is charged into the system and pressure is build up to 200 psi and the system is checked for leaks at the joints using soap solution. If there is no leak, the system is then evacuated using a vacuum pump. The system can be charged with refrigerant through the high or low sides. When the charging is done through the high side, the refrigerant is introduced in liquid form and when the charging is done through the low side, the refrigerant should be added in vapour form in order to prevent the possible damage to the compressor. Normally it is convenient to add the refrigerant through the low side on small units. In this experiment setup R134a is charged into the system through the suction valve of the compressor until (i) electrical current taken by the compressor during the compression process will not exceed the rated current of the compressor (measured by using multimeter connected to the current supply wires of compressor) (ii) Suction and discharge pressure never exceed over the rated compressor pressure. It is advisable to weigh the container before and after charging so that the amount of refrigerant added to the system can be noted down. This information is often helpful during further charging. The system is fully evacuated and charged as follows: >Connect the charging line to the suction valve gauge port. >Connect the other end of the charging line to the refrigerant cylinder. >Open the cylinder slightly and loosen the flare nut at the compressor end. Air will be removed by this operation. Tighten the nut when sound of escaping gas is heard. >Turn the suction valve, thus drawing the gas directly from the cylinder by the compressor. >Start the compressor to draw the required amount of refrigerant. Make sure that the suction pressure should not exceed the rated value. >Close the cylinder valve and allow the compressor to run for sufficient time. >Stop the compressor and back seat the suction valve. 17

VI. EXPERIMENTAL SETUP The experimental test rig connected with suction and delivery pressure gauges and energy meter. Fig.5 Refrigerator connected with pressure gauges and energy meter 1. Silver Nanoparticle VII. NANOPARTICLES Fig.6 Silver Nanoparticle Silver nanoparticles have unique optical, electrical, and thermal properties and are being incorporated into products that range from photovoltaics to biological and chemical sensors. Examples include conductive inks, pastes and fillers which utilize silver nanoparticles for their high electrical conductivity, stability, and low sintering temperatures. Additional applications include molecular diagnostics and photonic devices, which take advantage of the novel optical properties of these nanomaterials. An increasingly common application is the use of silver nanoparticles for antimicrobial coatings, and many textiles, keyboards, wound dressings, and biomedical devices now contain silver nanoparticles that continuously release a low level of silver ions to provide protection against bacteria. 18

2. Nickel Nanoparticle Fig.7 Nickel Nanoparticle Nickel (Ni) Nanoparticles, nanodots or nanopowder are black spherical high surface area particles. Nanoscale Nickel Particles are typically 10-40 nanometers (nm) with specific surface area (SSA) in the 30-50 m2/g range and also available in with an average particle size of 50-100 nm range with a specific surface area of approximately 5-10 m2/g. Nano Nickel Particles are also available in passivated and Ultra high purity and high purity and coated and dispersed forms. They are also available as a dispersion through the AE Nano fluid production group. Nano fluids are generally defined as suspended nanoparticles in solution either using surfactant or surface charge technology. Nano fluid dispersion and coating selection technical guidance is also available. Other nanostructures include nano rods, nano whiskers, nano horns, nano pyramids and other nano composites. Surface functionalized nanoparticles allow for the particles to be preferentially adsorbed at the surface interface using chemically bound polymers. 3. Tin Nanoparticle Fig.8 Tin Nanoparticle Nanoparticles research is rapidly growing into an extensive research area. This is due to the fact that nanoparticles can be easily altered by varying their chemical environment, shape and size. One of the key benefits of nanoparticles is that their properties differ from bulk material of the same composition. Tin is a malleable post-transition metal that is not easily oxidized in air. It can be coated onto other metals to prevent corrosion. Tin nanoparticles have high surface activity, large specific surface area, good dispersion performance and uniform particle size. Tin nanoparticles dispersed in lubricating oil can be used as multi-purpose oil additives, which have the potential to reduce friction and wear in automobile engines. VIII. COMPRESSOR OILS 1. Sunizo 3GS Oil SUNISO GS Oils are miscible well with HCFC and CFC refrigerants such as R-22, R-502 and R-12 while featuring excellent stability and giving long trouble-free service life in the refrigeration systems using above refrigerants. In addition, SUNISO GS Oils also perform excellently with natural refrigerants such as R-717, R-600a and R- 290. 19

Fig.9 Sunizo 3GS Oil SUNISO GS Oils are refined from specially selected naphthenic crude oils by special method assuring excellent lubricity and other properties. SUNISO GS Oils are approved by all major air-conditioner, refrigerator, freezer, car air-conditioner manufacturers in the world. Chemical name: Refined Petroleum Oil. 2. Polyolester Oil POE oils are a family of synthetic lubricants. Unlike natural mineral oils, POE oils are completely waxfree and are the best choice of lubricants for use with the new generation of chlorine-free HFC refrigerants, such as R-410A. This is because they provide superior lubrication, offer better thermal stability, and are more miscible in HFC refrigerants than mineral oils. POE oils are also highly biodegradable. IX. PREPARATION OF NANOLUBRICANTS Mass concentration of nanoparticles in nanolubricants is 0.06 percentage, calculations shows that the silver nanoparticles to be taken is 0.6845 g, nickel nanoparticle is 0.5885 g, and tin nanoparticle is 0.4865 g. Beakers used are thoroughly cleaned with hexane. Measured 1000 g of suniso mineral oil and taken into the beakers and added measured quantity of nanoparticles. Beakers were then placed in digital ultrasonic agitator and kept for 3 hours in there so that the oil and nanoparticle will be mixed thoroughly. The oil is then taken away into storage cans. Continued the above steps for 3 different types of nanoparticles and repeated the process with changing the suniso mineral oil with POE oil. X. ANALYSIS AND RESULTS 1. COP Analysis The coefficient of performance (COP) of a domestic refrigerator can be found out calculating the rate of heat removal from the refrigerated space and the work done by the compressor. Rate of heat removal: Q = m x C p x (t 1 -t 2 ) / t m m = Mass of water in the reservoir C p = Specific heat of water in J/kgK t 1 and t 2 =Initial and final temperature of water t m = Total time the system runs Power input: W = N x 3600/ T m x K N= Number of blinks of energy meter T m =Time for blinks of energy meter K=Impedence constant COP=Q/W Procedure: 1. Run the refrigerator for some time 2. Fill water in a steel vessel of known volume, place the vessel inside the refrigerator. 3. Note down initial temperature and time at which experiment is started 20

4. Run the unit for an hour and note down the total time, temperature and the pressure readings. 5. Perform the suitable calculations for finding the actual COP 6. Determine the specific enthalpy, h at each of the four states using the R134 a refrigerant tables. 7. Determine the theoretical coefficient of performance of the refrigerator 8. Compare the actual and theoretical COP. Sample calculations: Q = m x C p x (t 1 -t 2 ) / t m Q = 4.77836 x 4187 x (30.2-28.2) /3600 Q = 38.9025 watt W = N x 3600/ T m x K Tm =11.2 seconds W = 1 x 3600 / 11.2 x 312000 W = 100.466 watt COP = Q/W COP = 38.9025/100.446 = 0.3872 Fig.10 Experimental Readings Fig.11 COP Graph 2. Viscosity Analysis Viscosity is the property of a fluid that determines its resistance to flow. It is an indicator of flow ability of a lubricating oil; the lowest the viscosity, greater the flow ability. It is mainly due to the forces of cohesion between the molecules of lubricating oil. Procedure: 1. Select the appropriate viscometer depending up on the nature of lubricating oil 2. Clean the viscometer cup properly with the help of suitable solvent e.g. CCl4, ether, petroleum spirit or benzene and dry it to remove any traces of solvent. 3. Level the viscometer with the help of leveling screws. 4. Fill the outer bath with water for determining the viscosity at 80 o c and below. 5. Place the ball valve on the jet to close it and pour the test oil into the cup up to the tip of indicator. 21

6. Place a clean dry Kohlrausch flask immediately below and directly in line with discharging jet. 7. Insert a clean thermometer and a stirrer in the cup and cover it with a lid. 8. Heat the water filled in the bath slowly with constant stirring. When the oil in the cup attains a desired temperature, stop the heating. 9. Lift the ball valve and start the stop watch. Oil from the jet flows into the flask. 10. Stop the stop watch when lower meniscus of the oil reaches the 50 ml mark on the neck of receiving flask. 11. Record the time taken for 50 ml of the oil to collect in the flask. 12. Repeat the experiment to get more readings. Viscosity = 0.226 T 195/T, for 34<T<100 Where, T is time taken for 10cc rise of oil. Fig.12 Time taken for 10 cc of rise of oil for different temperatures Fig.13 Viscosity of different oils in different temperatures (viscosity in stokes) Fig.14 Graph showing viscosity of oils at different temperature 3. Flash Point and Fire Point Analysis Flash point is the lowest temperature at which the lubricating oil gives off enough vapors that ignite for a moment when tiny flame is brought near it. 22

Fig.15 Flash and fire point of different oils Fire point is the lowest temperature at which the vapors of the oil burn continuously for at least five seconds when a tiny flame is brought near it. Fig.16 Graph showing the Flash and fire point of different oils 4. Dome Temperature The graph shows the compressor dome temperature for all the 8 oils. The refrigerator is run for 15 hours under constant evaporator load. The decrease in dome temperature may be due to decrease of friction with nanolubricant. Lower the compressor dome temperature, more stable will be the compressor oil and hence increase the life and performance of the refrigeration system. Fig.17 Dome temperatures for different oils Fig.18 Graph showing dome temperature while using different oils 5. Freezing Capacity The graph shows the time required for reducing the cooling load temperature from 30ºC to 18ºC for all the 8 oils. With SUNISO 3GS oil + silver nano particle, the time required to bring the cooling load is least. 23

Fig.19 Graph showing freezing capacity of different oils 6. Power Consumption The histogram shows power consumption of the compressor. From the histogram, it is clear that there is considerable reduction in power consumption when nano lubricants are used. The reduction in power consumption is highest for SUNISO 3GS + silver nano oil. The decrease in compressor work input may be attributed to better lubricity of the nano lubricants. Fig.20 Graph showing power consumption while using different oils XI. CONCLUSION Extensive experimental and theoretical studies have been carried out to evaluate the performance parameters of a vapor compression refrigeration system with POE oil, SUNISO 3GS oil and with different nanolubricants. The dispersion of nanoparticles in the lubricant resulted in overall performance enhancement of compressor. The conclusions derived from the present study are: 1. The coefficient of performance of the refrigeration system also increases by 16.6 % when the conventional POE oil is replaced with SUNISO3GS + silver nanoparticles oil mixture. This is because of the lower power 24

consumption of the compressor that facilitates the increase in COP of the system. 2. Freezing capacity of the refrigeration system is higher with SUNISO 3GS + silver nanoparticles oil mixture compared the system with POE oil. 3. The power consumption of the compressor reduced when the nano lubricant is used instead of conventional POE oil. The reductions in power consumption is because of the reduced friction due to the better performance of the nano lubricant due to the conversion of the sliding friction to rolling friction. 4. The compressor dome temperature is more for POE oil and least with SUNISO 3GS + silver nanoparticles oil mixture. The reduction in compressor dome temperature may be due to decrease of friction with nanolubricant. Lower the compressor dome temperature, more stable will be the compressor oil and hence increase the life and performance of the refrigeration system. 5. There is an increase in flash and fire points because of the improvement in thermal conductivity of the nanolubricants. The cost of nanoparticles is Rs. 500/g but each charging requires only a very low quantity of nanoparticles.hence the use of nano fluids is economically feasible and paves a new path for use as an effective lubricant. ACKNOWLEDGEMENTS This project was supported by the UG section Department of Mechanical Engineering, Jyothi Engineering College, Thrissur-679531, Kerala, India, Asia. REFERENCES Journal Papers: [1]. S.U.S. Choi, 1995 Enhancing thermal Conductivity of fluids with nanoparticles, ASME FED 231,(66), pp. 99 103. [2]. N. Subramani, M. J. Prakash, 2011, Experimental studies on a vapour compression system using nanorefrigerants, International Journal of Engineering, Science and Technology, Vol. 3, pp. 95-102 [3]. Qiu S, Zhou Z, Dong J, Chen G, 2001 Preparation of Ni nanoparticles and evaluation of their tribological performance as potential additives in oils, Transactions of the ASME. J. Tribology,123(3) pp. 441 443 [4]. Y.Y. Wu, W.C. Tsui, T.C. Liu, 2007, Experimental analysis of tribological properties of lubricating oils with nanoparticle additives, Wear 262, pp. 819 825. [5]. Subramani.N, Aswin Mohan, Dr. Jose Prakash.M, 2013, PERFORMANCE STUDIES ON A VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANO-LUBRICANT, International Journal of Innovative Research in Science, Engineering and Technology, [6]. Bi S., Guo K., Liu Z., 2011. Performance of a domestic refrigerator using TiO2R600a nanorefrigerant as working fluid. Energy Conversion and Management, Vol. 52, No. 1, pp. 733-737. 25