NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING. Photoluminescent Low Level Wayguidance Systems - Overview

Similar documents
PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

Low Location Lighting

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

Photoluminescent emergency pathway marking systems bring a new level of safety to manufacturing environments.

Graphic Products,

Element C3.5 Means of Escape

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

24 Hour Permanent Step Edge Contrasting and Photoluminescent Path Marking Systems

Designers Handbook for High Smoke Risk Areas

JESSUP JESSUP. GLO BRITE EXIT AND EGRESS Photoluminescent signs and tapes. Adhesive Coated Films. Adhesive Coated Films. Jessup Manufacturing Company

EXIT Sign model number C with optional directional chevrons.

Technical Datasheets. Everlux UL 924 Listed RUNNING MAN Sign C Product. 2. Product Description. 3. Quality and Certification

Compliance Guide 2015 NFPA 101 LIFE SAFETY CODE EXIT STAIR PATH MARKINGS. for Ecoglo Photoluminescent Markings to meet the requirements of

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

Emergency Lighting Design

Technical reference Reference & design

Report of Materials and Equipment Acceptance Division

THE TRUE FIRE SURVIVAL CABLE

SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS

Successful Installation. of PHOTOLUMINESCENT EXIT PATH MARKING SYSTEMS

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

Literature Review on Photoluminescent Material Used as a Safety Wayguidance System

A Guide To BS Understanding the selection, spacing & siting of detectors

Hospitals and senior living facilities can be treacherous places in the event of a fire or smoke emergency.

Folknoll Group Ltd. DISABLED REFUGE EVC BS :2011COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE

Products. Building Products Catalogue. VisibleInnovation.com

Fire safety and high rise student accommodation

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Emergency Lighting User's Guide

Design of Fire safety in Multi Occupancy Residential Accommodation

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Fire Management Guide

Life Safety - Means of Egress/Exits NFPA 101

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

RESOLUTION A.752(18) adopted on 4 November 1993 GUIDELINES FOR THE EVALUATION, TESTING AND APPLICATION OF LOW-LOCATION LIGHTING ON PASSENGER SHIPS

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

22 BISHOPSGATE Lift Evacuation Strategy

Fire Safety Policy Date: 0

Supplemental Evacuation Products

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Photoluminescent maritime safety signs

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

FIRE SAFETY RISK ASSESSMENT

Design Guidelines Fire Safety in New and Refurbished Buildings

technical specification smoke venting systems

General Principles of Smoke Control

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Fire Safety Signs. Product code: Product code: Product code: Product code: Product code: Product code: Product code: Product code:

Policy for Safe Evacuation of Persons with Disabilities

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

- CONSTRUCTION FIRE SAFETY STANDARDS

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

ESSEX POLICE, FIRE AND CRIME COMMISSIONER FIRE & RESCUE AUTHORITY Essex County Fire & Rescue Service

New Fire Safety Order

Handout Notes Major changes in BS : 2016

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

- CONSTRUCTION FIRE SAFETY STANDARDS

SELF PRESERVATION SOCIETY By Jim Creak

PREMISES FIRE SAFETY HANDBOOK

EMERGENCY EVACUATION PLAN

Fire Risk Assessment Guidance

Lakanal House inquest: Statement from the Fire Sector Federation

Fire Safety Log Book. Safety through knowledge East Coast Safety Training. Kevin James (Proprietor) 99 Johnson Estate Wheatley Hill Durham DH6 3LH

Dear Customer. Section Old F8 February 2014 Amendments to F8. Replace with new title page and document history pages 1 2B

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Ecoglo Photoluminescent Markings

NCDOI OSFM Evaluation Services

Enclosure 4- RISK ASSESSMENT

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

Underground fires in metro systems failures, accidents and terrorism

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

FIRE SAFETY RISK ASSESSMENT

Kensington Aldridge Academy, London W10

Fire precautions in dwellings

SCOUT HALL INSPECTION CHECKLIST

Hospitality. Emergency Lighting

EMERGENCY LIGHT SERIES

Use this guide to assist you when completing the Evacuation scheme application form.

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

PREMISES FIRE SAFETY LOGBOOK

ONYX EXITPOINT TM THE SOUND OF SAFETY

Q) What should I do if the fire alarm sounds in the building? Q) What do I do if I discover a fire?

INITIAL FIRE SAFETY ASSESSMENT

Barnsley Accredited Landlord Scheme Accredited Property Registration Form

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Egress Marking Solutions. LiteGuide and Beacon Leading the Way to Safety CECO CORBIN RUSSWIN CURRIES SARGENT YALE

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

FIRE RISK ASSESSMENT

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

FIRE SAFETY LOG BOOK

Evacuation Policy for People with Special Needs

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005

Transcription:

NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING Photoluminescent Low Level Wayguidance Systems - Overview Euro Compliance Limited May 2013

AGENDA What is a Photoluminescent Low Level Wayguidance System (PLLWGS)? Why do you not see photoluminescent wayguidance systems the UK? What the Law says Why fit a photoluminescent wayguidance system? Recent developments in low level guidance Frequently asked questions Typical costs Examples Summary and questions

What is a Photoluminescent Low Level Way Guidance System (PLLWGS)? Today PLLWGS are made mainly from a naturally mined, non radioactive, mineral, strontium aluminate. PL minerals contain pigments that have the capacity to store energy from normal light and will emit this energy as a yellow-green glow in darkness. Over time, PL material will diminish in brightness but will remain visible to the dark-adapted eye for up to 6 days. (0.32mcd) PLLWGS aid evacuation by orientating, guiding and directing people to safe locations in the event of an emergency (such as a fire). The system provides guidance information during evacuation of a building or other enclosed space, especially during a blackout, power failure or in smoke or fire. Uses include markings such as exit signs, directional signage, door markings, stair tread and hand rail markings, path markings (wall or floor), door and floor number markings, obstruction identification and other components that compose safety markings. The system can be in the form of paint, plastic UPVC (tape or rigid) or aluminium.

Why do you not see photoluminescent systems in the UK? Little or no knowledge of the material used or the system itself Easier to stick with a system that you know Fear of the system the unknown Work involved convincing the decision makers misconception that it costs more and is more likely to be vandalised However, the system can be seen (in the UK) on aeroplanes, passenger ships, Royal Navy ships and Army vehicles, where in most cases photoluminescent low level guidance systems are a legal requirement. It is also installed in a number of other UK locations, including a hospital and a large secondary school as well as a number of housing association buildings.

What the Law says The Regulatory Reform Fire Safety Order 2005 No.1541, Article 14.(2)(h) The legislation relating to emergency lighting is clearly stated ;...emergency routes and exits requiring illumination must be provided with emergency lighting of adequate intensity in the case of failure of their normal lighting The RRFSO 2005 does NOT state that the lighting must be electrical but more importantly it states that it must be of adequate intensity. In fact electrical emergency lighting could be deemed to be inadequate in a fire as it is most likely to be obscured by smoke.

Why fit a photoluminescent wayguidance system? It works and aids orientation and egress times during an emergency Provides for the visually impaired It requires little or no maintenance or operational admin and saves money Costs significantly less to install than electrical emergency lighting Difficult and less likely to be vandalised Recent Coroner inquests (Shirley Towers and Lakanal House, both cite building guidance as an issue that should be seriously considered, including easy to understand escape plans and even low level guidance)

The system has been accepted by the Fire Authority as an acceptable alternative to electrical emergency lighting. Please note that the Fire Authority is the enforcing authority for the Fire Safety Order and it is irrelevant which location or county it is in. It would be the same as saying that the police in Manchester have different rules to the police in London, which they don t. The important point is that the Fire Authority has confirmed that the system is acceptable instead of electrical emergency lighting and that it fulfils the requirements of the law.

Recent developments in low level guidance There have been 2 recent Coroner s inquests into 2 major fires in which 8 people have died. These inquests are; Shirley Towers Lakenal House In both cases there was confusion on how to exit the building. In the Shirley Towers inquest it was identified that low level guidance would have aided the fire-fighters and it was subsequently recommended in the Coroners recommendations - Rule 43.

Frequently asked questions FAQ s Is it easy to install? Is it compliant? What s the life expectancy? Is maintenance required? Is it robust? Does it achieve the required standards? EverGlow Hi150 answer Yes - It is very easy to install in any existing building and is generally fitted using 3M 468MP adhesive (the same adhesive used to fit number plates to cars) Yes - The system is already installed in The Royal Surrey County Hospital, Salvation Army sheltered housing blocks, Icknield School and in all cases there is no electrical emergency lighting present. 20 years (minimum) No except for a regular visual check to make sure it s there Yes - Aluminium product virtually vandal proof and scratch resistant. UPVC product is manufactured on anti-tamper tape. Yes - in fact it over achieves the British Standard for luminance by 14x after 10 minutes and 23x after 60 minutes (BS5266-6). It is also the only system tested to a European standard DIN 67 5170

Frequently asked questions FAQ s What s its decay time? Charge time & source? Does it work? Does it burn? Is it vandal proof? EverGlow Hi150 answer The EverGlow Hi150 system is visible for up to 35 hours before the luminance level falls below a level visible to the naked eye (0.32mcd) 20 minutes at 320 Lux (average office/communal space lighting) Source lighting can be incandescent light or natural daylight Yes - The system is currently used on aeroplanes, passenger ships, all US passenger trains and oil rigs. It is also a legal requirement in many countries around the world, including the USA, Japan and Germany. Yes like almost everything, it does burn but when it does burn it will be at temperatures above those where life can be sustained. (Aluminium at 365 degrees C and UPVC 160 degrees C). Yes - The system is pretty much vandal proof for a number of reasons, aluminium, anti tamper tape, etc. However it can be vandalised but it would take days to make the system inoperative.

Electrical Emergency Lighting installation & works TYPICAL ELECTRICAL EMERGENCY LIGHTING COSTS (Typical 20 storey block with 80 flats) Quantity Cost Cost per typical property Full EL system installation 1 100,000.00 100,000.00 EL unit replacement c.80 220.00 17,600.00 Electrical Emergency Lighting service & tests Quantity Cost per test Annual cost per property Monthly 10 40.00 400.00 6 monthly 1 75.00 75.00 Annually 1 250.00 250.00 Renew battery c.80 35.00 2,800.00 Renew EL bulb c.40 22.50 900.00 4,425.00

TYPICAL PHOTOLUMINESCENT LOW LEVEL GUIDANCE SYSTEM COSTS (Typical 20 storey block with 80 flats) Photoluminescent Quantity Cost Cost per typical 20 storey 4 flats per floor (80) Install Hi150 1 metre aluminium anti slip stair nosing (with 25mm photoluminescent insert) Supply and fit Hi150 wall markings per metre (estimated metres required) 247 45.00 11,115.00 800m 9.00 7,200.00 Supply and fit Hi150 25mm handrail markings 19 27.00 513.00 Supply and fit Hi150 25mm door edge markings 10 22.50 225.00 Supply and fit PL 75mm flat numbers 80 12.00 960.00 Supply and fit PL 100mm floor numbers (2 per floor 1 by lift and 1 by stairs to lobby) 38 20.00 760.00 Photoluminescent floor layout 20 45.00 900.00 21,673.00

OPENABLE WINDOWS - VENTING LIFT FLAT 41 FLAT 42 4 th FLOOR STAIRCASE FLAT 43 FLAT 44 OPENABLE WINDOWS - VENTING

London Borough of Barnet Barnet Homes

Salvation Army Housing Association, Bournemouth

Icknield High School, Luton

More locations where the system is fitted In addition to the above locations, Photoluminescent low level wayguidance systems are fitted in all of the following. (in some cases where there is no electrical emergency lighting): Kennedy Space Centre, USA Time Warner, USA Chinese National Theatre Chengdu Metro, China Beijing Olympic Stadium Beijing Olympic Hotel Nanboku and Odakyu Metro lines, Japan Shibuya and Meguro Stations, Tokyo Melbourne Cricket Ground, Australia United Nations building, USA The Pentagon, USA Jazz at The Lincoln Centre, New York Madison Square Gardens, USA Curran Theatre, San Francisco Gwinnet Centre, Georgia, USA The Convention and Exhibition Centre, Hong Kong The Eaton Centre, Toronto

Thank you For more information why not contact us Tel: 020 8440 2398 Mob: 07823 331846 email: info@eurocompliance.co.uk