DOMESTIC WATER RECORDS

Similar documents
Description of the property and water systems:

Legionnaires Disease Risk Assessment

Legionnaires disease: Technical guidance Part 2: The control of legionella bacteria in hot and cold water systems.

Risk Assessment and Control Measures for Household Hot Water Systems

Statutory Compliance Checklist

installation INSTRUCTIONS

SRSS Cleaning and Sanitisation Procedure

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Electrical Safety Policy and Management System

Team grup. Risk management during the production of mineral water. Presentation at the 3 rd SAFOODNET seminar. Urban Wiik.

Legionella Policy and Procedure

LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

UNIT 5 COLD WATER SUPPLY

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

CUBEflow Thermal Store Tank

SEALED THERMAL STORE

Thermostatic bar mixer valve with adjustable head Installation guide

Property Health and Safety Compliance at Housing and Education Centres

THERMflow Thermal Store Cylinders

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Corporate. Laundry SOP. Document Control Summary

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

Infra Red Thermostatic Wall Mixer

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Please take time to carefully read through these guidelines before using your Kamco pump.

Water Supply (Water Fittings) Regulations 1999

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Salt Spray Cabinet. Manual. Model Ref.: VF7705 (500 liter) VF7710 (1000 liter)

Please take time to carefully read through these guidelines before using your Kamco pump.

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

Please take time to carefully read through these guidelines before using your Kamco pump.

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

smardy - pure water Reverse osmosis system YR100-A 75 GPD

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Summer Works Scheme 2010

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Support for staff involved in the use of steam cleaning machines. C21/HCQAI Criterion 2 Outcome 8 & 10

CODE OF PRACTICE. No 11 CLEANING OF EQUIPMENT AND PREMISES

Hotflo. Unvented point of use hot water

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

EcoCooler Legionella Risk Assessment Information Pack

F I R E S A F E T Y R E G I S T E R

IN ORDER TO PERFORM THESE TASKS, YOU WILL NEED THREE THINGS:

Assessment Schedule - TS8

Maintenance of Fire Systems

Domestic fire sprinkler systems

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

PREMISES FIRE SAFETY LOGBOOK

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

Installation & Operating Instructions

Installation & Operating Instructions

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

The Professional s Choice

Jetflush 4 Instruction Manual

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

Uniclass L725111:D4 EPIC H32. CI/SfB 4 (53.9) X. thermostatic tap specification manual OPTITHERM

ADVANCE ECB ELECTRIC COMBINATION BOILER

Varsity Concealed Shower System

REG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Inta City Shower Mixing Valve CT20010CP

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

HEALTHCARE SAFETY INSPECTION

WATER COOLER AND VENDING MACHINE MANAGEMENT

Code of Practice Version 2 Metal Detection and X-Ray Systems

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

Intatherm Safe Touch Basin Tap IT1008CP

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SPECIFICATION, INSTALLATION AND OPERATION MANUAL. Heat Lamp Assemblies. Models: W.HLA900, W.HLA1200 & W.HLA1500

PartG. of the building regulations Sanitation, Hot Water and Water Efficiency (formerly Hygiene)

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

FOR INSTALLING AND USING

ADVANCE ELECTRIC THERMAL STORE

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Laboratory Safety Audit

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999

Friwa Compact. Operating instructions EN

Facilities and Estates. Hot Works: Standard Operating Procedure. Document Control Summary

Installation & Operation Manual Models:

EXTINGUISHER MAINTENANCE METHOD STATEMENT.

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Owners Manual For The Rainmaster Water Recycling System

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Zip Domestic ChillTap

AUBREY with MAJOLICA PORTO Operation / Installation manual

Transcription:

DOMESTIC WATER RECORDS LEGIONELLA LOG BOOK RESPONSIBLE SITE STAFF PARSONS HALL INDUSTRIAL ESTATE HIGH STREET IRCHESTER NORTHANTS NN29 7AB TEL: 01933 410066 FAX: 01933 410077 www.beaconwater.co.uk

DOMESTIC WATER RECORDS RECEIPT OF LEGIONELLA LOG BOOK Site This Domestic Services Legionella Log Book has been received by the Holder. Name.. Signature. PARSONS HALL INDUSTRIAL ESTATE HIGH STREET IRCHESTER NORTHANTS NN29 7AB TEL: 01933 410066 FAX: 01933 410077 www.beaconwater.co.uk

DOMESTIC WATER RECORDS RECEIPT OF LEGIONELLA LOG BOOK Site This Domestic Services Legionella Log Book has been received by the Holder. Name.. Signature. PARSONS HALL INDUSTRIAL ESTATE HIGH STREET IRCHESTER NORTHANTS NN29 7AB TEL: 01933 410066 FAX: 01933 410077 www.beaconwater.co.uk

LOG BOOK INDEX 1. Written scheme and Responsibilities 2. List of sample points 3. Weekly shower test 4. Monthly temperature logs (taps, tanks & calorifiers) 5. Fault report forms 6. Quarterly shower cleaning 7. Beacon service sheets, bacteria reports & water sampling guidelines 8. Miscellaneous works 9. Beacon cleaning & disinfection records 10. Annual storage tank inspection report

LEGIONELLA CONTROL WRITTEN SCHEME MONTHLY Record the temperatures at a variety of selected taps from throughout the system that will give representative readings plus sentinel taps. o The hot should reach at least 50 C after 1 minute, if no TMV is fitted o All hot taps with Thermostatic Mixing Valves (TMV) should be checked to verify a safe set point of approximately 43ºC o The cold should be below 20 C after 2 minutes Sentinel taps are defined as the nearest and furthest outlets on the hot and cold water system and should be from around the extremities of the system if the building is large or complex. These should be checked every month and should not be fitted with, or fed by, Thermostatic Mixing Valves. Record the hot and cold water storage temperature; The hot should be at least 60 C, the cold should be below 20 C. QUARTERLY Clean, descale disinfect all shower heads, also disinfect shower hoses if fitted. Purge and record the temperature of the shower mixers The mixed supply should be able to achieve at least 43 C after 1 minute. Take water samples to monitor the bacteria levels in the system. ANNUALLY Inspect the hot and cold water storage and arrange for a clean and disinfection if required ALWAYS REPORT S TO THE SCHEME MANAGER SECTION 1

OPERATING PROCEDURES CONTROL OF LEGIONELLA AREAS OF RESPONSIBILITY Task Hot water tap test Cold water tap test Calorifier test Calorifier blowdown Tank temperature test Clean & chlorination of showers / spray taps Microbiological water samples Inspection of tank(s) Clean & chlorination of tank(s) Disinfection of system(s) Flush unused outlets Maintenance of Records Maintenance & archiving of records Responsibility Beacon / Client Beacon / Client Beacon / Client / Other Beacon / Client Beacon / Client Beacon / Client Beacon / Client Beacon / Client Beacon / Client Beacon / Client Beacon / Client Beacon / Client This responsibility rests with the Client. All tests in compliance with L8 2000 Legionella Code of Practice SECTION 1

SAMPLE LOCATIONS FOR WATER MONITORING SHOWER LOCATION SENTINEL TAPS COLD WATER TANKS HOT WATER CALORIFIERS SECTION 2

SAMPLE LOCATIONS FOR WATER MONITORING SHOWER LOCATION SENTINEL TAPS COLD WATER TANKS HOT WATER CALORIFIERS SECTION 2

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

WEEKLY CHECK OF SHOWER OPERATION LOCATION OK (Y/N) SECTION 3

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE MONITORING (TAPS) LOCATION HOT TEMPERATURE AFTER 1 MIN (Control : 50 C or above) COLD WATER TEMPERATURE AFTER 2 MIN RUNNING (Control : 20 C or below) SECTION 4

MONTHLY TEMPERATURE LOG COLD WATER TANKS AND HOT WATER CALORIFIERS LOCATION / IDENTIFICATION RECORD TEMPERATURE (Cold water tank should be less than 20 C) (Calorifier should be at least 60 C) SECTION 4

MONTHLY TEMPERATURE LOG COLD WATER TANKS AND HOT WATER CALORIFIERS LOCATION / IDENTIFICATION RECORD TEMPERATURE (Cold water tank should be less than 20 C) (Calorifier should be at least 60 C) SECTION 4

MONTHLY TEMPERATURE LOG COLD WATER TANKS AND HOT WATER CALORIFIERS LOCATION / IDENTIFICATION RECORD TEMPERATURE (Cold water tank should be less than 20 C) (Calorifier should be at least 60 C) SECTION 4

MONTHLY TEMPERATURE LOG COLD WATER TANKS AND HOT WATER CALORIFIERS LOCATION / IDENTIFICATION RECORD TEMPERATURE (Cold water tank should be less than 20 C) (Calorifier should be at least 60 C) SECTION 4

3 MONTHLY CLEAN, DESCALE & DISINFECTION OF SHOWER HEADS & HOSES PLUS TEMPERATURE LOG LOCATION CLEAN, DISINFECTION & DESCALE COMPLETED (Y/N) TEMPERATURE LOG (Shower should achieve at least 43 C after 1 minute s running) SECTION 6

3 MONTHLY CLEAN, DESCALE & DISINFECTION OF SHOWER HEADS & HOSES PLUS TEMPERATURE LOG LOCATION CLEAN, DISINFECTION & DESCALE COMPLETED (Y/N) TEMPERATURE LOG (Shower should achieve at least 43 C after 1 minute s running) SECTION 6

3 MONTHLY CLEAN, DESCALE & DISINFECTION OF SHOWER HEADS & HOSES PLUS TEMPERATURE LOG LOCATION CLEAN, DISINFECTION & DESCALE COMPLETED (Y/N) TEMPERATURE LOG (Shower should achieve at least 43 C after 1 minute s running) SECTION 6

3 MONTHLY CLEAN, DESCALE & DISINFECTION OF SHOWER HEADS & HOSES PLUS TEMPERATURE LOG LOCATION CLEAN, DISINFECTION & DESCALE COMPLETED (Y/N) TEMPERATURE LOG (Shower should achieve at least 43 C after 1 minute s running) SECTION 6

GUIDANCE NOTES UNDERSTANDING TOTAL BACTERIA AND LEGIONELLA REPORTS Sample reports are issued without a covering letter but all reports will indicate whether the results are satisfactory or whether remedial action is required. It is important to note the status boxes at the top of the letter. If the satisfactory box is ticked then there is no further action required. If some or all of the results are high then the remedial action required box will be ticked. The attached notes give a general explanation of the various potential results and the appropriate level of response. Unfortunately it is not often a simple pass or fail scenario. NOTE : Legionella counts are per litre, whereas Total Viable Counts are per Millilitre; the Legionella test is therefore one thousand times more sensitive. DOMESTIC SERVICES LEGIONELLA IN SHOWERS AND DOMESTIC DOWN SERVICES If legionella are detected up to a level of 1,000 cfu/l the system should be thermally disinfected and shower heads should be removed and disinfected. Showers should be labelled as out of action until the results of a retest are known. It is also advisable to review and audit the routine control measures. If legionella is detected at 1,000 cfu/l or above the infected systems may be taken out of service, subject to discussion with the scheme manager. They will remain out of order until they have been cleaned, disinfected and retested. It is also essential to survey the system to try to identify the possible source of the infection. All remedial works will be completed at the discretion of the scheme manager. The level of response will be affected by the overall level & number of positive results detected in a batch of sample(s); ie. a low legionella count in all the samples may be as serious as a high count in only one sample. SECTION 7

TOTAL VIABLE COUNTS IN DRINKING AND DOMESTIC WATER Total viable counts refer to an overall count of all the bacteria present in the water sample. This is a count of both harmful and harmless organisms. The recommended levels for drinking water are very precise. The water sample is split and incubated at two different temperatures; the limits are as follows: 1 day @ 37 C less than 10 cfu/ml 3 days @ 22 C less than 100 cfu/ml Ideally, the water in the domestic down services also conforms to the above limits. However, in view of the fact that domestic down service water (basin taps, showers, etc) are not intended for drinking there is more leeway on the interpretation of the results; guidance as per Appendix 1. OTHER PATHOGENS The following organisms should always be absent from drinking and domestic water. Pseudomonas spp. / aeruginosa Faecal Enterococci / Streptococci Coliforms E. Coli If these organisms are detected the system should be cleaned and disinfected as soon as possible and the source of the infection investigated. SECTION 7

APPENDIX 1: DOMESTIC AND DRINKING WATER SERVICES TOTAL VIABLE COUNTS: RECOMMENDED LEVELS (22 C COUNTS) DOMESTIC SERVICES (incl Showers) <1 100 2 day count <1 1,000 cfu/ml 3 day count Acceptable 100 or above 2 day count 1,000 or above 3 day count Remedial action required DRINKING WATER <1 10 2 day count <1 100 cfu/ml 3 day count Acceptable 10 or above 2 day count 100 or above 3 day count Remedial action required * cfu = colony forming unit or the number of viable (live and able to multiply) bacteria in the sample KEY TO TVC RESULTS DRINKING WATER TVC up to 100 cfu/ml @ 22ºC, 3 days up to 10 cfu/ml @ 37 C, 2 days TVC 100-500 cfu/ml @ 22ºC, 3 days 10-50 cfu/ml @ 37 C, 2 days Acceptable. Slightly high but not excessive. Verify that water temperatures are correct. TVC 500-2000 cfu/ml @ 22ºC, 3 days 50-200 cfu/ml @ 37 C, 2 days TVC 2000 cfu/ml and above @ 22ºC, 3 days 200 cfu/ml and above @ 37ºC, 2 days TVC too high; flush the outlet thoroughly and clean if inspection shows it to be dirty. Verify that water temperatures are correct. TVC excessive; clean and disinfect the outlet as soon as possible. A system disinfection may also be required. Verify that water temperatures are correct. HOT WATER (BASIN) COLD WATER (BASIN) MIXED SUPPLY (BASIN) MIXED SUPPLY (SHOWER) HOT WATER STORAGE COLD WATER STORAGE TVC up to 1000 cfu/ml @ 22ºC, 3 days 100 cfu/ml @ 37 C, 2 days TVC 1000-5000 cfu/ml @ 22ºC, 3 days 100-500 cfu/ml @37 C, 2 days TVC 5000 cfu/ml and above @ 22ºC, 3 days 500 cfu/ml and above @ 37 C, 2 days Acceptable. Slightly high; we would recommend flushing the outlets and checking for any debris in spray plates or shower heads. Verify that water temperatures are correct. TVC excessive; definitely clean and disinfect outlets and/or shower heads and flush thoroughly. Verify that water temperatures are correct. These levels are very much for guidance and should be viewed in context. SECTION 7

WATER SAMPLING PROCEDURE Work Instruction 1. Subject Bacteriological sampling 2. Scope The collection of samples for further laboratory analysis 3. Management Directive Procedure to be performed in accordance with this document 4. Method 4.1 Sample bottles are supplied by the testing laboratory and are obtained via the office. 4.2 When samples have been collected they are to be processed as soon as possible, and if necessary kept in a refrigerator until ready for dispatch. 4.3 (Where possible Legionella samples should not be refrigerated as degradation is liable to occur) 4.4 Do not keep cold and hot samples in close proximity to each other after sampling 4.5 Ensure that each sample is identified with the information provided by the Office when checking in the sample 4.6 Avoid handling the bottle by the cap or neck prior to sampling Sampling from Taps (Hot & Cold) 4.7 Open the tap and run at moderate flow for 2 minutes; fill the bottle directly from the flow Sampling from Tanks 4.8 If sample taps available follow step 4.7. If no tap available sample tank from point furthest from ball valve. Immerse bottle (cap on) as far as possible collect sample and recap still underwater. Sampling from Softeners 4.9 Sample from the bib tap or the first available outlet by opening fully to fill the sample bottle. ** Further advice is available in BS7592:1992 5.0 Responsibilities 5.1 The person carrying out sampling is responsible for the correct procedure SECTION 7

MISCELLANEOUS WORK SHEET WORK CARRIED OUT COMPANY SECTION 8

MISCELLANEOUS WORK SHEET WORK CARRIED OUT COMPANY SECTION 8

MISCELLANEOUS WORK SHEET WORK CARRIED OUT COMPANY SECTION 8

MISCELLANEOUS WORK SHEET WORK CARRIED OUT COMPANY SECTION 8

RISK ASSESSMENT DISINFECTION AND CLEANOUT OF WATER STORAGE TANKS 1. IDENTIFICATION OF HAZARDS a. Lifting injury b. Injury from falling c. Injury from chemical spillage d. Hazard caused by unnecessary production of aerosol e. Injury from faulty equipment f. Inadequate ventilation 2. SUSCEPTIBLE PERSONS a. The Service Provider personnel, risk category 1a, 1b, 1c, 1d, 1e, 1f b. Site personnel, risk category 1c, 1d 3. RISK EVALUATION CATEGORY 2a All personnel are suitably trained to complete cleaning and disinfection works in accordance with the Health & Safety at Work Act (1974). They will also follow relevant legislative guidelines and internal quality procedures to ensure safe working. Appropriate PPE will be worn as required. All equipment to be PAT tested (as applicable) and adequately maintained. The level of risk for items 1a, 1b, 1c, 1d, 1e and 1f may be considered as medium. CATEGORY 2b Suitable precautions will be taken to minimise aerosol product (item 1d) Also, site personnel are not permitted within the working area. The overall level of risk may be considered as low. 4. SAFE SYSTEM OF WORK It is mandatory that personnel conduct all works in accordance with the aforementioned statements: All PPE to be worn All ladders/scaffold to be secure All chemicals to be handled correctly All heavy items to be lifted correctly Aerosol production to be minimised All equipment maintenance schedules to be up to date SECTION 9

PROCEDURE 1. Subject Sterilisation of Water Storage Tanks by spraying with Chlorine Dioxide or Chlorine solution 1 Warning notices are to be displayed on all relevant control valves. 2 Ensure that all site staff are aware of the procedure is to start. 3 Isolate the Tank. 4 Drain and visually inspect. 5 Ensure there is satisfactory access and ventilation. Use protective equipment and breathing apparatus as appropriate. 6 Prepare a 20ppm solution of Chlorine Dioxide or 50ppm of Chlorine. 7 Sluice the Tank down with fresh water and remove any debris. 8 Spray the internal surface of the tank with 20ppm Chlorine Dioxide or 50ppm Chlorine. Repeat every 15 minutes for 2 hours. 9 Neutralise with CN65 10 All warning notices are then to be removed. 11 A Sterilisation Method Statement Worksheet must be completed, signed by the client s representative and filed in the Log Book. The blue copy is to be returned to Head Office for issue of the Certificate. SECTION 9

PROCEDURE 1. Subject Sterilisation of Mains & Tank Fed Down Services Warning notices are to be displayed at every outlet on the system and on all relevant control valves. Ensure that all site staff are aware of the procedure is to start The entire mains and drinking water system is to be sterilised by injecting sterilant into the pipe. Whilst Sterilant is being injected all service outlets are to be checked until a level of 20ppm Chlorine Dioxide, or 50ppm Chlorine, is reached. This operation is to be carried out without risk of contamination to the authority mains or where applicable to the existing system if new installation is involved. The entire system shall be left fully charged for a period of 1 hour with a reserve of not less than 20ppm Chlorine Dioxide or 50ppm Chlorine. All cistern lids, tank covers etc. must be in position throughout this time. A test of the reserve should be carried out at the end of the time period to ensure 12ppm Chlorine Dioxide, or 30ppm Chlorine as a minimum reserve. If reserve is too low the procedure should be repeated. The entire system should then be flushed to remove all sanitiser. Down Services All storage tanks are to be inspected and any debris removed. All tanks, calorifiers and hot and cold distribution services (including pumped systems if applicable) are to be thoroughly flushed to remove any detritus. The tanks should then be refilled as required and Chlorine shall be added to achieve 50ppm, or Chlorine Dioxide at 20ppm, using the appropriate test kit. All calorifiers and hot and cold down service outlets are to be run until a chlorine reserve of 50ppm, or Chlorine Dioxide to 20ppm, is achieved and maintained. The entire system is to be left for 1 hour during which time the level of chlorine should be checked to ensure 30ppm minimum, or 12ppm Chlorine Dioxide. Upon successful completion the entire system is to be flushed with fresh water until the sanitiser reserve at all outlets is equal to that of the incoming water. All warning notices are then to be removed. A Sterilisation Method Statement Worksheet must be completed, signed by the client s representative and filed in the Log Book. The blue copy is to be returned to Head Office for issue of the Certificate. SECTION 9

COLD WATER SERVICES WATER TANK INSPECTION FORM COMPANY: SITE: SYSTEM REFERENCE: YEAR: TANK NUMBER COMMENTS SATISFACTORY YES/NO TEMP ºC NATURE OF REMEDIAL ACTION TAKEN ACTION TAKEN Inspection must include: Internal inspection for cleanliness, rust and corrosion, sediment and sludge. Security of lid, vent screen, overflow screen. Any indication of ingress of insects and vermin External cleanliness, eg. pigeons, dust and dirt accumulation on lid and in tank room generally. Condition of insulation. Water leakage. SECTION 10

COLD WATER SERVICES WATER TANK INSPECTION FORM COMPANY: SITE: SYSTEM REFERENCE: YEAR: TANK NUMBER COMMENTS SATISFACTORY YES/NO TEMP ºC NATURE OF REMEDIAL ACTION TAKEN ACTION TAKEN Inspection must include: Internal inspection for cleanliness, rust and corrosion, sediment and sludge. Security of lid, vent screen, overflow screen. Any indication of ingress of insects and vermin External cleanliness, eg. pigeons, dust and dirt accumulation on lid and in tank room generally. Condition of insulation. Water leakage. SECTION 10