D3 Wireless temperature alarm & monitoring system family. tek-troniks

Similar documents
DATAssure. Laboratory wireless alarm & monitoring system

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

Affordable wireless monitoring without compromise

MIRADOR Real Time Monitoring

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Dew point set DS 400

Smart Wireless Sensor

FLOOD SERIES DATA SHEET

Ion Gateway Cellular Gateway and Wireless Sensors

Smart Wireless Sensor

Security designed for your lifestyle

Affordable wireless monitoring without compromise

Cold chain monitoring technologies. Facility monitoring

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

EL-OEM-3 OEM Packaged Voltage Data Logger

Exceptional data integrity. Complete peace of mind.

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Monitoring Solutions

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

EasyLog Data Logger Series

REMOTE MONITORING AND ALARM SYSTEM

3D_ISS. Integrated Software System. User Guide Manual

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

Specifications Minimum Typical Maximum Unit

FX150 OTDR. Platform Highlights. Key Features

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

SC-F3G User Manual 1.0

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

THX-DL Data Logger USER & INSTALLATION MANUAL V

Measuring Recording Online Monitoring Regulation Alarming

CAN unit for Analog Sensors

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Common Customer Challenges

EL-USB-TC Thermocouple Data Logger with USB Interface

RACK MONITORING SYSTEM - RAMOS Ultra

HOME MANAGEMENT GATEWAY

Consultant Specification AGILE Wireless Fire Detection System

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Ontech GSM 9040/50. Reference Manual English -1 -

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Data Logging Solutions

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Chromatographic Air circulated Refrigerator, two-door TC 603

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

RACK MONITORING SYSTEM RAMOS Ultra

600 Range Dialer Installation Manual. Version 1.0

SCAN200E USER S MANUAL

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Patriot Systems Limited

ACCESS Master MT9085 Series. Product Introduction

AirTest Technologies Inc.

EL-OEM-3 OEM Packaged Voltage Data Logger

NEW. RF500 Wireless Monitoring. and improved. Exceptional data integrity. Complete peace of mind.

HRX Technical Manual. Version 1.2


APPLICATION DATA SHEET

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

EL-USB-1-LCD Temperature Data Logger with LCD

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Typical applications include the vibration detector. Detection of vibrations and shocks

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Outdoor Temperature Sensor

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

SENSAPHONE 901 Tryens Road Aston, PA PH:

EL-USB-1-LCD Temperature Data Logger with LCD

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

VIBRA-series: VIBRA, VIBRA +

SYSTEM OVERVIEW. Environmental Monitoring. Simplified.

GMS GRAPHICAL MANAGEMENT SYSTEM

ACTIVE INFRARED BARRIER


2G & 3G GSM Door Contact Alarm

Architectural and Engineering Specification for a Security Management System. StarNet 2

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

SunLite OTDR+ Platform Highlights. Key Features. Power meter, light source, fiber inspection probe and VFL options

Data Center. Cold Storage

Integrated Security Solutions

Patriot Systems Limited

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

Architectural and Engineering Specification for a. Flash / Flare

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

AmpLight group management

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

2G & 3G GSM Portable PIR Alarm

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Complexity made simple

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

XYZ XYZ XYZ XYZ XYZ XYZ. Energy Utility Based billing for Individual Tenants. Comprehensive Base Station Monitoring. Diesel Generator Monitoring

Transcription:

D3 Wireless temperature alarm & monitoring system family tek-troniks

D3 Wireless temperature alarm & monitoring system family No server or dedicated pc No ongoing cloud costs or licencing fees. Fully web based no software installation necessary In built reporting and graphing tools 5 Long range wireless sensors User replaceable 5 year battery Vast array of sensors types Battery & data-backup for complete data security * 02

A new monitoring generation The D3 family of wireless monitoring systems are used across a broad range of market sectors meeting the most stringent standards to assist customers comply with HACCP, BRC, FDA and MRHA legislative requirements. The systems are standalone and connect direct to your business IT network with no need for any dedicated pc, server or specialist installed software. Data from the base station can be viewed direct on the colour touch screen or via a standard web browser. The base station allows multiple secure connections and data can be viewed on multiple devices from PC s to tablets to mobile phones though its simple to use and intuitive web based interface. PPM ºC ºC %RH System overview A typical system comprises of a base station, wireless sensors and where necessary wireless signal repeaters (range extenders). The wireless sensors are paired with the base station to form a secure communication network. If the wireless sensor is not in range of the base station, an optional wireless signal repeater can be added to increase the distance. Multiple repeaters form a mesh network allowing the base station and sensors to communicate over long distances and in complex structures. Each wireless sensor monitors the sampled factor (e.g. temperature, humidity, pressure) and sends the reading each minute over the wireless network to the base station. The base station reviews the data against pre-set warning and critical alarm parameters as defined by you to generate alarm notifications. All readings are stored in a secure tamperproof format for later review and creation of reports. Kwh Temperature Humidity Energy Door Contact ppm 0I00I0 I00I00 III00I0 y x Pulsed Concentration (ppm) Digital Input Linear (0-10V,4-20mA) 03

D3 Base Station The base station collects data from the wireless network. It incorporates a colour touch screen display allowing both real time data and alarm notifications to be viewed. An internal sounder and high brightness LED provide local alarm indication while two configurable volt free contacts provide connections for auto diallers, remote beacons & red care monitored lines. The base station connects direct to your IT network via a standard CAT 5 Ethernet connection. It s in built barracuda web server interface provides secure controlled access for multiple users across different platforms. Interface access The web server interface enables 24/ 7 permission based user access. User management is controlled by one or more system administrators. Each user is automatically allocated a unique electronic signature which along with their details are recorded against each action they make providing total accountability. The web interface provides access to real time data, alarm notifications, full audit trails, analytical graphing tools and a report generator all via a standard browser. Monitored devices can be organised into groups. Status page provide real time data together with their operational settings and current status. A tabbed section provides quick view sorted lists enabling the user to quickly highlight potential issues and devices in alarm from a single click. 04

Alarms and notifications If the received data falls outside the defined parameters the base station activates an alarm notification. The software can be configured to generate audible warnings, email, SMS text **, trigger beacons and auto diallers and send alarm notifications over IP to 3rd party alarm companies. Users acknowledge alarms using their passcodes and can add multiple notes to each alarm to detail any actions that have been taken. All alarm notifications, user acknowledgements and action notes are time stamped and recorded to provide a full audit trail. Data analysis and reports A powerful graphing tool allows data from different sensors to be overlaid and viewed over different time periods. Data can also then be printed or exported to a csv file. In addition to the graphing tool, the system can provide reports to aid with legislative requirements. Reports are created in a PDF format which can be printed and saved. All reports and exported data are date stamped and carry the users name and electronic signature. The system can produced reports including an overview report which list all the sensors or detailed reports showing each sensor, maximum and minimum values reached, tabular and graphical representation of the data and any alarm notifications for that period. Data security For added data security the D3 & D3 Medical have daily automatic data back-up to an integrated industrial grade micro SD card providing 100% data backup. Both normal and backup data can be viewed seamlessly within the system. ºC ºC ºC In addition both the D3 and D3 Medical have an internal battery back-up as standard to provide up to 12 hours operation in case of a power loss protecting against any loss of data. 05

Radio transmitters The D3 wireless sensors cover a comprehensive range of measurements. Our systems supports both our Wireless Temperature sensors and our advanced Intelligent Sensor Ranges. Both types of sensor offer long range operation with user replaceable batteries with excess of 5 years operation. temperature sensors Our standard temperature sensor range offers a cost effective option for monitoring temperature. The sensing technology is built into the radio transmitter. Utilising NTC sensors they offer high accuracy with low drift. We offer two sensor types; Radio transmitter with an internal sensor or a radio transmitter with external temperature sensor on a remote cable. Sensors can be supplied with full UKAS calibration certification. P2-WS100 Internal Temperature Sensor Measurement range: 0 C to +40 C P2-WS101 External Temperature Sensor (transmitter) Radio transmitter with phono connector for use with our External Temperature Probes External Temperature Probes 5K NTC External Temperature Sensors P3-ST200-PC Sensor with 1.5m 2 Core Arctic Cable P3-ST201-PC Sensor with 4.0m 2 Core Arctic Cable P3-ST202-PC Sensor with 1.5m 2 Core F.E.P Cable P3-ST203-PC Sensor with 4.0m 3 Core F.E.P Cable Measurement range: -45 C to 45 C Below -30 C ±0.8 C ±0.8 C -30 C to 45 C Wireless repeaters If the wireless transmitter is not in range of the base station an optional wireless signal repeaters can be used to forward the data message. Repeaters form a mesh to the communication network allowing the base station and sensors to communicate over long distances and in complex structures. P2-WS104 Wireless Repeater Module P2-WS105 Wireless Repeater Module with 12hr battery back-up 06

Intelligent Sensors These high accuracy sensor perform the necessary conversion from the measured factor to digital data which is then sent by the radio transmitter. Each intelligent sensor has its own unique id and contains multipoint calibration data including the date it was last calibrated and certificate number. Intelligent temperature and humidity sensor can be provided with factory calibration to UKAS standard. Intelligent sensors attach directly to single or dual input transmitters. P2-WS102 Intelligent Sensor Wireless Transmitter P2-WS103 Intelligent Sensor Wireless Transmitter Dual Inputs Intelligent sensor range P3-DS300-HR 5K NTC Stub Temperature Probe Measurement range -20 C to 45 C -20 C to 40 C 5K NTC External Temperature Sensor P3-DS301-HR Sensor with 1.5m 2 Core FEP Cable P3-DS302-HR Sensor with 4.0m 2 Core FEP Cable Measurement range: -50 C to 70 C Below -30 C ±0.8 C * -30 C to 70 C P3-DS303-HR PT100 High Temperature Sensor With on 1.5m 3 Core FEP Cable, measurement range: -30 C to 70 C -30 C to 70 C ±0.1 C ±0.1 C * ±0.8 C Below -45 C 07

P3-DS304-HR PT100 Ribbon Temperature Sensor P3-DS305-HR PT100 Ribbon Surface Temperature Sensor -20 C to 70 C With 1.5m PVC 3 Core Ribbon Cable Measurement range: -20 C to 70 C -20 C to 70 C With 1.5m PVC 3 Core Ribbon Cable Measurement range: -20 C to 70 C PT1000 Temperature Sensors P3-DS306-HR Sensor with 1.5m 2 Core FEP Cable P3-DS307-HR Sensor with 4.0m 2 Core FEP Cable Measurement range: -45 C to 100 C Below -40 C -20 C to 70 C 70 C to 100 C ±1.2 C ±0.8 C P3-DS308-HR PT1000 Extended Range Temperature Sensor With 1.5m 2 Core FEP Cable, measurement range: -100 C to 200 C @ -100 C * @ 0 C @ 100 C @ 200 C * *Maximum calibibration range from factory is -45 C to +140 C P3-DS309-HR PT1000 Flexible Extreme Range Temperature Sensor With 1.5m Flexible Mineral Insulated Cable & 1.5m 2 Core FEP Cable, measurement range -200 C to 200 C @ -100 C @ 0 C @ 100 C @ 200 C P3-DS310-HR PT1000 Stiff Extreme Range Temperature Sensor With 300mm Stiff Mineral Insulated Cable & 1.5m 2 Core FEP Cable, measurement range -200 C to 200 C @ -100 C @ 0 C @ 100 C @ 200 C 08

P3-DS311-HR %RH Humidity Sensor Stub Mount Measurement range: 0-95 %RH P7-SA1010 4m Intelligent Sensor Remote Mount Extension Cable available as option @23 C 5 to 25%RH 25 to 75%RH 75 to 95%RH ±2.5%RH ±2.5%RH ±3%RH ±1.5%RH ±2.2%RH ±2.3%RH Linear Input Sensors P3-DS312-HR P3-DS313-HR P3-DS314-HR P3-DS315-HR P3-DS316-HR P3-DS317-HR 0-25mA 0-200mV 0-2V 0-5V 0-10V 0-10K Ω Signal Input Signal Input Signal Input Signal Input Signal Input Signal Input With 1.5m Arctic Cable. Measurement range: as defined above ± 1% over the full scale P3-DS317-HR Pulse Counting Sensor With 1.5m Arctic Cable Minimum pulse requirements Pulse Length >50ms, Pulse Interval >50ms P3-DS318-HR Digital Input Sensor With 1.5m Arctic Cable Minimum measurement period 1 minute 09

D3 Medical P1-D3103 D3 P1-D3102 D3 LITE P1-D3101 Software designed compliancy standard FDA 21 CRF Part 11 requirements for electronics records¹ BRC, HACCP & GMP monitoring system requirements HACCP monitoring requirements Data & Data Storage Internal Memory Storage Period 150 sensors 6 months 75 sensors 1 year 30 sensorsº 2 years 150 sensors 6 months 75 sensors 1 year 30 sensorsº 2 years 20 sensorsº 4 years Data Back-Up Media Integral 8Gb Micro Industrial HD MMC Integral 4Gb Micro Industrial HD MMC Not Available Back-Up Memory Storage Period 150 sensors 4 years 75 sensors 8 years 30 sensorsº 10 years+ 150 sensors 2 years 75 sensors 4 years 30 sensorsº 8 years - Back-Up Frequency Automatic - daily Automatic - daily - Manual Back-Up Via Micro USB connection to a USB connected storage device Via Micro USB connection to a USB connected storage device Via Micro USB connection to a USB connected storage device Battery Back-Up Yes Yes No Operating Time on Battery Back-Up Up to 12 hours during normal system operation Up to 12 hours during normal system operation - Display - Colour TFT with Resistive Touch Screen Yes Yes Yes Maximum Number of Sensor Inputs 150 wireless or hardwired sensors per base station *** 150 wireless or hardwired sensors per base station *** 20 wireless or hardwired sensors per base station *** Resolution of the Sensor Readings Integer to 3 decimal places as required Integer to 3 decimal places as required Integer to 1 decimal place as required Wireless Frequency 433Mhz (Europe) Yes Yes Yes 2.4Ghz (ROW) Yes Yes Yes 433Mhz 1km (typically 250 meters in buildings) 1km (typically 250 meters in buildings) 500m (typically 100 meters in buildings) 2.4Ghz 100m (typically 30-50 meters in buildings) 100m (typically 30-50 meters in buildings) 100m (typically 30-50 meters in buildings) Range Extender available Yes Yes Yes Users & Security Max Number of Users 20 20 5 Network Connectivity Yes Yes Yes 10

Security D3 Medical P1-D3103 D3 P1-D3102 D3 LITE P1-D3101 Username & Passcodes Yes Yes Yes Passcode Expiry Yes Yes No Multiple User Levels Yes Yes Yes Data Storage Rate Automatic - daily Automatic - daily - Browser Security HTTPS Capable HTTPS Capable HTTP Capable Email SSL Encryption Capable SSL Encryption Capable SSL Encryption Capable System Alarms Set Points Upper & Lower Warning & Critical Alarm Set Points Upper & Lower Warning & Critical Alarm Set Points Upper & Lower Warning & Critical Alarm Set Points Alarm Delays Audible Alarm Yes Yes Yes Alarm Email Yes Yes Yes Alarm Acknowledge Yes Yes Yes Alarm Notes 20 notes per alarm 20 notes per alarm 5 notes per alarm Relay Outputs 2 2 2 Alarms over IP Up to 3 IP Address Up to 3 IP Address Up to 3 IP Address Inputs / Outputs Micro USB Output Yes Yes Yes Mini Din Input for External Hardwired Hardware Yes Yes Yes Universal 5v DC power adaptor - 110 to 240v Power Supply Yes Yes Yes * Sensors, wireless transmitters & hardwired connectors available separately ** Existing Tek Troniks 433Mhz DataCentre sensors are compatible with all D3 Base Stations ¹ Meets the standard for storage and review of data when used in conjunction with user defined procedures for FDA21 CRF Part 11 requirements. º Based on the average volume of sensors per system version sold in 2016 11

D3 Medical P1-D3103 D3 P1-D3102 D3 LITE P1-D3101 Height, Width, Depth 175mm (max), 157mm, 40mm (including wall plate) Weight 317 grams (including wall plate & battery back-up) 271 grams (including wall plate) Operating Temperature 0 C to +40 C Storage Temperature 0 C to +50 C Power Supply 5V dc via an external universal power brick (supplied), descrete push button on/off fuction on base station Operating System Embedded Internal Storage Back-up Storage Media 8Gb industrial grade micro MMC 4Gb industrial grade micro MMC - Display Full Colour 480 x 272 Resistive Touch Screen LED Solid Green (main power, no alarms), Solid Red (mains power, with alarms), Flashing Green or Red (on battery back-up, with or without alarms) Solid Green (main power, no alarms), Solid Red (mains power, with alarms) Sounder Built-in buzzer (can be switched off in software) USB Micro USB 2.0 (for manual data back-up) Ethernet Built-in (2 meter cable supplied with unit) Relay Outputs Relay 1: Volt free relay output providing NO & NC contacts Relay 2: Mossfet Switch Mini Din Socket For connection to proprietary external hardware Low Power Radio Module Yes Frequency 433Mhz (UK/Europe), 2.4Ghz (ROW) licence free bands Power 10mW maximum (433Mhz), 14dbm maximum (2.4Ghz) Communications Bi-directional Protocol Proprietary (433Mhz), 802.15.4 Proprietary (2.4Ghz) Battery Back-Up Yes No Type Plug connection lithium ion rechargeable - Power Voltage 3.7V - Capacity 2050mA - Recharge Time - Test Cycle Advise monthly by removing system power - 12

If you have any questions or comments, or want to know how Tek-troniks can help you and your business, please contact us: Call: 0115 989 0090 Visit: tek-troniks.co.uk Manvers Business Park, High Hazles Rd, Cotgrave, Nottingham NG12 3GZ All content 1998-2017 Tek-troniks Limited Registered in England & Wales 5383539 VAT No. 820 2623 70