... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Similar documents
... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON.... Variante3 Fired Unit Heaters...

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... UDSA - UDSBD Gas fired unit heaters...

AMBIRAD.... Vision Radiant Tube Heating Systems...

Gas-fired unit heaters for indoor installation

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

RHC GAS FIRED HEATING COILS

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

PREEVA air handling unit

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

... DF / IDF Gas fired combined heating and ventilation ...

Warm air heating equipment

DF-IDF air handling units

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

VPC Gas Cabinet Heater Range

RHC & RHCE gas fired heating coils

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

LARGE CAPACITY HEATERS

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

CITY OPEN - CITY BOX from 25 to 35 kw

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

CP+ Gas & Oil Cabinet Heater Range

gas condensing combi boiler

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

FMH Range Hoods. Installation, Operation & Maintenance Instructions

Compact HRE Boiler Range. The smart choice for heating and hot water

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Rapid. Suspended Warm Air Heater. Caring for the environment!

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Heating Systems. An ideal temperature in every pig house

Radiant heating equipment

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Copper-Fin GAS-FIRED WATER HEATERS

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

Tower Green HE Hybrid

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Operating Instructions

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Residential Heating Boilers

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Sirius FS. Working towards a cleaner future

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

advanced : technology

Gas-Fired Unit Heaters Commercial & Industrial

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

THE BURNING ISSUE FOR BODYSHOPS

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

INSTALLATION & SERVICING MANUAL FOR BENSON PV TUBULAR CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Sirius WH. Working towards a cleaner future

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

TopGas Wall Hung Condensing Gas Boiler

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

GAS ABSORPTION HEAT PUMP

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

SGE Condensing Gas - Solar Water Heater

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Ciao Green Condensing Wall-Hung Boilers

We offer ceramic radiant heaters and infra-red radiant tubes.

Gas condensing boiler UltraGas

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Energy-efficient heat source provides comfort in large rooms

Operating instructions

INSTALLATION AND OPERATION MANUAL

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Gas heaters and convectors ROBUR

NOZ2. Multi-Directional Heating & Cooling Solutions

LUH HORIZONTAL FAN-FORCED UNIT HEATER

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Transcription:

... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant

RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the new high efficient RHeco series of energy saving condensing gas fired unit heaters. The RHeco range provides the highest efficiency levels and substantially reduced CO 2 & NO x emissions (under 25ppm). The units exceed the requirements of current Building Regulations L2, with thermal efficiencies up to 109% to provide exceptional levels of seasonal efficiency. Also the extremely low NO x modulating pre-mix burner enables BREEAM points to claimed (when applicable). These 4th generation units utilise tubular primary heat exchanger and a secondary condensing heat exchanger with an aerodynamic profile and 4-pass flue gas circuit. Model Range The RHeco condensing units consisting of five models is available with heat outputs ranging from 25kW to 95kW for use on natural gas or propane. Now available with (optional) modulating supply air fan Features & Benefits > > Thermal efficiency of 100% at full load and up to 109% at minimum load for lower operational costs > > Substantially reduced CO 2 and NO x emissions (under 25 ppm) considerably lower than the emissions of the previous generation of unit heaters, and already exceeding European standards > > Reduced energy bills > > Ideal for new low carbon buildings > > Up to 35% energy saving on replacement heaters > > Burner with new pull through combustion technology. Negative pressure ensures that no gas or flue gas can escape into the heated space > > Versatile flue options (top or rear connections) for ease of installation > > High flow axial fan for a powerful air throw, decreases stratification and improves heat distribution > > 5:1 turn down ratio for close temperature control. Reduced temperature gradients help prevent stratification > > Optional modulating supply air fan (100 to 50%). Full speed when full burner rate, 50% fan speed when burner at 20%. Fan modulates between these two points

...... Advanced Heat Exchanger Technology Superior performance is achieved by using the advanced technology serpentine heat exchanger, along with a tubular primary heat exchanger. As the flue gases pass through the secondary heat exchanger the increased surface area cools the flue gases below 45 O C causing water vapour to condense and release its latent heat This heat, which would normally be lost to the atmosphere via the flue, is instead transferred into the building hence less fuel is used to achieve the same heat output. The high efficiency levels are not dependent on the firing rate and the units are permanently condensing, with constant low flue gas temperatures. This results in far lower energy consumption and carbon emissions compared to other types of condensing units which only achieve comparable efficiency levels at reduced heat outputs. Optimum Economy and Fuel Savings In times of rapidly increasing energy costs, reducing energy consumption makes sense both financially and environmentally since this also significantly reduces CO 2 emissions. Although condensing air heaters require a higher initial capital investment they are very economical and can repay the extra initial cost in fuel savings in 2-4 years depending on usage. When replacing traditional units more than 10 years old, savings of 30% can be achieved. Modulating Fan (optional) An EC modulating fan is available as an option. This fan will automatically modulate down to 50% full speed as the burner modulates. When the burner is at 20% the fan will run at 50% (see graph below). Use of this option will increase the leaving air temperature of the unit when on low fire, thus reducing the risk of cold draughts being created. Applications > > Automotive workshops > > Factories > > Retail outlets > > Sports facilities and halls > > Warehouses > > Workshops Condensate trap Units are fitted with an internal condensate trap keeping the installation neater and quicker for the installer. 3000 2500 2000 Comparative Energy Consumption Graph showing relationship between burner firing rate and fan speed for optional modulating fan Burner firing rate 80% 60% 40% kw/h 1500 1000 100% 20% 50% 500 0 Traditional heater High efficiency RHeco ECA listed condensing heater heater Enhanced Capital Allowances The Government s Enhanced Capital This symbol verifies that the product has Allowance scheme actively encourages been independently assessed and qualifies industry and commerce to reduce energy for the ECA scheme, an upfront tax relief consumption by promoting the use of enabling businesses that invest in energysaving equipment to claim 100% first-year energy efficient equipment. The high thermal efficiency of RHeco units (up to capital allowances against their taxable 109%), significantly exceeds the 101% profits. threshold for Enhanced Capital Allowances. 88% 75% 63% Fan speed rate

Primary Heat Exchanger Manufactured from high quality corrosion resistant steel, the entirely new primary heat exchanger reduces thermal stress for enhanced life expectancy. This tubular heat exchanger is welded to the burner box using the newest robotic welding technology to form a highly resistant and durable assembly. Secondary Heat Exchanger The secondary heat exchanger is manufactured using high quality corrosion resistant materials, the non-welded design of the heat exchanger reduces thermal stress for enhanced life expectancy. This heat exchanger constitutes the second part of the flue gases which condenses in a 4-pass circuit in order to release their latent heat. The streamlined aerodynamic profile of the secondary heat exchanger results in minimal resistance to airflow to give longer throws and improved air distribution, which reduces energy consumption. Originally, used as a primary heat exchanger in other Reznor unit heaters, this proven design is now integrated into the RHeco's new assembly as a secondary heat exchanger. Traditional unit heater Higher roof space temperatures increase heat loss through roof Shorter air throws reduce air distribution efficiency and require longer pre-heat times RHeco heater Reduced floor to ceiling temperature gradients Longer air throws provide even heat distribution and reduce pre-heat times Venter fan The flue fan provides a negative pressure that ensures that gases can not escape and can only be exhausted through the flue system. The aluminium corrosion resistant flue fan is housed in a separate compartment. Units are fully room sealed to prevent dirt or dust from entering the combustion system. A differential pressure switch shuts down the unit in the vent of inadequate air, blocked flue or flue fan failure

Flue spigot supplied as option at point of order. Air Distribution A high capacity axail flow fan is fitted to all units for improved air throw and reduced stratification. The fan operation is controlled by an integral controller which delays the fan start up until the heat exchanger has reached operating temperature and continues to run the fan after the burner has switched off until all useful heat has been dissipated. An optional modulating supply air fan may be fitted to heaters. This will allow the fan speed to automatically modulate between 100 to 50% (burner will be at 20% when fan runs at 50%). Once 50% has been reached the fan will no longer modulate downwards. Please note that the use of destratification fans is strongly recommended when choosing a modulating supply fan An optional economy thermostat may also be fitted to heaters installed at high level to recirculate warm air down to working level when the burner is switched off. Horizontal flue spigot supplied on all models as standard. Controls To further maximise efficiency, the RHeco unit is equipped with integrated controls that allow 5:1 modulation. The reduced temperature gradients will prevent stratification. Electrical Components All electrical components are accessible from one side of the unit heater through a full width hinged door. The electrical components are housed in the same compartment as the flue fan in order to facilitate installation and service. Condensate Drain All units are supplied with an internally fitted condensate trap. A single 32mm dia connection at the rear of the heater for condensate disposal Modulating Burner Modulating burner technology utilises a single low NO x burner, with multi-try ignition for optimum reliability and ease of maintenance.

......... Installation Units may be suspended or alternatively mounted on a suitable non-combustible support. Four integral suspension points complete with an M10 female thread are provided to each heater. The balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall or roof outlet. Additional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted.) Enhanced Reliability and Safety A microprocessor burner control provides full safety monitoring and multi-try ignition control for enhanced reliability. Limit stats monitor the operating temperature within the heater unit and shut down the burner in the event of overheating. For additional safety all models are fitted with dual limit stats. A differential pressure switch shuts down the unit in the event of inadequate combustion air, blocked flue or flue fan failure. Ease of Maintenance All controls are accessible from a single side and are housed behind a hinged door, situated on the left hand side of the unit when viewed from the rear. The hot gas exhaust fan is housed in a separate adjacent compartment. To comply with CE approvals, balanced flue appliances must be used with the manufacturer s balanced flue system. The units are also certified for fan assisted flue installations, where the combustion air is to be drawn from within the heated space; an alternative wall or roof terminal is required for this application. A single phase electrical supply is required to each unit. This supply should not be switched off except for maintenance. Units must not be installed in atmospheres containing highly flammable or explosive vapours, combustible dust, halogenated hydrocarbons or chlorinated vapours. They are also unsuitable for areas where contaminants may affect electrical motors or connections. Condensate Drain Required Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing Condensate Drain Required Balanced flue roof outlet (type C32) A condensate drain must be installed in accordance with local regulations. Condensate traps are supplied with each heater, additional pipework must be supplied by the installer. Condensate Drain Required Condensate Drain Required Combustion air through wall, flue Separate combustion air and flue pipes outlet through the roof (C52) (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table Heater positions and flue arrangements are indicative. For heater and flue clearances please refer to our sales leaflets.

......... SmartCom Environmental issues dictate that buildings need to operate as effectively and efficiently as possible. Initiatives such as the Climate Change Levy and the subsequent introduction of the Government s Energy Technology List (ECA scheme), together with upgrading Part L of the Building Regulations, have resulted in consulting engineers, contractors and end users becoming increasingly energy conscious. Reznor SmartCom, the intelligent energy management controller satisfies the growing need for higher efficiencies and to complement the development of energy efficient heating systems. Touch of a Button To complement the high efficiency RHeco units a versatile range of SmartCom control panels are available. > > Self-adapting optimum start and stop > > Simple user-friendly programming > > Individual seven day programming > > Day, night and frost (5 C) temperature settings > > Three on/off periods per day > > Easy set overtime and holiday periods > > Remote burner reset facility Multi-zone Control Allows up to 16 units to be centrally controlled. Functions controlled by the master unit include: > > Clock updating > > Updating temperature functions and programme settings > > Viewing the current temperature and target > > Setting holiday, overtime and vent only functions for the entire network > > Centralised burner lock out reset Simple to program and operate, SmartCom 3 provides cost-effective energy management for small single heater installations through to large multi-zone applications requiring centralised control. Technical Data Additional Control at the > > Password protection to prevent unauthorised adjustment > > Hours run and service data logging > > Battery back up in the event of mains failure > > High / low or modulating burner control (Multi-zone version req 1. Natural gas G20 calorific value 10.48k W/m 3 GCV, inlet gas pressure maximum 50mbar, minimum 17.5mbar. Propane G31 calorific G31 value 14.0k W/ kg GCV, inlet gas pressure maximum 50mbar, minimum 37mbar. 2. Throw is dependent on mounting height, building height, room temp and louvre settings. Isothermal conditions @20 o C ambient air temp, discharge louvre zero deflection. v=0.5m/s 3. Measured @ 5m from unit with Q=2, A=160m 2 4. Not supply size 5. To underside of heater. Downturn nozzles are recommended for units installed at highjer mounting heights. For units fitted with optional modulating supply fan, air re-circulation fans are strongly recommended. 6. Only applicable to units fitted with optional modulating fan Model 025 035 050 075 100 Maximum heat output kw 25.0 32.7 49.4 69.2 93.8 Minimum heat output kw 5.5 7 11 15.3 20.2 Maximum thermal efficiency at maximum heat input % 98.30 98.00 98.60 98.60 98.60 Maximum thermal efficiency at minimum heat input % 109.2 108.8 108.7 106.5 108.9 Gas Consumption 2 at maximum Natural gas G20 m 3 /h 2.59 3.39 5.07 7.27 9.76 heat input (1) Propane G31 kg/h 1.99 2.60 3.93 5.51 7.47 Gas Consumption 2 at minimum heat input (1) Natural gas G20 m 3 /h 0.55 0.69 1.09 1.52 2.00 Propane G31 kg/h 0.4 0.51 0.8 1.12 1.47 Air volume (15 o c) m 3 /h 2900 3700 5600 7900 10500 Temperature rise at max load o C 25 26 26 26 26 Horizontal throw (2) m 20 23 30 30 36 Sound pressure level (3) db(a) 44 49 52 47 58 Sound pressure level - min speed (3),(6) db(a) 38 34 35 35 40 Maximum absorbed power W 200 300 500 600 1240 Gas connection (4) Rc ½'' ½'' ¾'' ¾'' ¾'' Electrical connection 230/240 V 1N-50Hz Flue and combustion air connection size mm 80 80 80 100 100 Condensate Quality I/h 1.3 1.5 2 2.5 3.5 Recommended Mounting height 4 m 3 3.5 3.5 4 4 Net weight kg 112 129 141 197 243

Dimensions Model ULSA 025 ULSA 035 ULSA 050 ULSA 075 ULSA 100 Unit height A 885 885 885 885 885 Unit length (max) B 1217 1217 1216 1274 1215 Unit width C 738 738 865 1177 1433 Base to gas inlet D 222 222 222 222 222 Top to air inlet E 231 231 231 203 203 Top to flue outlet F 351 351 351 343 343 Side to air inlet and flue outlet G 135 135 140 143 143 Flue and combustion air collars Ø mm 80 80 80 100 100 Suspension centres H 449 449 576 860 1144 I 760 760 760 760 760 J 105 105 105 105 105 K 55 55 50 78 50 Top clearance 100 100 100 100 100 Rear clearance 400 400 400 500 500 Bottom clearance* 100 100 100 100 100 Side clearance 100 100 100 100 100 Service panel clearance 820 820 820 820 820 *Heaters may be base mounted directly onto non-combustible supports adequately sized to support the unit weight Front View Plan View Rear View G C 1 2 J I K E F A H 4 D B 5 3 1. Combustion air inlet 2. Flue connection 3. External Gas Connection GB/REZ/RHE/004/0901 4. Electrical connections 5. Condensate drain dia 32mm female NORTEK GLOBAL HVAC (UK) LTD Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United Kingdom Tel: 01384 489 700 01384 489 707 reznorsales@nortek.com www.reznor.eu Registered in England No. 01390934 Registered Office The Colmore Building, Colmore Circus Queensway Birmingham B4 6A Nortek Global HVAC is a registered trademark of Nortek Global HVAC Limited. Because of continuous product innovation, Nortek Global HVAC reserves the right to change product specification without due notice.