Eurys Series. User Guide. Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm)

Similar documents
Faraday Isolator. Low Power ISO Series User s Manual

Faraday Isolator. Broad-Band ISO Series User s Manual

M12 Class 1 Laser Emitter

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

M12 Class 2 Laser Emitter

LASER SAFETY BARRIER

LIMITED LIFETIME WARRANTY

52 SAN LUCAS CEILING FAN

PM-200 Power Module Operating Instructions

IC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 ICS6-MB, ICS8-MB

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

9780 SW Freeman Dr. Wilsonville, OR USA Tel: Fax: crimsontrace.com Rev002 12/15

52 BAYTOWNE CEILING FAN

LIMITED LIFETIME WARRANTY

Fibrlok II 2529 Universal Optical Fiber Splice

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

USER S OPERATING AND INSTRUCTION MANUAL

MicrOTDR. Optical Fault Locator. User Manual

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Multi-Tech S1000 / S1000-Ultra Air Purifier

Rutgers Environmental Health and Safety (REHS)

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

SUTTON 52 CEILING FAN

Multi Line Laser Level Model: L203

VX SERIES Wireless Thermostat with Occupancy Sensor

100 Ft. LASER DISTANCE METER

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Printed in U.S.A Rev. A 6/2005 0B

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Here is what comes in your box:

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY

HW-17 Record Cleaning Machine Setup and Instruction Manual

52 BARSTOW CEILING FAN

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Industrial Vacuums, Inc

COMPACT FLAME CONTROLLER CFC 2000

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Torrena 42 Ceiling Fan

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Camarillo 52 Ceiling Fan

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

TOUCHDOWN 48 CEILING FAN

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

HXL. Operating instructions

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Optical Time Domain Reflectometry (OTDR)

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

48 TAYLOR CEILING FAN

Lifetime Limited Warranty

52 STRATHMERE CEILING FAN

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Variable Temperature Digital Solder and Desolder Station

West Virginia University Laser Safety Program

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

G4 Pulsed Fiber Laser

STYLE 3678 Conquest and 3878 Vanquish SST Monitor MOTOR DRIVE COUPLING REPLACEMENT INSTRUCTIONS

DUST FREE CARBON Whole House Air Purifier

Preamplifier Power Supply PPS-02 user's guide

HEAT PRESS USER S GUIDE

Fiber Optics and Liquid Level Sensors Line Guide

External Wireless Sounder

LIMITED LIFETIME WARRANTY

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

Stand Fan. English. Owner s Guide. Model F R

HFX Fiber Optic Component 50 Mbps, 650 nm LED

MINI-BEAM Expert Series

52 BERKSHIRE CEILING FAN

Lifetime Limited Warranty

COMPACT FLAME CONTROLLER CFC 1000

SeedVac TM REF 90091

SPRINGHILL 44 CEILING FAN

RT User Guide. Self-leveling, remote-controlled, simultaneous level and plumb rotational laser system

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

TrueClean ToteCleaner

installation, operation & Maintenance manual Floor-mounted Induction units

PROFESSIONAL SERIES PENDANT SPEAKER PS-P63T

Battery Powered In-line Valve with Watering Timer RBC 7000

ST. KITTS CEILING FAN

Instruction Manual. Self-Leveling Laser Level Model No

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Owner s Manual for the Cordless Backpack

ITEM # SAIL STREAM CEILING FAN MODEL #40048

ELSTON 52 CEILING FAN

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

For use with models: BP , BP , BP

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

6502B RF Distribution

Transcription:

Eurys Series User Guide Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm) (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 9

Thank you for purchasing your Eurys Series Faraday Rotator or Optical Isolator from EOT. This user s guide will help answer questions you may have regarding the safe use and optimal operation of your device. TABLE OF CONTENTS I. Eurys Series Optical Isolator Overview... 2 II. Safe Use of your Eurys Series Optical Isolator... 2 III. Using your Eurys Series Faraday Rotator... 3 IV. Using your Eurys Series Optical Isolator... 4 V. Installation of your device... 7 VI. Warranty Statement and Repair... 7 VII. Specifications: Eurys Series Broadband Faraday Rotators and Optical Isolators... 8 I. Eurys Series Optical Isolator Overview The Eurys Series Faraday Rotators are optical assemblies that rotate the polarization of light 90 clockwise from input to output using the Faraday Effect. This is accomplished through the use of a proprietary optical material mounted inside a magnetic assembly. The Optical Isolators build on the technology found inside Faraday Rotators by adding two high power polarizers creating an optical assembly that is polarization-dependent and allows transmission of light in only one direction with minimal losses. As an additional benefit, Eurys Series Optical Isolators have been designed to reject any isolated light orthogonally to the input beam with a pointing accuracy of < 5mrad. This allows for efficient optical isolation of subsystems or for passing high power beams to beam traps. Finally, the products have been designed with several mounting options. These include a precision mounting option for customers who are interested in a drop-in alignment solution. II. Safe Use of your Eurys Series Optical Isolator Due to the powerful magnetic field that exists inside the products, care must be taken while working within their vicinity. Please carefully review the following warnings and recommendations. Failure to follow these recommendations may result in permanent damage to the product or serious injury to the user. 1. Ferromagnetic tools and objects should not be used or placed in the proximity of the rotators and isolators. These items will be forcefully attracted to the internal magnets, causing damage or injury. 2. Do not pick up the isolator by its ends where the magnetic field and risk of attraction to other objects is the greatest. (800)697-6782 sales@eotech.com www.eotech.com Page 2 of 9

3. Never attempt to disassemble your device. The internal magnets will be ejected outward possibly causing serious injury. 4. The port covers should be opened if any of the following conditions are met: a. Forward propagating beam >25W average power b. Reverse propagating beam >1W average power c. Reverse pulsed energy density > 0.15 J/cm² @ 10ns pulse width Once opened, it is the responsibility of the user to properly terminate all beams in a safe manner. 5. Always wear personal protective equipment that provides protection against the wavelengths and powers being used in your application. 6. Never sight through the products to align them with laser sources or other optical components. 7. Personnel with any magnetically-sensitive implants such as pacemakers should consult their medical doctor regarding any potential complications which could arise from the isolator s external magnetic fields. 8. Keep all magnetically-sensitive materials and devices such as watches, computer hard drives, and magnetic strips away from the products. III. Using your Eurys Series Faraday Rotator Figure 1: Eurys Series Faraday Rotator Your rotator has been optimized at the factory to provide 90 clockwise, non-reciprocal rotation of linearly polarized light from the input to the output at the ordered wavelength and operating temperature. (800)697-6782 sales@eotech.com www.eotech.com Page 3 of 9

EOT recommends that light is injected into the input side of the device (Figure 1) and that the customer carefully aligns the rotator to the beam path to insure optimal performance. Please see the product data sheet for typical performance curves and the product drawings for mounting options and physical dimensions. 3D CAD files are available upon request. Please contact EOT with any additional questions regarding your Faraday Rotator. IV. Using your Eurys Series Optical Isolator Figure 2: Eurys Series Optical Isolator Your Optical Isolator has been optimized at the factory to provide optimal isolation and transmission at the ordered polarization orientations, operating temperature, and wavelength. In addition, the factory has aligned the input polarizer to provide precision pointing of the isolated light (Figure 3), providing a drop-in solution for OEM customers needing to pass light to subsystems or beam traps. In a typical application, light traveling from the input to the output (forward light) will pass with minimal losses while reverse light will be highly attenuated. If the port covers are opened, this attenuated or isolated light will be rejected as shown in Figure 3. EOT recommends that the customer carefully aligns the Optical Isolator to the beam path to insure optimal performance. Numbering Fields and Coordinate System for Eurys Series 1010-1080nm Optical Isolator General Format for Numbering Field: AA-BB-C-DDD-EEE-FFF Field Description: 1. AA is the product type. BB = broadband. (800)697-6782 sales@eotech.com www.eotech.com Page 4 of 9

2. BB is the aperture size. 05 = 5mm. 3. C is the device type. I = isolator; R = rotator 4. DDD is the operating wavelength in nm. 5. EEE is the input polarization axis angle. A right hand X, Y, Z Cartesian coordinate system is used, in which the direction of beam propagation away from the laser source is along the positive Z axis. The X axis is in the plane of the baseplate. The Y axis is vertical, normal to the plane of the baseplate. The XY plane forms the plane of polarization. The XZ plane forms the plane of the baseplate. As an example, a horizontal input polarization is 000 or 0 degrees. A vertical polarization is 090, or 90 degrees. If no polarization is selected by the customer, 000 will be assigned. For rotators, this field does not apply. 6. FFF is the output polarization, which is 90 degrees from the input polarization if no waveplate is used. If a waveplate is used and no output polarization is specified, the default setting is the input polarization plus 180 degrees. The angle convention is the same as described for EEE. For rotators, this field does not apply. Y-axis=090 Positive Z-rotation +Z-axis = Direction of Beam Propagation (Direction of arrow on device) X-axis=000 Laser Source (800)697-6782 sales@eotech.com www.eotech.com Page 5 of 9

Figure 3: Light Propagation through Optical Isolators Port Covers: EOT recommends opening the port covers on your Optical Isolator if any of the following conditions exist in your application. Failure to open the ports when recommended may result in either poor performance or product failure. Forward propagating beam >25W average power Reverse propagating beam >0.5W average power Reverse pulsed energy density > 0.15 J/cm² @ 10ns pulse width Once opened, the port covers reveal four ports as shown in Figure 3. If incorrectly aligned with the source or if the reverse light has been depolarized, the discarded light ports may contain a significant amount of power. It is the customer s responsibility to analyze their specific application and to properly manage the light from all ports on the product. To open or close the port covers: Loosen the port-cover screw using an M2 hex wrench. Rotate the port cover until the optical ports are open or closed. Retighten the port-cover screw using an M2 hex wrench. o Recommended torque: 2.5 in-lbs. Waveplate Tuning: If your device was ordered with a λ/2 waveplate, it was factory adjusted to provide the output polarization as ordered. (800)697-6782 sales@eotech.com www.eotech.com Page 6 of 9

If additional tuning of the output polarization is desired: Close the output-port cover per the instructions. o This reveals an M3 set screw which secures the waveplate holder (Figure 4). Loosen the set screw with an M1.5 hex wrench. Adjust the waveplate holder to the desired output polarization (Figure 4). Tighten the set screw with an M1.5 hex wrench. o Recommended torque: 2.5 in-lbs. V. Installation of your device Figure 4: Waveplate Tuning The products are fully compatible with both metric and English breadboards. For OEM customers, EOT recommends installing the products using the precision dowel pin holes provided on the bottom of the clamp. EOT uses these features during final testing and use of this mounting option will provide drop-in precision. For more information, please see the drawing. VI. Warranty Statement and Repair EOT warrants its products to be free from defects in material and workmanship and complies with all specifications. EOT will at its option, repair or replace any product or component found to be defective during the warranty period. This warranty applies only to the original purchaser and is not transferrable for a period of one year after date of original shipment. The foregoing warranties shall not apply, and EOT reserves the right to refuse warranty service, should malfunction or failure result from: a. Damage caused by improper installation, handling or use. b. Unauthorized product modification or repair. c. Operation outside the environmental or damage specifications of the product. d. Contamination not reported to EOT within 30 days of the original ship date. e. EOT s output isolators contain a spacer at the end of the isolator. Under certain conditions, an off-axis back-reflection from the workpiece could focus down onto (800)697-6782 sales@eotech.com www.eotech.com Page 7 of 9

the output displacer or polarizer inside the isolator. The purpose of the spacer is to eliminate the conditions under which this could happen. Should EOT s output isolators be purchased without the spacer, or should the spacer be removed, damage to the output displacer or polarizer will not be covered under warranty and the customer will be responsible for all costs associated with such an occurrence. This warranty is exclusive in lieu of all other warranties whether written, oral, or implied. EOT specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. In no event shall EOT be liable for an indirect, incidental, or consequential damages in connection with its products. If the customer believes there is a problem with the rotator/isolator, they should immediately contact EOT s Sales/Customer department at 231-935-4044 or customerservice@eotech.com. EOT s Customer Service department will either issue an RMA for the device, or provide the customer with a procedure and authorize the customer to modify the device. All returns should reference the RMA number on the outside of the shipping container and should be sent to: Attn: Sales/Customer Service 3340 Parkland Ct. Traverse City, MI 46986 USA EOT reserves the right to inspect rotators/isolators returned under warranty to assess if the problem was caused by a manufacturer defect. If EOT determines the problem is not due to a manufacturer defect (an example would be damage to an optical element caused by impact from a loose ball driver or exceeding the damage threshold of the device), repairs will be done at the customer s expense. EOT will always provide a written quote for repair prior to performing repairs at the customer s expense. Never attempt to disassemble the magnetic housing of your Faraday Rotator/Isolator. Injury could result. Any indications that an attempt to disassemble the magnetic housing was made will render the warranty null and void. VII. Specifications: Eurys Series Broadband Faraday Rotators and Optical Isolators Rotator Isolator Center Wavelength 800nm 800nm Spectral Range 720-950nm 720-950nm Polarizer Type N/A SF1 Glass Peak Transmission a >98% >92% Peak Isolation a N/A >33dB Damage Threshold a >3.5J/cm 2 at 10ns >3.5J/cm 2 at 10ns 1J/cm 2 at 8ps 1J/cm 2 at 8ps a At customer-specified wavelength and temperature (800)697-6782 sales@eotech.com www.eotech.com Page 8 of 9

Notes: 1. Operating Temperature: Performance of EOT s Faraday Rotators/Isolators is related to operating temperature. For information on the effect of operating temperature on EOT s Faraday Rotators/Isolators, please review our application note, Thermal Lensing Analysis of TGG. 2. For incident powers 50W, please consult EOT: You may either contact EOT s sales department at sales@eotech.com or view our Custom Products page on our website, www.eotech.com. 3. For apertures other than those specified: You may either contact EOT s sales department at sales@eotech.com or view our Custom Products page on our website. 4. Pulsed Damage Threshold: The pulsed damage threshold of your free space Faraday Rotator or Isolator can be determined at pulsewidths other than 10ns by using the Root T scaling method. (800)697-6782 sales@eotech.com www.eotech.com Page 9 of 9