REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Similar documents
REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification Report

TFI Report Classification

TFI Report Classification

Reaction to fire classification report No C-rev.1

Reaction to fire classification report No C

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Additional reaction to fire classification report No H

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

CLASSIFICATION REPORT

Your Key to achieving C.E Marking Compliance

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Analysis Report

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

COMMISSION DELEGATED REGULATION (EU) /... of

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

DELTA Classification Report

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

Centexbel. General certification regulations. Construction products

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

DECLARATION OF PERFORMANCE. No EN

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Fire Test Reports for Interpon D Powder Coatings

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

~~oeti. Report VN71 O Classification Report. Reference

EUROPUMP ATEX Guideline Part II

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE. No EN

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

Reaction to fire classification report No B

Test Report No: ICL/H17/7967

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

DECLARATION OF PERFORMANCE. No EN

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

CERTIFICATION MANUAL FOR NF PROGRAMMES MANAGED BY EUROVENT CERTITA CERTIFICATION: GENERAL PROVISIONS

BS EN ISO : 2010

Council Directive 93/68/EEC of 22 July 1993 amending Directives

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 5: BIAXIALLY-ORIENTED PRESSURE PIPE GROUP

The Danish Energy Authority to carry out inspections in June and July 2012

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

DECLARATION OF PERFORMANCE

~,oeti. Report VN Classification Report. Reference

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Construction Products Directive

EUROPEAN TECHNICAL ASSESSMENT

BS EN ISO : 2010

CEN standardization work on refrigerating systems, especially standard EN 378

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

DECLARATION OF PERFORMANCE. No EN

BS 476: Part 6: 1989+A1:2009

Technical Bulletin CE marking: from 1st July 2013

TECHNICAL DOCUMENT. Technical document Relative to veture products.

DECLARATION OF PERFORMANCE

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

BS EN ISO : 2010

DECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK

Report VNLF Test Report

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

Council of the European Union Brussels, 25 October 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

The New Generationn of Firedoors

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

NF EN V2/AC2 DÉCEMBRE Normes en ligne. Pour : CERN. Client : Commande : N T. le : 10/04/2018 à 17:39

HazLoc Essential Guides:

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

European Technical Assessment

COMMISSION DELEGATED DECISION (EU) / of XXX

BCTC CARPET TECHNICAL CENTRE

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 EMERGENCY STOPS

REGULATION FOR THE CE CERTIFICATION ACCORDING TO THE MEDICAL DEVICES DIRECTIVE

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Centrum stavebního inženýrství a.s.

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Construction Products Directive

GNB-CPR Position Paper: Issuance of certificates under CPR

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

TECHNICAL SPECIFICATION AUTOMATIC SINGLE POLE AND THREE POLE CIRCUIT BREAKERS FOR LV SUPPLIES

BS EN : 2001 & IEC :2000

Transcription:

SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to fire REACTION TO FIRE CLASSIFICATION REPORT No. RA140265 ACCORDING TO THE EUROPEAN STANDARD NF EN 135011+A1:2013 ification by the French Government to the European Commission under no 0679 Seule la version française fait foi The French version is legally acceptable Product standards NF EN 14782:2006 Selfsupporting metal sheet for roofing, external cladding and internal lining Product specification and requirements NF EN 14783:2006 Fully supported metal sheet and strip for roofing, external cladding and internal lining Product specification and requirements Owner: Commercial brand(s): Manufacturing unit(s): Brief description: ARCELORMITTAL LIEGE RESEARCH SCRL Boulevard de Colonster B57 4000 LIEGE BELGIUM Granite FARM The manufacturing unit appears in the associated test report Metal sheets (see detailed description in paragraph 2) Date of issue: October 08 th, 2014 The indicated classification does not prejudge the conformity of marketed materials with the samples submitted to the tests and under no circumstances, this document should not be considered as type approval or certification of the product in the sense of the L 11527 article of the consumption s code and of the law dated June 3 rd, 1994. If this report is being issued by email and/or on an electronic medium, only the hard copy of the report signed by CSTB shall prevail in the event of a dispute. The reproduction of this classification report is only authorised in its integral form. It comprises 5 pages.

2/5 Classification report No. RA140265 1. Introduction This classification report defines the classification assigned to the abovementioned product(s) in accordance with the procedures given in the NF EN 135011+A1:2013 standard. 2. Product description Steel sheet coated on the indoor side with the Granite FARM 35 µm coating consisting of two polyester resinbased back coats (15 µm + 20 µm). The steel sheet can be coated on the outdoor side of the coating with: Granite STANDARD consisting of a polyester resinbased primer (5 µm) and a polyester resinbased or Granite HD consisting of a polyester resinbased primer (5 µm) and a polyester resinbased or Granite HDS consisting of a polyester resinbased primer (15 µm) and a polyester resinbased or Granite HDX consisting of polyurethane resinbased primer with chromium VI (30 µm) or without chromium VI (25 µm) and a polyurethane resinbased finish without chromium VI (30 µm). or Granite STANDARD back coats consisting of two polyester resinbased back coats (8 µm + 7 µm) or Granite FARM 35 µm consisting of two polyester resinbased back coats (15 µm + 20 µm). Nominal thickness of the sheet: 0.55 mm. Colours: various (except metal colours for the Granite HDX coating). 3. s reports and tests results in support of this classification 3.1 s reports Name of laboratory Name of sponsor identification report Nos. method CSTB ARCELORMITTAL LIEGE RESEARCH SCRL Boulevard de Colonster B57 4000 LIEGE BELGIUM ES541130313 RA140265 EN ISO 1716 :2002 EN 13823:2002

3/5 Classification report No. RA140265 3.2 s results Results method Product Number of tests Parameters Continuous Mean values Compliance Granite STANDARD 25 µm 3 0.3 26.3 None Granite HD 25 µm 3 0.4 19.3 EN 13823 Granite HDS 35 µm 3 None 0.3 26.6 None Granite HDX 60 µm 3 10.9 9.5 1.4 27.0 None () means: not applicable

4/5 Classification report No. RA140265 3.2 s results (continuation) Results method Product Number of tests Parameters Continuous Mean values Compliance EN 13823 Granite FARM 35 µm 1 0.4 12.8 33.4 None EN ISO 1716 External non substantial component (outdoor side worst case) External non substantial component (indoor side) 3 (per component) PCS (MJ/m²) 1.9 PCS (MJ/m²) 0.8 Whole product (worst case) PCS (MJ/kg) 0.6 () means: not applicable

5/5 Classification report No. RA140265 4. Classification and direct field of application 4.1 Reference of the classification This classification has been carried out in accordance with clause 11.8.2+A1:2013 of the NF EN 135011 standard. 4.2 Classification Fire behaviour A1 Classification: A1 4.3 Field of application This classification is valid for the following product : The product described in paragraph 2. A nominal thickness of steel sheet 0.55 mm. Various colours (except metal colours for the Granite HDX coating). 5. Limitations The present document does not represent type approval or certification of the product. The classification assigned to the product in this report is appropriate to a declaration of performance by the manufacturer within the context of system 3 attestation of conformity and CE marking under the European Construction Products Regulation (regulation UE no. 305/2011). The manufacturer has made a declaration, which is held on file. This confirms that the products design requires no specific processes, procedures or stages (e.g. no addition of flameretardants, limitation of organic content, or addition of fillers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that system 3 attestation is appropriate. The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested. ChampssurMarne, October 08 th, 2014 The Head of Reaction to Fire unit Gildas CREACH..END OF THE CLASSIFICATION REPORT