Infrastructure Technology

Similar documents
SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Ceram Guide to Slip Resistance Tests

Australian/New Zealand Standard

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number:

Slips: framing the issue

Global Safe Technologies (Australia) Pty Ltd

Slip resistance testing of GRP flooring surfaces for Anglia Composites Ltd

This document is a preview generated by EVS

TEST METHODS. Physico-chemical characteristics Slip resistance 1 Test methods

Web:

Slipping properties of ceramic tiles / Quantification of slip resistance

Test Report to AS/NZS :2015. Report No. T160402_S

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

Slips and falls. OHS Exchange FDF - Willis. better information, fewer accidents. 22 nd September

SIGMADEK, LTD. FIRE TEST REPORT

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

NATIONAL TECHNICAL SYSTEMS

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

PERFORMANCE TEST REPORT. Rendered to: SOLATUBE INTERNATIONAL, INC.

FUNDERMAX GMBH FIRE TEST REPORT

EY

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Tile Tech Warnings. Paving America one step at a time! MANUFACTURER OF DETECTABLE WARNING PAVERS AND TILES

Sustainable Slip Resistance: An Opportunity for Innovation

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller)

Slip resistance according to Goldilocks

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

Multi Line Laser Level Model: L203

Fire resistance test on fire collars protecting a concrete slab penetrated by services

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Are Your Kitchen Hood Filters Compliant?

REASONS FOR SPECIFICATION REASONS FOR SPECIFICATION. Polysafe Ultima - heavy-duty safety flooring with enhanced slip resistance

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

BCTC CARPET TECHNICAL CENTRE

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

TEST REPORT: CHM14-05-CHY

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

Evaluation of Slip Potentials on Bilecik Beige Marble with Pendulum Method

Model pictured: RPA3CI6SS/WH

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Determination of air borne sound insulation According to ISO 140-3

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

SAFEGUARD RANGES SLIP RESISTANT VINYL SHEET SAFEGUARD DESIGN SAFEGUARD R10, R11, R12

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

OPPORTUNITY IS STEADILY GROWING.

Ceiling Mounted Ducted Exhaust Fan Kit

Owner s Manual. Spa Blower ONGA. Installation & operation instructions

HOTEL MOTEL ENGINEER ASSOCIATION

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Window Accessories Whitmatic

Comprehensive Short-Term Radon Survey Report

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

Introduction This presentation describes tests undertaken by Frenger Systems Limited on a water driven radiant heating panel arrangement.

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

Slope stability assessment

Hygiene cleaning equipment Keeping all equipment clean

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Slip Resistant Floor Surfaces

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

ANSI NFSI B101.0 Walkway Auditing Standard. Brent Johnson Traction Auditing LLC

NF X : Parts 1, 2, 3, 4 & 5

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Refrigerant Management Requirements Update

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Checklist For Building Inspection & Fire Safety

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

For more information on Tarkett go to

10 Cambridge Road. Wollaton, Nottingham NG8 1FP.

Ozone Depleting Substances (ODS) Rule Updates

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

The Concept. Features. Benefits

Overhead Line Insulators

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES

Owner Profile. Property Profile. Building Use Classification Permit Date. Building Use Classification Permit Date. Year Built Year Refurb Permit No.

PASSENGER RAIL NETWORK LIGHTING OF STATION ENVIRONMENT TO COMPLY WITH DISABILITY STANDARDS FOR ACCESSIBLE PUBLIC TRANSPORT

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

Transcription:

Registered Testing Authority - CSIRO 26 June 2014 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7086.4s Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 24 June 2014 Manufacturer: Giannino Ceramiche Product Desc.: Basaltina Series - Matt Finish - Charcoal - 300x600mm Sampling details: Where: Delivered Date: 24 June 2014 By whom: Courier How (methods): N/A The results reported relate only to the sample(s) tested and the information received. No responsibility is taken for the accuracy of the sampling unless it is done under our own supervision. CSIRO cannot accept responsibility for deviations in the manufactured quality and performance of the product. While CSIRO takes care in preparing the reports it provides to clients, it does not warrant that the information in this particular report will be free of errors or omissions or that it will be suitable for the client's purposes. CSIRO will not be responsible for the results of any actions taken by the client or any other person on the basis of the information contained in the report or any opinions expressed in it. The reproduction of this test report is only authorised in the form of a complete photographic facsimile. Our written approval is necessary for any partial reproduction. This test report consists of 4 pages SUMMARY OF SLIP RESISTANCE TESTS PERFORMED: Result Class AS 4586:2013 Slip resistance classification of new pedestrian surface materials Appendix A: WET Pendulum (Slider 96): Mean SRV: 50 P4 (W*) AS 4586:2013 Slip resistance classification of new pedestrian surface materials, Appendix D: OIL-WET Ramp Corrected mean overall acceptance angle: 18 R 10 ( *) = AS 4568:2004 classification In order to interpret the classifications, please refer to Standards Australia Handbook 197, An Introductory Guide to the Slip Resistance of Pedestrian Surface Materials, which recommends minimum classifications for a wide variety of locations. It is important to realise that test results obtained on unused factory-fresh samples may not be directly applicable in service, where proprietary surface coatings, contamination, wear and subsequent cleaning all influence the behaviour of the pedestrian surface.

REPORT NO: 7086.4s Page 2 of 4 PRODUCT DESC: Basaltina Series - Matt Finish - Charcoal - 300x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS WET PENDULUM TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix A) Test Date: 30 June 2014 RESULTS: Location: Slip Resistance Laboratory Slider used: 96 Conditioned with grade P400 paper, dry Sample: Unfixed Cleaning: Acetone Temperature: 23 C Pendulum Friction Tester: Stanley (S/N: 9234, calibrated 17/04/2013) Test conducted by: Andy Giang Specimen 1 2 3 4 5 Last 3 swings (BPN) 53 47 52 49 52 52 47 52 49 52 52 47 51 49 52 Averages 52 47 52 49 52 Mean SRV : 50 CLASS : P4 (W*) ( *) = AS 4568:2004 classification Where products are to be used in wet barefoot areas, it is more appropriate to test to Appendix C of AS 4586 (which is technically equivalent to DIN 51097).

REPORT NO: 7086.4s Page 3 of 4 PRODUCT DESC: Basaltina Series - Matt Finish - Charcoal - 300x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS OIL-WET RAMP TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix D) Test Date: 26 June 2014 Location: Slip Resistance Laboratory Test conducted by: KH, AG Sample Fixed Joint width: 0 mm Surface structure: [ ] Smooth [ X ] Profiled [ ] Structured RESULTS Corrected mean overall acceptance angle: 18 Displacement space: not tested CLASSIFICATION: Slip Resistance Assessment Group: R 10 Displacement Space Assessment Group: - Test shoe used: Lupos Picasso

REPORT NO: 7086.4s Page 4 of 4 TILE DESC: Basaltina Series - Matt Finish - Charcoal - 300x600mm Date and Place 26 June 2014, Highett, Vic Name, Title and Digital Signature: ANDY GIANG Technical Officer Tel: 61 3 92526000 Fax: 61 3 92526244 Email: Andy.Giang@csiro.au PR:G010714-14:18:47

Registered Testing Authority - CSIRO 26 June 2014 Our Ref. EN13 / 2337 03/0212 TEST REPORT No. 7086.5s Requested by: Metro Tiles Pty Ltd 192 Granite Street Geebung QLD 4034 on (date): 24 June 2014 Manufacturer: Giannino Ceramiche Product Desc.: Basaltina Series - Natural Finish - Grigio - 600x600mm Sampling details: Where: Delivered Date: 24 June 2014 By whom: Courier How (methods): N/A The results reported relate only to the sample(s) tested and the information received. No responsibility is taken for the accuracy of the sampling unless it is done under our own supervision. CSIRO cannot accept responsibility for deviations in the manufactured quality and performance of the product. While CSIRO takes care in preparing the reports it provides to clients, it does not warrant that the information in this particular report will be free of errors or omissions or that it will be suitable for the client's purposes. CSIRO will not be responsible for the results of any actions taken by the client or any other person on the basis of the information contained in the report or any opinions expressed in it. The reproduction of this test report is only authorised in the form of a complete photographic facsimile. Our written approval is necessary for any partial reproduction. This test report consists of 4 pages SUMMARY OF SLIP RESISTANCE TESTS PERFORMED: Result Class AS 4586:2013 Slip resistance classification of new pedestrian surface materials Appendix A: WET Pendulum (Slider 96): Mean SRV: 36 P3 (X*) AS 4586:2013 Slip resistance classification of new pedestrian surface materials, Appendix D: OIL-WET Ramp Corrected mean overall acceptance angle: 14 R 10 ( *) = AS 4568:2004 classification In order to interpret the classifications, please refer to Standards Australia Handbook 197, An Introductory Guide to the Slip Resistance of Pedestrian Surface Materials, which recommends minimum classifications for a wide variety of locations. It is important to realise that test results obtained on unused factory-fresh samples may not be directly applicable in service, where proprietary surface coatings, contamination, wear and subsequent cleaning all influence the behaviour of the pedestrian surface.

REPORT NO: 7086.5s Page 2 of 4 PRODUCT DESC: Basaltina Series - Natural Finish - Grigio - 600x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS WET PENDULUM TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix A) Test Date: 30 June 2014 RESULTS: Location: Slip Resistance Laboratory Slider used: 96 Conditioned with grade P400 paper, dry Sample: Unfixed Cleaning: Acetone Temperature: 23 C Pendulum Friction Tester: Stanley (S/N: 9234, calibrated 17/04/2013) Test conducted by: Andy Giang Specimen 1 2 3 4 5 Last 3 swings (BPN) 39 37 36 33 37 38 35 37 33 36 38 35 37 32 36 Averages 38 36 37 33 36 Mean SRV : 36 CLASS : P3 (X*) ( *) = AS 4568:2004 classification Where products are to be used in wet barefoot areas, it is more appropriate to test to Appendix C of AS 4586 (which is technically equivalent to DIN 51097).

REPORT NO: 7086.5s Page 3 of 4 PRODUCT DESC: Basaltina Series - Natural Finish - Grigio - 600x600mm SLIP RESISTANCE CLASSIFICATION OF NEW PEDESTRIAN SURFACE MATERIALS OIL-WET RAMP TEST METHOD TEST CARRIED OUT IN ACCORDANCE WITH AS 4586:2013 (Appendix D) Test Date: 26 June 2014 Location: Slip Resistance Laboratory Test conducted by: KH, AG Sample Fixed Joint width: 0 mm Surface structure: [ ] Smooth [ X ] Profiled [ ] Structured RESULTS Corrected mean overall acceptance angle: 14 Displacement space: not tested CLASSIFICATION: Slip Resistance Assessment Group: R 10 Displacement Space Assessment Group: - Test shoe used: Lupos Picasso

REPORT NO: 7086.5s Page 4 of 4 TILE DESC: Basaltina Series - Natural Finish - Grigio - 600x600mm Date and Place 26 June 2014, Highett, Vic Name, Title and Digital Signature: ANDY GIANG Technical Officer Tel: 61 3 92526000 Fax: 61 3 92526244 Email: Andy.Giang@csiro.au PR:G010714-14:23:40