LCD type GSM &PSTN dual network alarm system user manual(208-8) A main features Welcome you use the LCD display GSM&PSTN alarm system, its main features as follows, 1. 99 alarm zones,93 wireless zones and 6 wired zones 2. Dual network working mode, be adapt to GSM cell network and PSTN landline telephone system at the same time 3. GSM frequency: four band 900/1800/1900/850MHz 4. LCD time and date display, automatical arming and disarming by setting time and date 5. Two way talking ability via GSM network in alarm and remote distance operatrion mode 6. Six autodial alarm phone numbers plus extra six SMS alarm phone numbers 7. Ten alarm messages can be recorded by user himself 8. Two relay output terminals can be operated by user to control alarm related devices 9. Learning code accessories can be easily added or deleted by user 10.Four bit password for keypad protection 11. backup built-in battery for electricity power down use 12 size: 120mm(W)*180mm(L)*42mm(H) 1
B configurations 1. Each standard main unit matched with two remote controllers, one PIR detector,one door sensor,one siren and one power adaptor, the built-in battery can work for 20 hours when extrenal electricty power down, please do not turn on the battery switch before the maun unit normal working to protect the battery life time., when the external power adaptor working on, turn on the battery switch to charge the battery at the same time. 2. The main unit user password is 1234, which is used for keypad setting and remote distance operation,user can modify the password by himself but should keep in mind the new ones. 3. Main unit working voltage: DC9V~12V, working current: idle 30mA, alarm 300mA, external power adaptor input AC voltage: 220V/AC or 110V/AC 4. All the accessories are matched well for the main unit use, the PIR detector should turn on the battery switch, the door sensor should install the battery before use. C use method 1.Prepare a SIM card which must be sure of valid use period, insert the SIM card into the proper position of the main unit, the card s metal side should be in the down direction 2.After inserting the SIM card, plug in the external power adaptor, the main unit begin initializationwork, LCD display INIT--00 00, the GSM signal LED blinking rapid at first, then the GSM signal LED blinking slower after the main unit received the GSM signal, the main unit give out one beep sound, means not received the GSM sound and if three beep sound Plug in the PSTN landline if available. The main unit will dial the PSTN landline at first when alarm taking place, and send SMS out at the same time. If no landline connected with the main unit, it will dial the alarm phone number by GSM network and send SMS at the same time 3. LED display The top LED is power indicator, th middle LED is GSM signal indicator, the third is status indicator, which light up means arming, light off means disaming, rapid blinking means alarm Press the lock button of remote controller to arm the main unit, the status LED light up, Press the unlock button disarming the unit, the status LED light off. 4.Store one group or several group telephone number to receive alarm message, and record alarm memo messages, you can start to test the unit function( detailed operation method showed later) 5.Use remote controller to arm the unit, turn on test the main unit alarm process effect before installation the PIR detector battery switch, install the battery for door sensor, 6.PIR detector is installed on indoor wall with height 2.2m or so, adjust the direction angle to 2
make it perpendicular to people walking direction, maximum response coverage range is 10m. the wireless door sensor s emitter part (with antenna) would be installed on door, and the magnetic bar should be installed on door frame, the two parts should be closed when door closed, and departed to emit signal (LED light up) when door opened. D operation method Arm and disarm Arm by using remote controller Bypass Arm by using remote controller Disarm by using remote controller: Panic alarm by using remote controller: press arm key lock press bypass key lightning press disarm key unlock press panic key bell or speaker Remote controller function description: Arm: press key lock, all detectors will trig alarm when received alarm signal Bypass arm: Disarm: Panic button: press key bypass two times, all other detectors will trig alarm when received alarm signal apart from detectors which is set as bypass type press disarm key unlock, all detectors will not trig alarm when received alarm signal psrt from panic alarm signal panic button on remote controller and main unit keypad will trig alarm in any status 3
Arm and disarm on main unit keypad: Shenzhen SUNSKY Technology Limited Arm: Disarm: Bypass arm: Press arm key on main unit for more than 3 seconds and release Press disarm key on mian unit for more than 3 seconds and release Press bypass key on main unit for more than 3 seconds and release 1. Store telephone numbers for receiving alarm messages Press key store on main unit, input four digit password(initial value is 1234), press key up or dn to select the telephone number group number(value from 1 to 6 total six group number is for auto dial, value from 7 to 12 is total six group is for receiving short message SMS), press key # to confirm, press key backspace to clear old values, input new numbers as you expected, press key # to confirm, press key exit can exit the process. If you need to store another group telephone numbers,then repeated the above process. You can store maximum 12 groups of numbers, and you also can left any group numbers t blank. The alarm process will dial the first six alarm numbers and send short messages SMS to last six group numbers one by one consecutively, if any group numbers is void, it will skip the blank group numbers and report to the next group, the whole alarm process will repeat three times to dial the alarm phone numbers from first to six if no one answer the alarm. The last six numbers can be same or not same as first six groups numbers. At least one group alarm telephone numbers is to be stored into the main unit. 2. Setting ten seconds recording messages Press key rec for more than three seconds, input four bit pasword, Select 1 to record voice: start speaking for less than ten seconds,press exit key to stop recording Select 2 to playback voice: listen voice from the speaker to confirm if it is correct Recording content can be as follows: alarm event from xxx room,xxx floor,xxx building..please handle it immediately 3. Look up alarm history event Press key his,input four bit password, press key up or dn to check most new alarm event records, maximum 99 records. Press key bkspace +four bit password can delete records. 4. receiving alarm when your telephone machine or mobile phone receiving the alarm phone, just connecting the alarm phone and press key on your phone to control the alarm unit as follws: press 1 to monitor voice press 2 to open siren sound press 3 to close siren sound press 4 to arm press 5 to disarm press 6 to talk (in GSM mode) or speak (in landline mode ) press 7 close talking or speaking press 0 playback recording voice press # to exit 4
press 8 to close relay output press 9 to open relay output(relay output current must less than 300mA) 5. remote operation while you are far away from the alarm machine, you can also control the alarm machine by following method: dial the alarm unit phone number, you will hear two beep sound from your phone after six ringback sound auto-connecting on, then input four bit pasword(default value is 1234), if password input wrong, you will hear three beep sound, if password input correct, you will hear two beep sound, then input command code on your phone as follows (same command format as receiving alarm), press 1 to monitor voice press 2 to open siren sound press 3 to close siren sound press 4 to arm press 5 to disarm press 6 to talk (in GSM mode) or speak (in landline mode ) press 7 close talking or speaking press 0 playback recording voice press # to exit press 8 to close relay output press 9 to open relay output(relay output current must less than 300mA) 7.Short message SMS control function Send SMS password+arm to main unit to arm the unit, for example: 1234ARM Send SMS password+disarm to main unit to disarm the unit send SMS password+bypass to main unit to bypass arm the unit Send SMS password+onsiren to main unit to start siren Send SMS password+offsiren to main unit to stop siren Below is more special function setting, it is optional setting for user. Press key set, input four bit password,default value is 1234, then press Then key exit can exit setting process from all below process): Press 1 then press key up dn to select below function # to confirm,(please note press select 1 then press key bkspace to set telephone line cutoff alarm. Press key up dn to select ON,then press # to save line cutoff alarm function. Press key up dn to select OFF,then press # to save closing line cut-off alarm function. For pure GSM network, this function is no use select 2 then press key bkspace, then press key up dn to select ON, press # to save. Press key up dn to select OFF, press # to save closing GSM no signal alarm function. Select 3 to check GSM signal value 5
Press 2 to set siren sound alert when using remote controller arm &disarm, use key up dn to select ON OFF,press # to save it. Default is ON Press 3 to set password protection for arm or disarm by keypad, press up dn to select password protection ON OFF, press # to save settings. Default is ON. Press 4 to set siren acting time, press key bkspace,then input 2 bit time value, range from 00,01,02, 99 Press minutes), then press # to save the value, default is 02 minutes. 5 to set new paswword, press key bkspace, then input four bit new password,press # to save, (note: if user forgot old password, please use super-password 0755 to your new password Press 7 the press up dn to select function Press 8 Select enter into setting process, then setting 1 to set remote distance dial ringback times, press key backspace then input ringback times,press # to confirm, value range from 0~ 12, default is 6 times. Select 2 then press bkspace, press up dn key to select ON or OFF, press # to save it. ON means open external power down alarm, OFF means close external power down alarm. Select 3 then press bkspace, press up dn key to select ON or OFF, press # to save it. ON means open low battery alarm, OFF means close low battery alarm setting alarm delay time and arm delay time Press up or dn to select alarm delay time(alarm) or arm delay time (ARM) Press key bkspace then input time value, time range from 00 to 99 seconds, press # to confirm, press exit to exit the process. Press 9 to set automatical arm or disarm time. There are three group time can be set for each day. Press key up or dn to select one group time arm or disarm, use key set to select open or close the action, when select open the action,press key bkspace to clear old value, then input new time value ( input x day to x day, hour, mintue, for example: input: 1 7 18:30 means from Monday to Sunday 18:30 to start arm or disarm ),press # upon layer menu. Setting content including: start time, end time, etc. to save the time value. Press exit to exit Press 0 to set date, press key bkspace then input new year,month,day,hour,minute.etc, press # to confirm, press exit to exit setting Press * to reset, then press #, input four bit password again, press # to reset the main unit. The reset command will restore all the settings to default value. Setting wireless and wired accessories The wireless accessries like remote controllers, PIR detectors, door sensors in the standard DIY kit are already learned to the main unit and can be used directly. If user need to add extra accessories to the main unit, the extra wireless parts must be learned to the main unit before it can be used normally according to follows steps, 6
Press learn, then input four bit password Input 1 to learn remote controller,input two bit zone number,press # to confirm, press a button on the remote controller to trig wireless signal emitting to finish the learning process Input 2 Note :zone number distribution as follows: Remote controllers: zone from 87 to 99 Wireless detectors: zone from 01 to 80 Wired detectors: zone from 81 to 86 to learn PIR detector, input two bit zone number,press # to confirm, turn on the battery switch to trig wireless signal emitting to finish the learning Input 3 to learn door sensor detector, input two bit zone number,press # to confirm, use the magetic bar close to the door sensor emitter then departed away to trig door sensor to emit wireless signal to main unit Input 4 to learn active wireless IR beam alarm, input two bit zone number,press # to confirm, power on the wireless IR beam and trig its wireless signal to main unit to finish the learning process(note: the IR beam is the detectors to detect people walking passing across the IR beams to trig alarm ) Input 5 to learn wireless gas detector, input two bit zone number,press # to confirm, power on the gas detector and trig the gas detector to emit wireless signal to the main unit to finish the learning Input 6 to learn wireless smoke detector, input two bit zone number,press # to confirm, power on the wireless smoke detector and trig the smoke detector to emit wireless signal to main unit to finish the learning Input 7 setting wireless detectors alarm delay time or delete detectors Input up or dn to select the wireless detector, press set to select the detectors alarm mode: delay alarm / arm delay / emergency(panic) alarm/arm bypass : delete wireless detectors: Input up or dn to select the wireless detector, press bkspace detector, press exit to exit the process then input password to delete the Input 8 setting remote controller emegency alarm sound or delete remote controller Input up or dn to select the remote controller, press set to set panic with sound or panic without soun alarm, delete remote controller: Press bkspace and password to delete the remote controller Input 9 set wired accessories function 7
Input up or dn to select the wired detectors, press bkspace to set ON or OFF, ON means normally open, OFF means normally closed Press set to set the wired detector s trig mode: delay alarm / arm delay / emergency(panic) alarm/arm bypass *****brief command table***** Store alarm telephone number: sto+password+#+ up/dn+bkspace+phone number+# Record ten seconds alarm voice: rec key 3s +password+#+1+speaking Plackback ten seconds voice: rec key 3s +password+#+2 Lockup history event: his+password+#+up/dn Delete histosy event: his+password+#+up/dn+bkspace+password open line cutoff alarm: close line cutoff alarm: set+password+#+1+up/dn+1+bkspace+up/dn( ON ) set+password+#+1+up/dn+1+bkspace+up/dn( OFF ) open arm/disarm siren sound: set+password+#+2+up/dn( ON )+# close arm/disarm siren sound: set+password+#+2+up/dn( OFF )+# open arm/disarm password protection: set+password+#+3+ up/dn( ON )+# close arm/disarm password protection: set+password+#+3+ up/dn( OFF )+# set siren active time length: set new password: set+password+#+4+bkspace+time(0~99s)+# set+old password+#+5+bkspace+new password+# set ringback times: set+password+#+7+up/dn( 1 )+bkspace+ringback times(0~12)+# open external power cutoff alarm: set+password+#+7+up/dn( 2 )+bkspace+ ON +# close external power cutoff alarm: set+password+#+7+up/dn( 2 )+bkspace+ OFF +# open battery low alarm: close battery low alarm: set+password+#+7+up/dn ( 3 )+bkspace+ ON +# set+password+#+7+ up/dn ( 3 )+bkspace+ OFF +# set arm delay time: set alarm delay time: set+password+8+up/dn( arm )+bkspace+time(0~99s)+# set+password+8+up/dn( alarm )+bkspace+time(0~99s)+# set automatic arm: set+password+#+9+up/dn( arm )+set( open or close )+bkspace +time+# set automatic disarm: set+password+#+9+up/dn( disarm )+set( open or close )+bkspace +time+# set date and time: set+password+#+0+bkspace+time+# 8
main unit reset: set+password+#+password+# learn remote controller: learn PIR detector: learn door sensor: learn IR beam: learn gas detector: learn smoke detector: learn+password+#+1+two bit zone number +#+(signal) learn+password+#+2+two bit zone number +#+(signal) learn+password+#+3+two bit zone number +#+(signal) learn+password+#+4+two bit zone number +#+(signal) learn+password+#+5+two bit zone number +#+(signal) learn+password+#+6+two bit zone number +#+(signal) set wireless detector with arm delay time: learn+password+#+7+up/dn+set+arm delay+# set wireless detector with alarm delay time: learn+password+#+7+up/dn+set+alarm delay+# delete wireless detector: learn+password+#+7+up/dn+bkspace+password+# set remote controller as panic with sound: learn+password+#+8+up/dn+set +panic with sound+# set remote controller as panic without sound: learn+password+#+8+up/dn+set Delete remote controller: learn+password+#+8+up/dn+bkspacet+password+# +panic without sound+# Set wired detector as open type: Set wired detector as close type: learn+password+#+9+up/dn+bkspacet+on+# learn+password+#+9+up/dn+bkspacet+off+# Set wired detector as arm delay type: Set wired detector as alarm delay type: Set wired detector as panic type: learn+password+#+9+up/dn+set+arm delay+# learn+password+#+9+up/dn+set+alarm delay+# learn+password+#+9+up/dn+set+panic+# 9