Hospital ventilation & infection prevention

Similar documents
Ventilation in Healthcare Facilities Peter Hoffman, Public Health England A Webber Training Teleclass

Biological Safety Cabinets. Biological Safety Cabinets

Professional Air Decontamination

Create Clean Air. The specialists in Indoor Air Quality

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Theatre Classification and Air Particle Count Is that Surveillance?

PDHengineer.com. Course HV HVAC Design for Hospitals & Healthcare Facilities

PRESSURE RELATIONSHIPS IN HOSPITAL CRITICAL-CARE FACILITIES

ประธานกรรมการว ชาการฯสมาคมปร บอากาศแห งประเทศไทย

Ventilation for Healthcare Facilities

Ventilation for Healthcare Facilities. Topics to be Covered

Supplement 3: Engineering Controls

How to comply with CDC Guidelines

Moisture Management And Mold Remediation Protocols for Healthcare Facilities

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

The Role of Air Handling Units in Combating the Spread of Infectious Disease

Housekeeping and Laundry Ulrika Ransjö

Variable Air Volume with Indoor Air Quality

Part B - Health Facility Briefing and Planning. PLANNING Operational Models Functional Areas Functional Relationships

Investigation of the Performance of the Air Purifier in High-Risk Hospital Rooms by Counting Particles

Breathe Easy with Sharp Plasmacluster Air Purifiers

Precision Ultrasonic Cleaning Equipment Buyers Guide

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

VP, Facilities and Construction Management

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

36.0 Sterile Supply Unit (SSU)

CBC s Inspection Findings and Possible Remedies Thereto

DHS Design guidelines for hospitals and day procedure centres. Part E- Building Services and Environmental Design

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Interim Life Safety Assessments and Infection Prevention Assessments

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Infection Control Manual. Table of Contents

Biological Safety Cabinets or Fume Hoods Which one to use?

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Humidity Control Combats Healthcare Associated Infection

Air-Conditioning for the Environment of Care

Breathe Easy with Sharp Plasmacluster Air Purifiers

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

healthy comfort Indoor Air Quality Solutions

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

Welcome to the IQAir revolution.

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

How to Use Water Safely in Acute Health Care Sites During a Boil Water Advisory

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Introducing the most technically advanced indoor air treatment system

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

Fume Hood Safety TYPES OF FUME HOODS

Next Generation GENANO Technology

LIMITED PRODUCT WARRANTY

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

PART III. Laboratory equipment

Perfect Air Purifiers

Please read this manual carefully before use to ensure proper usage and save

Owners Manual Model: XXL

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

CLEAN AIR SYSTEM.

UVC in the Operating Room.

healthy comfort Indoor Air Quality Solutions

AF2 PROFESSIONAL LINE. Washer disinfector for human waste containers. Your Health, our Technology

EcoCooler Legionella Risk Assessment Information Pack

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

Dealing with water shortages

CORRECT ENDOSCOPE REPROCESSING

Pharmawiki.in. Principle of HOT AIR OVEN (Dry heat sterilization)

Safe Operating Procedure (Revised 2/10)

MECHANICAL VENTILATION

Cleaning and Disinfecting Bathrooms. Public Health Reasons

Iso Solutions. Enabling wellbeing

Control of Biological Hazards

Summary of accomplishments

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

The problem with other hand dryers

Mediclean Complanate Ultra Clean Ventilation

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Ultraclean ventilation. The shape of canopies to come.

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Quick Reference Guide to Cabinet types

(12) United States Patent (10) Patent No.: US 7, B2

Getinge 600 series Top-loaded flusher-disinfectors

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

ensuring environmental integrity

Section 2. Product overview & label familiarisation

Indoor Air Quality Test Report

Celebrate Your Freedom from Allergens & Particulate Pollution

CONSIDERATIONS ON FACILITY AND ENGINEERING CONTROLS IN THE WAKE OF USP <800>

at the touch of a button.

A whole lot of fresh.

Class II Biosafety Cabinets

HVAC Efficiency In Healthcare. Presenter Mr. Nate Lincoln

Australasian Health Facility Guidelines. Part D - Infection Prevention and Control D Physical Environment

GUIDELINES FOR MOLD REMEDIATION (REMOVAL)

Appendix A.4.1. Safe Fume Hood User Guide

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

CLINI SAFE. The safest choice for Health Care Establishments NEW PRODUCT FEATURES. 5 Cleaning methods. Fire reaction: A1

Transcription:

Hospital ventilation & infection prevention Peter Hoffman Consultant Clinical Scientist Antimicrobial Resistance and Healthcare Infections Reference Unit

In the beginning The importance of ingress of contaminated air from clinical areas into theatres: Shooter RA et al. Postoperative wound infection. Surg Gynec Obstet 1956; 103: 257-62. Powerful extracts in the theatre (to get rid of steam from boiling water sterilisers ). Contaminated air was being drawn into a theatre from adjacent clinical areas. When this inward flow was reversed This was followed by an immediate reduction in the bacteria in the air and by a striking fall in the incidence of wound infections from 37 out of 427 clean operations to 5 out of 532. There are other, similar papers from that era.

But it s not just air from outside theatres that s contaminated Skin cells are constantly being shed. They are small (5 15 micron) particles, some of which will carry microcolonies (1 1,000 cells) of those bacteria that live on that person s skin. The more people in a space and the more they move, the greater the concentration of these contaminated skin scales ( squames ).

1,000 litres of air in an empty room

1,000 litres of air person walking by sampler

Contamination from the air supply? Outdoor air is usually reasonably clean, but unreliably so. Air to operating theatres is filtered to remove most contamination. The air supplied is low contamination (HEPA filters not required) - not sterile; it is the most minor of the contamination sources.

Infection prevention & theatre ventilation 1 Preventing ingress of airborne contamination via the supplied air Filtration 2 Excluding ingress of airborne contamination from surrounding areas Controlling airflow direction between rooms 3 Diluting airborne contamination generated in the theatre and preparation room High air supply rates All this is to stop airborne contamination from settling out in the wound

Pathways into the wound Probably the majority of airborne bacteria that end-up in a surgical wound, do so via exposed instruments.

Theatre suite ventilation

Ventilation of operating theatres For infection control, validation (commissioning) should show: Correct air supply engineering, correct filters in place, air cannot bypass filtration (visual inspection of filters) Turbulent airflow in theatre with no stagnant areas Correct ventilation rates: 25 air changes per hour in theatre and prep i.e. air of 25 time the volume of the room supplied every hour Correct airflow between rooms: robust airflow in the right direction, precise pressure is less important

Settle plates for theatre sampling? Settle plates sample microbes settling out from a theoretical cylinder of air above the plate. Large heavy particles will settle-out quickly sampled at high efficiency Small light particles will settle-out slowly sampled at low efficiency The relationship to actual microbial numbers in the air will depend on the size distribution of those particles. There are no pass/fail criteria for settle plates used in theatres There can be local traditions of using settle plates; their interpretation is subjective.

Airborne isolation There are a minority of infections where transmission can be by very small airborne particles These particles are so light that they behave much as the gas in which they are suspended they are effectively solutions in the air: aerosols Examples of infections where transmission via the air plays a significant role: TB particularly smear positive or MDR + any TB in the context of immuncompromised patients. Varicella-zoster, measles Viral haemorrhagic fevers?? (probably not)

Airborne isolation Isolation of these patients should achieve: Dilution of infectious particles in the room for the safety of staff and visitors in the room (in addition to respiratory protection) Prevent transfer of contaminated air to nearby rooms Safe exhaust of air to outside All these should be achieved in a negative pressure room

Negative pressure room A room from which much more air is extracted than supplied. This produces: High dilution in the room air for the safety of staff and visitors in the room Air passes into the room from adjacent rooms to make-up for the loss of air this means that the room leaks inwards and does not pass out to adjacent rooms Air should be exhausted outside away from air intakes, windows or people it will be safely exhausted to infinite dilution The room cannot have opening windows these would negate any air control scheme. The door must be kept closed The room should have its own toilet and shower An anteroom is useful.

How to achieve negative pressure? Mechanical ventilation expensive but good. Extract fan in wall or window cheap but noisy (need patient s cooperation for successful isolation), controls can be wrongly adjusted (to intake rather than extract) or switched off when should be on. Whirly bird (wind-driven extracts) will vary according to windspeed & need regular mechanical maintenance. Useful as backup rather than primary means to achieve negative pressure

How much negative pressure? It does not matter, as long as smoke shows good flow from outside to inside.

Air change rate The greater the air change rate, the faster the dilution of airborne infectious particles for the safety of staff and visitors in the room. In patient isolation rooms, there should be at least 6 air changes per hour, preferably around 12. More than this and the patient may not be comfortable. If the patient is uncomfortable, they may not cooperate with their isolation. In procedure rooms, such as bronchoscopy, there can be much higher air change rates.

Air change rates and dilution One air change removes 63% of airborne contamination (assuming good mixing). The timing of this process starts when the patient leaves the room (when dispersion stops). If a bronchoscopy room has 30 air changes per hour, this means one air change every 2 minutes, 5 air changes (>99% removal) in 10 minutes

Protective isolation The majority of susceptible patients can be protected from infection by procedures handwashing, equipment decontamination etc. A very small minority of highly neutropenic patients (mainly bone marrow transplant) need protection against breathing-in fungal spores these originate from outside the hospital

Protective isolation the positive pressure room Air is supplied to rooms via high efficiency particulate air (HEPA) filters. More air is supplied than extracted, so clean air leaks out of their rooms preventing ingress of unfiltered air. The rate of air supply is irrelevant it is not trying to dilute anything inside the room. It cannot have opening windows The door must be kept closed; a lobby is useful. It must have its own toilet/shower Positive pressure ventilation without HEPA filtration is irrelevant.

This is not ventilation This takes in air, cools it and returns it to the same room. The air does pass through internal filters, but these are not fine enough to remove microbes. This is a good way of cooling rooms but does nothing about controlling the level of microbial contamination or the airflow between rooms.