Microprocessor Based Wye-Delta Reduced Current Type Starting

Similar documents
PILOT SERIES MPT700TS

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

Variable Frequency Drive SERIES MP800 VFD

MPT Electric Fire Pump Controller

MPT Electric Fire Pump Controller

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

LMR Electric Fire Pump Controllers Features

Drawing Submittal Package

Drawing Submittal Package

Transfer Switch Features

FDF Foam Pump Controllers Features

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

LMR Electric Fire Pump Controllers Features

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

FD30 Full Voltage - Across the Line July 2011

DIESEL Engine Fire Pump Controllers Features

FT60 Reduced Voltage - Autotransformer

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

Technical Data Submittal Document

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Powerohm Resistors Digital HRG System

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Fire Pump Controllers Medium Voltage Controllers

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

Transfer Switch Features

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

FT20 Full Voltage - Limited Service. Electrically and Mechanically

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Fire Pump Controllers Foam (Additive) Controllers

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

FTA550 JOCKEY PUMP CONTROLLERS

Guide Specification Model CTG Automatic Transfer Switch

DIESEL Engine Fire Pump Controllers Features

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

AS950 REFRIGERATED SAMPLERS

DGC-1000 DIGITAL GENSET CONTROLLER

Technical Data Submittal Documents

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

FDJ SERIES Jockey Pump Controllers Features

CAREL heatersteam Electric Element Steam Humidifiers

DGC-500 DIGITAL GENSET CONTROLLER

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

SECTION PACKAGED HEAT TRANSFER SYSTEM

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

METRON FIRE PUMP CONTROLS

PARAGON Commercial Refrigeration Controls

RELEASE DEVICE CONTROLS

SECTION AUTOMATIC TRANSFER SWITCHES

Specification/ Data Sheet

CommStat 4 Controller

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

EATON LMR Plus Electric Fire Pump Controllers

SECTION Fire Pumps

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

MODEL B2 INSTALLATION MANUAL

NS (A) ECN

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ACT2-CS Convenience Store Controller

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Two-Channel Gas Controller

Smart thermostat with Humidification/De-humidification control

CONTENTS AUTOMATIC TRANSFER SWITCHES

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

EasyTronic III MANUAL SERVICE

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Control Relay Modules

Comfort Control 2 HD Thermostat

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

SECTION AUTOMATIC TRANSFER SWITCHES

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Options for Diesel Fire Pump Controllers

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Emerson Blue Easy Set 1H/1C

TWLC - Tempered Water Logic Controller. The Intelligent Control

STR-Series Indirect-Fired Air Turnover Units

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

CPF PRODUCT DESCRIPTION

21-light Remote Annunciator. Owner s Manual

SECTION FIRE PUMP AND CONTROLS

PART GENERAL 1.01 SECTION INCLUDES

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

AS950 PORTABLE SAMPLERS

Transcription:

Metron Fire Pump Controls and Accessories NEW Microprocessor Based Wye-Delta Reduced Current Type Starting PRODUCT PILOT SERIES MPT430TS (Open Transition) - MPT435TS (Closed Transition) ONLY 32 WIDE WITH ATS Available in Across-The-Line, Soft Start, Wye-Delta Open & Closed Transition Starting Methods For Select Models, HP and Voltage Ranges Only Wye-Delta controllers require six leads from the motor to the controller. These leads are connected by the controller first in the Wye configuration which draws 33% of normal starting current and develops 33% of normal starting torque. After a short time delay, the controller then connects the motor winding in a Delta configuration, applying full voltage, drawing full load running current and developing full running torque. Metron s new patented fire pump controller with integral transfer switch is designed in a single narrow enclosure to reduce the amount of pump room space required. MPT700 Photo Shown PATENTED DESIGN AND TECHNOLOGY Only the highest quality components, UL Listed or Recognized, are used throughout to assure the best possible reliability. The cabinet is fabricated of heavy 12 gauge reinforced steel, with Type 3R supplied as standard and rated 60 C. All field wiring and service connections may be made from the front, allowing the controller to be mounted flush against a wall. Metron fire pump controllers conform to the latest requirements of the NFPA 20, UL 218 and FM 1321/1323, and bear the labels of Underwriters Laboratories and Factory Mutual. Controllers are completely wired, assembled, and tested at the factory before shipment and ready for immediate installation. MPT700TS Photo Shown MPT430-435TS 0218 UL218 FM1321/1323 MEMBERS

Metron Fire Pump Controls and Accessories Touch Screen Features Large 7 color LCD touch screen Simultaneous display on Home screen for 3 phase amperage/voltage, System pressure, Start Pressure, Stop pressure, System status, Alarm status, Transfer switch position, date and Time On-screen Icons for Pilot/Quick Start, System Set Points, User Settings, Data Log, Diagnostics, and others for ease of installation and data log/event history retrieval. Let Metron s Pilot feature guide you through the controllers startup settings. The Pilot feature guides the user automatically step-by-step through the settings required at start up. Searching through multiple menus to locate settings is eliminated. Pilot appears on the touch screen on initial power up, or by pressing the Pilot Icon. View data log/event history in Calendar screen to easily find a specific event by touching the day on the calendar month Multi level password protection 60 C rated with Type 3R enclosure as standard For added safety a through door USB port is provided to access data logs/event history without opening the controller door. Internal controller temperature monitored and data logged as standard Status LED s on PB board inputs/outputs provide visual indication of on/off status Pressure transducer fault LED System Self Test on power up Serial communication to PC boards reduces number of wire for improved reliability. Single logic control for operation of both the fire pump controller and transfer witch. Monitoring of the PC board inputs/outputs through the touch screen Monitor normal and emergency power sources simultaneously Phase rotation selectable through Pilot feature or Congif Icon Foreign language selectable Modbus communication Protocol via RS785 port Controllers are suitable for use as Service entrance equipment 600 PSI rating provided as standard. Utilizes a manifold block for the pressure transducer and drain solenoid valve that eliminates the need for copper plumbing with Teflon tape, significantly reducing the possibility of water leaks. Standard Features The Microprocessor based logic with real time/date clock capable of running 7+ years without AC power. Includes low battery indicator. The on-board data log memory can store up to 18 months of event history (approx. 112,000 events), and over 10 years of event history with a 2G USB Flash Drive. Data/Event log can store over 10+ years of time and date stamped events. Real time clock is accurate to plus/minus 2 minutes per year over the full temperature range. The event history can be viewed by scrolling on the display or by saving it to a USB flash drive. The event history is recorded as a.csv file and can be easily opened as an Excel file. MTS Automatic Transfer Switch Features The combination fire pump controller/automatic transfer switch is Listed with Underwriters Laboratories to UL 1008, Approved by Factory Mutual, and meets the latest requirements of NFPA 20. The transfer switch is a mechanically held double throw switch with a fast acting drive mechanism. The Metron MTS automatic transfer switch control functions are an integrated into the fire pump controllers main microprocessor control, eliminating the need for a separate transfer switch controller, reducing the number of components and wiring for improved reliability. Continues on next page... MPT430-435TS 0218 www.hubbell.com/metron/en

Metron Fire Pump Controls and Accessories Functions include transfer, retransfer and generator start adjustable time delays, generator start contacts, 3 phase voltage monitoring and frequency monitoring on Normal and Emergency power sources. Auxiliary Programs The controller includes as standard six (6) discrete auxiliary inputs and six (6) outputs. These auxiliary I/O are in addition to those required by NFPA 20 UL and FM. All auxiliary I/O can be field programmed on the touch screen. Expandable 12 channel I/O board for additional alarms, expandable to 168 I/O. All 48 aux programs can have a custom message. Events and Alarms Event Messages EVENT MESSAGES REMOTE TEST START MANUAL TEST START AUTO TEST START MODBUS TEST START REMOTE START MODBUS START HIGH ZONE CALL TO START DELUGE START PRESSURE TRANSDUCER FAILURE START SUPERVISORY POWER FAILURE START LOW PRESSURE START LOCAL START PUMP RUNNING CRR ENERGIZED/DE- ENERGIZED CSR ENGERGIZED/DE- ENERGIZED LOAD SHED SOFT START ON MANUAL STOP AUTO STOP ACCELERATION TIMER ON REMOTE LOCKOUT REMOTE LOCKOUT CLEARED DUMP VALVE OPENED DUMP VALVE CLOSED DUMP VALVE INSUFFICIENT DISCHARGE SYSTEM REBOOT Each record tracks: Date and Time Pressure Voltage and current for connected source Login state Pressure Internal temperature State of every alarm Which source the transfer switch is connected to. Whether normal/emergency power is available. The I/O state of all PCB's (excluding any add-on boards). Active start conditions. The state of all aux programs (48 aux programs available). Power available Alarm Messages Each alarm occurred or cleared PHASE FAILURE (NORMAL & EMERGENCY) PHASE REVERSAL (NORMAL & EMERGENCY) PHASE OVER/UNDER VOLTAGE (NORMAL & EMERGENCY) PHASE OVER/UNDER FREQUENCY (NORMAL & EMERGENCY) PRESSURE TRANSDUCER FAULT LOW/HIGH PRESSURE FAIL TO START FAIL TO STOP LOCKED ROTOR MOTOR OVERLOAD LOW SUCTION LOW ZONE FAIL TO START LOW ZONE QUIT SUPERVISORY POWER FAILURE GENSET FAIL TO START LOSS OF NORMAL POWER MPT435 -- Model Type *Options are listed on next page. Model Number Designation - xxx -- Horsepower Rating: 5-600 - XXX -- Voltage Rating: 200-480 VAC - B or C -- Example: MPT435-75-480C-H MTS Withstand Rating: B - 22,000 (@575 VAC) 50,000 (200-480 VAC) C - 100,000 (200-480 VAC) X -- *Option Designation(s) MTS -- With Transfer Switch Standard Withstand Ratings VOLTS 200-208 220-240 380-415 460-480 200-208 220-240 380-415 460-480 HP -- RMS SYMMETRICAL 15-150 -- 100kA 15-200 -- 100kA 15-300 -- 100kA 15-400 -- 100kA 200-250 -- 50kA 250-300 -- 50kA 350-350 -- 50kA 500-600 -- 50kA Information required with order: 1) Model Type 2) Motor Horsepower 3) Line Voltage, phase and frequency 4) Options, if any MPT430-435TS 0218 www.hubbell.com/metron/en

Metron Fire Pump Controls and Accessories Options Option H: Space Heater If the ambient atmosphere is especially damp, a space heater rated at 100 watts may be supplied to reduce moisture in the cabinet. A thermostat is supplied as standard with this option. A humidistat may be substituted if specified. Enclosure Options Type 3R is standard. The following UL Type enclosures are available: Type 4 Type 4X (painted cold roll steel) Type 4X (304 or 316 Stainless Steel) Type 12 Consult factory for additional options. US PATENTS US 7,762,786 B2 Integrated Fire Pump Controller and Automatic Transfer Switch vertical arrangement in a single enclosure. US 8,482,307 B2 Method For Prevention of Untested PC Boards from Being Used In A Fire Pump Control System. Contact Us NORTH & SOUTH AMERICA Hubbell Industrial Controls, Inc. Metron Fire Pump Control Division 4301 Cheyenne Dr., Archdale, NC 27263 Phone: 336-434-2800, Fax: 336-434-2801 salesmail@metroninc.com www.hubbell-icd.com EUROPE Metron Eledyne 18 Autumn Park, Dysart Road Grantham, Lincolnshire, NG31 7DD, United Kingdom Tel:+44 (0) 1476 516120, Fax:+44 (0) 1476 516121 info@metroneledyne.co.uk TAIWAN Hubbell-Taian Co. Ltd. Contact Person: Jimmy Wu Tel: (02)2522 1862 ext.10, Fax: (02)2522 1872 6th Floor, 156-1, Sung Chiang Road, Taipei, Taiwan jwu@hubbell-taian.com.tw CHINA Hubbell-Anmex (Shanghai) Trading Co., Ltd Contact Person: Derek Chen 6H, Zhao-Feng Universe Building, No. 1800, West Zhongshan Rd., Shanghai 200235, China Tel: 86-21-64400151, 64400156, Fax: 86-21-64400152 Mp: 86-13391373007 dchen@hubbell-anmex.com.cn PHILIPPINES Hubbell-Taian Co. Ltd. Philippine Representative Office Contact Person: Wency Villas-Besa Unit 23 Parc House Bldg, #227 EDSA, Greenhills, Mandaluyong City 1556, Philippines Tel: 632-6556460, Fax: 632-6556421 DL WL: 632-8717389 wency@hubbelltaian.com.ph www.hubbell.com/metron/en Hubbell Industrial Controls, Inc. 4301 Cheyenne Dr., Archdale, NC 27263 PH: 336-434-2800 FAX: 336-434-2809 Email: salesmail@metroninc.com MPT430-435TS 0218 Hubbell Incorporated. All rights reserved. Specifications subject to change without notice. Printed in USA.

2 DIMENSIONS & DATA ELECTRIC FIRE PUMP WITH TRANSFER SWITCH FM APPROVED 1 MPT300TS, MPT420TS, MPT430TS, MPT435TS, MPT700TS D D TOUCH SCREEN DIGITAL DISPLAY NORMAL SOURCE ISO/CB SWITCHES HANDLE 75.14 63.14.50" 3.0" RECOMMENDED CONDUIT ENTRANCE 55.15 ALARM HORN 29.85 DOOR HANDLE USB PORT 55.88 DOOR EMERGENCY SOURCE ISO/CB SWITCHES HANDLE C C 29.43 12.00 14.00 18.66 32.00 1/2" NPT FEMALE WATER CONNECTION SIDE VIEW MOUNTING BOLTS, 4 PLS FRONT VIEW 16.0" 6.0" RECOMMENDED CONDUIT ENTRANCE B 1.50 INLET OUTLET 16.00 8.49 A 3.0" 8.0" 18.66 B DETAIL A PLUMBING 4.18 32.00 BOTTOM VIEW A VOLTAGES 200V 208V 220-240V 380-415V 440-480V NOTES: ENCLOSURE MADE FROM 12GA. STEEL WITH HAMMER RED FINISH. ENTER CABLE(S) FROM BOTTOM HORSEPOWERS MPT300TS MPT420TS MPT430TS MPT435TS MPT700TS 5-60 5-60 5-60 5-60 5-40 5-60 5-60 5-60 5-60 5-50 5-60 5-60 5-60 5-60 5-50 5-100 5-100 5-100 5-100 5-75 5-150 5-150 5-150 5-150 5-100 PROTECT INTERNAL EQUIPMENT FROM DRILLING CHIPS DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE. ALWAYS CONSULT FACTORY TO CONFIRM CURRENT INFORMATION. TYPE 3R SHOWN. ALL DIMENSIONS IN INCHES. ALL DMENSIONS ARE SAME AFOR 3R, 12, 4 AND 4X ENCLOSURE TYPES. G:\DWG\DEPARTMENT_1\FirePump-Electric_Controller\MPT 2 Sales PDFs\HCMPTXXXTS.idw ENCLOSURE TYPES TYPE 3R CRS (STD) SHOWN TYPE 4 CRS TYPE 4X CRS TYPE 304 SS (PAINTED) TYPE 304 SS UNPAINTED TYPE 316 SS PAINTED TYPE 316 SS UNPAINTED DATE: SELECTION TABLE (CHOOSE FROM TABLES ON LEFT) CONTROLLER TYPE HP VOLTAGE ENCLOSURE TYPE MPT300TS MPT420TS MPT430TS MPT435TS MPT700TS CONTROLLER WITH MTS (METRON TRANSFER SWITCH) 5/15/2015 DRAWN BY: S. JUDD METRON Division of - Hubbell ICD, Inc. 4301 Cheyenne Drive Archdale, N.C. 27263 1 RATING: REV. N/A DRAWING NO. HCMPTXXXTS A