Level Alarm Control. Blender Accessories U S E R G U I D E UGB

Similar documents
Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

SPI Communications Option

Central Distribution System

TLR Model Tube Loaders

Carousel Plus Dryer. W Series Models 15, 25, 50, 75 and 100 with DC-1 Controls

D Carousel Dryer - DC-1

DM-1 Drying Monitor U S E R G U I D E UGD

EZLoad Models EZL-2 and EZL-5

Model DM3-i Drying Monitor

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

D Carousel Dryer - DC

SC Carousel Dryer. Models 7.5 and 15, with PLC controls. Installation. Maintenance. Operation. Troubleshooting

TOUCHDOWN 48 CEILING FAN

MDH Series Air Dryer. User s Guide

TLM Model Tube Loaders

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Introduction... 1 System Overview... 1 System Diagram... 2

USER MANUAL SAVE THESE INSTRUCTIONS

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

60In. Ceiling Fan. Owner s Manual

SUTTON 52 CEILING FAN

ELSTON 52 CEILING FAN

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

SAVE THESE INSTRUCTIONS

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

SPRINGHILL 44 CEILING FAN

Please record your equipment s model and serial number(s) and the date you received it in the spaces provided.

User s Manual & Operating Instructions

VM-WA525-S / VM-WA65-S VM-WA8-S SHAKER SERIES 2-WAY HIGH PERFORMANCE IN-WALL SPEAKER

CM Carousel Dryer. Standard Models CM100, 150, 200, 300 and 400. Installation. Maintenance. Operation. Troubleshooting

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Instructions and Operations Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Dashley Outdoor Fire Table

52 CEILING FAN. Owner s Manual Models #50336, 50337

P6500W Air Dryer User s Guide

Owner s Manual PCS PRO

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

MT Vacuum Sizing Tanks with manual control, optional potentiometer control, or optional PAVC control

VSA Series Air Dryer. User s Guide

52 BARSTOW CEILING FAN

INSTALLATION INSTRUCTIONS

HI Industrial Utility Heater HI Soleus Air International

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

22In. Oscillating Pedestal Fan. Owner s Manual

Series: MBC1-TC Mini Benchtop Temperature Controller

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

P4200PM / P5000PM Remote Air Dryer User s Guide

Model 405 AIRGARD Fume Hood Monitor

XT Series Thermostats

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

VACUUM LOADERS GSL Series

Inline Heater for Solvent or Gas. Installation and Operation Manual

Model TWBS.EW.H Tempered Water Blending System

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

18 INCHES, OSCILLATING STAND FAN

MaxLite LED Vapor Tight Linear Fixture

DIGITAL. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS2054DF84DF18DFE0809 ENGLISH

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Stoneridge Fire Pit High Dining Table Assembly Instruction

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

High-Velocity Floor Fan

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

TFD-1 Installation & User s Guide

92831 TEL: (714) FAX:

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

INSTALLATION AND INSTRUCTION MANUAL

Manual for MC91 SETUP INSTRUCTIONS

52 SAN LUCAS CEILING FAN

Manual update 2016 MC37/MFC3600

Propane Fume Detection System

Panel Mounted Heat Exchangers by Dantherm, Inc.

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

VT SERIES VERTICAL TOASTER OPERATOR S MANUAL TABLE OF CONTENTS

ACT Cartridge Dust Collector

Installation & Maintenance Instructions

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

User s Manual and Operating Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Transcription:

www.conairgroup.com U S E R G U I D E UGB015-1007 Level Alarm Control Blender Accessories Corporate Office: 724.584.5500 Instant Access 24/7 (Parts and Service): 800.458.1960 Parts and Service: 814.437.6861

Please record your equipment s model and serial number(s) and the date you received it in the spaces provided. It s a good idea to record the model and serial number(s) of your equipment and the date you received it in the User Guide. Our service department uses this information, along with the manual number, to provide help for the specific equipment you installed. Please keep this User Guide and all manuals, engineering prints and parts lists together for documentation of your equipment. Date: Manual Number: UGB015-1007 Serial Number(s): Model Number(s): DISCLAIMER: Conair shall not be liable for errors contained in this User Guide or for incidental, consequential damages in connection with the furnishing, performance or use of this information. Conair makes no warranty of any kind with regard to this information, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose. Copyright 2007 l Conair l All rights reser ved

Table of Contents 1-1 Introduction 2-1 Description 3-1 Installation Purpose of the user guide................................ 1-2 How the guide is organized.............................. 1-2 Using the Level Alarm Control............................. 1-3 Your responsibilities as a user............................. 1-3 ATTENTION: Read this so no one gets hurt................... 1-4 How to use the lockout device............................ 1-5 What is the Level Alarm Control?...........................2-2 Specifications: Level Alarm Control......................... 2-3 Unpacking the boxes.................................... 3-2 Preparing for installation................................. 3-2 Installation........................................... 3-3 Mounting........................................ 3-3 Capacitance sensors............................... 3-4 Connecting capacitance sensors to the Level Alarm Control... 3-5 Detachable capacitance sensors........................ 3-5 Connecting main power.................................... 3-6 110V/60Hz......................................... 3-6 220V/50Hz......................................... 3-6 4-1 Operation Preparing the Level Alarm Control for operation............... 4-2 Level Alarm Control operation............................. 4-3 Level Alarm Control alarm acknowledgement................. 4-5 Adjusting the capacitance sensor.......................... 4-6 Dry contacts connection................................. 4-7 Additional warning outputs............................... 4-7 Table of Contents l i

5-1 Maintenance Preventative maintenance checklist........................ 5-2 Replacing the fuse..................................... 5-3 6-1 Troubleshooting Before Beginning....................................... 6-2 Before you begin troubleshooting..................... 6-2 A few words of caution............................ 6-2 Troubleshooting........................................ 6-3 A B A ppendix We re here to help..................................... A-1 How to contact customer service.......................... A-1 Before you call......................................... A-1 Equipment guarantee.................................. A-2 Performance warranty.................................. A-2 A ppendix Installation and wiring diagram guides...................... B-1 Models TB45, TB100 and TB250...................... B-1 Models TB500-4, TB500-6, TB900-4 and TB-900-6....... B-2 Models TB1800-4, TB1800-5, TB1800-6, TB2500-4, TB2500-5 and TB2500-6....................... B-3 ii l Table of Contents

S E C T I O N 1 Introduction 1 Introduction Purpose of the user guide.............. 1-2 How the guide is organized............. 1-2 Using the Level Alarm Control........... 1-3 Your responsibilities as a user........... 1-3 ATTENTION: Read this so no one gets hurt........ 1-4 How to use the lockout device........... 1-5 Introduction l 1-1

Purpose of the User Guide This User Guide describes the Level Alarm Control (LAC-1) and explains step-by-step how to install, operate, maintain and repair this equipment. Before installing this product, please take a few moments to read the User Guide and review the diagrams and safety information in the instruction packet. You also should review manuals covering associated equipment in your system. This review won t take long, and it could save you valuable installation and operating time later. How the Guide is Organized Symbols have been used to help organize the User Guide and call your attention to important information regarding safe installation and operation. Symbols within triangles warn of conditions that could be hazardous to users or could damage equipment. Read and take precautions before proceeding. 1 Numbers indicate tasks or steps to be performed by the user. u r 0 A diamond indicates the equipment s response to an action performed by the user. An open box marks items in a checklist. A circle marks items in a list. 2 Indicates a tip. A tip is used to provide you with a suggestion that will help you with the maintenance and the operation of this equipment. Indicates a note. A note is used to provide additional information about the steps you are following throughout the manual. 1-2 l Introduction

Using the Level Alarm Control Each Level Alarm Control (LAC-1) is designed to work within a blending system or other similar applications consisting of: TrueBlend Blenders (TB45-TB3500 models) Non-Conair blenders Non-blender applications 1 Introduction Separate instructions are provided for TrueBlend blenders and should be referred to as needed to fully understand the operation of the entire system. Your Responsibility as a User You must be familiar with all safety procedures concerning installation, operation and maintenance of this equipment. Responsible safety procedures include: Thorough review of this User Guide, paying particular attention to hazard warnings, appendices and related diagrams. Thorough review of the equipment itself, with careful attention to voltage sources, intended use and warning labels. Thorough review of instruction manuals for associated equipment. Step-by-step adherence to instructions outlined in this User Guide. Introduction l 1-3

ATTENTION: Read this so no one gets hurt We design equipment with the user s safety in mind. You can avoid the potential hazards identified on this machine by following the procedures outlined below and elsewhere in the User Guide. WARNING: Improper installation, operation, or ser vicing may result in equipment damage or personal injur y. This equipment should be installed, adjusted, and serviced by qualified technical personnel who are familiar with the construction, operation, and potential hazards of this type of machine. All wiring, disconnects, and fuses should be installed by qualified electrical technicians in accordance with electrical codes in your region. Always maintain a safe ground. Do not operate the equipment at power levels other than what is specified on the machine serial tag and data plate. WARNING: Voltage hazard This equipment is powered by single-phase alternating current, as specified on the machine serial tag and data plate. CAUTION: Voltage hazard Always disconnect and lock out the main power sources before making electrical connections. Electrical connections should be made only by qualified personnel. 1-4 l Introduction

How to Use the Lockout Device CAUTION: Before performing maintenance or repairs on this product, you should disconnect and lockout electrical power sources to the blender to prevent injury from unexpected energization or start-up. A lockable device has been provided to isolate the blender from potentially hazardous electricity. Lockout is the preferred method of isolating machines or equipment from energy sources. Your Conair product is equipped with the lockout device pictured below. To use the lockout device: 1 Introduction 1 Stop or turn off the equipment. 2 Isolate the equipment from the electric power. Turn the rotary disconnect switch to the OFF, or O position. 3 Secure the device with an assigned lock or tag. Insert a lock or tag in the holes to prevent movement. 4 The equipment is now locked out. WARNING: Before removing lockout devices and returning switches to the ON position, make sure that all personnel are clear of the machine, tools have been removed, and all safety guards reinstalled. To restore power to the dryer, turn the rotary disconnect back to the ON position: 1 Remove the lock or tag. 2 Turn the rotary disconnect switch to the ON or I position. Introduction l 1-5

1-6 l Introduction

S E C T I O N 2 Description What is the Level Alarm Control?......... 2-2 Specifications: Level Alarm Control....... 2-3 2 Description Description l 2-1

What is the Level Alarm Control? The Conair Level Alarm Control (LAC-1) is a simple-to-use early warning detection system for your blending equipment that is capable of monitoring up to six levels of material at one blender with an extra input for auxiliary needs, typically a surge bin or other material supply. Selector switches can be positioned to monitor high or low material levels depending on your preference or blender application. Audible and visual alarms indicate an excess or shortage of material within a blender. The alarm indicates exactly which material bin is alarming with an associated LED. Optional remote warning alarms can be connected to your control to alert you to alarm conditions from remote locations with audible and/or visual indicators. 2-2 l Description

Specifications: Level Alarm Control MODELS LAC-1 Dimensions inches {mm} A - Height 10.5 {267} B - Width 5.2 {132} C - Depth 5.0 {127} Approximate weight lb {kg} Installed 7 {3.2} Shipping 17 {7.7} Voltages full load amps* 110V/1 phase/60hz 5 220V/1 phase/50hz 2.5 Line voltage output* 110V/1 phase/60hz (2) 110V @ 2.5 amps 220V/1 phase/50hz (2) 220V @ 1.3 amps Dry contact voltage outputs 24VDC @ 8 amps 115VAC @ 10 amps 9.75 in. {247.6 mm} 4.25 in. {107.9 mm} A ø0.31 in. {8.0 mm} 2 Description SPECIFICATION NOTES: *The line voltage output is determined by the voltage requirements of the LAC-1. Specifications can change without notice. Contact a Conair representative for the most current information. APPLICATION NOTE: The Level Alarm Control module has seven (7) capacitance sensor connections. Up to six (6) can be used for the monitoring of material levels. The seventh sensor can be used with a surge bin or other material storage device located beneath the blender. The eighth connection is a dry contact output with (1) N.O. (normally opened) and (1) N.C. (normally closed) contact that can be connected to other processing equipment or monitoring devices. (For example, an output used with an alarm connected to a PC monitoring system.) B OPTIONS Sensor cable length extensions (6 m, 20 m) Additional capacitance sensors (for use with a surge bin or other material sources) Remote alarms (compatible with Conair s Universal Alarm Box) C TPBS036-1007 Description l 2-3

2-4 l Description

S E C T I O N 3 Installation Unpacking the boxes................. 3-2 Preparing for installation.............. 3-2 Installation........................ 3-3 Mounting...................... 3-3 Capacitance sensors.............. 3-4 Connecting capacitance sensors to the Level Alarm Control............ 3-5 Detachable capacitance sensors...... 3-5 Connecting main power............... 3-6 110V model.................... 3-6 220V model.................... 3-6 3 Installation Installation l 3-1

Unpacking the Boxes The Level Alarm Control (LAC-1) comes in one box. Depending on the model and options ordered, the box could include: Level Alarm Control Capacitance Sensors Wiring Diagram User Guide 1 Carefully remove the LAC-1 and its components from their shipping container(s). 2 Remove all packing material, protective paper, tape, and plastic. 3 Carefully inspect all components to make sure no damage occurred during shipping, and that you have all the necessary hardware. 4 Take a moment to record serial numbers and electrical power specifications in the blanks provided on the back of the User Guide s title page. The information will be helpful if you ever need service or parts. 5 You are now ready to begin installation. Preparing for Installation The Level Alarm Sensor (LAC-1) is easy to install if you plan the location and prepare the mounting area properly. 1 Make sure the mounting area provides: r A grounded power source supplying the voltage and correct current for the LAC-1. Check the control s serial tag for the correct amps, voltage, phase, and cycles. Field wiring should be completed by a qualified personnel to the planned location for the control. All electrical wiring should comply with your region s electrical codes. 3-2 l Installation r Minimum clearance for safe operation and maintenance. You should maintain 12 in. {305 mm} clearance on all sides of the LAC-1.

Installation Mounting When installing the Level Alarm Sensor (LAC-1) locate the control on the left-side of the blender cabinet. This is to ensure adequate spacing and visibility. The Level Alarm Control (LAC-1) mounts to the blender cabinet using four (4) self-tapping ø0.31 inch {8 mm} screws. Mounting location of the LAC-1 will be dependent upon blender model. Refer to your installation diagram (#611-280) and Appendix B for model specific mounting location recommendations. WARNING: You are responsible for the structural integrity of this installation. 2 TIP: Install the LAC-1 to the blender cabinet before making any wire connections. 3 Installation Front Left-side as viewed from the front door To mount the LAC-1 control box: 1 Locate the proper mounting area on the left-side of the blender s cabinet. Refer to your installation diagram (#611-280) and Appendix B for model specific mounting location recommendations. 2 Use the four (4) supplied self-tapping screws to secure the control box to the blender s cabinet with an appropriately sized wrench or socket. Installation l 3-3

Installation Capacitance Sensors Individual capacitance sensors will need to be mounted to the blender s bin or sight glass to monitor material levels within the blender s material bin. To mount the capacitance sensor: 1 Locate the material bin(s) that are to be monitored (up to 6 with 1 additional sensor for auxiliary use). Sight glass Plastic washer (2) 2 Remove the blender s sight glass(es), if the sensors are to be mounted in the sight glass. Do this by removing the screws and internal retaining clip that secures the sight glass to the material bin or locate and drill a 1-3/16 inch {30.2 mm} hole as shown on the installation diagram #611-280 (shipped with your equipment). 3 Using the LAC-1 s supplied sight glass(es) or the 1-3/16 in. {30.2 mm} hole in the bin, mount the capacitance sensor, by inserting the sensor through the predrilled hole. 4 Use one (1) of the supplied plastic washers on the sensor to set the depth the sensor will protrude into the material bin (0.875 inch {22.2 mm} is recommended), by rotating the bolt clockwise or counterclockwise along the sensor s threaded section. 5 Use the second plastic washer on the opposite side of the sight glass or bin to secure the sensor into place, tighten. 6 Rotate the sight glass 180 to change the monitored level of material within the blender s material bin. Depending on the amount of material that is required, the sensor location can be changed to high or low by rotating the sight glass. 7 Reattach the new sight glass along with the capacitance sensor back to the blender s sight glass opening, using original hardware. Ensure that the internal retaining clip is in place and that all the hardware has been used. 0.875 in. 3-4 l Installation

Installation Connecting Capacitance Sensors to the Level Alarm Control Each capacitance sensor will need to be connected to the LAC-1 (1-7). Individual wires with connectors are used to make this connection. Ensure proper wiring by matching the material bin number with the correct connection terminal on the LAC-1. Connection Terminals Connector 3 Installation To connect the capacitance sensors: 1 Use the supplied wiring and connector that is attached to each sensor to plug into the corresponding terminal found on the LAC-1 (1-7). Screws (2) 2 Use the integrated screws (2) to the tighten the sensor s connector to the LAC-1. Use an appropriately sized screwdriver. Installation Detachable Capacitance Sensors Capacitance sensors are available with detachable cables to allow easy material bin removal on blender models with removable bins. The sensor s connectors attach to the LAC-1 using the same method described above. However, the detachable sensor will have an additional connector inline on the sensor cable. To connect the inline cable connector: 1 Connect the male and female connectors of the detachable sensor cable. 2 Tighten the the two (2) screws on the sensor s male connector to the female connector with an appropriately sized screwdriver. Installation l 3-5

Connecting Main Power 110V/60Hz CAUTION: Always disconnect and lock out the main power sources before making electrical connections. Electrical connections should be made only by qualified personnel. IMPORTANT: Always refer to the wiring diagrams that came with your equipment to locate specific electrical components. Illustrations and photographs in the User Guide are intended only to be representative only. WARNING: Improper installation, operation, or ser vicing may result in equipment damage or personal injur y. This equipment should be installed, adjusted, and serviced by a qualified technical personnel who is familiar with the construction, operation and potential hazards of this type of machine. All wiring, disconnects, and fuses should be installed by a qualified electrical technician in accordance with electrical codes in your region. To connect the LAC-1 to power source: 1 Connect the LAC-1 s plug into a 110V power source. Connecting Main Power 220V/50Hz WARNING: Improper installation, operation, or ser vicing may result in equipment damage or personal injur y. This equipment should be installed, adjusted, and serviced by a qualified technical personnel who is familiar with the construction, operation and potential hazards of this type of machine. All wiring, disconnects, and fuses should be installed by a qualified electrical technician in accordance with electrical codes in your region. To connect the LAC-1 to power source: 1 Refer to the wiring diagrams that were shipped with your LAC-1 for the proper wiring procedures. It is necessary to add a plug to the supplied wiring harness for the 220 V LAC-1 model. (Brown wire is positive, blue is negative and green/yellow is ground.) 3-6 l Installation

S E C T I O N 4 Operation Preparing the Level Alarm Control for operation...................... 4-2 Level Alarm Control operation........... 4-3 Level Alarm Control alarm acknowledgement................ 4-5 Adjusting the capacitance sensor......... 4-6 Dr y contact connections............... 4-7 Additional warning outputs............. 4-7 4 Operation Operation l 4-1

Preparing the Level Alarm Control for Operation Before operation of the Level Alarm Control (LAC-1): 1 Turn the all High/Low monitoring switches to Off, by positioning the switch to its center. 2 Turn the main power On/Off toggle switch to On. A LED indicator light above the word Power will be illuminated to show that the LAC-1 is activated. Audible Alarm Indicator Power LED Indicator Visual Alarm Indicator Power On/Off Toggle Switch 3 Setup and enable the capacitance sensors to detect either high, low or no (Off) material levels within your blender s hopper bins, by using the toggle switches located on the front of the LAC-1. See Operation Section entitled, Level Alarm Control Operation. High/Low Level Monitoring Toggle Switches Alarm indicator LED (1-7) 4-2 l Operation

Level Alarm Control Operation The Level Alarm Control (LAC-1) can be configured to monitor high or low material levels within a blender or other material bins. For blenders with high throughputs the LAC-1 s capacitance sensors can be located higher on the blender s material sight glass or bin to provide earlier warning for material levels. Refer to LAC-1 mounting and wiring diagrams and Appendix B for capacitance sensor installation/wiring. See also, Installation Section in this manual entitled, Installation, Capacitance Sensors. For applications that require lower blender throughputs the capacitance sensor can be located lower on the blender s material sight glass or bin. Refer to LAC-1 mounting and wiring diagrams and Appendix B for capacitance sensor installation/wiring. See also, Installation Section in this manual entitled, Installation, Capacitance Sensors. 4 Operation (continued) Operation l 4-3

Level Alarm Control Operation (continued) The LAC-1 can be configured to monitor high or low levels of material with a blender s material hopper. By using the toggle switches located on the front of the control the capacitance sensor will trigger an alarm if the material falls below the sensor (Low) or rises above the sensor (High). Individual LED indicators on the LAC-1 s control will illuminate displaying the exact capacitance sensor and associated material bin hopper that has alarmed. Alarm indicator LED Example of low sensor alarming. (sensor uncovered is an alarm) Alarm indicator LED Example of high sensor alarm. (sensor covered is an alarm) 4-4 l Operation (continued)

Level Alarm Control Operation (continued) To configure the monitoring method of each material bin (up to 6 and 1 auxiliary) on your blender: 1 Determine which material bin(s) on the blender require high or low material monitoring. 2 Select the position of the high or low toggle switch of the corresponding material bin hopper on the LAC-1 s front control. The LAC-1 has seven selectable material monitoring toggle switches. The seventh position can be used with an auxiliary source, such as a surge bin. The above procedure will still apply. Level Alarm Control Alarm Acknowledgement 4 Operation The LAC-1 will activate visual and audible alarm indicators when a material bin s material source is above or below its High or Low setting. To silence an alarm: 1 Press the Alarm Silence button located on the LAC-1 s control. 2 Determine which material bin(s) on the blender has alarmed by viewing the associated LED indicator located above the alarming material bin label. Operation l 4-5

Adjusting the Capacitance Sensor The LAC-1 s capacitance sensors will need to be adjusted to allow it to detect the material that you are blending or to detect different types of material. To adjust the capacitive sensor: 1 Locate the sensor adjustment screw that is positioned on the corded end of the sensor. 2 Adjustments should be made with no material in the bin. Adjust the sensor by rotating the screw clockwise for increased sensitivity until the sensor s LED is on, to decrease sensitivity rotate the screw counterclockwise to decrease sensitivity until the sensor s LED is off. In both cases, rotate the screw an additional 90 to allow for dust buildup and temperature changes. 0 NOTE: The sensors for this application are wired N.O. (normally open). The circuit will close and the sensor s LED will energize when material covers the sensor. Indication Light Adjustment Screw 4-6 l Operation

Dr y Contacts Connection The LAC-1 has one additional connection terminal that has one N.O. (normally open) and one N.C. (normally closed) dry contact that can be used to interface with other processing equipment or monitoring devices. Two dry contact voltages are available (24VDC @ 8 amps or 115VAC @ 10 amps). (i.e. an output used with an alarm connected to a PC monitoring system) See Installation Section entitled, Connecting Capacitance Sensors to the Level Alarm Control, for instructions to connect the Dry Contacts. Dry Contact Terminal (No. 8) Additional Warning Outputs Additional warning outputs are available to allow for additional blender material warning notification. Two outlets on the LAC-1 provide power for remote warning indicators. The top outlet will supply a line voltage of 110V or 220V power (depending on the LAC-1 model) until an alarm condition is activated. The bottom output will supply 110V @ 2.5 amps or 220V @ 1.3 amps power when an alarm condition has been activated. 4 Operation Satisfactory State Outlet Alarm State Outlet Operation l 4-7

4-6 l Operation

S E C T I O N 5 Maintenance Preventative maintenance checklist....... 5-2 Replacing the fuse.................. 5-3 5 Maintenance Maintenance l 5-1

Preventative Maintenance Checklist Routine maintenance will ensure optimum operation and performance of the Level Alarm Control (LAC-1). We recommend the following maintenance schedule and tasks. Ever y six months r Inspect all wiring connections Power and cable connections between the LAC-1 and the capacitance sensors may become loose or wires may become worn. Tighten any loose connections and replace any wire or cable that has become worn or damaged. r Inspect capacitance sensor mounting locations Check for loose or dirty capacitance sensors. Capacitance sensors that are dusty or dirty will trigger faults material level warning signals. r Inspect the installation Check installed LAC-1 hardware to make sure that the installation is secure. r Inspect the fuse Check LAC-1 s fuse, replace as necessary. 5-2 l Maintenance

Replacing the Fuse The Level Alarm Control requires a 5 amp fuse for the 110V model and a 2.5 amp fuse for the 220V model. To replace the fuse for either model: Replacement fuses are available from Conair. Contact Conair Parts (800) 458 1960 From outside of the United States, call: (814) 437 6861 1 Unscrew and remove the fuse cap at the bottom of the LAC-1. Fuse Cap CAUTION: Always disconnect and lock out the main power sources before making electrical connections. Electrical connections should be made only by qualified personnel. 2 Remove the old fuse. Ensure to replace the fuse with the same amperage rating as the fuse that is being removed. 3 Replace fuse cap. IMPORTANT: Always refer to the wiring diagrams that came with your equipment to locate specific electrical components. Illustrations and photographs in the User Guide are intended only to be representative only. 5 Maintenance Maintenance l 5-3

5-4 l Maintenance

S E C T I O N 6 Troubleshooting Before Beginning.................... 6-2 Before you begin troubleshooting...... 6-2 A few words of caution............. 6-2 Troubleshooting.................... 6-3 6 Troubleshooting Troubleshooting l 6-1

Before Beginning You can avoid most problems by following the recommended installation and maintenance procedures outlined in this User Guide. If you do have a problem, this section will help you determine what caused it and how to fix it. Before you begin troubleshooting: o Find the wiring diagrams that were shipped with your equipment. These diagrams are the best reference for correcting a problem. The diagrams also will note any custom features, such as special wiring or control options, not covered in this User Guide. o Verify that you have manuals for other equipment in the process line. Solving problems may require troubleshooting malfunctions or incorrect operating procedures on other pieces of equipment. A Few Words of Caution WARNING: This machine should be adjusted and serviced only by qualified technical personnel who are familiar with construction and operation of this type of equipment. WARNING: Voltage hazard. Troubleshooting the electrical system of this equipment requires use of precision electronic measuring equipment, and may require access to the electrical enclosure while power is on. Exposure to potentially harmful voltage levels may be unavoidable. These troubleshooting procedures should be performed only by qualified electrical technicians who know how to use this precision electronic equipment and who understand the hazards involved. WARNING: Disconnect power and compressed air before servicing. Always disconnect and lock out power and compressed air supplied to this equipment before performing maintenance or repair. Failure to do so could result in personal injury caused by the unexpected energization of this equipment. CAUTION: Wear eye protection. If you use compressed air to clean the equipment, you must wear eye protection and observe all OSHA and other safety regulations pertaining to the use of compressed air. 6-2 l Troubleshooting

Troubleshooting Problem Possible cause Solution The LAC-1 will not monitor material bin levels No power to the LAC-1 Turn on the power and check the power LED. See Operation Section entitled, Preparing the Level Alarm Control for Operation. Ensure main fuse is operating. See Maintenance Section entitled, Replacing the Fuse. Ensure the LAC-1 has power, see Installation Section entitled, Connecting Main Power. Capacitance sensor s connection may be loose. Check all capacitance sensor connections, resecure if necessary. Capacitance sensor is not adjusted properly. Readjust capacitance sensor. See Operation Section entitled, Adjusting the Capacitance Level Sensor. Excessive alarm indications. Capacitance sensor is too low or too high in the blender s sight glass or bin. Adjust the capacitance sensor s height within the sight glass or bin. See Installation Section entitled, Installation, Capacitance Sensor. Capacitance sensor is not adjusted properly. Readjust capacitance sensor. See Operation Section entitled, Adjusting the Capacitance Level Sensor. LAC-1 does not alarm before the blender runs out of material. Capacitance sensor is too low in the blender s sight glass or bin. Adjust the capacitance sensor s height within the sight glass or bin. See Installation Section entitled, Installation, Capacitance Sensor. 6 Troubleshooting Capacitance sensor is not adjusted properly. Readjust capacitance sensor. See Operation Section entitled, Adjusting the Capacitance Level Sensor. Troubleshooting l 6-3

Additional manuals and prints for your Conair equipment may be ordered through the Customer Service or Parts Department for a nominal fee. We re Here to Help Conair has made the largest investment in customer support in the plastics industry. Our service experts are available to help with any problem you might have installing and operating your equipment. Your Conair sales representative also can help analyze the nature of your problem, assuring that it did not result from misapplication or improper use. How to Contact Customer Ser vice To contact Customer Service personnel, call: 0 NOTE: Normal operating hours are 8:00 am - 5:00 pm EST. After hours emergency service is available at the same phone number. From outside the United States, call: 814-437-6861 You can commission Conair service personnel to provide on-site service by contacting the Customer Service Department. Before You Call... If you do have a problem, please complete the following checklist before calling Conair: r Make sure you have all model, control type and serial numbers from the serial tag, and parts list numbers for your particular equipment. Service personnel will need this information to assist you.. A- 1 l A ppendix r Make sure power is supplied to the equipment. r Make sure that all connectors and wires within and between control systems and related components have been installed correctly. r Check the troubleshooting guide of this manual for a solution. r Thoroughly examine the instruction manual(s) for associated equipment, especially controls. Each manual may have its own troubleshooting guide to help you. r Check that the equipment has been operated as described in this manual. r Check accompanying schematic drawings for information on special considerations.

Equipment Guarantee Conair guarantees the machinery and equipment on this order, for a period as defined in the quotation from date of shipment, against defects in material and workmanship under the normal use and service for which it was recommended (except for parts that are typically replaced after normal usage, such as filters, liner plates, etc.). Conair s guarantee is limited to replacing, at our option, the part or parts determined by us to be defective after examination. The customer assumes the cost of transportation of the part or parts to and from the factory. Performance Warranty Conair warrants that this equipment will perform at or above the ratings stated in specific quotations covering the equipment or as detailed in engineering specifications, provided the equipment is applied, installed, operated and maintained in the recommended manner as outlined in our quotation or specifications. Should performance not meet warranted levels, Conair at its discretion will exercise one of the following options: Inspect the equipment and perform alterations or adjustments to satisfy performance claims. (Charges for such inspections and corrections will be waived unless failure to meet warranty is due to misapplication, improper installation, poor maintenance practices or improper operation.) Replace the original equipment with other Conair equipment that will meet original performance claims at no extra cost to the customer. Refund the invoiced cost to the customer. Credit is subject to prior notice by the customer at which time a Return Goods Authorization Number (RGA) will be issued by Conair s Service Department. Returned equipment must be well crated and in proper operating condition, including all parts. Returns must be prepaid. Purchaser must notify Conair in writing of any claim and provide a customer receipt and other evidence that a claim is being made. Warranty Limitations Except for the Equipment Guarantee and Performance Warranty stated above, Conair disclaims all other warranties with respect to the equipment, express or implied, arising by operation of law, course of dealing, usage of trade or otherwise, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. A ppendix l A- 2

Installation and Wiring Diagram Guides Models TB45, TB100 and TB250 NOTE: Large format wiring diagrams were shipped with your equipment. ABOVE CONTROL BOX Additional wiring diagram copies are available from Conair Contact Conair Service (800) 458 1960 From outside of the United States, call: (814) 437 6861 DWG. REV: 611280-A 0 B- 1 l A ppendix

Installation and Wiring Diagram Guides Models TB500-4, TB500-6, TB900-4 and TB900-6 NOTE: Large format wiring diagrams were shipped with your equipment. Additional wiring diagram copies are available from Conair Contact Conair Service (800) 458 1960 From outside of the United States, call: (814) 437 6861 3" TYP. 3 3 2 1/8" TYP. 1 1/4" TYP. 4 " TYP. 1 2 3 3/4" TYP. 1 2 SENSOR 2,3 WIRE SENSOR 4,5 WIRE SENSOR 2,3 WIRE 3" TYP. 1 3/16" DIA. 1 3/16" DIA. TYP. TYP. 4 3 12 5 8 " FRONT 12 5 8 " FRONT 5 7 8 " 5 7 8 " TB500-4 BLENDER TB500-6 BLENDER NOTE: ALL WIRING TO BE ROUTED NOTE: ALL WIRING TO BE ROUTED BEHIND POSITION 1,2 BIN & BEHIND POSITION 1,2 BIN & ABOVE CONTROL BOX ABOVE CONTROL BOX 5 3 4 " TYP. 6" TYP. 3/4" TYP. 1 3/4" TYP. 1 2 3" TYP. 1 2 3" TYP. SENSOR 2,3 WIRE SENSOR 4,5 WIRE SENSOR 2,3 WIRE 1 3/16" DIA. 1 3/16" DIA. TYP. TYP. 4 3 19 5 8 " 19 5 FRONT 8 " FRONT 7 5 8 " 7 5 8 " TB900-4 BLENDER TB900-6 BLENDER NOTE: ALL WIRING TO BE ROUTED NOTE: ALL WIRING TO BE ROUTED BEHIND POSITION 1,2 BIN & BEHIND POSITION 1,2 BIN & ABOVE CONTROL BOX ABOVE CONTROL BOX DWG. REV: 611280-A 0 6 6 5 5 4 3 4 3 A ppendix l B- 2

Installation and Wiring Diagram Guides Models TB1800-4, TB1800-5, TB1800-6, TB2500-4, TB2500-5 and TB2500-6 NOTE: Large format wiring diagrams were shipped with your equipment. Additional wiring diagram copies are available from Conair Contact Conair Service (800) 458 1960 From outside of the United States, call: (814) 437 6861 15" TYP. 1 3/16" DIA. 8" TYP. 1 3/16" DIA. 7 3/4" TYP. 4" TYP. TYP. 1 2 TYP. SENSOR 1 WIRE SENSOR 4 WIRE SENSOR 3 WIRE SENSOR 2 WIRE 1 2 SENSOR 1 WIRE SENSOR 4 WIRE SENSOR 3 WIRE SENSOR 2 WIRE 4 3 4 3 39 5 8 " FRONT 51 5 8 " FRONT 3 3 8 " TB1800-4 BLENDER NOTE: ALL WIRING TO BE ROUTED ALONG HOPPER BASE TO ALARM BOX. 6 3 8 " TB2500-4 BLENDER NOTE: ALL WIRING TO BE ROUTED ALONG HOPPER BASE TO ALARM BOX. 7 3/4" TYP. 1 3/16" DIA. 1 1/4" 1 1/4" 7 3/4" 4" TYP. TYP. SENSOR 1 WIRE SENSOR 5 WIRE SENSOR 4 WIRE SENSOR 2 WIRE SENSOR 3 WIRE 15" TYP. 1 3/4" TYP. 1 3/16" DIA. 1 3/4" 15" 8" TYP. TYP. 3" 4" 8" SENSOR 1 WIRE SENSOR 5 WIRE SENSOR 2 WIRE SENSOR 4 WIRE SENSOR 3 WIRE 39 5 8 " FRONT 51 5 8 " FRONT 3 7 8 " TB1800-5 BLENDER NOTE: ALL WIRING TO BE ROUTED 6 3 8 " ALONG HOPPER BASE TO ALARM BOX. TB2500-5 BLENDER NOTE: ALL WIRING TO BE ROUTED ALONG HOPPER BASE TO ALARM BOX. 1 3/16" DIA. TYP. 4" TYP. 1 1/4" TYP. 7 3/4" TYP. 1 1/4" TYP. SENSOR 1 WIRE SENSOR 5 WIRE SENSOR 4 WIRE SENSOR 6 WIRE SENSOR 3 WIRE SENSOR 2 WIRE 1 3/4" 4" 15" TYP. 1 3/16" DIA. TYP. SENSOR 1 WIRE SENSOR 2 WIRE SENSOR 6 WIRE SENSOR 5 WIRE SENSOR 4 WIRE SENSOR 3 WIRE 3/4" TYP. 3" 4" 1 3/4" 15" 8" 39 5 8 " FRONT 51 5 8 " FRONT 3 7 8 " TB1800-6 BLENDER NOTE: ALL WIRING TO BE ROUTED 6 3 8 " ALONG HOPPER BASE TO ALARM BOX. TB2500-6 BLENDER DWG. REV: 611280-A NOTE: ALL WIRING TO BE ROUTED ALONG HOPPER BASE TO ALARM BOX. 0 6 1 5 5 1 4 4 2 2 3 3 6 1 5 5 1 4 4 2 2 3 3 B- 3 l A ppendix