Dual Laser InfraRed (IR) Thermometer

Similar documents
High Temperature InfraRed Thermometer with Laser Pointer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Dual Laser InfraRed (IR) Thermometer

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User's Guide. Pinless Moisture Meter. Model MO257

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

IRT2 Dual Laser IR Thermometer - User Guide

Manual PCE-889 pyrometer

R2310. Infrared Thermometer. Instruction Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Precision Infrared Thermometer. Users Manual

Users Manual. Visit us at

MT4 MAX/MT4 MAX + Infrared Thermometer

64 Max IR Thermometer

64 Max IR Thermometer

I/R Thermometer Gun 12:1

Visit us at testo 835 Infrared and contact thermometer

User's Guide. Pinless Moisture Meter. Model MO257

62 MAX/62 MAX + Infrared Thermometer

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

IR D USB INFRA RED THERMOMETER

Infrared Thermometer. Getting Started

62 MAX/62 MAX + Infrared Thermometer

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

USER MANUAL Digital CO Monitor Model CO30

Indoor/Outdoor Temperature Alert

Infrared Thermometer

100 Ft. LASER DISTANCE METER

562/563. Infrared Thermometers

Precision Infrared Thermometer. Users Manual

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

User s Guide. OSXL685 and OSXL689. High Performance Infrared Thermometer. Shop online at

Users Manual. Infrared Thermometer

4-in-1 Humidity, Temperature Airflow and Light Meter

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

USER GUIDE Heat Index Psychrometer

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

4-IN-1 PIN/PAD RH MOISTURE METER

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

62 MAX/62 MAX + Infrared Thermometer. Users Manual

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

62 MAX/62 MAX + Infrared Thermometer

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

OMEGA (MODEL:610LF) OS642F-LS Infrared Thermometer With Laser Marker

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

USER MANUAL USB Multi-Function Datalogger Model RHT35

VX SERIES Wireless Thermostat with Occupancy Sensor

OMEGA. OS643E-LS/OS643E Infrared Thermometer With Laser Sighting

Mobile solutions for extreme tasks. Ex-MX2

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

Humidity Monitor model 01080

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

INSTRUCTION MANUAL P Heating and 1 Cooling

Weather Station models / / 00524

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

User's Guide. CO 2 Monitor. Model CO200

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

MGC Dock User s Manual

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Mold Alert... Operation Manual P0270

RT User Guide. Self-leveling, remote-controlled, simultaneous level and plumb rotational laser system

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Motorised Infrared Optical Beam Smoke Detector. User Guide

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

MicrOTDR. Optical Fault Locator. User Manual

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

RK Carbon Monoxide Transmitter Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

RK / RK Methane Detector Operator s Manual

Thermometer with Probe model 00891A

Owner s Manual. PIR-1 IR Learner

RK-02 Multi Point Detector Operator s Manual

Motorised Infrared Optical Beam Smoke Detector. User Guide

RK-05 Combustible Gas Transmitter Operator s Manual

Transcription:

User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512

Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact temperature readings up to 1832 o F (1000 o C). At 30, built-in dual lasers converge to 1 target spot to insure accurate targeting and temperature measurement. The adjustable emissivity feature allows the IR thermometer to measure the temperature of virtually any surface. Proper use and care of this meter will provide years of reliable service. Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Safety Use extreme caution when the laser pointer is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas 2

Meter Description 1. Dual Laser pointers 2. LCD Display 3. Function Buttons 4. Measurement Trigger 5. Battery and F/C Switch compartment DISPLAY 1. SCAN, measurement in progress 2. HOLD, last measurement locked in display 3. Laser pointer active 4. Power locked ON 5. High limit alarm 6. Low limit alarm 7. C or F temperature units 8. Main temperature display 9. Low battery icon 10. MAX icon 11. Emissivity setting 12. Emissivity icon 13. Max temperature display 3

Operating Instructions Temperature Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, MAX temperature reading, the SCAN icon, the emissivity value, and the unit of measure will appear. 3. Release the Trigger and the reading will hold for approximately 7 seconds (HOLD will appear on the LCD) after which the meter will automatically shut off. The only exception to this is if the LOCK mode is set to ON. Note: Select the temperature units (ºF/ºC) using the switch inside the battery compartment Dual Laser Pointer The dual laser pointers are designed to cross at a distance of 30 (76cm). The spot size at this distance is a 1 diameter and this is the recommended distance to target for most measurements. To turn the lasers on/off: 1. Press and release the Trigger 2. While HOLD is on the display, press the laser button once to turn on the lasers on or off. 3. The laser icon will appear in the LCD when the laser function is enabled. 4. The status of the laser will be stored in memory and will remain as the turn-on condition until changed. 4

MAX (maximum) temperature display The highest reading encountered during a single measurement scan is displayed in the MAX display Backlight 1. Press and release the Trigger 2. While HOLD is on the display, press the backlight button once to turn on the backlight on or off. 3. The backlight will illuminate in the LCD when the feature is enabled. 4. The status of the backlight will be stored in memory and will remain as the turn-on condition until changed. 5. Note: The backlight will shorten the battery life. Only use this feature when required. The MODE button options The MODE button is used to access the Emissivity, Lock, High alarm and Low alarm features of the instrument. 1. Press and release the Trigger 2. While HOLD is on the display, press the MODE button to step through and program the following features. A blinking icon indicates the feature is selected. E= (Emissivity Value) Press the or buttons to change the emissivity value. (Lock mode On/Off) Press the or buttons to turn the lock feature ON or OFF. (High Alarm On/Off) Press the or buttons to turn the High Alarm feature ON or OFF. (High Alarm setting) Press the or buttons to set the high alarm limit value in the main display (Low Alarm On/Off) Press the or buttons to turn the High Alarm feature ON or OFF. (Low Alarm setting) Press the or buttons to set the Low alarm limit value in the main display. 5

High and Low Alarm Feature The meter has a programmable high and low alarm feature. When either alarm point is reached the meter will alert the user via an audible beep and a blinking LCD display icon. The alarm limit is set and the feature is enabled/disabled using the MODE button. The setting is stored and memory and will remain as the turn-on condition until changed. Temperature Units The temperature units can be set to F or C using the switch located in the battery compartment. Lock feature The LOCK feature disables the Auto Power Off feature for the period of use when selected. The feature is useful for long term temperature monitoring and hands free use. The meter will revert to auto power off if the trigger is pressed during a locked scan. Over-range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display dashes in place of a temperature reading. Battery Replacement When the low battery symbol appears on the display, replace the meter s battery (9V). The battery compartment is located behind the panel that surrounds the meter s trigger. Open the compartment by pulling the panel down from the trigger area. Replace the 9V battery and close the battery compartment cover. 6

IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements through transparent surfaces such as glass may not be accurate. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down or side to side motion) until the hot spot is located. Field of View The meter s field of view is 30:1. For example, if the meter is 30 inches from the target (spot), the diameter of the target must be greater than 1 inch. Other distances are shown in the field of view diagram. Measurements should normally be made as close as possible to the device under test. The meter can measure from moderate distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 7

Emissivity and IR Measurement Theory IR Thermometers measure the surface temperature of an object. The thermometer s optics sense emitted, reflected, and transmitted energy. The thermometer s electronics translate the information into a temperature reading which is then displayed on the LCD. The amount of IR energy emitted by an object is proportional to an object's temperature and its ability to emit energy. This ability is known as emissivity and is based upon the material of the object and its surface finish. Emissivity values range from 0.1 for a very reflective object to 1.00 for a flat black finish. For the Model 42515, the emissivity is adjustable from 0.1 to 1.00. Most organic materials and painted or oxidized surfaces have an emissivity factor of 0.95. When in doubt, set the emissivity to 0.95. Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Skin (human) 0.98 Cement 0.96 Leather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Soil 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium Oxides 0.81 Plaster 0.80 to 0.90 Copper Oxides 0.78 Mortar 0.89 to 0.91 Iron Oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 8

Specifications Range -58 to 1832 o F (-50 to 1000 o C) Resolution 0.1 o < 1000 o, 1 o > 1000 o Accuracy -58 F to -10 F(-50 C to -23 C) ±14 F/7 C (Typical) -10 F to 28 F(-23 C to -2 C) ±8 F/4 C 28 F to 200 F (-2 C to 94 C) ±4.5 F/2.5 C 200 F to 400 F (94 C to 204 C) ±(1.0%rdg + 2 F/1 C) 400 F to 800 F (204 C to 426 C) ±(1.5%rdg + 2 F/1 C) 800 F to 1832 F (426 C to 1000 C) ±(3%rdg +2 F/1 C) Note: Accuracy is specified for the following ambient temperature range: 73 to 77 F (23 to 25 C) Emissivity 0.10 to 1.00 adjustable Field of View D/S = Approx. 30:1 ratio (D = distance; S = spot or target) Laser pointer Dual, Class 2 laser < 1mW power; Wavelength is 630 to 670nm IR Spectral response 8 to 14 μm (wavelength) Repeatability ± 0.5% of reading or ± 1.8 o F (1 o C) whichever is greater General Specifications Display Backlit LCD display with function indicators Response time 150ms Over range indication --------- Operating Temperature 32 o F to 122 o F (0 o C to 50 o C) Operating Humidity 10% to 90%RH operating, <80%RH storage. Storage Temperature 14 to 140 o F ( -10 to 60 o C) Power Supply 9V battery Automatic Power Off 7 seconds, with LOCK to disable Weight 5.7 oz. / 163g Dimensions 5.7 x 4 x 1.6 (146 x 104 x 43mm) 9

Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2008 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 10