Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

Similar documents
Wireless Base Remote Test and Hush

Fire / CO Alarm Interface

RadioLINK Alarm Base. Instructions. Model: Ei168RC

Datasheet for Models: 1SFWR 1SFW. NEW range. capability. 230V Mains Fast-Fit Ionisation Smoke Alarms. Key Features. Applications

Deaf & Hearing Impaired RadioLINK Alarm System

RELAY BASES & COVERS

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

RELAY BASES & COVERS

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

Carbon Monoxide alarm Installer s Guide

from the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year

Model: Ei450. Instruction Manual

Alarm Controller Fire and CO

Smoke and Heat alarm Ownerʼs Manual

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

230V Interconnectable Mains Operated Alarm model. For: 1275H

Digital Electronic Thermostat With RF

RF Modules for Battery Powered Smoke & Heat Alarms Ei600 Series

Smoke and Heat alarm User Guide

_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD

User Manual THR842DUK Wireless Digital Thermostat

Digital Electronic Thermostat With RF

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

U S E R M A N U A L UBH1RF HEAT ALARM

V-MUL-033(A0) RADIOLINK BASE

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

LOW FREQUENCY SOUNDER

Smoke alarm Installer s Manual

External Wireless Sounder

INSTALLATION AND USER MANUAL

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Installation Instructions

Model 17A00 Expansion Enclosure

installation & operation manual

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

Universal Fan and Light Remote Control

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Document No

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

PROGRAMMABLE 7-DAY RF THERMOSTAT

WT01 INSTRUCTIONS. English. GREEN COMFORT Maximum comfort with low energy consumption /15 (ALA) 2015 OJ Electronics A/S

OWNERS MANUAL MODEL 451 (-101 & -201)

evohome Sundial pack Thermostat

Temporary wireless battery operated fire system from Channel Safety Systems

48 TAYLOR CEILING FAN

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

External Wireless Sounder

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

KM300 Carbon Monoxide Detection System Installation Manual

RF Programmable Room Thermostat Installation Instructions

SP16. 08/50740/1 (UK) - Issue 1

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

L. Terminal block Connecting Label:

Electronic Thermostat With RF

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Intelligent SMOKE. Smoke Alarm User Guide. Photoelectric Smoke with Voice and Hardwire Interconnect. Model P4010ACS. 120V Hardwire

Sidekick II Receiver Model # SK2-SS 418MHz

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Mira Platinum Wireless Controller

User Guide. for the Beacon ProActTM 200 System

COMBINED STROBE & VIBRATING PAD

Smoke Alarm User s Guide. AC Wire-in Single and/or Multiple Station (up to 24 Devices) Photoelectric Smoke Alarm with 9 Volt Battery Back Up.

RadioLINK MAINS POWERED CARBON MONOXIDE ALARM WITH RECHARGEABLE LITHIUM CELL BACK-UP. Model Ei262

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

52 BERKSHIRE CEILING FAN

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

ThermoPlus AS2-RF & ASR-RF Installation Instructions

52 STRATHMERE CEILING FAN

Static Pressure Control

MBCE-110/230UV Flame Sensor Module

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Heat Alarm User s Guide

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

BGH Series Hot Surface Ignition Control

CentaurPlus ZW and HRT4-ZW

WBS-616 User Manual. Wi-Safe Remote Warning Handset Part of the Wi-Safe Home Safety System

Installation and ZONES: Operation Manual. Model: ON STI-34108

Macurco HD-11 Hydrogen Gas Detector

Installation, Operating and Maintenance Manual

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

MBCE-110/230FR Flame Sensor Module

Transcription:

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 1 Wireless Alarm Base RF-SFTP 230V Mains Operated Wireless Interconnectable Alarm Base with Rechargeable Battery Backup For use with the following models with the designator: 1SFW, 1SFWR, 2SFW, 2SFWR, 3SFW and 3SFWR Thank you for purchasing a Kidde Fyrnetics alarm accessory. Please read through our manual in full. Important information included and the manual must be left with the householder. Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected). Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. www.kiddefyrnetics.co.uk Kidde Fyrnetics 2010 21008418 REV. B 1 1 1209-7201-02

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 2 Introduction The RF-SFTP wireless base can be fitted with Kidde Heat and Smoke Alarm models that have the designation following the model number. Up to 15 wireless bases can be fitted in a system due to constraints of the supervised system (see installers guide of alarm for limits of alarms). Although the RF system is limited 15 bases, the system can have up to 24 devices. Warning: Do not interconnect two wireless bases with the hardwire as well. This will cause a signal loop that will never exit alarm once started. The wireless base uses radio signals to interconnect alarms. When installed, if one unit alarms for an event it will communicate with the other alarms using radio communication. Remote test and hush functionality can also be added wirelessly using the KN-RTH-RF accessory Unit does not support carbon monoxide alarm signals The wireless base will not recognize a signal from an interconnected CO alarm. However, an interconnected CO alarm will not hinder the wireless base system. The wireless base will only receive and transmit smoke and heat alarm signals. This wireless base is mains powered having a rechargeable battery system providing back up power for approximately 3 months on mains failure. Installation Instructions Introduction This wireless base is designed for installation by a competent, qualified electrician, in accordance with the latest I.E.E. Regulations and complying with relevant building regulations. Read these instructions thoroughly before proceeding. People s lives depend on it. This manual is for use by qualified electricians. Wireless alarm base and attached alarms must be powered by a constant 230V AC, 50Hz supply that is not controlled by any form of switch. It is not suitable to be connected being controlled / supplied by a light dimmer circuit. Failure to comply with this directive may lead to product failure / overheating of components which is outside the terms of the guarantee. WARNING: This alarm cannot be operated from power derived from a square wave or modified sine wave inverter. These types of inverters are sometimes used to supply power to the structure in off grid installations, such as solar or wind derived power sources. These power sources produce high peak voltages that will damage the alarm. Kidde recommends to connect alarms and bases to a dedicated circuit that is separately electrically protected. This helps minimise interference (EMI) on alarm interconnect line from CFL's, dimmers, LV transformers etc. This wireless base will not detect smoke or heat and must be installed in conjunction with the specified alarms. Only connect to the specified models of smoke or heat alarm. Do not connect to any other brand of alarm/auxilary device unless approved by Kidde. 2

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 3 The earth terminal connection provided is for termination purposes only and is NOT electrically connected within the sealed alarm / base units. Danger electrical shock hazard! Do NOT subject the alarm circuit to insulation resistance testing with the alarm / base units connected. Failing to do so will cause damage outside the terms of the guarantee provisions. Never restore power supply until all alarms are completely installed, doing so before hand can cause serious injury. Do not install in a dripping, water splashing, or very humid area. Interconnecting To connect all alarms with wireless bases use only the line and neutral lines, do not connect to the I/O terminal. Line House Cabling Refer to IEE Reqs Neutral To expand an existing interconnected system, connect a wireless base to one alarms of the hardwired system and then and additional wireless base at each new location. DO NOT HARDWIRE INTERCON- NECT TWO ALARMS WITH WIRELESS BASE TOGETHER. Line Neutral House Cabling Refer to IEE Reqs Line Neutral Interconnect (I/O)* These are double insulated products and do not need earthing: never use earth conductor to interconnect use 3 core and earth cable. Use black in 3 core & earth cabling, for interconnect line. If installing using old cabling (different colors), take great care / follow IEE Reqs. A maximum of 24 Kidde devices may be interconnected in a multiple station arrangement the interconnect system should not exceed 12 Smoke Alarms and/or 18 alarms total (Smoke, Heat, CO and etc). With 18 alarms interconnected up to 6 alarm accessories (relay modules, visual signal device and etc.). For systems utilizing wireless bases the same restrictions apply but the maximum number of wireless bases is limited to 15. 3

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 4 RF-SFTP Wireless Base Set Up 1. The smoke alarms and wireless base should be positioned as recommended in the installation guides supplied with the alarms with special care to avoid possible causes of interference with the RF signal(such other wireless products, electronic devices and large metal objects). 2. The installation method for the alarms and base is described in the smoke alarm installation manual for the alarms. All wiring connections are made via the under side; the wireless base is sealed and does not contain any user serviceable parts. 3. Bring house wiring through a dry lining box into back of alarm; side entry, via mini trunking is also possible by carefully knibbling away edge on trim-plate. Make good joint, with white sealant, if necessary. When installing the base using trunking, do not attempt to break or knockout the sections out, use a tool to cut them and prevent damaging the base. Figure 1, Mounting Methods 4. Mains alarms and the mains powered RF-SFTP wireless base are designed for installation by a competent, qualified electrician, in accordance with the latest I.E.E. Regulations and complying with relevant Building Regulations. Provide mains power to all units, with which the rechargeable battery is turned on for service. 5. Care should be taken to insure the wires are pressed firmly into the appropriate holes on the terminal block (Do not use slots for wire retention, see figure d). Pull back lightly on each wire to verify it is seated well.) Figure 2, Terminal Block 6. Verify that the power is on,the power is present when the amber and green LEDs are illuminated. Choose a unit in a central lo cation as the master unit. This unit will enrol the other units(create a linked system) during the remaining process; the remaining units will then be remote units. Press the enrol button on the master unit until the amber LED turns off (takes approximately 5 seconds) and begins to flash on/off every 2 seconds with the green LED flashing every 4 seconds. (This indicates this unit is broadcasting as the MASTER unit). THIS UNIT IS NOW THE MASTER WIRELESS BASE Figure 3. Side of Base with Alarm Attached FUNCTION BUTTON ENROL BUTTON CEILING ALARM ALARM RELEASE LATCH GREEN LED POWER/TRANSMIT IND. AMBER LED ERROR INDICATOR 4

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 5 7. Go to the nearest unit (this will be a remote unit) and press and release the enrol button. The amber LED will flash - 2 seconds on and 2 seconds off (it may immediately start flashing 1-6 times if it catches a message from the master).when it has received an invitation from the master unit the amber LED will flash 1-6 times every 4 seconds to indicate the signal strength; a good signal level is indicated by 3 or more flashes. If the remote is only flashing 1 or 2 times, try rotating the wireless base or moving it away from obstructions like large metal objects and lighting fixtures. 8. Press the enrol button on this remote; the amber LED will blink rapidly showing it is enrolled, and that the system is still in enrolment mode. 9. Repeat this procedure with all other remote alarms. 10 Return to the master unit and press the enrol button. This will cause the green LED to go out for one second in ten to indicate the master is broadcasting. Failure to follow this procedure will cause the master unit to time out after ten minutes automatically enrolling any other compatible systems nearby that are being set up / enrolled. 11. To visually check the system is operating The master unit is recognised by the green LED flashing 1 second every 10 seconds. A remote is recognised by a quick flash of the green LED once every 10 seconds. 12.The system is now functional. If the amber LED flashes every 10 seconds it indicates that the battery is low and will require 24 hours to become fully charged whilst connected to the mains supply' Pressing the enrol button during enrolment will end the process and put the unit back into standby even if not enrolled with other units. Any unit can be reset to its factory settings; refer to the following section, Resetting unit to factory condition for details. Determine location for all alarms. Amber LED flashes every 4 sec. Press and release enrol button on remote unit System Enrolment complete Connect all units to AC to turn the units on. Press and release enrol button on remote unit Amber LED flashes continuously Amber LEDs off, Green LEDs flash every 10 sec. Press and hold enrol button on master unit Amber LED on 2sec./off 2 sec. Green flashes ever 4 sec. YES More remotes? NO Press and release enrol button on master unit 4

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 6 LED Settings Chart Factory setting Enrol mode Normal operation Error modes Remote unit Error modes Master Unit Low Battery Indiction Status Action No LED function when connected Unit is not powered and will not Check to insure battery is connected correctly and the connector is to 230VAC Mains function seated completely. Check that power is present at the connection. Amber LED is not on/green LED Unit is a remote station, has AC No Action needed blinks off quickly ever 10 seconds mains power and operating correctly Amber LED is not on/green LED turns off for 1 second ever 10 seconds Amber and green LEDs are not on or flashing* Amber LED flashes every 2 seconds and the green LED is lit continuously Amber LED flashes every 5 seconds and the green LED blinks for 1 second once every 10 seconds Green Amber Comment On On Not enrolled in system Blinking every 4 sec. 2 seconds on every 4 seconds Master unit enrolling remotes. On 2 seconds on every 4 seconds Remote waiting Flashes 1-6 flashes every 4 Remote seconds communicating On Blinking Remote enrolled Off 1 second every 10 seconds Off 0.5 second every 10 seconds Fault Finding Chart Off Off Flashes every 2 seconds Flashes every 5 seconds Flashes every 2 seconds Flashes every 10 seconds Unit is a master unit, has AC mains power and operating correctly Unit has no mains power Master unit Remote Unit Has poor or no communication link with master unit. Poor or no communication with at least one remote unit. Poor or no communication with (all) remote unit(s). AC Power has been disrupt for exteneded period or battery is faulty. Unit is a remote station and does not have a reliable communication path with the master unit. Unit is the master unit and does not have a reliable communication path with one of the remote units. No Action needed Check breaker and have an electrician check the circuit for proper AC mains power. Determine if there is an obstruction like a large metal object that has been placed between the remote and master units causing interference. Relocate the obstruction or the RF units. Amber LED every 2 seconds and the green LED blinks for 1 second once every 10 seconds or less. Amber LED flashes every 10 seconds and the green LED blinks once every 10 seconds. Amber LED is one for 1 sec. then off for 1 sec., green LED flashes ever 4 sec. Amber LED is flashing on and off rapidly Unit is the master unit and has lost communication with all remote units. Unit is in Low battery Unit is master unit and is in enrol mode. Unit is a remote unit, is enrolled but system is in enrol mode. Insure green LED is on indicating 230VAC Mains power is present for at least 24 hours. After 48 hours with power, contact customer support Complete the enrolment process and press the enrol button on the master units *Green LED is lit to show AC mains connected and flashes as detailed to indicate condition. When AC mains is not connected, green LED will flash rapidly to indicate it is transmitting in alarm/test state but will not flash otherwise. 5

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 7 Adding an additional wireless unit This process is to enrol additional wireless bases to an existing system. 1. Install and power up the new unit. The Amber and the Green LED of the new wireless base will both be on. 2. Go to the master alarm. (See section 1 above to recognise a master and remote RF wireless base). 3. Press the enrol button for 1-2 seconds on the master RF wireless base. The amber LED will flash on for 2 seconds and off for 2 seconds. It is ready to enrol a new remote wireless base. 4. Press the enrol button for 1-2 seconds on the new remote alarm RF base. The amber LED on the wireless base will flash on for 2 seconds and off for 2 seconds. When the master unit invites it to join the amber LED on the remote wireless base will flash 1-6 times every 4 seconds. 5. Press the enrol button on the new remote to complete the process. The amber LED will blink rapidly indicating the remote has completed the enrolment process. 6. Return to the master unit and press the enrol button a second time to set the system. Removing a wireless unit. NOTE: Alarms can be replaced without replacing the wireless base. 1. If a wireless base needs to be removed from the system, remove power from the unit to be removed and wait for 5 minutes for the master unit to recognize the error. Go to the master unit (see section 1 as to how to distinguish between the master and remote RF units) and verify that the amber LED is flashing (or on continuously if there is only two units in the system). Press the enrol button on the master RF wireless base. The amber LED will begin to flash on for two seconds and off for two seconds. 2. Press the enrol button on the master unit a second time to finalise the new system. Resetting unit to factory condition. The wireless base may be reset to the factory settings at any time by pressing both buttons for ten(10) seconds. (this may be helpful if there is confusion during enrollment or if the base is being relocated). 1. Press and hold the function button before pressing the enrol button. 2. While holding the function button press the enrol button and hold both until the amber LED flashes rapidly 10 times and then remains lit. 6

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 8 Monitoring the Wireless link. The system is designed to automatically and continuously monitor the wireless link between the alarm. when powered by AC mains (230Volts) The master alarm broadcasts every 10 seconds; the green LED will flash to indicate this. The master unit will monitor the response from each remote. If a remote has not communicated with the master unit within 2 minutes the master unit will send 4 rapid broadcasts to try to reestablish a link. If the communication with the remote is still absent the master amber LED will blink. If the remote has missed the master for 2 minutes the remote amber LED will flash every 5 seconds (see LED table). Once communication between the master and remote units is re-established, both units will automatically return to normal operation and the amber LED will stop flashing. This may take a couple a minutes once the link is re-established to clear the error. On battery backup the units are not supervised and only listen for messages. Re-establish AC power as soon as possible. Connecting the Remote Test and Hush Accessory The remote test and hush accessory (model KN-RTH-RF) is a useful portable device allowing you to test and hush the alarms within the wireless system without the requirement to physically reach the alarms' test button. It can be affixed to a wall or used placed in a suitable location I.E. on a table. Please see owners manual supplied with the accessary for additional details. Each wireless base may have only one remote test and hush accessary enrolled at a time. We recommend you enrol it with the alarm in your main living area. 1 Press the enrol button on the base and ensure it has enter enrol mode indicated by the amber LED flashing. 2. Press any button on the accessory. 3. Verify the amber LED on the alarm has changed from 2 seconds on 2 seconds off to rapid blinking. 4. Press the enrol button a second time on the wireless base to complete the process. 7

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 9 Technical Specification Mains power: 230VAC / 50Hz. Backup Power: Lithium secondary battery with up to 3 month capacity Temperature (operating): 0 40 C Humidity: 0-95% (non-condensing) Radio Frequency: 868MHz Wireless range: Greater than 150m in free space. Mechanical: 12.7cm dia x 3.5cm 150 g. Approvals (Independently tested to comply with): EMC Directive 89/336/EEC R&TTE Directive 99/5/EC ETSI EN 301 489-1 V1.8.1 (2008-04) ETSI EN 301 489-3 V1.4.1 (2002-08) ETSI EN 300 220-1 V2.3.1 (2009-04) ETSI EN 300 220-2 V2.3.1 (2006-04) EN 55022: 2006 EN 61000-3-2: 2006 EN 61000-3-3: 2005 Disposal ENVIRONMENTAL PROTECTION Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with Local Authority or Installer for recycling advice. 9

1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 10 Guarantee Kidde Fyrnetics guarantees to you as a purchaser that the alarm accessory will be free of defects in material, workmanship or design under normal use and service for a period of ten (10) years, from the date of purchase. The Guarantee is not assignable. Our liability to you, under this guarantee is limited to repairing or replacing any part which we find to be defective in material, workmanship or design, free of charge to the customer, who is situated within the UK and Eire, upon sending the base with proof of date of purchase, postage prepaid, to Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. The terms of this guarantee will not apply in the following circumstances: If unit has been damaged, modified, neglected, dismantled, contaminated, abused or altered after the date of purchase, or if it fails to operate due to incorrect selection, sitting, installation, maintenance or inadequate AC electrical power, or damage caused by failure to abide by the instructions supplied. The liability of Kidde Fyrnetics, arising from the sale of this wireless base or under the terms of this guarantee shall not in any case exceed the cost of replacement of the device, in no case, shall be liable for consequential loss or damaged resulting from the failure of the alarm or for the breach of this or any other guarantee, express or implied, or for damages caused by failure to abide by the instructions supplied. This guarantee does not affect your statutory rights. 10