AXPR Wall Mounted Axial Panel Fans

Similar documents
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

MPA Modular Plenum Array Installation, Operation, and Maintenance Manual

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

Torit Radial Blade Fan TRB-1 to 10 (60 and 50 Cycle)

Installation, Operation and Maintenance Manual

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

Panel Fan Series Operators Manual (Galvanized and Polymer)

Enviro KES INSTALLATON MANUAL

INLET DAMPER WALL FAN UNIT

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Installation, Operation and Maintenance Manual

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Panel Fan Series Operators Manual (Galvanized and Polymer)

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

57" Fiberglass Exhaust Fan with Cone

Marley Ultra Quiet Fan

Installation, Operation and Maintenance Manual

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

User Manual Box Exhaust Fan Series (Belt Drive)

Installation Instructions Part No , Part No Part No

HMD Heated Makeup Direct: A Direct Fire Make-Up Air Unit INSTALLATION, OPERATION AND MAINTENANCE MANUAL

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

SuperKlean Washdown Products

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation, Safety, Operation & Maintenance Instructions And Parts List For Model CVS, Belt Drive Propeller Fans Arrangement 9

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

for MODEL KSU MAKE-UP AIR UNITS

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

GRIND PRO DUAL OR DISC SANDER. Operator Manual

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Installation, Safety, Operation & Maintenance Instructions And Parts List

INSTALLATION, OPERATION & MAINTENANCE MANUAL

OWNERS GUIDE TO INSTALLATION AND OPERATION

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

FAN ENGINEERING. Fan Installation, Operation & Maintenance

HB CDA SERIES WITH TEMPERATURE SETBACK

GLEB Kitchen exhaust fan

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

AZN ATEX INSTALLATION AND MAINTENANCE

FAN ENGINEERING. Fan Installation, Operation & Maintenance

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

ACN SMOKE INSTALLATION AND MAINTENANCE

SECTION (15833) - HVAC POWER VENTILATORS

Installation, Safety, Operation & Maintenance Instructions And Parts List For Model PF, Direct Drive Propeller Fans Arrangement 4

WARNING FIRE OR EXPLOSION HAZARD.

Aquatower User Manual

WARNING FIRE OR EXPLOSION HAZARD.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

568X, 587X, 588X Series

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

OPERATION AND MONTAGE MANUAL ROOF FANS

LC Series - Light Commercial Pump Station Installation and Operation Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

ACT Cartridge Dust Collector

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

OPERATION AND MONTAGE MANUAL ROOF FANS

Installation, Operation and Maintenance Manual

15-Year Limited Warranty

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS


Centrifugal Fans maintenance manual

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

ELECTRIC UNIT HEATER REGULAR DUTY

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

HEATING AND AIR CONDITIONING

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

Shredder FD 8906CC Cross-Cut

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Transcription:

Bulletin 78-January-03-06 AXPR Wall Mounted Axial Panel Fans INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for the AXPR wall mounted axial panel fans. M.K. Plastics catalogs and reference material on the above system, provides additional information describing the equipment, performance, available accessories, and specifications. For additional safety information, refer to AMCA publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans. For Information on special application requirements, contact M.K. Plastic s corporate office at (514) 871-9999. Fig. 1 AXPR Propeller Fan Receiving and Inspection Carefully inspect the venturi/blower and accessories for any damage and shortage immediately upon receipt of the fan. Turn the propeller by hand to ensure it turns freely and does not bind. If shutters are provided, check for free operation of all moving parts. Record on the Delivery Receipt any visible sign of damage. WARNING The AXPR has rotating parts. Safety precautions should be exercised at all times during installation, operation, and maintenance. ALWAYS disconnect power prior to working on fan. 1

Handling and Storage Fans should be lifted by the panel mounting flanges. Never by the propeller, motor, motor bracket, fan inlet, shutter frame, or any other part not designed for lifting. If the fan is stored for any length of time prior to installation, the fan and accessories should be stored in a dry, clean location. If outdoor storage is necessary, protection should be provided. The fan should be covered to prevent the accumulation of dirt and moisture. Cover motors with waterproof material. Check shutters for free operation and lubricate moving parts prior to storage. Inspect the stored unit periodically. Rotate the propeller by hand every two weeks. Personal Safety Disconnect switches are recommended. Place the disconnect switch near the fan in order that the power can be swiftly cut off in case of an emergency, and in order that maintenance personnel are provided complete control of the power source. Installation Cut out wall opening of sufficient size so that, when framed in, the finished opening will accept the fan and wall box assembly, (refer to MK Plastics submittal for specific outside dimensions of the wall box). It is preferable to frame in the opening with 2 x 6 material, or other similar suitable material or metal channels adequate to support the fan as shown in Figure 2. Slide the fan and wall box assembly into the framed opening in the wall. Attach the fan by inserting a suitable fastener through each of the pre-punched mounting holes in the fan panel mounting flange. Care should be taken not to bend or distort the fan panel or other components during installation. A distance of at least one and onehalf times the diameter of the fan should be allowed between the fan inlet or discharge opening and any adjacent wall or large obstruction. If a weather cowl is supplied on a supply fan, position the cowl over the opening on the exterior side of the wall, and attach by inserting suitable fastener through each pre-punched mounting hole of the cowl mounting flange. Fig. 2 Wall Installation 2

Wiring Installation All wiring should be in accordance with local ordinances and the National Electrical Code, NFPA 70. Ensure the power supply (voltage, frequency, and current carrying capacity of wires) are in accordance with the motor nameplate. Lock off all power sources before unit is wired to power source. Due to the mounting location of AXPR fans, it is sometimes difficult to reach disconnect switches if mounted to the unit. It is therefore recommended to remotely mount the switch for easier access. Personal Safety Disconnect switches are recommended. Place the disconnect switch near the fan in order that the power can be swiftly cut off in case of an emergency, and in order that maintenance personnel are provided complete control of the power source. Follow the wiring diagram in the disconnect switch and the wiring diagram provided with the motor. Correctly label the circuit on the main power box and always identify a closed switch to promote safety (i.e. red tape over a closed switch). Wiring Diagrams Single Speed, Single Phase Motor 3 Phase, 9 Lead Motor When ground is required, attach to ground A or B with No. 6 thread forming screw. To reverse, interchange T-1 and T-4 leads. To reverse, interchange any 2 line leads. 2 Speed, 2 Winding, Single Phase Motor 2 Speed, 1 Winding, 3 Phase Motor When ground is required, attach to ground A or B with No. 6 thread forming screw. To reverse, interchange T-1 and T-4 leads. To reverse, interchange any 2 line leads. Motors require magnetic control. Single Speed, Single Phase, Dual Voltage 2 Speed, 2 Winding, 3 Phase When ground is required, attach to ground A or B with No. 6 thread forming screw. To reverse, interchange T-5 and J-10 leads. To reverse: High speed-interchange leads T11 & T12. Low speed-interchange leads T1 & T2. Both speeds-interchange any 2 line leads. 3

Final Installation Steps 1. Inspect fasteners and setscrews, particularly fan mounting fasteners, and tighten according to the recommended torque shown in the table Recommended Torque for Setscrews/Bolts. 2. Inspect for correct voltage with voltmeter. Make sure the supply voltage is correct. 3. Ensure all accessories are installed. 4. The propeller should rotate freely and not rub on the inside of the fan inlet cone. Turn the propeller by hand to check for binding. 5. Test the fan by bumping the starter to be sure the propeller rotation is the same as indicated by the arrow affixed to the unit, marked Rotation. Do not allow the fan to run in the wrong direction. This will overheat the motor and cause serious damage. For 3-phase motors, if the fan is running in the wrong direction, check the control switch. It is possible to interchange two leads at this location so that the fan is operating in the correct direction. Operation Pre-Start Checks 1. Lock out all the primary and secondary power sources. 2. Ensure fasteners and setscrews, particularly those used for mounting the fan, are tightened. 3. Inspect motor wiring. 4. Ensure fan, screens and shutter are clean and free of debris. Any loose items or debris could be drawn into the fan, or be dislodged by the fan discharge. 5. Inspect propeller-to-inlet clearance. 6. Restore power to the fan. Start Up Turn the fan on. In variable speed units, set the fan to its lowest speed and inspect for the following: 1. Direction of rotation. 2. Excessive vibration. 3. Unusual fan noise. 4. Excessive and unusual motor noise. 5. Improper motor amperage or voltage. If a problem is discovered, immediately shut the fan off. Lock out all electrical power and check for the cause of the trouble. See Troubleshooting. Setscrews should be rechecked after a few minutes, eight hours and two weeks of operation (see the following table for correct tightening torques). Recommended Torque for Setscrews/Bolts (IN/LB.) Size Setscrews Recommended Torque Key Hex Inch-Lbs Across Flats Min. Max. Size Hold Down Bolts Wrench Torque (inch-lbs) No. 10 3/32 28 33 3/8-16 240 1/4 1/8 66 80 1/2-13 600 5/16 5/32 126 156 5/8-11 1200 3/8 3/16 228 275 3/4-10 2100 7/16 7/32 348 384 7/8-9 2040 1/2 1/4 504 600 1-8 3000 5/8 5/16 1104 1200 1-1/8-7 4200 3/4 3/8 1440 1800 1-1/4-7 6000 4

Inspection Inspection of the fan should be conducted in the first 30 minutes, 8 hour and 24 hour intervals of satisfactory operation. Inspect bolts, setscrews, and motor mounting bolts. Adjust and tighten as necessary. Also check for unusual or excessive noise and vibration. Maintenance M.K. Plastics AXPR fans are manufactured to high standards with quality materials and components. Proper maintenance will ensure a long and trouble-free service life. Do not attempt any maintenance on a fan unless the electrical supply has been completely disconnected and locked. In many cases, a fan can windmill despite removal of all electrical power. The rotating assembly should be blocked securely before attempting maintenance of any kind. The key to good fan maintenance is regular and systematic inspection of all fan parts. Inspection frequency is determined by the severity of the application and local conditions. Strict adherence to an inspection schedule is essential. Establish a schedule for inspecting all parts of the fan. Inspect fans exhausting corrosive or contaminated air within the first month of operation. Fans exhausting contaminated air (airborne particles) should be inspected every three months, or sooner. Regular inspections are recommended for fans exhausting non-contaminated air. It is recommended the following inspection be conducted twice per year. Inspect bolts and setscrews for tightness. Tighten as necessary. Worn setscrews should be replaced immediately. Inspect for cleanliness. Clean exterior surfaces only. Removing dust and grease on motor housing assures proper motor cooling. Removing dirt from the propeller and housing prevents imbalance and damage. Propeller Balance Airstreams containing particulate or chemicals can cause abrasion or corrosion of fan parts. This wear is often uneven and can lead to significant propeller imbalance over time. When such wear is discovered, a decision must be made to rebalance or replace the propeller. Specialized equipment can be used to rebalance a cleaned propeller that is considered structurally sound. Balance weights should be rigidly attached at a point that will not interfere with other fan components nor disrupt airflow. Motor Bearings Fractional horsepower motors installed on the smaller fans are generally lubricated for life and require no further attention. Motors equipped with oil holes should be oiled in accordance with the manufacturer's instructions printed on the motor. Use a high grade SAE 20 machine oil and use caution not to over lubricate. Motors supplied with grease fittings should be greased according to directions printed on the motor. It is advisable to have your maintenance department remove and disassemble the motor, and lubricate the bearings after 3 years of operation in excessive heat and or in a contaminated air stream consisting of airborne particles. Motor Service Should the motor prove defective within one-year period, contact M.K. Plastics directly, or your nearest motor service representative. Troubleshooting Problem and Potential Cause Low Capacity or Pressure Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the motor or drive belt assembly. Poor fan inlet conditions. There should be no obstructions at the inlet. Improper wheel alignment. Excessive Vibration and Noise Damaged or unbalanced propeller. Speed too high. Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the motor. Motor bearings need lubrication or motor may need replacement. Fan surge. Overheated Motor Motor improperly wired. Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the motor. Cooling air diverted or blocked. Improper inlet clearance. Incorrect fan RPM. Incorrect voltage. 5

Replacement Parts List It is recommended that only factory-supplied parts be used. M.K. Plastics parts are built to be fully compatible with the original fan, using specific materials and tolerances. These parts carry a standard M.K. Plastics warranty. A spare parts list can be obtained directly from your technical sales representative, or M.K. Plastics directly. When ordering replacement parts, specify the AXPR fan size, part name, M.K. Plastics part number, and bore size if related to the propeller. Some of this information is on a nameplate attached to the fan. For assistance in selecting replacement parts, please contact your local M.K. Plastics representative. Suggested replacement parts Propeller Shutter Motor Wall box Safety screens Motor support Fig. 3 Exhaust Fan Fig. 4 Supply Fan Tel: (514) 871-9999 Fax: (514) 871-1753 Email: mkfans@mkplastics.com www.mkplastics.com 6