Control Panel Basics Volume 1

Similar documents
Selection Guide. Logic: From basic to programmable network controllers» Safety Components. Output: Safety relays, servo systems, and inverters

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

E3FA PHOTOELECTRIC SENSORS

Safety Design EN ISO and Safety Performance Levels

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Model Number Structure

Temperature Control Library

Ultrasonic Reflective Sensor

E3FA PHOTOELECTRIC SENSORS

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

RE-PR3-E-27 3-Phase Panel Mount 27kW

Single Source for Machine & Process Safeguarding Solutions

EU DECLARATION OF CONFORMITY. 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.

Ultrasonic Reflective Sensor

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Ultrasonic Proximity Sensor

ISIS SAFETY SYSTEM Installation guide

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

E3M-V. Mark Sensor. Applications

Dräger PointGard 2100 Detection of toxic gases and vapours

ZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing

Temperature Controller

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Cooling Fans ver ver.4

Sensing for standard and special applications

Original instructions. Operation Manual & Cautions

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

MTRA-FSP Level Control Relay. Installation & Operation Manual

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Products designed for extreme washdown environments IP69K Products

Ultrasonic Proximity Sensor

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

EQUIPMENT Operation Manual

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Semi flush-mount room thermostats

MBCE-110/230UV Flame Sensor Module

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

COMPLETE PACKAGING SOLUTION

Two global companies, one solution.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Installation, operation & service manual. AlarmScout 961/962 line powered

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Installation, operation & service manual. AlarmScout 961/962 loop powered

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Dust Concentration Meter

LGA... Gas Burner Controls. Building Technologies Division

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

SAFESMART Backup Controller SAFE-FSP. Installation & Operation Manual

Operating Instructions

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

Bringing IoT innovation to the plant floor IO-Link series

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Motor Condition Monitoring Device K6CM

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

E3FA PHOTOELECTRIC SENSORS

RP SERIES THERMAL PROTECTORS

Part 3 Troubleshooting

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Machine Guarding and Safety

Room thermostats with LCD for wall mounting

Monitoring Devices 11/1

Operating Instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

DTA. Motor thermistor relay. Benefits. Description

Instructions for the fan motor control system, SILVER C

UL TEST REPORT AND PROCEDURE

Whole Room Dryer WRD, WRD/110

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

Mark and Colour Sensors

* Consult factory on conditions for approval acceptability

SensaGuard TM Integrated Latch Installation Instructions

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

EUROBOX SERIES TYPES CM...N SM...N MM...N

Plug-in Base, Long Range Sensor E3B2

Power Supply Display Module PSDM. Installation and Operation Manual

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Varistar LHX 3 Air/Water Heat Exchangers

MANUAL Oil Level Sensor

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

Transcription:

New Value for Control Panels Control Panel Basics Volume 1 Safety Heat Humidity Ground Fault

2 Basic Information on Control Panel Design Knowhow on Control Panel Design, from Safety Standards to Preventive Measures against Heat, High Humidity, and Ground Faults Changes in the market require handling a wide variety of control panel issues. Control Panel Basics describes OMRON s wealth of knowhow and information and provides easy-to-understand descriptions of the knowledge required to solve these issues through concrete examples.

Control Panel Basics Volume 1 3 Control Panel Basics Volume 1 CONTENTS Important Points on Control Panel Design Points on Panel Design for Conformance to IEC 60204-1 P. 4 Heat Measures Knowhow on Fan Selection and Installation to Prevent Device Failure Caused by Heat P. 6 High Humidity Measures Measures against Short-circuits Caused by Condensation from High Humidity P. 8 Ground Fault Measures Causes of and Measures against Breaker Activation by Added Devices P. 9 Control Panel Column Difference in DIN Track Height P. 10

4 Important Points on Control Panel Design The IEC 60204-1 electrical safety standards related to machine control panels must be considered. The power supply breakers, device locations, and electric-shock prevention for control panel design are described from the viewpoint of safety standards. Power Supply Cutoff (Breaker) Devices - ON and OFF must be indicated. - There must be an external operation means (e.g., handle). - There must be a means to lock the device in the OFF position. - There must be a suitable cutoff capacity. Etc. Power Supply Cutoff (Breaker) Devices Device Locations (1) Power supply cutoff devices: 0.6 to 1.9 m, recommended max.: 1.7 m (2) Manual operation devices: 0.6 m or higher (3) Terminals: 0.2 m or higher (4) Devices that must be approached for periodic maintenance or adjustments: 0.4 to 2.0 m Enclosure Degree of Protection: IP22 or Better Electric Shock Prevention When Enclosure Is Opened: - It must be possible to open the enclosure when charged sections are cut off. - If the enclosure can be opened without cutting off a charged section, all charged sections must have IP2X or IPXXB protection. If a barrier is provided, a tool must be required to remove it or the charged section must be automatically cut off when it is removed. Additional Information IP2X: Protection against foreign objects with a diameter of 12.5 mm or larger (equivalent to a finger) IPX2: Protection against vertically falling water drops when enclosure tilted up to 15 IPPXXB: Protection against an approaching finger Reference Illustration (Numbers 1 to 4 correspond to items 1 to 4 under Device Locations.) Control Panel (Enclosure) Manual Operation Devices (e.g., Operation Switches) 2.0 m 1.9 m (1.7 m) (1) (4) Power supply cutoff device operation handle (e.g., breaker) 0.6 m (2) 0.6 m (3) 0.2 m 0.4 m - The structure does not allow the panel door to be opened unless the power supply is cut off. - If the door can be opened without cutting off the power supply, charged sections must be protected, e.g., with covers, so that they cannot be touched with fingers or similar objects. Note: The values are the heights from the working surface.

Control Panel Basics Volume 1 5 Control Panel Component Colors It is important to correctly understand the meaning of the colors of indicators, operation parts, and wires. Machine status indicated by indicator color General meaning of operation device (operation part) color General rules Color Red Yellow Green Meaning Emergency Caution Normal Description Operator action Description Application example Hazardous situation Abnormal situation An impending critical situation Normal situation Immediate action for the hazardous situation Monitoring and/ or intervention No specific action required Actuate in the event of a hazardous situation or emergency Actuate in the event of an abnormal condition Actuate to initiate normal conditions Emergency stop Stopping or turning OFF for emergency stop Initiation of emergency function Intervention to suppress abnormal condition Intervention to restart an interrupted automatic cycle White is the most suitable color for a device (operation part) for starting or turning ON something, but green is also acceptable. Human or environmental safety Hazard Caution Safe Process status Emergency Abnormality Normal Blue Mandatory Indication of situation requiring operator action Required action Actuate for a condition requiring mandatory action Reset function Mandatory White Neutral Other situations Situation in which the use of red, yellow, green, or blue does not seem appropriate Monitoring Initiation of functions White can be used for any function other than an emergency stop. Color Requirements for Emergency Stop Switches Operation part: Red Background: Yellow Wire Colors (IEC 60204-1) Applicable conductor Ground (earth) circuit Power neutral circuits Primary power circuits DC control circuits AC control circuits Excepted circuits (e.g., interlock circuits) Color Green-yellow spiral Light blue Black Blue Red Orange Note: Excerpt from IEC 60204-1 Recommended Operation Devices Globally applicable switches conceived for compactness, simplicity, and safety. Pushbutton Switches A22N Emergency Stop Switches That Conform to Various Standards Emergency Stop Switches A22E Search for OMRON A22N for details. Search for OMRON A22E for details.

6 Heat Measures The correct Fan must be selected to suppress temperature rise inside the panel. If the temperature inside the panel increases, the lives of devices and parts inside the panel will be reduced and malfunctions could result. Particularly devices and parts that generate heat are greatly affected by heat. Panel cooling and Fan selection are extremely important to long-term usage of the panel and parts inside the panel. Selecting Fans 1 Check the heating values of devices and the panel (kw). Check the heating value of each device located in the control panel and then find the total heating value. Generally speaking, the heating value indicates the power consumption, so you can assume that the power consumption equals the heating value. Heating value (W) = Input power Output power 2 ΔT of devices and panel: Allowable temperature rise ( C) = Output power Output power Efficiency ΔT = T2 T1 ΔT can be obtained by subtracting the device ambient temperature, T1 from the allowable internal temperature, T2. Note: As a guideline, you can make the calculation with a value of 10 C. (Use the more severe condition.) ΔT = 10 C (guideline) T1 Source of heat T2 3 Calculate Q, the required flow rate (m 3 /min). 50 W Q = ΔT m 3 /min Q = Flow rate (m 3 /min) ΔT = Allowable temperature rise ( C) W = Heating value (kw) 4 5 Select the size of the required Fan based on the maximum flow rate. Normally, select a Fan with a maximum flow rate of 1.3 to 2 times the calculated required flow rate (Q). As the flow rate increases, noise increases. If the Fan is used in an environment where noise is a problem, select a Fan with a lower flow rate. Selecting Options If fine foreign matter may enter the Fan, select a Filter. If slender objects such as fingers may enter the Fan, select a Finger Guard. Note: Actually results may vary from calculations, so measurement and confirmation in the actual panel are required. Calculation Example for a Control Panel with Two 100-W Power Supplies Note: The S8JX-N10024C (output voltage: 24 VDC, output current: 4.5 A, efficiency: 83% min.) is used for the 100-W Power Supplies. First, the heating value (power consumption) is calculated. Models and Maximum Flow rate Maximum flow rate (m 3 /min) 24 (V) 4.5 (A) Model Size (mm) 50 Hz 60 Hz Heating value (W) = 24 (V) 4.5 (A) 83 (%) R87F-A@A15HP 120 120 t 38 2.7 3.1 108 (W) = 108 (W) = 22.120 (W) R87F-A@A13HP 120 120 t 25 1.9 2.2 0.83 R87F-A@A93HP 92 92 t 25 0.9 1.0 Two Power Supplies are used, therefore, R87F-A@A85HP 80 80 t 38 0.8 0.9 22.12 (W) 2 44.2 (W) 0.04 (kw) R87F-A@A83H 80 80 t 25 0.6 0.7 50 0.04 (kw) Q: Required flow rate = 0.2 [m3 /min] ΔT: 10[ C] Point! If the flow rate is insufficient, two Fans can be operated in Maximum flow rate calculation: Q 2 0.2 2 = 0.4 [m 3 /min] parallel for approximately twice the flow rate. Therefore, one R87F-A@A83H is required from the table on the right. Note: This calculation example assumes that the control panel contains only two Power Supplies. Q1 2 Q2 Q1: Flow rate of one Fan Q2: Flow rate for parallel operation

Control Panel Basics Volume 1 7 Airflow Direction and Inlet/Outlet Cooling Effect Differences When the Heat-generating Portions Are Concentrated at One Location When the Heat-generating Portions Are at Many Locations Reference Information: The Fan airflow is in one direction, which is indicated on the top of the Fan. Heat generation Heat generation Heat generation Heat generation Fan rotation direction Airflow direction Inlet airflow direction Advantages of Inlet Installation - You can concentrate cooling on the heat-generating portions. - The pressure inside the box increases, which reduces dust entry from other openings. Advantages of Outlet Installation - A wide area can be cooled. Outlet airflow direction Fan rotation direction Recommended Axial Fans R87F AC Axial Fans Large Size [mm] 120 120 t 38 R87F-A@A15HP 120 120 t 25 92 92 t 25 R87F-A@A13HP R87F-A@A93HP 80 80 t 38 R87F-A@A85HP 80 80 t 25 Small R87F-A@A83H Flow rate [m 3 /min] 0.6 (0.7) 0.8 (0.9) 0.9 (1) 1.9 (2.2) 2.7 (3.1) at 50 Hz (at 60 Hz) Options Models Plug with Cable * Finger Guards R87F-PC R87F-FG@ Plug with Cable Filters R87F-FL@(S) *Not required for Fans with lead wires. Finger Guard Filters Search for OMRON R87F for details.

8 High Humidity Measures If a control panel is installed in a location with high humidity, measures against short-circuits are required. Condensation will occur in the control panel as the result of a difference in the device temperature and external air temperature. This condensation may adhere to a PCB and if condensation and dust repeatedly collect on the PCB, short-circuits will occur. Examples of Short-circuits Caused by Condensation Case 1: Short-circuit from Water Drops Generated by Condensation Case 2: Short-circuit Caused by Repeated Condensation and Dust Collection Processing Schedule Morning Afternoon Facilities stopped. Aging Facilities operated. Break Aging Facilities operated. Facilities stopped. Condensation will occur if there is a difference between the temperature resulting from device heat generation and the air temperature while the facilities are stopped. Preventing Short-circuits with Products with Coated PCBs or Modifications Coating PCBs can be coated to protect them against humidity and reduce the possibility of short-circuit accidents. Recommended Products with Coated PCBs Ask your OMRON representative for more information on coating. Switch Mode Power Supplies S8VK-G Timers H3CR H3Y H5CX Digital Temperature Controllers E5@C E5CB Micro PLCs CP1E CP1L CP1H CP1W Counters H7CX H7E@-N Search for OMRON with the model name.

Control Panel Basics Volume 1 9 Control Panel Column Why There Are Two Different DIN Track Heights The two types of DIN Tracks are both made of aluminum, but the heights, which increase the mounting strength, are different. Small, lightweight devices, such as Relay Sockets, can be mounted to the DIN Track with a height of 7.3 mm without concern. Large, heavy devices, such as Power Supplies, require more track strength, so the DIN Track with a height of 16 mm must be used. DIN Track with a Height of 7.3 mm Is OK for Mounting Small, Lightweight Objects If a large device is mounted, the back of the device may interfere with the mounting surface. Use DIN Track with a Height of 16 mm for Large, Heavy Objects This type of DIN Track also provides more distance from the mounting surface, so interference with the mounting surface is less likely. Recommended DIN Track For Mounting Small, Lightweight Devices For Mounting Large, Heavy Devices DIN Track with 7.3-mm Height PFP-100N/-50N DIN Track 7.3 with 16-mm Height 16 PFP-100N2 Search for OMRON PFP for details. Search for OMRON PFP for details. Let OMRON Solve Your Control Panel Challenges New Value for Control Panels A product and service catalog is available to help solve a wide range of control panel challenges, such as downsizing. Ask your OMRON representative for details. Solutions to Downsize Control Panels Catalog (Cat. No. Y204)

New Value for Control Panels OMRON offers products and services to solve your diverse control panel challenges and contributes to growing your business. OMRON Corporation Industrial Automation Company Kyoto, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON Corporation 2015 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. Y122-E1-01 Printed in Japan 0715 (O)