Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Similar documents
Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

We measure it. testo 316-Ex CH 4 testo 316-1

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

CO warning instruments and gas spillage detectors

testo 316-EX gas leak detector Instruction manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

testo Leakage detector for gas Instruction manual

Pressure measuring instruments

GfG s EXOTECTOR has been tested for EX-protection by DMT (BVS) Dortmund

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

User Manual. GPD 3000 e. gas detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Dräger X-am 5000 Multi-Gas Detection

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detector

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Dräger X-am 5000 Multi-Gas Detector

ALTAIR 5X Multigas Detector

Dräger X-am 2500 Multi-Gas Detection

Measurement Solutions for Refrigeration Technology.

Dräger X-am 5000 Multi-Gas Detection

PERSONAL COMBUSTIBLE GAS DETECTOR

T.ex Single Gas Detector VISA

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

IMR IX176 Portable Gas Detector User Manual

FIRST CHOICE CATERING SPARES LTD DIGITAL TECHNOLOGY APRIL 2015 FS

Measurement Solutions for Refrigeration Technology.

Hygrometer / Air Quality Meter

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Polytector III G999 for Ex zone 0

1.1 Definitions of alert icons. For your safety

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Monitores Personales. Personal Monitor

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

ALTAIR 5X Multigas Detector Product Specification

Dräger X-am 7000 Multi-Gas Detection

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

LS1. Operator Manual. Kane International Ltd

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

COMBUSTIBLE GAS LEAK DETECTOR PEN

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

IT S WHAT S INSIDE THAT

MICRO IV. Operation Manual. Single Gas Detector

Dräger Polytron 5700 IR Detection of flammable gases and vapours

MICRO III (G202 / G202s / G212) Single Gas Detector

Datalogging as standard

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

GasAlertMicroClip X3 Specifications

Micro III (Models G203, G203S, and G213) Operation Manual

Visit us at

Danfoss gas detection units

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

NGD8800 USER S MANUAL

Safe Operation Manual. Honeywell IQ Force Gas Detector

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

SIMRAD GD10PE IR GAS DETECTOR

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

QD6310. Fixed Gas Detector Operation Manual

Transmitters/Sensors. OLCT Series

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Operating Instructions Compur Monitox plus

Micro IV Operation Manual

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

intrinsically safe detector for hydrocarbon gases

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

SENSIT HXG-2d Combustible Gas Detector

CD100A COMBUSTIBLE GAS DETECTOR

GS100M Gas Detection Controller

Danfoss gas detection unit Type GD Heavy Duty

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Dräger X-am 2500 (MQG 0011) Technical Manual

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

multi-gas detector Go the distance, and save Wear yellow. Work safe.

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Dräger X-zone 5500 Area Monitoring

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

IT S WHAT S INSIDE THAT COUNTS

Dräger Polytron 8310 IR Detection of flammable gases and vapour

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

YOUR PARTNER IN FIRE & GAS DETECTION

GAS ANALYSIS / DETECTION Gas Detector

Danfoss gas detection units

SENSIT PROPANE GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Microtector G333. Operation Manual. Worldwide Supplier of Gas Detection Solutions -1-

Transcription:

Gas leak detectors For a quick overview testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-Ex CH4 C3H8 H2 Gas leak testing Over and over again, devastating explosions and fires are caused by leaky gas pipelines. However, even smaller leaks in the gas pipelines, some of which cannot be detected by odour, lead directly to higher consumption and, in the long run, increase the risk of accidents. Fast testing Thanks to technological developments, it is today possible to use a test instrument to carry out a gas pipeline test (leak quantity test) in a very short time. If a leak is determined, the site of the gas leak can be identified very quickly and reliably with the help of the gas leak detector. How do leaks occur? Leaks can be caused, for example, by hairline cracks (cracks which are hardly identifiable with the naked eye) in the pipelines. The often used hemp sealant can also, after many years of use, become leaky.

Overview Testo gas leak detectors Measuring instrument testo 317-2 testo 316-1 testo 316-2 testo gas detector testo 316-EX The convenient gas leak detector for beginners The detector for leaks in natural gas pipes The gas leak detector with integrated pump for fast check measurements Gas detector Gas detector with EXprotection Meas. range 0 to 20.000 ppm CH 4 0 to 10,000 ppm CH 4 to 4,0 Vol. % CH 4 1 to 999 ppm CH 4 0,1 to 4,4 Vol. % CH 4 0 ppm to 2.5 Vol. % CH 4 0 to 10.000 C 3 to 1,9 Vol. % C 3 1 to 999 ppm C 3 0,1 to 1,9 Vol. % C 3 0 ppm to 1.0 Vol. % C 3 to 4,0 Vol. % H 2 1 to 999 ppm H 2 0 ppm to 2.0 0,1 to 4,0 Vol. % H 2 Vol. % H 2 Lower response thresholds 100 ppm CH 4 50 C 3 100 ppm 1st alarm limit 10.000 ppm CH 4 5000 C 3 (20% LEL) from 200 ppm CH 4 (LED yellow) 200 ppm CH 4 100 ppm C 3 200 ppm H 2 2nd alarm limit from 10.000 ppm CH 4 (LED red) 10.000 ppm CH 4 5.000 ppm C 3 10.000 ppm H 2 Resolution 8 segment trend display LED (3 colour) 18 segment bar display ppm display 4 h (LR03) > 5 h 6 h > 8 h to 10 h audible signal Semi-conductor sensor Earphone socket extendable probe Inherently safe sensor according to DMT Protection class IP54 EU guideline 94/9/EG (ATEX) 2004/108/EG EX-protection II 2G EEx ib IIC T1 (Ex Zone 1)

The convenient gas leak detector for beginners testo 317-2 Highly practical gas leak detector for fast checks on gas pipe connections, with visual bar display. testo 317-2 gas leak detector including case with belt clip and wrist strap and batteries Part no. 0632 3172 Optical bar display Sensor self-test after switching on Rising alarm tone with increasing gas concentration Continuous tone when alarm threshold is exceeded Audible confirmation of readiness to operate Battery monitoring with optical display Meas. range 0 to 20.000 ppm CH 4 0 to 10.000 C 3 Lower response thresholds 100 ppm CH 4 50 C 3 1st alarm limit 10.000 ppm CH 4 (20% LEL) 5000 C 3 (20% LEL) Storage temp. -20 to +50 C Oper. temp. -5 to +45 C 5 s 60 s 2 batteries type micro AAA 1.5 V (LR03) audible signal (85 db(a)) 4 h (LR03) 300 g 2 years conditions see internet page 8 segment trend display

The detector for leaks in natural gas pipes testo 316-1 The testo 316-1 gas leak detector quickly detects even the smallest leaks. testo 316-1 electronic gas leak detector with flexible probe and battery Part no. 0632 0316 Flexible measurement probe for inaccessible pipes TopSafe case protects from dirt and impact (optional) Audible alarm if limit value is exceeded Optical alarm Meas. range 0 to 10,000 ppm CH 4 Lower response thresholds 100 ppm 1st alarm limit from 200 ppm CH 4 (LED yellow) 2nd alarm limit from 10.000 ppm CH 4 (LED red) Storage temperature -20 to +50 C Operating temperature +4 to +45 C LED (3 colour) 5 s Oper. humidity 0 to 95 %RH 30 s 9V block battery Semi-conductor sensor > 5 h Approx. 300 g 2 years conditions see internet page 190 x 57 x 42 mm (without sensors) Accessories Part no. Accessories for measuring instrument testo 316-1 testo 316-1 TopSafe; protection case, incl. stand, protects from dirt and impact 0516 0189

The gas leak detector with integrated pump for fast check measurements testo 316-2 testo 316-2 electronic gas leak detector with flexible measurement probe, mains charger and earphones Part no. 0632 3162 The testo 316-2 is extremely user-friendly and ideally suited to fast check measurements thanks to its integrated pump, its optical presentation of the gas concentrations detected, and the integrated rechargeable battery. Optical and audible alarm with bar display for increasing and dangerous gas concentrations Trend display shows maximum leakage Integrated pump Flexible measurement probe for inaccessible places Earphone connection for secure leakage localization in loud surroundings High duration of use thanks to rechargeable battery Measuring range to 4,0 Vol. % CH 4 to 1,9 Vol. % C 3 Lower response thresholds to 4,0 Vol. % H 2 1st alarm limit 2nd alarm limit 200 ppm CH 4 10.000 ppm CH 4 100 ppm C 3 5.000 ppm C 3 200 ppm H 2 10.000 ppm H 2 Storage temperature -25 to +60 C Operating temperature -5 to +50 C 18 segment bar display Oper. humidity 20 to 80 %RH 2 s NiMH battery 60 s 6 h Earphone socket 348 g 190 x 57 x 42 mm (without sensors) 2 years conditions see internet page Accessories Part no. Accessories for measuring instrument testo 316-2 Earphones, black, with ear cushions Mains unit 12V / DC / 300 ma Case for secure storage of measuring instrument 0554 5001 0554 1093 0516 0191

Gas detector testo gas detector testo gas detector incl. flexible probe extenstion, rechargeable battery and mains unit for mains operation and battery recharging, with calibration protocol Part no. 0632 0323 Testo's gas detector is a multi-range gas detector for the gas types methane, propane and hydrogen. Gas concentrations are measured by the semi-conductor sensor in the ppm range and are shown in the display with a resolution of 1 ppm. Audible signals if approaching lower explosion limit Continuous tone and warning in display if explosion limit is reached Flexible probe extension for difficult-to-access points Measuring range 1 to 999 ppm CH 4 0,1 to 4,4 Vol. % CH 4 1 to 999 ppm C 3 0,1 to 1,9 Vol. % C 3 1 to 999 ppm H 2 0,1 to 4,0 Vol. % H 2 Lower response thresholds Resolution Storage temperature -25 to +70 C Operating temperature -15 to +40 C 2-3 s 40 s NiMH battery, 1600 mah extendable probe Inherently safe sensor according to DMT > 8 h 320 g 190 x 40 x 28 mm ppm display 2 years on instrument 1 year on sensor conditions see internet page

Gas detector with EX-protection testo 316-EX testo 316-EX, electronic gas leak detector with EX-protection, incl. batteries, cases, Allen key and calibration protocol Part no. 0632 0336 Proof of gas and leakage localization on gas pipes and installations in indoor and outdoor areas The testo 316-EX, which conforms to the guideline 94/9/EG (ATEX), is a multi-range gas detector for the gases methane, propane and hydrogen. The gas concentrations are measured by the semi-conductor sensor in the ppm range and are shown in the display with a resolution of 1ppm. Flexible measurement probe for inaccessible pipes 1 ppm resolution on display Indicator suppression for comfortable locating of the leak 94/9/EG (ATEX) conform Measuring range 0 ppm to 2.5 Vol. % CH 4 0 ppm to 1.0 Vol. % C 3 0 ppm to 2.0 Vol. % H 2 Trigger threshold 1 ppm 1 ppm 1 ppm Resolution Storage temperature -10 to +50 C Operating temperature -10 to +40 C Approx. 200 g 135 x 45 x 25 mm Oper. humidity 20 to 80 %RH (not condensed) Protection class IP54 Voltage supply t 90 2 x 1,5 V (Mignon) / AA Type permitted for use in areas with danger of explosion: Camelion Plus Alkaline LR6 (see order data, order no. 0515 0316) to 10 h 14 s EU guideline 94/9/EG (ATEX) 2004/108/EG EX-protection II 2G EEx ib IIC T1 (Ex Zone 1) 2 years on the instrument 1 year on the sensor conditions see internet page Accessories Part no. Accessories for measuring instrument testo 316-EX Spare battery Camelion Plus Alkaline LR6 (AA), 1.5 V / 2600 mah 0515 0316