Number of persons with a disability that live with a disability in your community?

Similar documents
ADA Checklist Transient Lodging, Hotels, Motels, Inns, Boarding Houses, Dormitories and similar facilities

Facilities Procedure for Accessibility or Compliance Related Requests:

Abbreviated Accessibility Checklist (Reception, Telephones, and Emergency Procedures) Reception Telephones

ADA Checklist AIRPORTS

MCB/DDS Partnership Orientation & Mobility/Low Vision Services

Home Safety Checklist From Adaptive Remodeling Solutions, LLC Monona, WI

difficulty arising from the seating. Consider using a suitable location as a quiet sick bay.

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

Cleaning Service Levels

Seniors Home Program

Aging-In-Place Remodeling Checklist

Creating the Accessible Home A One-Day Seminar

University of Delaware

WILLIAM & MARY CUSTODIAL TASK & FREQUENCY LIST. PUBLIC SPACE: ENTRANCES, LOBBIES, AND CORRIDORS Daily Weekly Monthly Quarterly Yearly

Building Regulations Part M 2004 Access To And Use Of Buildings Checklist Of Provisions/Areas For Consideration

For the Lifespan: The Caregiver Guide Module 4 The Accessible Home

Chapter 6: Plumbing Elements and Facilities. 603 Toilet and Bathing Rooms Wheelchair Accessible Compartment

Structure type: (2 story, ranch, bi-level, split level, I½ story, apt, duplex, town house) Location of house (rural, semi rural, suburban, urban)

Maintaining Seniors Independence Through Home Adaptations A SELF-ASSESSMENT GUIDE

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

Universal Design Recommendations for Accessible Housing. Mauricio A. Lizama, Ph.D., ATP

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

University of Wisconsin - Whitewater Universal Design Guidelines

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

Bath Planning Worksheet

Electrical Information

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

Allisonville Elementary School Facilities Highlights Built: 1960 Last Major Renovation: 28 years ago Capacity: 650 Current Enrollment: 767

HOME EVALUATION & ASSESSMENT FOR INDEPENDENT LIVING & ACCESSIBILITY

GENERAL GROUNDS. Inspector Name: Inspector Signature:

BURLEIGH MANOR MIDDLE SCHOOL HOWARD COUNTY PUBLIC SCHOOL SYSTEM

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

UMass Amherst Standard Procedures

Home Evaluation Questionnaire for PLOF

Home Safety Checklist

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

PLAN REVIEW SUBMITTAL GUIDE

Accessible Home Design and Remodel Checklist

SPACE TYPE: JUDICIAL CHAMBER

Planning Guide for the Refurbishment, Renovation, or Construction of Instructional Space Environments

EQUIPMENT GUIDE LIST - CHAPTER

SMART Access Assessment

Dementia Design Checklist (Revised)

MEDIA CENTER September 30, 2010

Environmental Safety Risk Assessment Inpatient Behavioral Health Settings (Compiled from tools in the public domain)

MD-CU 29 4 ANTIMICROBIAL COPPER ALLOYS AND ASSOCIATED FABRICATED PRODUCTS MASTER LABEL AND ASSOCIATED FABRICATED PRODUCTS

Access Specifications

Furniture LOT 1-6. LOT 1: Textiles, curtains and bedding. Fitted Bed Sheet, Cotton, various colors, No. Item Picture Samples. Double Bed.

Facilities, Custodial Services

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

Solutions and Cost Estimates Johnson Gill Annex and Courthouse 1 Kings Highway Middletown, NJ

GENERAL ASSIGNMENT CLASSROOM DESIGN STANDARDS

Accessibility and design aesthetics do not have to be mutually

2015 Bernice Bienenstock Furniture Library Interior Design Competition

Access Statement Seagrass Cottage 29 Longbeach Drive Beadnell NE67 5EG. Pre-Arrival. Parking. Entrance to Property. Prepared 24.4.

Lowe s Accessible Home LIVE RIGHT. Solutions for life s changing needs

2012 B.C. Building Code Compliance Review (Division B Part 3)

Life Safety - Means of Egress/Exits NFPA 101

Judge s Checklist 2015 Bernice Bienenstock Furniture Library Interior Design Competition

Access Statement For Cobweb Cottage, Settle

Custodial- General Cleaning Duties

4.0 SERVICES AND SCHEDULE

3 St Helens Drive Seaham Co. Durham SR7 7PU. Company: Castledene Sales & Lettings Inspected by: Stuart Hutchinson

Staying Independent. A Fall Prevention Checklist

Custodial Guide

Housekeeping Specifications

A Home Safety Checklist

Beaufort County Community College. Maintenance and House Keeping Plan

Apartment Inventory Check-list

JANITORIAL SPECIFICATIONS

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

Access Statement for Craster Rocks

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

CUSTODIAL SERVICES CUSTOMER SERVICE GUIDE

Visual Assessment of Cleanliness

Group Organizers: Let s Get Started!

EXHIBIT A-1 CITY OF BELLFLOWER JANITORIAL MAINTENANCE SPECIFICATIONS

CHECKLIST FOR OBSERVATION MONITORING

Michigan State University Barrier-Free/Accessibility Project Status Summary March 2017

HOW TO USE THIS CHECKLIST TO IDENTIFY HOME HAZARDS TO PREVENT FALLS

PASSENGER RAIL NETWORK LIGHTING OF STATION ENVIRONMENT TO COMPLY WITH DISABILITY STANDARDS FOR ACCESSIBLE PUBLIC TRANSPORT

SMART Access Assessment

F & S Caretaking Department Design Standards For New or Renovated U of T Premises February 2015

RHBL 7325 ENVIRONMENTAL ANALYSIS. By: Whitney Musick

Access Statement Shoreline Apartment 3 Church Street Craster NE66 3HT

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF HEALTH

BC Building Code Checklist Part 3 Planning and Development Department

G W C C GREENMOUNT WEST COMMUNITY CENTER GWCA - COMMUNITY CENTER. design recommendations

SMART Access Assessment

Plumbing Guidelines 2012 IBC/ANSI A

Residential Care Facilities Requirements

This access statement is available on our website and in the Welcome File in the cottage.

Checklist. Your Home Safety. Staying On Your Feet. A few simple steps can make your home safer and help prevent you from falling

Environmental Guidance Checklist

Transcription:

Building name: re Dame Location: Owen Sound Assessment by: Cathy Smart Date: August 25, 2003 Total number of students: 378 Number of students living with a disability? Deaf/Hard of hearing Blind/Low vision Physical Developmental Number of employees living with a disability? Deaf/Hard of hearing Blind/Low vision Physical Developmental Number of community events that occupy the school annually? Number of persons with a disability that live with a disability in your community? Deaf/Hard of hearing Blind/Low vision Physical Developmental es: Level of Accessibilty: Bruce-Grey - re Dame.doc Page 1 of 10 2003/10/01

es / Required Building Approach & Entrance 1 - Wheelchair parking spot(s)? - Upright wheelchair parking signs? - Each spot 2400mm (95 ) wide plus 1500mm (60") side access? - Located near accessible entrance? - Located on firm level surface? 2 - Curb ramp to front door - Maximum slope 1:12 ratio - Is it a barrier-free path on a firm, slip resistant surface? 3 - Are there ramps and curb cuts at other appropriate doors? (e.g. JK door, alternate bus door, portables) 4 - Transition at ramp < 13mm (½ )? 5 - Railing on ramp? 6 - Non-slip surface on ramp? Entrance Doors 7 - Threshold < 13mm (½ )? - Door width at least 860mm (34 )? 8 - Automatic entrance doors? 9 - Good location & timing of button? 10 - Signage for button - Is the door clearly marked with the international access symbol? Exterior and Fire Doors 11 - Do they operate smoothly? 12 - Is the spring load set at the appropriate strength? Bruce-Grey - re Dame.doc Page 2 of 10 2003/10/01

Stairwells 13 - Non-slip treads? es / Required 14 - Railings on both sides of staircase and landings? 15 - Adequate lighting? School Area Hallways 16-2.44-3.66m (8-12 ft.) wide? es / Required 17 - Free of obstructions? (i.e. any horizontal projections more than 100mm (4") that start above 680mm (2 3 )) 18 - Circle mirrors for blind corners? 19 - Doorways > 860mm (34") wide? 20 - Wheelchair turnaround room 1500mm (5')? Bruce-Grey - re Dame.doc Page 3 of 10 2003/10/01

es / Required Portables 21 - Doorways > 860mm (34") wide? 22 - Threshold < 13mm (½ )? 23 - Landing large enough to allow for wheelchair entrance? 24 - P.A. System? School Area es / Required Gymnasium Change Room 25 - to washroom fixtures? Girls washroom only. 26 - to clothing storage (i.e. hooks, lockers)? 27 - to shower? Stage 28 - Handrails on both sides of stairs? 29 - Ramps (correct ratio) or lift? 30 - Adequate lighting? Bruce-Grey - re Dame.doc Page 4 of 10 2003/10/01

es / Required Library Pits 31 - handrail? 32 - ramps max. slope 1:12? 33 - adequate lighting? 34 - visual contrast at top step? 35 - Adequate space around shelves? 36 - Security gates / turnstiles? Library Facilities 37 - check out / return counter? 38 - photocopier? 39 - computers? 40 - study tables? School Area es / Required Elevator/Lift 41 - Location - near exit? - Clear door width > 910 mm (36 )? 42 - close to washroom? 43 - Key access at wheelchair height? 44 - Delayed door closure? 45 - Alarm button/phone? Bruce-Grey - re Dame.doc Page 5 of 10 2003/10/01

es / Required Wheelchair Washroom 46 - Wheelchair accessible stalls on each floor? 47-1.5m (5ft.) turnaround room in stall? Appropriate fixtures: 48 - Wheelchair toilet 450mm (18 )? 49 - Sink with lever handles or infrared sensor? 50 - Paper towel rack and/or air dryer? 51 - Soap dispenser at appropriate height and manageable? Needs to be lowered. 52 - Wheelchair accessible sink with 680mm (2 3 ) knee space? 53 - Mirror at 1m (3 3 )? 54 - Grab bar on dividing wall? - 750mm (2 5 ) to 850mm (2 8 ) height? - > 1.04 m (3 5 ) beside the toilet to allow for a lateral transfer? 55 - Grab bar on wall behind toilet? 56 - Door position, spring & swing out hinges allow for wheelchair entrance? 57 - Alarm button by toilet? 58 - Hot water temperature < 50 C (120 F)? Bruce-Grey - re Dame.doc Page 6 of 10 2003/10/01

Requires Modification Classrooms 59 - Lever handles? 60 - Knob handles? Wheelchair 61 - Computer Lab? 62 - Science Labs? Depending on disability 63 - Photography? 64 - Tech. Shops? 65 - Kitchens? 66 - Space to move about classroom? Classroom equipment accessible 67 - pencil sharpener? 68 - sinks? 69 - desks? 70 - shelves? 71 - computers? 72 - personal belonging storage? 73 - gathering area? 74 - chalk boards? 75 - Light switches <1220mm (48 )? 76 - Fire alarm pull station, <1220mm (48 )? Bruce-Grey - re Dame.doc Page 7 of 10 2003/10/01

Health/Special Needs Change Room 77-860mm (34 ) clear door opening? 78 - Wall mounted change table? Bed 79 - Privacy curtain? Door 80 - Storage area and turnaround room for Hoyer Lift or ceiling lift? 81 - Locked storage for supplies? 82-1.5m (5ft.) turnaround room? 83 - Wheelchair accessible sink? 84 - Hot water temperature < 50 C (120 F)? 85 - Alarm Buzzer to main office? 86 - Access door lockable? Requires Modification Bruce-Grey - re Dame.doc Page 8 of 10 2003/10/01

Requires Modification Office/Work Room 87 - filing cabinets? 88 - photocopier? 89 - work station? 90 - P.A. system? 91 - door width 34 (860mm)? 92 - passageways 34 (860mm)? 93 - washroom? School Area Requires Modification Staff Room? 94 - door width 34 (860mm)? 95 - furniture i.e. table, phone, bulletin board? 96 - kitchen sink? 97 - appliances? 98 - mail boxes? Bruce-Grey - re Dame.doc Page 9 of 10 2003/10/01

Additional Information 99. Does the building have an accessible telephone? No 100. Is a TTY phone available for persons with hearing impairments? No 101. Does the facility include any tactile signage or detectable warning systems for persons with visual impairments? No Suggestions/Recommendations: 1. Install upright universal access parking sign. 2. Install contrasting carpet on the riser in the library. 3. Install lever handles in accessible washrooms. 4. Lower soap dispenser to meet CSA B-651 standard. Comment: Overall, a very accessible school. Bruce-Grey - re Dame.doc Page 10 of 10 2003/10/01