MOST EFFECTIVE METHOD FOR WIPING A FIBRE

Similar documents

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates

When you need perfectly clean splices & connectors. Sticklers Fiber Optic Cleaners

The True Value of Connector Inspection: New Challenges and Best Practices

Fiber Optic Cleaners When you need perfectly clean splices & connectors

Suits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications

FIBER OPTIC CONNECTOR CLEANERS

Sticklers Fiber Optic Splice &

INDUSTRY STATS SNAPSHOT

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

Fiber Optic Connector Cleaning Solutions

Fiber Optic Connector Cleaning and Inspection Kit Instructions

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

Applications Engineering Notes

Best Practice Briefing

Connections You Can Count On.

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure

White Paper Fiber optic connections: check and clean first, then connect!

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Applications Engineering Notes

Fibre Specification Standards

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector

Cleaning a Fibre Optic Solution

Connecting At The Speed Of Light

FIBER OPTIC CLEANING AND INSPECTION. Dry Cleaning Wet Cleaning Connector Cleaning Kits Inspection Systems

Cleaning of fiber optic connectors

Fiber Optic Products Catalog

The Importance of Properly Cleaning Fiber During Splicing

Connector Maintenance

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Connecting at the Speed of Light. Fiber Optic Cleaning Products

Fiber Optic Cleaning Overview. Prepared by Steve Lytle, Westover Scientific March 10 th, 2004

Advancing Fiber Optic Connectivity

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

Be Mr. Clean! Using Fluids Other than Alcohol When Cleaning Fiber Optic Connectors. By Mike Jones, MicroCare Corp.

Figure 1 - Parts of a Fiber Optic Connector

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

Multi fiber connector: Visual inspection and cleaning guide

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Titel (auf Masterfolie editierbar) Cleaning of Fiber Connectors

Jul07 Rev C

Contemporary Considerations When Precision Cleaning Fiber Optic Connections

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

The FTA-02 Fiber Arranger

Ensuring Cabling Performance in the Customer-Owned Outside Plant

ITU-T L.404. Field mountable single-mode optical fibre connectors

Chargebuster Ion Gun Installation, Operation and Maintenance

SERVICING INFORMATION

Core Alignment All In One Fusion Splicer

Chargebuster Ion Gun Installation, Operation and Maintenance

CONSUMABLES CLEANING SOLUTIONS

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

HIGH POWER FIBER OPTIC PATCHCORDS

User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Chargebuster Ion Gun Installation, Operation and Maintenance

solution simplified order Panasonic ideas for life maintenance solutions

This is a preview - click here to buy the full publication

Keysight 81663A DFB Laser Source Module

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2.

Hydraulic Crimping Head, PN 69069

Fibre optic media options and trends

Requests for Daily Care and Maintenance

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Cleaning the internal optics surfaces

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

TFS-FS1 Optical Leakage Detector. Operation Manual

Hydraulic Crimping Head, PN

LSH (E 2000 ) High performance. High reliability. High safety. High flexibility

Universal Connectivity Platform A Modular Approach to Infrastructure Design

INTERNATIONAL STANDARD

Cleaning Kit Instructions - DTC550 Printer

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

Under Screen Cleaning The Value of a High Performance Cleaning Roll

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

Metal, ceramic, plastic package products

L eather Care & Cleaning

Basic Professional Fiber Optic Installation

White Speckles on the Garment

HW-17 Record Cleaning Machine Setup and Instruction Manual

FOREWORD. Only 3 connector parts makes the assembly process both simple and efficient. CONTENTS. 1. Preparation and tools required for assembly

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

Contents. Introduction... A Note About Heatsinks... Precautions...

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Keysight Cleaning Procedures for Lightwave Test and Measurement Equipment

Thermal Stripper, TSAB-40 User Manual

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

Fiber Optics for Todays Industry Applications

Technical Bulletin. 1405F/DF Switching Valve Maintenance NEW DESIGN Bulletin # TS0062 Rev 05/2016

5 Maintenance. A November

TOYOTA COROLLA BODY SIDE MOLDING Section I - Installation Preparation

ARINC 801 Fiber Optic Interconnects for Aerospace & Defense. A Complete End-to-End Solution Featuring Connectors, Termini & Cable Harnesses

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

FTTc Network Testing Overview

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Transcription:

MOST EFFECTIVE METHOD FOR WIPING A FIBRE Step 1: Pull & fold a new wipe Step 2: Apply the cleaning fluid Step 3: Wipe the fiber in single direction Avoid oversaturating the wipe Insert the fiber into the fold of the wipe after it has been stripped

MOST EFFECTIVE METHOD FOR WIPING A FIBER Step 1: Pull a new wipe into the cleaning window Step 2: Wet one section of the wipe Step 3: Place connector in wet section and wipe towards dry The cleaning fluid breaks up the contamination and dissipates electrostatic charges Using the coloured slots will avoid cross contamination when cleaning additional end faces on a wipe

REASON FOR SINGE DIRECTION WIPE Wiping a fibre or connector back and forth will reapply the contamination you just took off. Wiping a connector in Z-3 or a Figure 8 pattern will reapply the contamination you just took off.

RECOMMENDED OPTIONS FOR WIPING CONNECTORS CLEANWIPES 90 Optical Grade Wipes P/N: WFW Plastic protective tub with no roll hexagon can Use wipes for cleaning connectors & for cleaning fiber for splicing pigtails Sticklers Cleaning Fluid P/N: POC03M (3oz can) P/N: POC 10M (10oz can) Can will not spill nor cross contaminate Use for wet-dry cleaning & fiber splicing Cassette CLEANCLICKER cleaner P/N: CCWRC Microwoven fabric cleaning ribbon Manual advancement of cleaning ribbon Static dissipative medium in cleaning window CLEANWIPES 640 Optical Grade Wipes P/N: WCS640 8 slot cleaning window spaced for LC & SC duplex with static dissipative medium Plastic sealable box Use wipes for cleaning connectors & for cleaning fiber for splicing pigtails

CLEANING IN ADAPTER CONNECTORS WITH STICKS Step 1: Take stick from package Step 2: Tilt cab, pump & wet stick Step 3: Insert stick and rotate 6x to 8x in same direction Light push on the pump will dispense enough cleaning fluid for wetting the stick Taking out 1 stick at a time will prevent cross contamination unused sticks

CLEANING MT FERRULES WITH STICKS Move the stick in a single direction from bottom to top Pushing contaminations across the array and going up and down will damage the fibre arrays

RECOMMENDED OPTIONS FOR WIPING CONNECTORS CLEANSTIXX Optical Grade Sticks 50 sticks in a box Cleans in adapter connectors and socket termini Colour coded handle based on ferrule size 1.25mm p/n S12 1.6mm p/n S16 2.5mm p/n S25 MT p/n XMT Recessed Tip p/n P25 Sticklers Cleaning Fluid P/N: POC03M (3oz can) P/N: POC 10M (10oz can) Can will not spill nor cross contaminate Use for wet-dry cleaning & fiber splicing

WET-DRY CLEANING WITH A MECHANICAL CLEANER Step 1: Wet an optical grade wipe Step 2: Wet an optical grade wipe Step 3: Insert the cleaner and engage Avoid oversaturating the cleaning tip Small amount of cleaning will loosen up contamination and dissipate electrostatic charge

RECOMMENDED OPTIONS FOR WIPING CONNECTORS 1.25mm CLEANCLICKER 400 Cleaner P/N: CCM125 Provides 400 engagements Cleans in adapter & LC, MU ARINC 801 assemblies plus the pin & socket of hardened 1.25mm FTTA assemblies Compact size is fits into confined spaces 2.5mm CLEANCLICKER 750 Cleaner P/N: CCU250 Provides 750 engagements & REFILLABLE Cleans in adapter & multiport drop enclosures & SC assemblies and drop cables MPO CLEANCLICKER 600 Cleaner P/N: CCMPO Provides 600 engagements Cleans in adapter & truck MPO assemblies 1.25mm CLEANCLICKER 750 Cleaner P/N: CCU125 Provides 750 engagements & REFILLABLE Cleans in adapter LC assemblies

CONNECTOR CLEANING AND SOURCES OF CONTAMINATION REASON FOR CLEANING CONNECTORS: Mating dirty connectors will cause scratching and pitting ruining termini end faces Cleaning both end of mated connector pair before mating will extend service life of assemblies and ensure reliability of signals COMMON SOURCES OF CONTAMINATION: Wear debris generated from moving parts when mating connectors Electrostatic charge caused by contact friction from dry cleaning processes Cross contaminated alcohol that has been diluted from atmospheric moisture, lint from paper based wipes, and broken cellular structure of foam tipped sticks Image of dust contaminated end face courtesy of Promet Optics

INDUSTRY STANDARD: WHY IT MATTERS Why should you use industry standards? Interoperability working together with reliability Economies of Scale Open Market Access Drives Innovation Safety What would happen if end users did not follow Industry standards? Products might not work as expected Inferior Quality Incompatibility with other equipment Redistricted to using proprietary sole sourced products

INDUSTRY STANDARD: IEC 61300-3-35 Fibre Optic Interconnecting Devices and Passive Components Basic Test and Measurement Procedures Part 3-35 Examination and Measurements Fibre Optic Connector Endface Visual Inspection and Automated Inspection SCOPE: Provides methods for quantitatively assessing the end face quality of a fiber optic connector Tells you what are allowable defects like scratches, pits and debris can be on ferrule end face without disrupting the optical performance The spec is written for applications using 2W power

INDUSTRY STANDARD: IPC 8497-1 Cleaning Methods and Contamination Assessment for Optical Assembly SCOPE: Describe methods of inspecting and cleaning all optical interfaces so their interconnectivity does not result in loss of optical signal Also describes methods of contamination prevention. Target audience are Manufacturing Operators, Manufacturing Process Engineers, Quality Engineers and Field Systems Installers Why should you care? This standard will make sure your suppliers are manufacturing and shipping you a quality product.

INDUSTRY STANDARD: IEC 61300-3-35 SCRATCH VS DEFECT Section 3 Measurement defines scratches and defects Scratch: Permanent linear surface feature Defect: All non linear features including particulates, other debris, pits, chips, edge chipping

INDUSTRY STANDARD: IEC 61300-3-35 ZONES EXPLAINED Zone D - Contact Zone 130μm to 250 μm Zone C Adhesive Zone 120μm to 130 μm Zone B Cladding Zone 120μm to 25 μm Singlemode 120μm to 65 μm Multimode Zone A Core Zone 25μm to 0 μm Singlemode 65μm to 0 μm Multimode

INDUSTRY STANDARD: IEC 61300-3-35 PROCESS EXPLAINED Connector A Connector B Mating a clean connector to a connector with hard dust or connector wear debris will create scratches and pits on both connector surfaces Dust particles break apart during the mating and migrate towards the apex of the ferrule

INDUSTRY STANDARD: IEC 61300-3-35 PROCESS EXPLAINED The flow chart is from Section 5.3 Inspection Procedure The best practice before mating the connector pair is to: 1. Inspect 2. Clean if Necessary 3. Re Inspect It is important to do BOTH connectors

INDUSTRY STANDARD: IPC 8497-1 PROCESS EXPLAINED The flow chart is from Figure 4.1 Connector End-Face Inspection Row Recommends inspect, clean and re inspect IPC uses the three strikes before changing cleaning methodology

BEST PRACTICE: CLEAN BOTH CONNECTORS Connector A Connector A Connector B Connector B The images show what happens when a clean connector (A) is mated to contaminated connector (B) If you only clean one connector, you cross contaminate both connectors.

BEST PRACTICE: CLEAN YOUR TEST GEAR AND TIPS Most inspection scopes and loss test sets use metal adapters The insertion of metal tips during the testing process will generate wear debris

Dusters Cassettes and Dry wipes Solvent Only Solvent and Wipes Sticks Only Solvent and Sticks Mechanical Cleaners Machines CLEANING OPTIONS MATRIX Patchords Y Y N Y Y Y Y Y In Adapters Y N Y N Y Y Y Y Transceiver lens Y N Y N Y Y Y Y Alignment sleeves Y N Y N Y Y N Y Dust caps Y N Y N Y Y N Y The table is based on Table 7.1 from the IPC 8497-1

WET DRY CLEANING CONNECTORS Cleaning fluid increases the local humidity level allowing static to dissipate Avoid hygroscopic fluids and containers that draw in air to avoid cross-contamination Pre-saturated wipes are vulnerable to contamination from packing materials Use fast-evaporating and high-purity cleaning fluids with optical grade wipes

ISSUES WITH IPA IPA is hygroscopic meaning it attracts water molecules Alcohol dispersers pull in the air during the pump action Very flammable with high vapor pressure

ISSUES WITH IPA

CASE FOR USING STICKS AND CLEANING FLUID 1. CLEANING PERFORMANCE: The use of cleaning fluid breaks up heavy oils and residue contamination The strands in the cleaning tip create a capillary action which wicks up contamination from the end face 2. ELMINATION OF ELECTROSTATIC CHARGE EFFECT: The cleaning fluid becomes the dissipative medium that eliminates the electrostatic charge on the ferrule and connector housing Cleaning with a moisten cleaning stick does not create an electrostatic charge during the wiping process The cleaning stick s tip makes contact with the socket wall during the rotation process which dissipates the electrostatic charge Using the cleaning fluid will ensure compliance to IEC 8497-1 Sect 10

CASE FOR USING STICKS AND CLEANING FLUID 3. LARGEST EFFECTIVE CLEANING REGION: The cleaning stick s tip diameter is able to reach contamination that resides in the outer regions of the ferrule end face Removing contamination from end face periphery significantly reduces particle migration LIMITATIONS OF ALL MECHNICAL CLEANERS: Dry wiping causes an electrostatic charge from the contract friction between the cleaner s cleaning strand flowing across the ferrule end face Wet-dry cleaning is ineffective because the cleaning strand wicks up on both sides of the cleaning strand requiring multiple engages The cleaning tip outer diameter is reduced to prevent contact with socket walls that would interfere with the cleaning strand flow The effective region is < Ø0.6mm for Ø1.25mm ferrule

4 QUESTIONS FOR SELECTING A CLEANING OPTION 1. What kind of contamination have connectors been exposed to? Residues/dust particles/both Light or severe contamination level Material degradation 2. What are conditions like at the work site? Ventilation/air flow Flammability concerns Operating & storage conditions Air quality Atmospheric dust & moisture levels 3. How do the solvents need to be transported? 4. What are regulatory requirements? Need for air shipment Hazmat restrictions No-spill/no-leak containers DOT, restrictions RoHS, GHS & REACH compliance Substance & chemical restrictions

BEST PRACTICE SUMMARY Best Practices for Cleaning Fluids: Use hermetically sealed containers to avoid cross contamination Less is more Dispense just enough to clean a connector Best Practices for Sticks & Swabs: Rotate stick at least 6X in a single direction Limit force to about the same pressure you would use for a writing pen Never excessively scrub the end face to prevent scratching with wear particulates Best Practices for Wiping Connectors: Wipe connectors in a single direction Always wipe MT based connectors (i.e MPO) in a single direction vertical direction Tilt end face for APC so the 8 angle is touching the wipe General Best Practices: Never look directly into a connector with the bare eye Inspect, clean if necessary & re-inspect Reusing wipes & sticks causes cross contamination

For More Information Contact: Brian Teague Product Line Manager Sticklers Fiber Optics C: +1.860.406.2576 briant@microcare.com