INSPECTION OF COMMERCIAL KITCHEN PLUMBING

Similar documents
Read Only Document Not For Distribution

c. Direct or indirect?

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

PLUMBING INSTALLATIONS

2015 UPC Chapter 8 Indirect Wastes RV

Special Requirements For Health Care Facilities

Frequently Asked Questions

Read Only Document Not For Distribution

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

2016 Plumbing Supplemental Plan Review List

CHAPTER 10 TRAPS AND INTERCEPTORS

Food Service Plan Review Information

Read Only Document Not For Distribution

1 Exam Prep Plumber s Handbook Tabs and Highlights

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014

MATERIALS Traps TRAPS. No. IPC IRC Description

PLUMBING FIXTURES CHAPTER 27

How To Size A Big Dipper Unit

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Structural Guidelines. Food Service Establishments. Retail Food Stores

New Food Service Plan Review Checklist

Yakima Health District 1210 Ahtanum Ridge Drive Union Gap, Washington Phone (509) Fax (509)

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

APPENDIX J ILLUSTRATIONS

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

CHAPTER 5 Water, Plumbing, and Waste

Minimum Requirements for Food Establishments (per the Texas Food Establishment Rules (TFER) 25 TAC 228)

1 Exam Prep Plumbing State Contractors Practice Exam 2

Building Utilities 1 Plumbing and Sanitary Systems

Sanitary Drainage Systems

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 2 DEFINITIONS

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

PLUMBING REQUIREMENTS

Food Establishment Guidelines. Food Service Plan Review

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

PLUMBING FIXTURES Reserved

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

DEFINITIONS CHAPTER 2

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

Level I Chapter 1 Worksheet

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

Number of sides for work space where food preparation occurs. Minimum width between food equipment and walls in work space.

3/12/2018. Cross-Connection Control UF TREEO Conference Cross Connection Survey of High-Hazard Manufacturing Plant.

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

DEFINITIONS CHAPTER 2

All food service facilities must be equipped with the following items for the pre-opening inspection:

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

FOOD ESTABLISHMENT LICENSE APPLICATION Fee Required with Submission of Application

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable

CHAPTER 10 TRAPS AND INTERCEPTORS

DEFINITIONS CHAPTER 2

TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ (609) FAX (609)

System Name. Customer Awareness- Cross Connections and Backflow Prevention

Guide to Starting a Food Business

Matrix of changes for the National Standard Plumbing Code July 2013

TOWNSHIP OF WEST WINDSOR P.O. BOX 38; 271 CLARKSVILLE ROAD WEST WINDSOR, NJ (609) FAX (609)

What Should Be in a Licensed Kitchen?

Chapter 4: Fixtures, Faucets & Fittings:

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434)

DeCA DESIGN CRITERIA HANDBOOK PLUMBING SYSTEMS

PLAN REVIEW CHECKLIST

CHAPTER 2 DEFINITIONS. Back-Siphonage The flowing back of used, Backwater Valve A device installed in a drainage. bathtub.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Definitions UPC Code - Chapter 2 Definitions A-I

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

MINIMUM CONSTRUCTION AND EQUIPMENT REQUIREMENTS FOR FOOD AND BEVERAGE ESTABLISHMENTS

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

GARCIA GALUSKA DESOUSA Consulting Engineers

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

Morgan County Health Department 180 S. Main St., Ste. 252, Martinsville, IN Phone: Fax:

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

STACKS AND STACK VENTS

Food Establishment Plan Review Worksheet

FIXTURES, FAUCETS AND FIXTURE FITTINGS

CONSUMER HEALTH SERVICES PLAN REVIEW PACKET

Page 1 of 16 Restaurant Equipment Quiz

CHAMBERS COUNTY FOOD ESTABLISHMENT PROCEDURES AND REQUIREMENTS PROCEDURES FOR OPENING A FOOD ESTABLISHMENT

GREASE SEPARATION DEVICE SIZING OPTIONS

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

Page 1 of 12 Restaurant Equipment Quiz

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

CHAPTER 9 VENTS SECTION

248 CMR: BOARD OF STATE EXAMINERS OF PLUMBERS AND GAS FITTERS

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

FOOD ESTABLISHMENT INSPECTION REPORT

APPENDIX L ALTERNATE PLUMBING SYSTEMS

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

FOOD ESTABLISHMENT PLAN REVIEW APPLICATION TO BE COMPLETED AND SUBMITTED TO:

Unit 10 Review. 2. Materials for indoor floor, wall, and ceiling surfaces should be smooth, durable, and easily cleanable.

Transcription:

INSPECTION OF COMMERCIAL KITCHEN PLUMBING 801.1 SCOPE Food-handling establishments 2 - by John Williams, Jr. Plumbing Control Supervisor Onondaga County Water Environment Protection Commercial Kitchens 1/22/2015 PLUMBING DEFINITIONS 3 AIR GAP (DRAINAGE SYSTEM) 4 AIR BREAK (DRAINAGE SYSTEM) A piping arrangement in which a drain from a fixture, appliance or device discharges indirectly into another fixture or interceptor at a point below the flood level rim and above the trap seal. The unobstructed vertical distance through the free atmosphere between the outlet of the waste pijpe and the flood level rim of the receptacle into which the waste pipe is discharging. AIR GAP (WATER DISTRIBUTION SYSTEM) 5 BACKFLOW 6 The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. Pressure created by any means in the water distribution system, which by being in excess of the pressure in the water supply mains causes a potential backflow condition.

BACKFLOW PREVENTER/VACUUM 7 BREAKER A device to prevent backflow into the potable water system. There are three (3) types of vacuum breakers: 1.Atmospheric 2.Pressure 3.Hose bibb To determine which one you might need, call your county health department. ATMOSPHERIC VACUUM BREAKER (AVB) When the inlet valve of an AVB is closed, water flows in the normal direction, but, as water stops flowing, the air inlet valve opens, and interrupts any back siphonage effect. 8 9 BACKSIPHONAGE 10 The reversal of normal flow in a water system caused by negative pressure (vacuum or partial vacuum) in the water supply piping. Example: a garden hose attached to a service sink with the end of the hose submerged in a bucket full of detergent, then there is a loss of pressure in the water supply line and the detergent water flows into the potable water supply pipes. CROSS CONNECTION 11 FLOOD LEVEL RIM 12 A direct arrangement of a piping line which allows the potable water supply to be connected to a line which contains a contaminant. The edge of the receptacle from which water overflows.

INDIRECT WASTE PIPE POTABLE WATER 13 A waste pipe that does not connect 14 Water that is SAFE TO DRINK! directly with the drainage system, but that discharges into the drainage system through an air break or air gap into a trap, fixture, receptor or interceptor. FOOD-HANDLING ESTABLISHMENTS 801.2 PROTECTION All devices that discharge to the drainage system shall be provided with protection against: Backflow Contamination Flooding Stoppage of the drain 16 Fouling 15 Commercial Kitchens 1/22/2015 17 18 Commercial Kitchens Commercial Kitchens 1/22/2015 1/22/2015

SECTION 802 INDIRECT WASTES 19 802.1 WHERE REQUIRED Fixtures not required by this section to be indirectly connected shall be directly connected to the plumbing system in accordance with Chapter 7. 20 Commercial Kitchens 1/22/2015 Commercial Kitchens 1/22/2015 21 802.1.1 FOOD HANDLING 22 Equipment and fixtures utilized for Storage Preparation Handling of food shall discharge through an indirect waste pipe by means of an air gap. STORAGE Floor drains that are located within walk-in refrigerators or freezers shall be indirectly connected to the sanitary drainage system by means of an air gap. 23 PREPARATION Two-bay sink Single-service wash station Ice cream dipper wells 24

25 26 HANDLING OF FOOD 27 28 Two-bay sink Any other food-handling sinks or food/drink preparation sinks shall be indirectly connected to the drainage system. 802.1.2 FLOOR DRAINS IN FOOD STORAGE AREAS Floor drains located within walk-in refrigerators or freezers in food service and food establishments shall be indirectly connected to the sanitary drainage system by means of an air gap. 29 802.1.2 EXCEPTION! 30 Where protected against backflow by a backwater valve, such floor drains shall be indirectly connected to the sanitary drainage system by means of an air break or an air gap.

802.1.7 COMMERCIAL DISHWASHING MACHINES 31 32 802.2 INSTALLATION 33 802.2.1 AIR GAP 34 All indirect waste piping shall discharge The air gap between a waste pipe and through an air gap or air break into a waste receptor or standpipe. the flood level rim of the waste receptor Floor sinks Floor drains shall be a minimum of twice the effective opening of the indirect waste pipe. All above shall be trapped. AIR GAP DESIGN 36 If you have a 2 effective opening, the air gap shall be 4 If you have a 1-1/2 effective opening, the air gap shall be 3 35

37 802.2.2 AIR BREAK 38 Shall be provided between the indirect waste pipe and the trap seal of the waste receptor or stand pipe. 802.3 WASTE RECEPTORS 39 802.3.1 SIZE OF RECEPTORS A removable strainer or basket shall cover the waste outlet of the waste receptor. Access shall be provided to all waste receptors. A waste receptor shall be sized for the maximum discharge of all indirect waste pipes served by the receptors. Receptors shall be installed to prevent splashing or flooding. 40 802.3.2 OPEN HUB WASTE RECEPTORS 41 TRAPS, INTERCEPTORS AND SEPARATORS 42

43 44 45 46 47 1003.1 INTERCEPTORS & 48 SEPARATORS - WHERE REQUIRED Substances harmful or hazardous to the building drainage system, the public sewer, or sewage treatment plant or processes and private sewage disposal systems.

1003.2 APPROVAL 49 1003.3 GREASE TRAPS AND GREASE Size, type and location of each interceptor and of each separator shall be designed and INTERCEPTORS When are they required? installed in accordance with manufacturer s instructions and the requirements of this section based on the anticipated conditions of use. Wastes that do not require treatment or separation shall not be discharged into any interceptor or separator. 50 1003.3.1 GREASE TRAPS AND GREASE INTERCEPTORS REQUIRED 51 52 Are required to receive the drainage from fixtures and equipment with grease-laden waste located in food preparation areas such as restaurants, hotel kitchens, hospitals, school kitchens, bars, factory cafeterias or clubs. 53 1003.3.2 Food Waste Grinders 54

1003.3.4 GREASE TRAP AND GREASE INTERCEPTORS Shall conform to PDI G 101, ASME A 112.14.3 or ASME A 112.14.4 and shall be installed in accordance with manufacturer s instructions. 55 1003.3.4.1 GREASE TRAP CAPACITY AND FLOW RATES Determined by fixtures connected to the interceptor Minimum fixtures required to be connected to the interceptor shall be the hand sink, 3-bay sink, service sink and any and all fixtures that are used in the preparation of food or cleaning of the previously listed establishments. 56 1003.10 ACCESS AND MAINTENANCE OF INTERCEPTORS AND SEPARATORS Access to interceptors shall be provided for a disposal truck or rendering service to maintain and service interceptors. Grease removal systems shall be readily accessible without disruption of food preparation process. 57 58 FOOD SERVICE INSPECTION CHECKLIST 59 PAGE 2 OF 2 60 PAGE 1 OF 2

61 62 63 64 65 66

67 68 69 70 71 72

73 74 75 76 77 78

79 80 81 82 83 84

85 86 87 88 89 SECTION 608.16.1 BEVERAGE DISPENSERS 90

91 92 93 94 95 96

97 98 99 100 101 102

103 104 105 QUESTIONS? 106 THANK YOU!