Alert-it Care Systems

Similar documents
P163BBA Radio Enuresis Alarm Monitor

P162B Radio PIR Motion Detector

P163BBA Wired Enuresis Alarm Monitor

P162A Wired PIR Motion Detector

Alert-it Care Systems

mini Wireless Epilepsy Support

P137 Advanced Pager. Supervisor Handbook. P137BAA(64 Channel), P137CAA(8 Channel)

Congratulations on your Alert- it purchase

Companion Monitor Handbook. Radio Companion Bedside Monitor Solutions S1026C/S1026D (including Plesio Pager)

SMARTWALK DEMENTIA WANDERING SYSTEM

Telecare Equipment Guide

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

Solution Ultima Series Operators Manual ISSUE 1.00

ULTRASONIC OIL LEVEL MONITOR & ALARM

WIRELESS SIGNAL UNIT FEATURES

Quick Touch Pendant User Guide

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

Guardian Instruction Manual

Digital Electronic Thermostat With RF

Solution Ultima 862 Operators Manual ISSUE 1.10

User s guide Personal radio trigger Erik 9100

External Wireless Sounder

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Finally, an affordable wireless call bell system for smaller facilities

Supervised Security System Owner's Guide

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Smart Hub. User & Installation Guide

169MHz Telecare Devices Companion Epilepsy Monitor

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

External Wireless Sounder

Wireless Keypad GKP-S8M

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

MK9 series CarePhone. Installers Mauual

Digital Electronic Thermostat With RF

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Wireless Keypads LKP(E)S8M Series

SMOKE User Manual. NE v2.0

Secure WANDERING INSTALLATION AND USAGE GUIDE

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

ezone Alert System ezone is a UK designed and manufactured care alerting system unlike any other comparably priced system.

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Silversphere Wireless Series

Solution 880 Operators Manual. Issue 1.00

Touchpad Exit Controller Administration Guide

Lifeline Vi Clever, not complicated

Engineer Paging. Staff Paging. Deaf Alert.

L900 series USER MANUAL

Temporary wireless battery operated fire system from Channel Safety Systems

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

D1265. User's Guide. Touchscreen Keypad

Version 1.03 January-2002 USER S MANUAL

Responder IV Wireless Bed Interface User s Guide

Salamander User Guide

Alarm System SECURE AS 302

Wander Management Solutions

Total Connect Box. User manual

WIRING DIAGRAM AND INSTRUCTIONS

Architectural and Engineering Specification for a Real-Time Locating System Flare

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

English. Doro CareIP Mobile. User Guide

Solution 844 Operators Manual ISSUE 1.10

Remote alarm unit Art. Nr.:

1. Introduction. 2. Product overview

169MHz Telecare Devices Carbon Monoxide Detector

MEDICAL ALERT SETUP GUIDE

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Consultant Specification AGILE Wireless Fire Detection System

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

-Tag. BodyGuard. Driver Awareness System SAFETY SOLUTIONS. Installation Guide. BodyGuard Safety Solutions A division of Orbit Communications Pty Ltd

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

HILLS Series LED Code Pad User Manual

169MHz Telecare Devices Heat Detector

User Manual. Non-contact Infrared Thermometer.

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Solution 6+6 Wireless - AE Operators Manual ISSUE 1.10

3 ZONE WIREFREE BURGLAR ALARM INSTALLATION & OPERATING INSTRUCTIONS

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Digimax 210. Programmable Thermostat Compatible with Maxi Controller. User Guide

USER GUIDE HARDWIRED CONTROL PANELS

Product Catalogue Carephones and Telecare solutions for independent living

UV Flame Supervision System

Personal Assistance System Owner s Manual

GSM RFID VOICE Alarm System

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

MLS. ALPHA-PAGE-LT v5.3. Contact monitoring-paging system. installation/owners manual #AP-LT53. Micro Logic Systems. phone 866-MLS-FREE

Total Protection Alarm System

Quantec NURSE CALL. Nurse call system & dementia care from Channel Safety Systems

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Destiny Destiny Owners Manual

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

THE BELLMAN & SYMFON WAY Visit technical training

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Shed Alarm Kit. User Manual

Wireless Central Monitoring Unit

CSP-204 CSP-208 CSP-104 CSP-108

New Silent Alert Fire Safe System

SCORPION Z16040C, Z8040C and Z5120C

Transcription:

Alert-it Care Systems P135 Personal Alarm Alarm Badge User Handbook P135AB P135AA Models covered by this handbook Long range personal monitor badge Short range personal monitor badge One of a range of Alert-it Care Alarms available from:

This handbook is intended to assist carers install, configure and use the monitors. The carere therefore needs to understand the needs of the user and asses that the monitor meets those needs and if any supplementary monitoring is needed taking into account any health risks. The P135A is a miniature badge style monitor that is capable of sending alarms to the P137/P138 Safelink Pagers or P117C Telephone Autodialler, and is especially suited to those living alone or in a supported environment. It can also be coupled to established Nurse Call systems via our P155 Radio Alarm Receiver. Typical range outdoors is 100m for P135A or 450m for the P135B The alarm can be programmed to detect 1. User pressing the front call button 2. User falling to an angle of 60º or less (even if they continue to have seizre activity) 3. User risking hypothermia (special programmed option) 4. User wandering too far from pager (see pager programming manual) Power for P135 The badge is powered by a replaceable lithium button cell battery which should last more than a year in fall mode (&2) or 4 weeks modes 3 or 4. A spare battery is included with the unit. A card of 5 batteries is available from its Designs Ltd (order code P160) To prevent the fall alarm activating in the post, the P135 is shipped in a deactivated state. The HELP button must be pressed until a beep is heard to activate the unit for the first time. (The same procedure is needed after battery replacement) UH1101A P135 User Handbook page 2 of 8

Typical System Configurations The P135 Badge uses radio to transmit an alarm when a fall is detected or the panic button is pressed Optionally the P135 can make a regular transmission which is used by the P137/8 pagers to prove the integrity f the radio network and can be used to detect wandering outside a safe area. The regular transmissions will reduce battery life The P137/8 pagers will give full details of battery and alarm status. It can also use the regular Safelink transmission to warn of wandering or radio failure The P155B Radio Receiver can connect to a Nurse Call system or an autodialler (as shown). The receiver shows successful radio reception by the flash of a green light. It will warn of radio failure when the Securelink protocol is enabled by a red light and audible alert UH1101A P135 User Handbook page 3 of 8

Installation Fall Detection: The unit should be clipped to clothing using the rear clothing clip or pin, in a position that best fits the anticipated fall condition. Clipping to the waist band is an excellent place that is unobtrusive and capable of detecting a full fall with few false alarms. For those prone to slumping while seated then clipping to the upper torso is recommended. This also gives easier access to the panic button. In situations where a drop will not occur (eg watching Tv in an armchair) the user is advised to hold the badge and throw it or drop it when a seizure starts It is also possible to stand the unit up on a nearby coffee table and kick/knock it over when a seizure starts False alarms will be caused if the user lies down to rest while wearing the badge Panic Only The badge can be supplied to special order without the fall detection., to act as a simple panic badge (with the potential of hypothermia or wandering detection). This version can be fitted with a lanyard. Wandering Detection For this to work the unit must be set into Securelink mode (see page 8). This makes the badge transmit are radio signal every 10 seconds which can be used to check approximately how close the badge is to the pager. The battery life will be reduced in this mode. The pager is first put into learn mode where by the weakest radio signal strength is recorded while the badge is carried around the care home. The transmissions can be forced to occur faster by pressing the HELP badge quickly (less than 1 second to save setting the alarm). This should be done at all the recognised extremities. The recorded values are then saved as the wander detection value and the pager returned to normal use. If the radio strength falls below this saved value then a WANDER alarm is indicated. This automatically cancels once the badge is back within the limits. The method of detection is not a precise concept (as GPS) and some level of false alarms may occur. However it is cost effective, convenient system and unlike GPS based systems it will work quickly when the user exits a building. If the user escapes out of range completely, then the RF Fail warning will appear after 2 minutes as a further level of protection. The detection value can be adjusted manually on the pager if false alarms occur. For information about pager programming see the P137 Programming Handbook. UH1101A P135 User Handbook page 4 of 8

Installation (cont) Hypothermia Detection This version uses an internal temperature sensor to guage the ambient temperature around the client. An alarm will be raise if this temperature falls below 12 C for more than 1 hour. These parameters can be adjusted to order. Range test. If the unit has the failsafe feature enabled, then the pager will automatically warn if the regular radio transmission is lost. If this is not the case then the badge should be tested in all the usual locations to prove signal reception. A short press on the HELP button (less than 1sec) will cause the P135 to transmit, without setting an alarm In large installations a more convenient method is to have one P135 with the failsafe capability enabled (see below). This is then positioned where the pager would normally be situated and the pager taken around the whole area to be monitored. Any loss of signal is then apparent when the pager fails to show reception of the test badge signal (when the name stops flashing onto the display every 10 seconds) UH1101A P135 User Handbook page 5 of 8

Operation Regular Battery Test In the non-failsafe mode the battery will last up to a year, but should be checked regularly by making a short press of the Panic Button (less than 1 second so that no beep sounds). If the battery is serviceable than the light will flash. The P135 will also transmit at this time. In Securelink mode the battery status is being monitored continually. If FAULT 30 or 31 shows on the P137/8 pager, or the P117 autodialler gives an intermittent audible alarm and activates the fault alarm message, then the battery will need replacing. The P135 will continue to function for some hours (but with a slow flash of the light every 8 seconds), allowing time for this replacement. If the battery is exhausted then the P135 will chirp continuously without the light flashing or transmitting. In a fall When the P135 is made horizontal then after 15 seconds an audible pre-warning will start and the red light will flash. The initial, silent delay prevents false alarms during normal movements. The pre-warning tone decreases in pitch over 30 seconds (to assist those with impaired hearing). If the user does not return to the upright position during this period, then the tone stops and the full alarm is transmitted. The red light continues to flash to indicate the latched alarm Use of HELP button Pressing the panic button for 1 second will produce a short beep and an ASSIST alarm will be sent immediately. The red light will then flash to indicate the latched alarm status. Clearing the alarm If the panic button is pressed for 1 second, while any alarm is active (the red light flashing), then, after a short beep, the alarm will be cleared. This is noted by the light extinguishing UH1101A P135 User Handbook page 6 of 8

Turning off the Badge Operation (cont) The badge contains a small magnetically operated switch which can be used to turn off the badge, for instance at night. The magnet is passed over the front of the unit, and the alarm light is noted to blink. The unit is turned back on by pressing the HELP button until there is a beep heard. Alarm indication at the pager/receiver Alarm Detect Delay Pre-warn P135 Pager P155 /P117C Panic 1 second No Flash Assist 01 Intermittent tune + alarm Fall 30 sec 15 sec Flash Urgent 01 Continuous tune + alarm Hypothermia 1hour No Flash Urgent 02 Continuous tune + alarm Wander 10 sec No No Wander Intermittent tune + alarm Escape 2 min No No RF Fail Intermittent tune + alarm TEST Less than 1 sec No Flash Node Name Green light flash Battery Low Battery Fail Battery Dead - - Flash every 8 sec - - Flash every 8 sec Fault 30 Fault 31 The P135 chirps every 0.5 sec with no LED and no transmission Intermittent tune, + alarm Intermittent tune, + alarm UH1101A P135 User Handbook page 7 of 8

Maintenance Cleaning The badge is IP61 rated and capable of being cleaned to Alert-iT Method Technique B Technique B Battery Replacement (see diag page 10 ) The anticipated battery life is shown below Wiping with cotton wool pads moistened (compressed until dripping stops) with a mild detergent (0.5% washing up liquid) solution. Operating Mode No failsafe heartbeat, no alarms Using failsafe heartbeat, no alarms Maximum alarm number 1 Battery capacity 1 year 1 month 2000 alarms 1 Based on fall alarms with 2 minute response time from carer Failsafe Operation An internal link selects failsafe Securelink mode Remove the link for maximum battery life, but note the warnings that alarms may be missed if the radio path is interrupted or the badge fails. Add the link to create the highest integrity systems. To change the link, open the case and remove the battery as described on page 10 and fit the link as shown below to enable Securelink. To remove Securelink simply Link enables Securelink operation. If not required then remove for maximum battery life Programming and enabling failsafe operation UH1101A P135 User Handbook page 8 of 8

Maintenance remove the link and store by fitting to one pin only. Refit the battery. This is an essential step as the link is activated when the battery is enabled. Close the case and enable the battery by pressing nthe HELP button until a beep is heard Configuration Changes The P135 uses the standard Alert-iT Programming Data Protocol and all the main features can be changed using the P152 USB Interface and Data Editor Programme. Communication Address Changes Each badge in a care home MUST have a different communication address. To facilitate easy installation the Communication Address can also be changed directly from the pager using the P173A programming cable UH1101A P135 User Handbook page 9 of 8

Maintenance (cont) Open the case carefully buy pulling apart without twisting, after unscrewing the one rear fixing screw Aerial coil In all the following procedure be careful not to damage the aerial coil Use a small screwdriver, match, cocktail stick or similar implement to start the ejection of the battery from its holder. Then pull clear of the housing Remove and then replace the battery (note the + side is upwards). Battery Type: 3v Lithium Coin Cell CR2025 or equivalent (order code P160 for 5 batteries) Reassemble the case. The P135 must now be activated by pressing the red button for 1 second until a beep is heard UH1101A P135 User Handbook page 10 of 8

Safety Instructions and Warnings! This symbol indicates there are warnings and precautions associated with the use of this equipment that should be carefully read and understood before using the equipment. 1. Clean and disinfect each item regularly in accordance with information herein 2. Regularly test as described herein 3. Ensure, by testing, that the alarm is annunciated at the carer's location(s) 4. Charge pager away from direct heat and uncovered. 5. As with all medical electronic equipment there is potential for the equipment to interfere with or be effected by interference from other electrical or electronic devices. For this reason avoid placing the monitor, sensor or connecting cable in close proximity to sensitive electronic devices or devices which produce strong electromagnetic fields such as radio transmitters, mobile phones or power cables. 6. If the equipment is modified in any way, appropriate inspection and testing must be conducted to ensure continued safe use of the equipment. 7. The carer must conduct a risk assessment to determine if the level of reliability offered by the monitor is sufficient or if additional monitoring is needed. Contact the manufacture for assistance with Risk Evaluation Tools. 8. Ensure the badge and any associated parts do not come into the possession of vulnerable patients who might choke on them 9. The monitor and all accessories are designed to operate indoors in a residential environment of 10ºC to 30ºC and 90%RH max. 10. The fall detection requires the user to lie in a semi prone position. Some falls may not achieve this and hence if the user is at high risk in a fall, there should be frequent observations made on their well being The Alert-it system has been designed with due regard to reliability and integrity. While it offers a highly vigilant monitoring method,it is always possible that a distress condition can go undetected for a variety of reasons (including malfunction) and in life threatening situations it is advisable to use the Alert-it system in conjunction with additional monitoring techniques (e.g. video). Neither the manufacturer nor its agent can accept legal responsibility to provide a system that is infallible. The carer is responsible for assessing the risks of using this equipment and any settings pertaining to it. UH1101A P135 User Handbook page 11 of 8

This system is certified to the following European Standards 93/42/EEC: 2007/47/EC 1 EN 300 220-1 V2.1.1 (2006-04) EN 14971:2007 EN 61010-1:2005 EN12182:1999 EN 61010-1-2:2004 Also complies with 2002/95/ECRoHS Class 1 Medical Device Permitted radio transmission Risk Assessment Safety Assistive Technology EMC Permitted Materials 1 Alert-it Care Alarms are social aids designed and manufactured in accordance with 93/42/EEC as Class 1 Medical Devices. They are intended to improve the vigilance of carers to distressing side-effects of various diseases, such as Epilepsy and Dementia. They do not monitor vital physiological processes and should not be expected to diagnose any disease or predict the onset of any symptoms. Additional Documents Quick Start P135 with Pager Quick Start P135 with Autodialler P137 Configuration Handbook UQ1131 UQ1130 UH1068C You tube Instruction Videos Index UV1198 Support For technical support please fax or EMail: HELP: 0845 2179951 FAX : 0845 2179953 Support@itsdesigns.co.uk Designed by: ITs Designs Ltd Leicester LE9 9FE UK...using technology to care for carers UH1101A P135 User Handbook page 12 of 8