EARTH FAULT METER MD-08

Similar documents
ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

1.7. Insulation fault evaluators EDS460/490 EDS461/491

02/11/2015

Fire Control Panel FS5100

Process Alarm Module RTA 421

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Rules for Intruder Alarm Systems

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

02/11/2015

Insulation fault evaluator EDS460-DG

For more than 35 years METOR metal detectors have been leading the way in the industry. Once again, METOR is setting new standards in metal detection.

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Parameterisable compact fault annunciator with permanent display

QUICK USER GUIDE. Alarm Control Panel

Multi-Gas-Controller MGC2

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Constant voltage charger. Type UP 610. »We store the world's energy« Network

Audible warning devices for external alarm

FEC403EN Installation Manual

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

M1000 Alarm Annunciator

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

UV - Monitor UVT 16. Use. Description

SENTINEL A - Fault Passage Indicator

M15051) INSTRUCTION MANUAL

IR5002. Operating Manual. Insulation monitoring device for IT DC systems V ISO Quality System Certified

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

CSP-204 CSP-208 CSP-104 CSP-108

BENDER A-ISOMETER IRDH265 IRDH365

DTA04. Motor thermistor relay. Benefits. Description

Fire Control Panel FS4000

SENTINEL D - Fault Passage Monitoring

Engineering Guideline. pac- Carriers Type Universal

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Operating Manual UV Monitor UVT 18

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Two-Channel Gas Controller

Gas cylinder scale Model GCS-1

IT system floor-standing distribution

Room Temperature Sensors

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

BC3250. Blowdown Controller

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

I/A Series 716C 1/16 DIN Temperature Controller

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

DES - DYNAMIC ESCAPE SYSTEM TUNNEL EMERGENCY LIGHTING VER.17.1

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Operating Manual MS220KA and MSR220KA

VAMP 120 & 121. Arc flash detection units. Product picture

ESP TECHNOLOGIES LIMITED

Spectron LSN (Life Safety Network) Suggested Specifications

PolyGard 2-channel Gas Controller MGC-03

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Universal fault annunciator for panel mounting

Remote alarm indicator and test combination MK2430

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

NEO XL NEO XL NEO XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Product Data Sheet. Remote Terminals. Features:

Loadstar AC/DC Systems

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

DTA. Motor thermistor relay. Benefits. Description

TEMPERATURE CONTROLLER

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Transcription:

EARTH FAULT METER MD-08 MEASUREMENT AND MONITORING DEVICES AC & DC POWER SOLUTIONS TRACTION CONVERTERS

APPLICATION The MD-08 is designed to measure continuous insulation resistance in the circuits of DC systems. When the value of the resistance falls below a set value, an alarm relay is triggered. The device may be used in 220 V=, 110 V=, 48 V= and 24 V= systems. The system detects drops in both asymmetric resistance (only the positive or negative pole relative to earth or a 220 V / 380 V supply) and symmetric resistance (simultaneous fall in resistance of both poles). In addition, the potentials at both poles of the battery are measured, and alarm thresholds can be set for the minimum and maximum permitted battery voltage. MAIN FEATURES simple to use stable parameters easy to install compact dimensions low cost to install and operate high immunity to interference low value of measurement signal (5 V) wide range of resistance measurement wide range of alarm settings levels can be used in 220 V=, 110 V=, 48 V= and 24 V= systems measurement of + and potential relative to PE STANDARDS AND CERTIFICATES The device complies with the following standards: EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use. General requirements. Earth fault meter MD-08 EN 61326 EMC. Electrical equipment for measurement, control and laboratory use. Certificate: Energopomiar-Elektryka no. 16/EA/97 AC & DC POWER SOLUTIONS TRACTION CONVERTERS

PRINCIPLES OF OPERATION An electronic system containing a single-chip microprocessor performs constant measurement of the earth resistance using an AC signal (0.05 Hz). When the value of the resistance falls below a minimum value, set using the keypad and LCD display, an alarm relay is triggered and the appropriate LEDs (for circuits with + and polarization) indicate the alarm condition. The values for the potentials of the + and circuits relative to the PE circuit, as well as the measured resistance reading and the set alarm level, are displayed constantly while the device is in use. The use of a low-frequency measurement signal and appropriate filtering of signals mean that the device is highly resistant to the effects of interference and the AC component of the voltage. The device detects falling in resistance relative to earth and relative to a 220 V / 380 V supply. The use of highly stable components and digital conversion of signals guarantees that the parameters will not vary with temperature or over the time. KEYPAD LCD/LED MD 08 µp ALARM 220 V 50 Hz R Earth fault meter - functional diagram EARTH FAULT METER MD-08

INSTALLATION There are three lines of terminals on the lower part of the cabinet. The device should be connected as follows: ALARM MD-08 terminals 7, 8, 9 alarm circuit terminals 11, 15 220 V (50 Hz) power supply terminal 18 PE circuit terminals 19, 27 battery poles 789 11 15 18 19 27 L1 N PE power supply measured circuit INCREMENT U-=118 U+=118 V R > 200 Ra= 50 k LCD display MODE OF OPERATION ENTER DECREMENT OPERATION When the device has been properly installed, the alarm levels for resistance and potential should be set. To make these settings: Press ENTER Use the cursors to enter the device code (confirm by pressing ENTER) Use the cursors to enter the settings (pressing ENTER to confirm) When an alarm occurs, the message SYSTEM ALARM is displayed. The type of alarm(s) can be identified using the cursors. Periodically (e.g. once a year) the device should be tested by connecting a suitable resistor in such a way as to cause the resistance (between the pole and the earth) to fall below the alarm level set. On the front of the cabinet are signal LEDs, an alphanumeric LCD display and a keypad. The display shows potential and resistance values: U voltage difference between the circuit and the PE circuit U+ voltage difference between the + circuit and the PE circuit Rs resistance between the DC system and the PE circuit Ra alarm level set The LEDs indicate the following: SUPPLY shows that the device is connected to the power supply ALARM indicates that the insulation resistance has fallen below the alarm level EARTHING+ earthing of + circuit EARTHING earthing of circuit

TECHNICAL PARAMETERS Power supply Input voltage 220 V +15 % 15 % ( 25 %) Frequency 50 Hz Dielectric test 2.8 kv 60 s Measurement circuit Voltage rating of battery 220 V= (110 V=) 48 V= (24 V=) Battery voltage range +15% 25% Measurement range for potential of + and relative to PE 0 250 V 0 99.9 V Symmetric resistance measurement range 1 500 kω Resistance measurement error 10% (±2 poz.) Range of available alarm level settings 5 500 kω Internal resistance ca. 0.5 MΩ Max. capacity of measured circuit 25 µf (50 µf for R<50 kω) Resistance measurement time ca. 5 min Potential measurement time ca. 5 s ca. 30 s Alarm terminals Max. operating voltage 300 V= or 250 V~ Max. load capacity of terminals 220 V~ 4 A 220 V= 0,3 A Ambient conditions (storage and operating) Operating temperature 0 40 C Storage temperature 40 65 C Humidity (noncondensing) max. 98% Installation site altitude below 2000 m Cabinet Degree of protection IP20 Material Self-extinguishing material NORYL UL 94 V-O Mounting DIN rail mounting Dimensions (width depth height) 158 mm 73 mm 90 mm MECHANICAL PARAMETERS 158 mm 73 mm 90 mm To be mounted on a DIN rail using snap fasteners

AC & DC POWER SOLUTIONS TRACTION CONVERTERS MEDCOM Sp. z o.o. Founded in 1988, active in the design, manufacture, installation and servicing of modern electronic devices, aimed mainly at the power industry, military, railway and tramway transport, industry and health service customers. The use of latest technologies and system solutions, the services of highly experienced structural designers and the introduction of an ISO 9001:2000 Quality Assurance System, ensure that the devices manufactured are stateof-the-art and highly reliable. The technical design for all products is carried out in-house. In 2001 the company was awarded a prize The Polish President's Economy Award for THE BEST POLISH SMALL ENTERPRISE. The most important products in the company's offer: DC power supplies Uninterruptible power systems High-voltage power supplies Power supplies (MIL standards) Static converters for railway and tramway applications Power supplies for industrial applications Power active filters Traction battery chargers Static transfer switches Fail-safe power supplies Motor driving systems: AC and DC motors Measurement devices: battery earth fault meters, battery operation monitors Wind power converters MEDCOM Sp. z o.o. 28/30, Barska Street tel. +4822 668 99 34, 668 69 84, 822 88 58 02-315 Warsaw, Poland fax +4822 668 99 29 e-mail: info@medcom.com.pl www.medcom.com.pl Since we are constantly incorporating the latest technological advances, our products are subject to modification. For this reason it may happen that certain elements of the above descriptions are no longer valid. MD-08 03/03 EN