SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

Similar documents
SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

an ISO 9001:2015 Registered Company

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

MINI SLIMLINE COOL VUY-A VUY-A

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

an ISO 9001:2008 Registered Company MINI SPACE SAVER HEAT /COOL/DEFROST QUZ-A VUZ-A

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

BC BRONCOS AIR CONDITIONING UNIT

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

INSTALLATION INSTRUCTIONS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST EARLY 1955 CHEVROLET PICKUP

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Frost Checklist and Troubleshooting Guide for NDA1402 & NEA1402

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

1 SAFETY REPAIR COMPONENTS FUNCTIONS FAULT DIAGNOSIS X-Cool Side by Side Refrigerator

PrecisionTemp Shower-Mate

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

A/C-HEATER SYSTEM - MANUAL

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Installation Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

CB 8000 AMBIENT AIR CONDITIONED FRESH AIR SUPPLY SYSTEM OPERATOR S MANUAL

Heater with Air Conditioning. E-Series Ford Aeromaster

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

COMPAC GEN II HEAT/COOL VUX-A. an ISO 9001:2008 Registered Company #10 SUCTION HOSE COMPRESSOR #8 DISCHARGE HOSE EVAPORATOR DRIER CONDENSER

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

1998 Expedition/Navigator Workshop Manual

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

SUPER GEN II HEAT/COOL VUX-A. an ISO 9001:2008 Registered Company EVAPORATOR #10 SUCTION HOSE COMPRESSOR #8 DISCHARGE HOSE DRIER CONDENSER

Dishwasher Installation Manual

SERVICE NUMBER: SERV-351

Service Manual Model 3163

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Owner s Guide and Installation Manual

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Hoshizaki America, Inc.

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Installation, Operation, and Maintenance Information

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Heavy Duty Heater / Air Conditioner Model R-8545

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

breeze easytm model # F100-1W

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

52 STRATHMERE CEILING FAN

INSTALLATION INSTRUCTIONS

Installation Instructions

APARTMENT MAINTENANCE SERIES

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

2.4 Cu. Ft. Compact Refrigerator

WAILEA OWNER S MANUAL

51AKS I S O OWNER S MANUAL

User Manual & Operating Instructions

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Installation Instructions

HEATING AND AIR CONDITIONING

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Norcold Repair Guide for Ice Maker

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

51AKB / 51 AKC OWNER S MANUAL

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Installation. Leveling

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Transcription:

148 OLD CONCORD TURNPIKE BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM CONDENSING UNIT LOCATION AND MOUNTING The design of the Sea Frost BD allows placement in an enclosed space such as a cabin locker or sail locker. Intake air should be drawn in from the cabin area to insure the coolest, driest air supply. Standard 4" duct hose may be used. Discharge may need to be vented to allow warm air to escape. Intake ducting from the exterior of the boat may cause damp salt air to be drawn in which might reduce the life of your BD. This will also increase below deck moisture. ALLOW 1.5" CLEARANCE BETWEEN THE CONDENSER (BACK VENT AREA) AND ANY BULKHEAD TO INSURE PROPER AIRFLOW THROUGH THE CONDENSER. 1

An un-ducted unit in a poorly ventilated small space will run hot, lowering the cooling capacity, increasing power consumption, and possibly causing damage by overheating the compressor. Service access and installation requires that the front, left end (inlet) and back (condenser) air outlet be exposed. A duct hose will require 4 inches of clearance past the end of the cabinet. Mount the Sea Frost BD level with the compressor at the bottom. The BD may be platform mounted. Two holes have been drilled through the bottom for screw mounting to a shelf or bulkhead. Extra mount holes may be needed. Be sure to drill carefully. Angle clips can be used. If using the bulkhead mount bracket kit, follow directions supplied with the kit. INSTALLATION REQUIREMENTS FOR CONDENSING UNIT * Never block the air inlet or the outlet. * Provide for driest, coolest air for intake. * Total air duct length for intake should not exceed six feet. * Make sure the installation location is vented to allow warm discharge to escape. * For intake through a finished panel, order black flange grill. Test by checking airflow at the end of the vent to be sure it is unrestricted. Smooth vent hose is best. Do not use plastic dryer vent hose MOUNTING A FREEZER BIN The Sea Frost Freezer Bin mounts with a Wellnut expandable neoprene blind hole fastener. A template or the stainless steel brackets should be used to locate the mounting holes. Drill 1/4" pilot holes then increase them to 1/2". MOUNTING THE EVAPORATOR PLATE The plate should be mounted in the cabinet as high as possible to take advantage of thermal convection. It may be used as a shelf, mounted on the ceiling or any wall. There is no restriction as to position. Standard ice trays may be used for ice making if the plate is used as a shelf. If the plate is wall mounted a vertical ice tray kit is available. Before mounting the plate consider access to the thermostat if it is a built in control. 2

The Sea Frost BD plate mounts with a Wellnut expandable neoprene blind hole fastener. A template or the plate itself should be used to locate the mounting holes. Drill a 3/16" pilot hole. Increase this hole to 3/8". 1. Place Well-nut insert all the way into Pre-drilled hole until flange is firmly against mounting surface. 2. Pass Machine screw through part to be fastened and the white spacer washer. 3. Tighten until snug. INSTALLING REFRIGERANT LINES Two copper lines connect the stainless steel evaporator plate and the compressor. One is 5/16" and the other is 1/8". Run the lines behind any and all parts, which may require service. Avoid heated engine spaces. Do not coil excess tubing in an engine space. Protect the lines from being crushed, snagged or stepped on. The quick connect fittings require a 1 inch diameter clearance hole and are staggered to allow passing through a bulkhead or insulated wall. Keep the plastic cap and shrink wrap protective cover in place until the connections are made. WORK CAREFULLY WITH THE COPPER TUBES TO AVOID PINCHING OR KINKING THE TUBES. ALL BENDS SHOULD BE SMOOTH WITH NO LESS THAN A 2" RADIUS. Support the tubing every 18 inches as necessary using tie wraps fastened with selftapping screws. Insulate at least 3' of the line set as it exits the refrigerator box. Split insulation with and adhesive strip is provided. Seal both sides of the exit holes in the refrigerator box with permagum sealing compound. 3

WARNING: The Sea Frost BD system is shipped pre-charged with refrigerant. This refrigerant is under some pressure. Do not fiddle with the connectors or the service ports. You might get hurt! Wear safety glasses when connecting the compressor fittings. COMPRESSOR CONNECTIONS The connections in the BD system are self-sealing when connecting and disconnecting. It is very important to inspect (and clean if necessary) the surfaces and "o" ring seals before assembly. If dirt, moisture, or grit, is on these connectors the system may be contaminated or the seal may be ruined. Working with one line at a time, remove the heat shrink material and the plastic caps. Do not use a sharp knife that could scratch or score the brass fittings, especially the face of the male threaded parts. A scratch or groove in the face of these will create a leak that can t be fixed. Align the two halves carefully and finger-tighten to avoid cross threading. Start with the larger copper line to the compressor fitting. Then connect the small copper line to the remaining fitting. Assemble and tighten all connections in the same work period. Do not wait a day to get wrenches etc. NOTE: The assembled fittings contain 5 wrench flats. The 5/8 flat next to the large ¾ bell shaped nut is to be backed up and not allowed to turn. Only turn the ¾ part. Use two open-end wrenches to tighten the fittings wrench snug. Then position the 5/8 and ¾ wrenches about 1/8 turn apart. Pull up the ¾ handle as hard as you can to meet the 5/8. See fitting make up data sheet. WIRE SIZE 12-volt installations use AWG #10 wire for distances up to 10-feet for the wire pair, and #8 AWG wire for distances up to 25 feet for the wire pair. Fuse 15 Amps. 24 Volts: The module will self calibrate to the applied voltage and provide proper fan voltage. Fuse 7.5 Amps. If the polarity is reversed, the electronic module will not work. In any application, use the next largest wire if in doubt to prevent a voltage drop. A fuse is preferred over a breaker as it has less potential voltage drop. 4

CONNECTIONS For best performance, the electronic module must always be connected directly to the battery or battery selector switch. Connecting the module through the boat's breaker panel may cause a voltage drop; small wires and multiple connectors create resistance. FOR PROTECTION OF THE INSTALLATION, AN EXTERNAL FUSE MUST BE INSTALLED CLOSE TO THE BATTERY IN THE POWER SUPPLY (+) CABLE. The fuse is not provided. Connect a red wire from 12 or 24 volts positive to the (+) terminal of the module. Connect a black wire from 12 or 24 volts negative to the (-) terminal of the module PCB. Do not operate the BD directly from a DC charger without a battery. Never apply power to any of the other terminals. REFRIGERANT CHARGE This system operates with refrigerant R-134a and is pre charged. The proper charge amount is 5-6 oz. An automatic expansion valve regulates the evaporator pressure. This valve is factory adjusted to maintain a constant evaporator pressure of 1 to 3 psi. Do not remove the heat shrink tubing and plastic cap or turn the knob beneath it. Technicians Note: Charge amount will not affect the evaporator low side pressure. Warning! Do not use refrigerant with any additives, including but not limited to: oil, dye, and leak stop. STANDARD THERMOSTAT WIRING CONNECTIONS Connect the thermostat wires to the T and C terminal rows using the far right side connections. The PCB contains a 1500-ohm resistor, which programs the module to operate the compressor at maximum RPM. There is no polarity requirement regarding the thermostat wires. Either one can connect to either C or C. Standard BD thermostat wires ~ copper and silver. Remote (snowflake panel) thermostat wires ~ red. Electronic thermostat thermometer (version 1) wires ~ green and white Electronic thermostat thermometer (version 2 & 3) cat 5 data cable with RJ 45 connector. Install a 3-amp ATC fuse in the fuse holder on the Module PCB board. The PBC board fuse is required only if using Electronic Thermostat with the RJ-45 jack. 5

STANDARD THERMOSTAT OPERATION The thermostat is attached to the plate. The wires follow the refrigerant lines to the compressor section. Protect these wires from cuts and chafe. The BD thermostat is variable. Turning the knob fully counterclockwise turns the unit "OFF". The fully clockwise setting is the coldest. The thermostat may be adjusted to obtain any temperature desired in the cabinet and the thermostat may be calibrated should the warmest setting be too cold. Built on Thermostat Calibration: This should not be required however adjustment can be made. To calibrate the thermostat remove the upper and lower screws on the stainless steel thermostat cover. Carefully move the stainless steel thermostat cover to reveal the white plastic cover, which is on the thermostat. Underneath the white plastic cover, locate the calibration screw. To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approximately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. OPTIONAL REMOTE THERMOSTAT OPERATION Slide the bulb clip onto the edge of the plate and over the sensing bulb. The sensing bulb must be in excellent thermal contact with the plate. We recommend that the probe be mounted on the plate in the one of the lower mounting positions (A) as shown in the drawing below. This is best because these positions remain colder. 6

For the best operation pull excess thermostat sensing tube into the insulated space. This can be coiled. The SEA FROST BD thermostat is variable. Turning the knob fully counterclockwise turns the unit "OFF". The fully clockwise setting is the coldest. The thermostat may be adjusted to obtain any temperature desired in the cabinet. Remote Thermostat Calibration The thermostat may be calibrated should the warmest setting be too cold. To calibrate the thermostat remove the mounting screws and tip the panel forward. Remove the electrical tape (if necessary) to expose a black adjustment screw about an inch into the case. To lower box temperature, rotate this screw counter clockwise. One full revolution will change the box temperature approximately 6 degrees F. To raise the temperature in the box rotate the screw clockwise. Make small adjustments. Record all adjustments. OPERATION DESCRIPTION Once installed the BD is started by turning the thermostat clockwise from the off position. The BD will run until the plate reaches the set temperature of the thermostat. Turning the thermostat counterclockwise lowers the temperature at which the BD will switch off. The BD will remain off until the plate temperature rises about 15 degrees. The BD is either on or off. It will not cool faster with a colder setting. Set the thermostat in the warmest setting and slowly advance it as the weather changes. The Sea Frost BD is a small system. It is efficient in its electrical conversion of energy to heat movement. By being small it is quiet, compact, has low electrical starting requirements and running power draw, and is able to be air-cooled. It will take some time to cool a warm cabinet. DEFROSTING Excessive frost/ice build up on the plate will reduce the cooling effect by insulating the evaporator plate. Allowing the evaporator plate to warm above freezing is one method of defrosting. Boiling water or a scraper will also work. 7

OPERATION INSPECTION Within a few minutes of starting the Sea Frost BD the tubing in close proximity to the valve mounted on the plate and the valve itself will be noticeably cold. IF AFTER 20 MINUTES OF OPERATION, COOLING IN THIS AREA IS NOT OBSERVED DO NOT CONTINUE TO OPERATE THE SYSTEM. OPERATIONAL INFORMATION VOLTAGE AMP/HR DRAW LOW VOLTAGE CUT OFF WIRE SIZE TO BATTERY SUPPLY FUSE: 12 D.C. or 24 D.C. 4.5 TO 6 @ 12 VOLTS 10.4 VOLTS @ 12 VOLTS 22.8 VOLTS @ 24 VOLTS AWG # 10 TO 10 FEET AWG # 8 MAXIMUM 25 FEET 12-VOLT - 15 AMP STANDARD AUTOMOTIVE 24-VOLT 7.5 AMP STANDARD AUTOMOTIVE SERVICE NOTE: The BD is intended to operate with the compressor cover in place. When operating with a manifold gauge set, be sure to block off the top and front with cardboard and tape to maintain proper airflow to the condenser. 8

TROUBLESHOOTING A light emitting diode (LED) is connected between terminals + and D. In case the electronic unit records an operational error, the diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual number of flashes there will be a delay with no flashes, the sequence for each error recording is repeated every 4 seconds. Flashes will only occur in the fault mode with the system on. See additional trouble shooting information available at www.seafrost.com OPERATIONAL ERRORS SHOWN BY LED Number of Error type flashes 5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot.) 4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm.) 3 Motor start error A. (The system might be overcharged.) Has charge been added? B. Faulty module. C. This fault may also occur when the compressor is trying to start a warm system or on initial start up on a new system. Several attempts and then start up can be normal. Do not let out refrigerant until first contacting Seafrost! 2 Fan over-current cut-out (The fan is defective.) 1 Battery protection cut-out Low Voltage (The voltage is outside the cut-out setting.) 9

1. Electronic unit 2. Battery 3. Fuse (see electrical connections) 4. Main switch (optional) 5. LED for operational errors 6. Fan 7. Thermostat 8. R1- Resister for pre-setting speed (optional) or Jumper for AEO module 9. RJ45 jack for optional Electronic Thermostat. WIRING DIAGRAM NOTE: When using the modular thermostat connection (#9) there are no connections on thermostat terminals (#7). Our Repair Policy Your Sea Frost BD system is manufactured to the highest standards and thoroughly tested. If you experience problems with your system requiring technical service, return it to us freight prepaid. When a system is returned to us we will fix manufacturing defects and failures occurring in normal operation for one year from the date of purchase or from the date of first usage/commissioning at no charge, and return it to you freight prepaid (surface freight) anywhere in the continental United States. Installation damage and damage to the electrical parts will be favorably considered however this damage is not our responsibility. Improper wiring, improper voltage, corrosion, and water damage are not considered manufacturing defects. It is your job to install and maintain your system in a reasonable manner to prevent possible problems. Proper installation and reasonable care will give you many years of excellent operation. Please notify us before returning your system for repair. 10