SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Similar documents
Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Installation Instructions for the

FSS-SMT Series. Low Profile Force Sensor

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Selecting Honeywell Board Mount Pressure Sensors

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HIH-5030/5031 Series Low Voltage Humidity Sensors

TruStability Board Mount Pressure Sensors

HIH-4000 Series Humidity Sensors

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

FEATURES AND BENEFITS

Force Sensors Line Guide


MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

HIH-4602-L Series Humidity Sensors

Airflow Sensors Line Guide

Potential Applications

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Airflow Sensors Line Guide

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

V-Basic Standard V15 Series

MS4525 SPECIFICATIONS

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

WARNING MISUSE OF DOCUMENTATION

MSP100 Pressure Transducer

Board Mount Pressure Sensors Line Guide

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Linear Current Sensors

HOA6480 Series Barcode Sensor Infrared Products

MICRO SWITCH V15W Series Watertight Miniature Switches

HIH-4030/31 Series Humidity Sensors

86BSD Digital Output

HIH-4010/4020/4021 Series Humidity Sensors

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Heavy Duty Pressure Transducers

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Sensors in Ventilators

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

MICRO SWITCH GLL Series

86BSD Digital Output

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

High Temperature Industrial VRS Magnetic Speed Sensors

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Quadrature Speed and Direction Sensors

Installation Instructions for the 600 Series Optical Encoders

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Standard SPECIFICATIONS FEATURES APPLICATIONS

Wireless Panel-Mount Monitor

MSP100 Pressure Transducer

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

MICRO SWITCH GSX Series

DP86 Constant Voltage with Fitting

86BSD Digital Output

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Installation Instructions for the

Sensor Evaluation Kit, SEK001

HIH-4602 A & C Series.

General Purpose Industrial VRS Magnetic Speed Sensors

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Sub psi SPECIFICATIONS

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Intrinsically Safe Transmitters, Option Code 2n

Transcription:

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi DESCRIPTION The Standard Accuracy Silicon Ceramic (SSC) Series is a piezoresistive plastic silicon pressure sensor offering a ratiometric analog output for reading pressure over the specified full scale pressure span and temperature range. The SSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and non-linearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 1 khz. The SSC Series is calibrated over the temperature range of -20 C to 85 C [-4 F to 185 F]. The sensor is characterized for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc. FEATURES Industry-leading long-term stability Extremely tight accuracy of ±0.25 % FSS BFSL* Total error band of ±2 % full scale span maximum Modular and flexible design offer customers a variety of package styles and options, all with the same industryleading performance specifications Miniature 10 mm x 12,5 mm [0.39 in x 0.49 in] package Low operating voltage Extremely low power consumption Ratiometric 12-bit analog output Precision ASIC conditioning and temperature compensated over -20 C to 85 C [-4 F to 185 F] temperature range These sensors measure absolute, differential, and gage pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Differential versions allow application of pressure to either side of the sensing diaphragm. Gage and compound versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. The SSC Series sensors are intended for use with noncorrosive, non-ionic working fluids such as air and dry gases. They are designed and manufactured according to standards in ISO 9001. RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability Also available with I 2 C and SPI digital output, and in SMT and DIP packages Absolute, differential, gage and compound types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options * Full Scale Span Best Fit Straight Line

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors POTENTIAL APPLICATIONS Medical: - Airflow monitors - Anesthesia machines - Blood analysis machines - Gas chromatography - Gas flow instrumentation - Kidney dialysis machines - Oxygen concentrators - Pneumatic controls - Respiratory machines - Sleep apnea equipment - Ventilators Industrial: - Barometry - Flow calibrators - Gas chromatography - Gas flow instrumentation - HVAC - Life sciences - Pneumatic controls Table 1. Absolute Maximum Ratings 1 Parameter Min. Max. Unit Supply voltage (Vsupply) -0.3 6.0 V Voltage on any pin -0.3 Vsupply + 0.3 V Digital interface clock frequency I 2 C 100 400 khz SPI 50 800 ESD susceptibility (human body model) 3 - kv Storage temperature -40 [-40] 85 [185] C [ F] Peak reflow temperature - 250 [482] C [ F] Peak reflow duration - 15 s Table 2. Operating Specifications Parameter Min. Typ. Max. Unit Supply voltage (Vsupply) 2 3.3 V 5.0 V Sensors are either 3.3 or 5.0V based on model selected. Supply current 3.3 V supply 5.0 V supply 3.0 4.75-1.6 2.1 ma - 2 3 Compensated temperature range 4-20 [-4] 85 [185] C [ F] Operating temperature range 5-40 [-40] 85 [185] C [ F] Startup time (power up to data ready) 2.8 7.3 ms Response time 0.46 ms I 2 C or SPI voltage level low 0.2 % Vsupply I 2 C or SPI voltage level low 0.8 % Vsupply Pull up on SDA and SCL (I 2 C output only) 1 - - kohm Accuracy 6 - ±0.25 %FSS BFSL Total Error Band 7 ±2 %FSS 8 Output resolution 12 bits 3.3 3 5.0 3 3.3 5.25 Vdc Table 3. Environmental Specifications Parameter Humidity Vibration Shock Life 9 Characteristic 0 % to 95 % RH, non-condensing MIL-STD-202F, Curve AK (20.7 g random) MIL-STD-202F, Method 213B, Condition F 1 million cycles minimum 2 www.honeywell.com/sensing

±2 % Total Error Band, SMT and DIP, Digital Output, 1 psi to 150 psi Table 4. Wetted Materials 10 Parameter Port 1 (Pressure Port) Port 2 (Reference Port) Covers high temperature polyamide high temperature polyamide Substrate alumina ceramic alumina ceramic Adhesives epoxy, RTV epoxy, RTV Electronic components ceramic, glass, solder, silicon silicon, glass, gold, solder Notes: 1. Absolute maximum ratings are the extreme limits the device will withstand without damage. 2. Ratiometricity of the sensor (the ability of the device to scale to the supply voltage) is achieved within the specified operating voltage for each option. Other custom supply voltages are available, please contact Honeywell Customer Service. 3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits. 5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax) and minimum (Pmin) limits of the pressure range. (See figure 1 for ranges). 9. Life may vary depending on specific application in which sensor is utilized. 10. Contact Honeywell Customer Service for detailed material information. Honeywell Sensing and Control 3

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 1. Nomenclature and Order Guide Notes: 11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin and Pmax, the output at Pmin and Pmax the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other transfer functions are available. Contact Honeywell Customer Service for more information. 12. The output type defines which protocol the sensor uses to communicate. Available protocols are I 2 C and half duplex SPI (slave only). Communication protocol is not field-selectable and should be defined when ordering the sensor. 13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information. 14. See Table 5 for an explanation of sensor types. 4 www.honeywell.com/sensing

Figure 2. Transfer Functions and Limits ±2 % Total Error Band, SMT and DIP, Digital Output, 1 psi to 150 psi Figure 3. Completed Catalog Listing Example SSCMANN0100PBGSA3: SMT, AN ports, no diagnostics, 100 psi gage sensor, 10 % to 90 % calibration at 3.3 V, SPI output. SSCMANN0100PBGSA3 Output vs. Pressure 100 90 Output (% of 2 14 counts) 80 70 60 50 40 30 20 10 2 % FSS Total Error Band 0 0 10 20 30 40 50 60 70 80 90 100 Pressure (psig) Table 5. Sensor Types Pressure Type Transfer Function Absolute Output is proportional to the difference between applied pressure and a built-in reference to vacuum. Pmin is set at absolute zero pressure (full vacuum). Compound Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Pmin is set at -15 PSIG, referenced to atmospheric pressure. Differential Output is proportional to the difference between the pressures applied to each port. (Port1 Port2) 50% point of transfer function set at Port1 = Port2. Gage Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Pmin is set at atmospheric pressure. Honeywell Sensing and Control 5

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Table 6. Sensor Output at Significant Percentages % Output Digital Counts (decimal) Digital Counts (hex) 0 0 0x0000 10 1638 0x0666 50 8192 0x2000 90 14746 0x399A 100 16383 0x3FFF Table 7. Pressure Range Specifications Pressure Pressure Range Range Order Code Pmin Pmax Overpressure 14 Burst Pressure 15 Common Mode Pressure 16 Long-term Stability (1000 hr, 25 C [77 F]) Absolute 005AP 0 psi A 5 psi A 30 psi A 40 psi A NA ±0.35 % 015AP 0 psi A 15 psi A 30 psi A 60 psi A NA ±0.25 % 030AP 0 psi A 30 psi A 60 psi A 120 psi A NA ±0.25 % 060AP 0 psi A 60 psi A 120 psi A 240 psi A NA ±0.25 % 100AP 0 psi A 100 psi A 250 psi A 250 psi A NA ±0.25 % 150AP 0 psi A 150 psi A 250 psi A 250 psi A NA ±0.25 % Differential 001PD -1 psi 1 psi 10 psi 10 psi 150 psi ±0.35 % 005PD -5 psi 5 psi 30 psi 40 psi 150 psi ±0.35 % 015PD -15 psi 15 psi 30 psi 60 psi 150 psi ±0.35 % Gage 001PG 0 psi 1 psi 10 psi 10 psi 150 psi ±0.35 % 005PG 0 psi 5 psi 30 psi 40 psi 150 psi ±0.35 % 015PG 0 psi 15 psi 30 psi 60 psi 150 psi ±0.35 % 030PG 0 psi 30 psi 60 psi 120 psi 150 psi ±0.35 % 060PG 0 psi 60 psi 120 psi 240 psi 150 psi ±0.35 % 100PG 0 psi 100 psi 250 psi 250 psi 250 psi ±0.35 % 150PG 0 psi 150 psi 250 psi 250 psi 250 psi ±0.25 % Compound 030PC -15 psi 30 psi 60 psi 120 psi 150 psi ±0.25 % 060PC -15 psi 60 psi 120 psi 240 psi 150 psi ±0.25 % 100PC -15 psi 100 psi 250 psi 250 psi 250 psi ±0.25 % 150PC -15 psi 150 psi 250 psi 250 psi 250 psi ±0.25 % Notes: 15. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. 16. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 17. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance. Table 8. Pinout for All Port Styles Output Type Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 I 2 C ground Vsupply SDA SCL NC NC NC NC SPI ground Vsupply MISO SCLK SS NC NC NC 6 www.honeywell.com/sensing

±2 % Total Error Band, SMT and DIP, Digital Output, 1 psi to 150 psi Figure 4. Package Dimensional Drawings (For reference only: mm [in]) (Other package combinations are possible, please contact Honeywell Customer Service.) SMT NN Pressure Port: Flat Covers, No Pressure Port SMT AN Pressure Port: Axial, Single Port Honeywell Sensing and Control 7

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 4. Package Dimensional Drawings (continued) SMT RN Pressure Port: Radial, Single Port SMT RR Pressure Port: Radial, Dual Ports on Same Side 8 www.honeywell.com/sensing

±2 % Total Error Band, SMT and DIP, Digital Output, 1 psi to 150 psi Figure 4. Package Dimensional Drawings (continued) SMT DR Pressure Port: Radial, Dual Ports on Opposite Sides DIP NN Pressure Port: Flat Covers, No Pressure Port Honeywell Sensing and Control 9

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 4. Package Dimensional Drawings (continued) DIP AN Pressure Port: Axial, Single Port DIP RN Pressure Port: Radial, Single Port 10 www.honeywell.com/sensing

±2 % Total Error Band, SMT and DIP, Digital Output, 1 psi to 150 psi Figure 4. Package Dimensional Drawings (continued) DIP RR Pressure Port: Radial, Dual Ports on Same Side DIP DR Pressure Port: Radial, Dual Ports on Opposite Sides Honeywell Sensing and Control 11

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828; +65 6445-3033 Fax Europe +44 (0) 1698 481481; +44 (0) 1698 481676 Fax Latin America +1-305-805-8188; +1-305-883-8257 Fax USA/Canada +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008173-2-EN IL50 GLO Printed in USA July 2009 2009 Honeywell International Inc.