MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Similar documents
M-Switch Float Operated Liquid Level Switch

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Mobrey MCU900 Series Universal Control Unit

Rosemount 3100 Series Ultrasonic Level Transmitters

Mobrey ultrasonic Liquid level detection systems

Rosemount 3100 Series Ultrasonic Level Transmitters

Mobrey Magnetic Level Switches

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2100 Series

Rosemount 3490 Series

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Level gauges Series LS Level indicator, switch and transmitter for liquids

Ultrasonic Point Level Switches

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 ATG

Ultrasonic Switches. Features & Benefits

Rosemount 2090F Hygienic Pressure Transmitter

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Annubar Flowmeter Series

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2090P Pulp and Paper Pressure Transmitter

Laser Level Measurement Products. Introducing the New LLT100

Rosemount 752 Fieldbus Remote Indicator

High Pressure Conductivity Monitor

MICROSENSE FLOW SWITCH

Model 144H. Product Data Sheet , Rev DB February Content

Level Measurement Continuous level measurement - Ultrasonic transmitters

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter

Advanced Level Seminar 2015

Rosemount 2120 Vibrating Fork Liquid Level Switch

Dräger Polytron 7000 Fixed gas detector

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

OPTIBAR DP 7060 Supplementary Instructions

Mobrey electronic probes

Mobrey ultrasonic liquid level detection systems

Rosemount 4500 Hygienic Pressure Transmitter. Start

Dräger Polytron 8000 Stationary gas detector (EC)

Continuous level measurement Ultrasonic transmitters

Rosemount 2140 and 2140:SIS Level Detectors

Level Measurement Continuous level measurement Ultrasonic transmitters

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Installation and Operating Instructions

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Continuous level measurement - Radar transmitters

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Model 144H. Product Data Sheet , Rev DB February Content

Quick Start Manual July pointek CLS100

Flow Measurement SITRANS F C

Absolute and Gage Pressure Transmitter

SET-2000 Hi Level/Oil

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

Rosemount 2110 Level Switch

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 2130 Level Switch

Dräger Polytron 8310 Stationary gas detector (DSIR)

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Rosemount 3051L Level Transmitter

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Sanitary Pressure Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Electronic Pressure Digest. Pressure and Temperature Transmitters

Instrumentation and Controls Group

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Dräger Polytron 5100 EC Detection of toxic gases and vapors

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

E C H O T E L C O N T A C T U L T R A S O U N D

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

OilSET-1000 (12 VDC)

industrial electronics electronic level measurement system

Flange immersion heaters

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Fill Point, Level Gauges, and Control Range

PRODUCT LINE QUICK REFERENCE. Worldwide Level and Flow Solutions SM

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Rosemount 2088 Absolute and Gage Pressure Transmitter

LC1350 Level Controller

Rosemount 3051S Electronic Remote Sensors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8200 Stationary gas detector (CatEx)

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Dräger Polytron 8100 EC Detection of toxic gases and vapors

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Ultrasonic Level Measurement nivopuls FDU 10 S

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Transcription:

Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either a tank mounted sensor or pipe section with integral sensors Rugged 316 stainless steel sensors for in-tank or pipe section mounting Simple keypad operation, and intuitive menu based programming Dual operating frequency sensors 1MHz to 3.3MHz MSM400 Contents MSM400 Control Unit and Sensors...................................... page 2 Specifications...................................................... page 3 Dimensional Drawings................................................ page 4

MSM400 Product Data Sheet MSM400 Control Unit and Sensors Measuring range up to 50% solids Configurable display and output functions 4 20 ma HART output, and 2 x SPDT control relays Automatic de-sludge control routines Additional Information MSM400 Control Unit and Sensors Specifications: page 3 Dimensions: page 4 TABLE 1. MSM400 Control Unit Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description MSM400 Control unit, ATEX intrinsically safe certified, IP65 Typical Model Number: MSM400 TABLE 2. MSM400 Sensors Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description MSM433 Tank mount MSM448 Pipe mount Approval A Intrinsically safe (ATEX) Size (1) 100T 1 / 3.3 MHz 4 in. (100 mm) gap tank sensor 150T 1 / 3.3 MHz 6 in. (150 mm) gap tank sensor 200T 1 / 3.3 MHz 8 in. (200 mm) gap tank sensor 300T 1 / 3.3 MHz 12 in. (300 mm) gap tank sensor 450T 1 / 3.3 MHz 18 in. (450 mm) gap tank sensor 100 1 / 3.3 MHz flanged PN10/PN16 DN100 pipe sensor 150 1 / 3.3 MHz flanged PN10/PN16 DN150 pipe sensor 200 1 / 3.3 MHz flanged PN10 DN200 pipe sensor A10 1 / 3.3 MHz flanged ASME B16.5 Class 150 4 in. (100 mm) pipe sensor A15 1 / 3.3 MHz flanged ASME B16.5 Class 150 6 in. (150 mm) pipe sensor A20 1 / 3.3 MHz flanged ASME B16.5 Class 150 8 in. (200 mm) pipe sensor Spray Valve V Spray valve (pipe section only) P No spray valve (pipe section only) Cable 7 23 ft. (7 m) cable D Customer specified cable length up to 330 ft. (100 m) length must be clearly stated on order Typical Model Number: MSM448 A 150 V 7 (1) Sensor size is specified depending on the application. Please contact the sales office to ensure that the size is suitable for the application. 2

Product Data Sheet MSM400 Specifications CONTROL UNIT General Product Connections Conduit Entry Cable Termination Sensor Frequency Current Input Trigger Input ma Output Relay output Electrical External Power Supply Environment Operating Temperature Enclosure Rating Approval Hazardous Area Wall Mounted MSM400 Control Unit 3 x M20 glands and 2 x M16 glands Captive screw terminal block. Maximum cable size 2.5mm 2 / 12 AWG 1 MHz or 3.3 MHz auto selection 4 20mA Volt free contact 5V logic 4 20mA into 1000 ohms max. 2 x SPDT rated up to 5 A, 250 Vac resistive 115 or 230 Vac (50/60Hz), or 24 Vdc 22 to 130 F ( 30 to 55 C) IP65 ATEX II (1) G, EEx ia IIC MSM433 SENSOR General Product Connections Mounting connection Sensor Cable Environment Operating Temperature Operating Pressure Approval Hazardous Area MSM433 Tank Mounted Gap Sensor, 316 Stainless steel ¾-in. BSPT. Gap size 4, 6, 8, 12, or 18 in (100, 150, 200, 300, or 450 mm) 23 ft. (7m) dual screened twisted pair (others upon request) Cable junction box: Sensor IP68 40 to 130 F ( 40 to 55 C) -- 212 F (100 C) upon request 1522 psi (105 bar) ATEX II 1 G EEx ia IIC T6 MSM448 SENSOR General Product Pipe Section Material Drain Fitting Connections Mounting connection Sensor Cable Cable Junction Box Environment Operating Temperature Operating Pressure Approval Hazardous Area MSM448 Pipe Section Gap Sensor Epoxy coated carbon steel 1-in. NPT Flanged in-line installation DN100, DN150, DN200 to BS4772, PN10 rated or 4 in., 6 in., 8 in. ASME B16.15 Class 150 23 ft. (7m) from junction box, oil hose protected, dual screened twisted pair (others upon request) IP65 Aluminium alloy 40 to 158 F ( 40 to 78 C) 145 psi (10 bar) ATEX II 1 G EEx ia IIC T6 3

MSM400 Product Data Sheet CONTROL UNIT Dimensional Drawings Note: Dimensions are in inches (mm) 8 (203.5) Internal Wall Mounting Holes 1.3 (33.35) 3.1 (80) 0.5 (12.5) 8.8 (224.2) 9.3 (236.7) 4.1 (104.2) 0.2 (4.2) 4 (100) 6 x Mounting Holes 0.2 ( 0.5) 8.9 (226.5) 9.5 (241.5) 10.1 (256.5) SENSORS Note: Dimensions are in inches (mm) 18 (455) Location Pin Retaining Nut 1-in. BSP For Flush Valve Fitting O Ring Sealing Face R¾-in. (BS21:1973) ¾-in. BSPT 2.4 (61) 4 (102) Gap = 6 (150) 0.9 (22) 1-in. NPT Drain Fitting 1.2 (30) Specify Gap Size 4 (100) to 18 in. (450 mm) 1.2 (30) 4

Product Data Sheet MSM400 5

MSM400 Product Data Sheet 6

Product Data Sheet MSM400 7

MSM400 Product Data Sheet Mobrey Level Solutions Emerson provides a wide range of Mobrey products for level measurement applications. POINT LEVEL DETECTION Vibrating Fork Liquid Level Switches For high and low alarms, overfill protection, pump control, including wide pressure and temperature requirements, and hygienic applications. Flexible mounting. Immune to changing process conditions and suitable for most liquids. Mobrey Mini-Squing (Compact) Mobrey Squing 2 (Full-featured) Ultrasonic Gap Sensor Liquid Level Switches For use in non-hazardous industrial processes to detect high or low liquid levels and liquid interface. Immune to changing density, and wide dielectric and ph variations. Suitable for use in most clean and non-aerated liquids, with options for sludges and slurries. Float and Displacer Liquid Level Switches Mobrey electromechanical float and displacer level switches are ideal for alarm and pump control duties, especially in critical applications or hazardous areas. Mobrey Horizontal Level Switches Mobrey Vertical Level Switches Chambers are available for external mounting of these level switches on process vessels. Dry Products Level Switches For high and low level alarms. Including threaded mounting connections, extended lengths, high temperature capability, and multiple detection techniques. Suitable for a wide variety of powders, granules, and free flowing solids with wide variations in bulk densities. Mobrey VLS Series Vibrating Rod Level Switch Mobrey PLS Series Paddle Level Switch Mobrey CLS Series Capacitance Level Switch CONTINUOUS MEASUREMENT Ultrasonic Continuous Level Transmitters and Controllers Top mounted, non-contacting for simple tank and open-air process level measurements. Unaffected by fluid properties such as density, viscosity, dirty coating, and corrosiveness. Intrinsically Safe versions are available for operating in hazardous areas. Mobrey MSP Series Ultrasonic Level and Flow Transmitters Mobrey MCU900 Series Universal Controllers Ultrasonic Sludge Density Blanket Monitoring and Control Ultrasonic in-line pipe or tank mounted sensors for sludge density measurement and control, and top mounted ultrasonic sensors for continuous measurement of sludge blanket level in Industrial and Municipal effluent treatment processes. Mobrey MSM400 Sludge Density Monitor Mobrey MSL600 Sludge Blanket Level Monitor Displacer Continuous Level Measurement Top mounted in a vessel or externally mounted in a vertical chamber. For use in hazardous areas. Mobrey MLT100 Displacer Level Transmitter Hydrostatic Continuous Level Transmitter For level measurements in non-pressurized tanks where in-tank problems such as foaming, vapor layers, and temperature gradients prohibit the use of other instrumentation. Mobrey 9700 Series hydrostatic electronic level transmitters SPECIALIZED CONDUCTIVITY Conductivity Water and Steam Interface Monitoring Steam/water interface level gauges using specialized, high performance conductivity probes in external columns and manifolds, ideal for steam plants where reliable and redundant indication of boiler water level and turbine protection is critical. Hydratect 2462 Water/Steam detection Systems Hydrastep 2468 Water/Steam Monitoring Systems The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a registered trademark of Rosemount Inc. Mobrey is a registered trademark of Mobrey Ltd. All other marks are the property of their respective owners. Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale 2012 Mobrey Ltd. All rights reserved. International: Emerson Process Management Mobrey Measurement 158 Edinburgh Avenue Slough, Berks, SL1 4UE, UK T +44 (0)1753 756600 F +44 (0)1753 823589 www.mobrey.com Americas: Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 906 8889 IP257 01/12