Richard Hiles ClimateMaster

Similar documents
Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

Geothermal. Comfort Systems

Geothermal Comfort Systems

Geothermal Heat Pump Systems

AFFORDABLE RENEWABLE CLEAN

HEAT CONTROLLER, INC. HSS Series 1 1/2 to 5 Tons Indoor Split System Geothermal Heat Pumps

HEATING COOLING HOT WATER PRODUCT LINE

Residential Geothermal Technology. Eco-$mart, Inc. Distributed by: TOLL FREE:(888) FAX:(941)

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Geothermal Case Study

GEOTHERMAL: THE SMARTER CHOICE

Residential Application/Design Manual

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

GEOTHERMAL COMFORT SYSTEMS

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Geothermal Comfort Systems

FORCED AIR + HYDRONIC

Reinventing Energy Efficiency

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications

Refrigeration/Troubleshooting Manual

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Geothermal HIGH EFFICIENCY HEATING & COOLING. the logical choice for energy efficient residential heating and cooling

KLDJ : Task 2 Farm Bill Geothermal Heat Pump Template Appendix A. Appendix A Engineering Design

Vapor-Compression Refrigeration

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

Agent - Manufacturer of Boreal geothermal heat pumps

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

Summary Comparison of Simulation Program Features

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Technical Development Program

GEOTHERMAL HEAT PUMPS

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

THERMAL ICE STORAGE: Application & Design Guide

2. CURRICULUM. Sl. No.

That s why we call it Smarter from the Ground Up.

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Multi-Positional Vertical Combination

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

APPLICATION GUIDE BEAMS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

CHAPTER 4. HVAC DELIVERY SYSTEMS

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

GEOTHERMAL DESIGN GUIDE

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

RECORD SUBMITTAL COVER SHEET

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

HYDRO-TEMP. Earth Coupled Heat Pumps HYDRO-TEMP CORPORATION P.O. BOX HWY 67 S POCAHONTAS, AR 72455

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Appendix I. Geothermal Heat Pump Design and Installation Standards October 1, 2001

THE TRANQUILITY 16 COMPACT (TC) SERIES

COMMERCIAL PRODUCT LINE

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

ENGINEERING. Edition No. 13 October 2002

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Air-Cooling Evaporators

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Variable Refrigeration Flow Systems Overview 10/11/2016

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

CTI Sponsored Educational Program

Commercial load calculator instructions (all measurements are imperial)

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

THE GEOTHERMAL CONCEPT CLIMATEMASTER

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

The ultimate fresh air solution.

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

Energy Use in Refrigeration Systems

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

Submitted to Reference Approval Construction Unit Designation Schedule #

HVAC 101. H V A C S y s t e m s

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Product Line Introduction. Karl Zhang Technical support engineer

Variable Refrigerant Flow (VRF) Systems

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Air Conditioning Clinic

Transcription:

Minnesota Geothermal Heat Pump Association 2012 Properly Sizing Ground Source Heat Pump Systems Richard Hiles ClimateMaster

Objective Properly Size and Select GSHP System for Low Operating Costs And Proper Control of Indoor Air Conditions

Solar Energy is Absorbed by the Earth 100% 17% reflected by clouds. 6% reflected by surface. Space 19% absorbed by water vapor, dust Atmosphere U.S. Dept. of Energy 4% absorbed by clouds. 46% absorbed by ground Earth The earth is like a solar battery absorbing nearly half of the sun s energy. The ground stays a relatively constant temperature through the seasons, providing a warm source in winter & a cool heat sink in summer.

Heat Is Transferred Through an Earth Loop Plastic pipe is buried in the earth around the building Insulating layer of earth When liquid is pumped through the pipe, it transfers energy with the earth around it 40-70 F

Sizing Procedures Calculate Building / Zone Heating / Cooling Loads Select Geothermal Heat Pump/s for Building / Zones Design Ground Loop System Using a Software Program Run Operating Costs Comparison Using a Software Program Verify Dehumidification in Cooling Mode Check Effects on Ground Loop System by Unit Size

Objectives: Building Loads Residential Heating and cooling loads are required for each zone / area that will have a ground loop system Residential - Manual J load Calculation Room by Room loads for duct sizing & CFM Total Zone or Building loads for Equipment Selection Cooling Load MUST Include Sensible and Latent Loads

Objectives: Building Loads Residential Various Software Programs to Calculate Loads Input Data Outside Walls Input Windows HTG Input Windows CLG

Objectives: Building Loads Residential Windows Cooling Select Type Direction Shading CLG HTM

Objectives: Building Loads Residential Doors, Ceiling, Floors & Infiltration Input Doors Input Ceilings Input Floors Infiltration

Objectives: Building Loads Residential Loads Subtotals HTG Internal Gains CLG CFM

Objectives: Building Loads Residential Heating and Cooling Loads Total Design Conditions Heating Load Cooling Sensible Latent Total

Objectives: Select Heat Pumps Residential Units are Normally Selected for Heating Load in Northern Climates Size Unit by the Dominate Load / Heating or Cooling Select 2 Stage High Efficiency Geothermal Units Unit Should Cover Approximately 95% of Annual Heating Requirements Must Check Sensible and Latent Cooling Capacity Use Manufacturers Software Program!!

Objectives: Select Heat Pumps Residential Packaged Units in Upflow Downflow Horizontal Split Units Water to Water

2-Stage Copeland UltraTech Compressor Solenoid Valve AC/DC converter unloading control Same Footprint as Single Speed Compressor Thicker Shell than R22 Version Anti-rotation Device to Insure Quiet Operation Solenoid Switches Speed R-410A Compressors Have Lower Failure Rates than R22

Copeland UltraTech /Two-Stage Unloading Scroll With Copeland Scroll UltraTech, two internal bypass ports enable the system to run at 67% part-load capacity for better efficiency and humidity control. Based on demand, the modulation ring is activated, sealing the bypass ports and instantly shifting capacity to 100%. Take advantage of shift on the fly stage changing (no stopping and starting required like other two-stage compressors). Gas By-pass - Ports Open Ports Closed

Objectives: Select Heat Pumps Commercial Unit Selected by Dominate Load / Typically Cooling in Commercial Applications Select Geothermal High Efficiency Units Unit Net Sensible Cooling Capacity Must Meet or Exceed Sensible Cooling Load - Verify Heating Capacity and Latent Capacity Dual Capacity Machines are Recommended Units Rated by ARI standard 13256-1 Reheat option for humidity control

Objectives: Select Heat Pumps ARI/ISO 13256-1 GLHP Ratings are at 77*F EWT for Cooling and 32*F EWT for Heating

Objectives: Select Heat Pumps Commercial Commercial applications may require larger capacity products, rooftop units, console products or vertical stack products.

Objectives: Select Heat Pumps Residential Units are Rated at AHRI Conditions Units Need to be Selected at Maximum and Minimum Loop Design Temperatures Typically 30*F Minimum Entering Water Temperature (EWT) & 95*F Maximum EWT

Objectives: Select Heat Pumps Check Spec Catalog Data at Design EWT 3 Ton Heating Example 3 Ton Cooling Example

Objectives: Select Heat Pumps Residential Water to Water Radiant Floor Heating Comfort Levels

Objectives: Select Heat Pumps Residential Water to Water Radiant Floor Install

Objectives: Water to Water Typical Installation

Objectives: Water to Water W to W with W to A Units

Objectives: Select Heat Pumps Residential Water to Water Equipment Rated at GLHP or GWHP Load / Heated Water at 86*F EWT & 104*F Source at 32*F EWT or 50*F EWT

Objectives: Water to Water / 3 Ton Select Unit by Capacity at System Peak Conditions 30*F EWT Source & 3 GPM / Ton and Leaving Load Temperature & 3 GPM / Ton

Objectives: GeoDesigner for System Design

Objectives: Job Info / Load Info

Objectives: Main Screen, Utilities and Select System Types

Objectives: Select Heat Pumps Software Building Design Loads / Example

Objectives: Select Geo Unit, Loop Type and H2O Heating Method

Objectives: Select Heat Pumps Software Program Select Unit Via Drop Down Menu Packaged, Split or W 2 W Units

Objectives: Select Heat Pumps Software Percentage of Annual Heating Load / 4 Ton

Objectives: Select Heat Pumps Software Percentage of Annual Heating Load / 5 Ton

Objectives: Select Heat Pumps Software Percentage of Annual Heating Load / 6 Ton

Objectives: Select Heat Pumps Software Operating Cost / 4 Ton Versus 5 Ton

Objectives: Select Heat Pumps Software Operating Cost / 5 Ton Versus 6 Ton

Objectives: Select Heat Pumps Software Operating Cost 5 Ton Geo VS Gas AC & ASHP

Objectives: Select Heat Pumps Latent Capacity Typical Indoor Humidity Levels Maintained at 50/55% RH

Objectives: Select Heat Pumps Latent Load Determine Latent Cooling Load Latent Load = Total Minus Sensible 31,289 27,826= 3,463 Latent

Objectives: Select Heat Pumps Check Spec Catalog Data at Design EWT Cooling 5 Ton at 1825 CFM Latent = TC SC 69,440 48,100 = 11,340 LATENT CAPACITY

Objectives: Select Heat Pumps Software Cooling Run Time for Dehumidification 50% Run Time?

Dehumidification Feature Unit Sized for Full Heating/Oversized Cooling

Dehumidification Feature Unit Sized for Heating/Oversized Cooling

Objectives: Select Heat Pumps Software: W to W Select Unit Via Drop Down Menu

Objectives: Select Heat Pumps Software Operating Cost / 5 Ton W 2 W Versus 5 Ton W to A

Objectives: Design Loop System Common Information Loop Design Basic Design Rules 3 GPM Per Ton of Equipment Pressure / Temperature Ports on ALL Units 1-3/4 PE Circuit per ton / 3 GPM 1 1/4 or 2 PE Pipe for Supply & Return Reverse Return Header for Equal Flow

Objectives: Design Loop System Complete a Site Survey Establish Which Type of Loop Will Work best for This Design Follow Check List on the Geo Site Survey Form Plan a Completed As Built Drawing for Entire Ground Loop

Objectives: Design Loop System Common Information Complete the Questionnaire Determine Proper Location and Method for Building Entry with Supply & Return Piping System And Location of Pump Station

Objectives: Design Loop System Reverse Return Loop Design

Objectives: Design Loop System Vertical One bore per ton Vertical Loops Bore hole spacing 10 ft minimum One circuit at 3 GPM flow per ton for ¾ and 1 circuits U-Bend pipe sizes ¾ & 1 ID ASTM PE3408 HD Geothermal PE pipe Many states require bentonite grouting Some locales restrict drilling Bore Hole Depth (typical) North 150-300 ft/ton South 200-450 ft/ton

Avg Depth Avg Depth Avg Depth Objectives: Design Loop System Software Program Input Building Loads When Loops are shallower than one ton per loop One Pair Two Pair Series/Parallel One Pair

Objectives: Design Loop System Vertical Drilling Pipe Loop Insertion Heat Fusing Pressure Testing

Multiple Hole Vertical Loop Supply & Return Piping exit straight out from building foundations- 10 feet min. Header Pit should be 10 feet min. from building foundation Simple drawing shows typical bore hole/circuit layout. Actual Header Manifold less than 24 long. Parallel circuit piping 3/4 & 1.0 dia. Pipe sizes

Objectives: Design Loop System Vertical One bore per ton Bore hole spacing 10 ft minimum One circuit at 3 GPM flow per ton for ¾ circuits 1280 / 5 Tons = 255 Feet of Bore per Hole Our 5 Ton Design with Vertical Loops 5 Circuits at 510 FT each

Objectives: Design Loop System Horizontal Horizontal Loops Backhoe or trench excavation Backhoe used in areas with rock Loop Piping installed below frost line ¾ & 1 ID PE3408 HD PE pipe 1 circuit per ton using ¾ and 1 circuits 3 gpm flow/ton Pipe per ton North 600 ft - 1200 ft South 700 ft - 1800 ft

1 ft 2 ft 2 ft 2 ft Objectives: Design Loop System Software Program Input Building Loads 2 ft 2 ft 2 ft Two-Pipe Four-Pipe Six-Pipe Back-Hoe Loops Two-Pipe Four-Pipe Extended Slinky Trenched Loops

Objectives: Design Loop System Trenching Pit Loops Horizontal Boring

Four-Pipe Horizontal Loop Supply/Return Pipes Exit Perpendicular to Foundation Wall Header Pit Min. 10 ft. from Wall Typical Trench/Circuit layout 24 Maximum Header/Manifold Parallel Circuit Design 3/4 or 1 Circuit Pipe

Objectives: Design Loop System Horizontal Trench Our 5 Ton Design with a 4 pipe Horizontal Loop OPTION # 1 Backhoe or trench excavation 1 circuit per ton using ¾ circuits 8 feet AVG Depth 870 total feet / 2 = 2 trenches at 435 feet each 4 Circuits at 900 FT each OPTION # 2 1 circuit per ton using ¾ circuits 870 total feet / 3 = 3 trenches at 290 feet each 6 Circuits at 600 FT each

Objectives: Design Loop System Software Program Slinky Horizontal and Bore Loops

Objectives: Design Loop System Horizontal Bore Our 5 Ton Design with a Horizontal Bore Loop Horizontal Bore 1 circuit per ton using ¾ circuits 15 feet AVG Depth 1,100 total feet / 5 = 5 trenches at 220 feet each 5 Circuits at 440 Ft each

Objectives: Design Loop System Pond / Lake Least expensive ground loop Lake or Pond Loop Minimum 1/2 acre and 10 feet deep Pond should be within 400 of structure In North - need ice cover for good operation Utilizes 39 F water temp (no aeration). Stagnate water body works best for heating Pipe footage per ton / circuit North and South 400 ft -500 ft/ton 3/4 ASTM PE3408 HD PE pipe

Objectives: Design Loop System Pond / Lake Concrete Blocks for weight Input Building Loads Rev erse Return Header 3 foot separation Heavy Duty Plastic Safety matting Ny lon Cable Ties to secure blocks Ny lon Cable Ties to secure Netting and bricks 4 ft between coils 300 ft coil per ton separated by scrap pipe 8-10 Bricks for weight 300 ft slinky coil per ton Traditional Coiled Pond Loop - Southern Climates High Effic ienc y Slinky/Matt Pond Loo p - Northern Climates

Lake Loop Coils on Rack

Objectives: Design Loop System Pond / Lake Plate Heat Exchangers Floating Coils

Pond Loop Layout Supply/Return Pipes Exit Perpendicular to Foundation Wall Typical Trench/Circuit layout Extended Reverse Return Header/Manifold Parallel Circuit Design 3/4 or 1 HD PE3408 pipe

Objectives: Design Loop System Pond / Lake One Circuit per ton Some spacing required between coils or slinky Lake or Pond Loop USE - One circuit per Ton at 400 FEET and 3 GPM flow per ton for ¾ circuits 2000 / 5 Tons = 400 Feet of PE Pipe per Circuit w 5 Total Heating Dominant Loads in a Northern Climate Should USE 400 Feet of ¾ PE Pipe per Ton / Not 300 / Ton Minimum 1/2 acre / 24,000 SQ FT and a MINIMUM of 10 feet deep

Quick Connect Test Caps Examples (McElroy Mfg.)

Water Side Of System Flow Controller / Pump Station

Water Side Of System Non Pressurized Pump Station

Objectives: Select Loop Circulator Pumps Pump Selection Pump Selection Verify 1 or 2 Pump Flow Controller 1 Pump = 3 Ton Unit 2 Pump = 3.5 to 6 Tons Minimum Flow of 2.25 GPM / Ton Verify Reynolds Number at 2500 Min. Use Pressure Drop Software Program Flush Cart Capable of Proper Flow

Objectives: Effects on Loop Software Total Bore 4 Ton, 5 Ton VS 6 Ton

Objectives: Select Loop Circulator Pumps Vertical Example with Methanol

Objectives: Select Loop Circulator Pumps Vertical Example with Propylene Glycol

Objectives: Select Loop Circulator Pumps Horizontal 4 Pipe w 4 Circuits Example

Objectives: Select Loop Circulator Pumps Horizontal 4 Pipe w 6 Circuits Example

Objectives: Select Loop Circulator Pumps Lake Loop w 4 Circuits Example

Objectives: System Performance Evaluation Each Unit MUST Have Proper Startup

Objectives: Building Loads Commercial Commercial - Calculate Building Loads using ACCA Manual N or ASHRAE Method Zone loads are used to select heat pumps Peak block load is used to determine bore loop depths Heating and cooling loads are required for each zone / area that will have a ground loop system Commercial Building Load Profile is Normally Cooling Dominate

Objectives: Building Loads Commercial UNIT LAYOUT- PERIMETER AND CORE DESIGN Perimeter Units Core Units Central Pump

Objectives: Building Loads Commercial CENTRAL PUMP STATION APPLICATION SUCTION FROM CLOSED LOOP EXPANSION TANK DISCHARGE TO CLOSED LOOP AIR SEPARATOR SUCTION DIFFUSER CENTRIFUGAL PUMP TRIPLE DUTY VALVE

Objectives: Loop Design / Basic Commercial RUNOUT Commercial Loop Layout CIRCUIT or BORE

Objectives: Loop Design / Basic Commercial USE Peak Building Load for Loop Size / AEFLH Four Time Periods Annual Equivalent Full Load Hours

Objectives: Loop Design / Basic Commercial Unit Sized to Peak Zone Load Equipment Selection

Objectives: Loop Design / Vertical Loop Data Borehole Depth System Flow Rate GPM Optional Hybrid Design with Fluid Cooler or Boiler

Objectives: Finance Module Life Cycle Analysis Conventional System Inputs System Types System Efficiency

Objectives: Finance Module Life Cycle Analysis Geothermal System Inputs System Types System Efficiency

Objectives: Finance Module Life Cycle Analysis Annual Energy Savings 25 YR Total Example

Objectives: Finance Module Life Cycle Analysis Full Life Cycle Cost Data 25 YR Total Example

Independent Systems

Central 2-Pipe Constant-Speed

Central 2-Pipe Variable-Speed

Central 1-Pipe Primary/Secondary

Central 1-Pipe Primary/Secondary

% System kwh Example: Pumping Energy Comparison 0.500 0.450 0.400 0.350 Pumping Option Unocc Occ 0.300 0.250 0.200 0.150 0.100 0.050 0.000 Ind Sys 2P-24hr 2P-Clock 2P-low F 2P-VS 1P-P/S Cl 1P-P/S VS

Check Effects on Ground Loop System by Unit Size Sizing Procedures Calculate Building / Zone Heating / Cooling Loads Select Geothermal Heat Pump/s for Building / Zones Design Ground Loop System Run Operating Costs Comparison Using a Software Program Verify Dehumidification in Cooling Mode

Questions? Thanks for Your Time!