Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)

Similar documents
DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT

THE BASICS OF DECONTAMINATION

MANUAL CLEANING IS A VERY IMPORTANT PART OF THE

When you sterilize an instrument set, you know what the standards are.

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

CLEANING INSTRUCTIONS

2015 Myco Industries, Inc Fax:

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Instructions for Use Spinal Punches IFU

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Cleaning & Sterilization

The Principles, The Process, and The Results:

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

STERITITE INSTRUCTIONS FOR USE

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

Lower Your Costs. Expand Your Flexibility.

Surgical Instrument Cleaning Process

FLASH PAK STERILIZATION CONTAINER SYSTEM

CLEANING OF INSTRUMENTS

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

I.F.U Re/Processing Reusable Medical Devices

Lower Your Costs. Expand Your Flexibility.

Operating / User Manual

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

RECOMMENDATIONS FOR CLEANING DEVICES

Aesculap Implant Systems

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Developing the Solutions For You. Veterinary 2018 VETERINARY PRODUCT CATALOG

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Cleaning and disinfecting

Aesculap Implant Systems

Recommendations for cleaning, decontamination and sterilisation. devices

INFECTION PREVENTION AND CONTROL ON LINEN AND LAUNDRY MANAGEMENT. ROSAFE E. PERALTA, RN, MAN Chief Nurse MARYMOUNT HOSPITAL

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

PARTS CLEANING AND DEGREASING

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Processing instructions for the Ligamys suture forceps

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

Is Your Ultrasonic Cleaning System Living Up to Its Potential?

Instrument Cleaning Chemistries Automated Washing Process

DRAFT. Module 4. Decontamination & Environmental Cleaning

Cleaning Verification

BREAKTHRU Heavy Duty Liquid Detergent for Removal of Fatty Soils from Hard Surfaces

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

Disclosure. Today. Why are we here today. The College of Clean The Foundation Part 1. This is why you are here today. Watch this short video 3/26/2015

Bridging. the Gap. Health Care Environmental Services. Study Guide. Training Education and Developmental Series. Carts, Closets and Equipment

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Special Precautions Isolation Plan Environmental Services

Washroom care programs

Processing Instructions. Cleaning so easy.

PERFORM Operating Document

Publication No. AAMA Voluntary Guide Specification for Cleaning and Maintenance of Painted Aluminum Extrusions and Curtain Wall Panels

Reprocessing Reusable Medical and Dental Equipment: Policy and Protocols First Nations and Inuit Health Alberta Region

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

Developed by. Cleaning and Sanitation

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Effective Date: 0 8 / 1 0 / 1 7. Replaces: 08/11/16. Formulated:1997 SPECIAL (MEDICAL) WASTE MANAGEMENT

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

Transcription:

Lesson No. CIS 244 (Instrument Continuing Education - ICE) Sponsored by: by Donna Swenson, BS, CRCST, CHL, CSPDM Clinical Operations Manager Synergy Health PLC, Tampa, FL Decontamination Learning Objectives 1. Discuss basic factors that influence 2. Explain the importance of purified water in instrument cleaning processes 3. Identify common cleaning chemicals used for surgical instrumentation and review basic protocols for their use 4. Understand the difference between 5. Understand manual and mechanical cleaning, and when to use each process Instrument Continuing Education (ICE) lessons provide members with ongoing education in the complex and ever-changing area of surgical instrument care and handling. These lessons are designed for CIS technicians, but can be of value to any CRCST technician who works with surgical instrumentation. Earn Continuing Education Credits: Online: You can use these lessons as an in-service with your staff, or visit for online grading at a nominal fee. By mail: For written grading of individual lessons, send completed 15-question quiz and $15 to: PEC Business Office, Purdue University, Stewart Center Room 110, 128 Memorial Mall, West Lafayette, IN 47907-2034. Scoring: Each 15 question online quiz with a passing score of 70% or higher is worth two points (2 contact hours) toward your CIS re-certification (6 points) or CRCST re-certification (12 points). IAHCSMM provides online grading service for any of the Lesson Plan varieties. Purdue University provides grading services solely for CRCST and CIS lessons. More information: Direct any questions about online grading to IAHCSMM at 312.440.0078. Questions about written grading are answered by Purdue University at 800.830.0269. Devices that have not been ADEQUATELY cleaned cannot be disinfected or sterilized. Cleaning and decontamination is a multi-step process that begins at the point-of-use. From there, the instruments must be transported to the decontamination area where they undergo significant pre-cleaning activities, according to the manufacturers Instructions for Use (IFU), before the cleaning process can begin. After pre-cleaning, the appropriate cleaning process is required: manual soak/cleaning, ultrasonic wash, and/or washer/decontamination. Note: some devices may also require disinfection after cleaning. Each step is critical for ensuring that instrumentation is properly cleaned for subsequent disinfection and/or sterilization. Objective 1: Discuss basic FACTors that influence Point-of-Use Preparation Cleaning and decontamination should begin at the point-of-use. Dried-on soil is difficult to remove, requires more time to remove, and may damage the surface of some devices. Therefore, gross soil must be removed as soon as possible after use. IFU for each instrument explains pointof-use cleaning needs, and these must always be carefully followed. In general, gross soil must be removed, and instruments must be kept moist. Point-of-use preparation involves several steps. Non-reusable components, if any, must be removed and properly disposed, and fluids must normally be emptied from all containers. However, if they are needed during transport, such as for soaking instruments, the devices and fluids should be kept in a closed container to avoid spillage during transport. Separate reusable sharps to help prevent injuries. Keep items that belong in a set together, and tag/identify items that must be repaired. After point-of-use preparation is completed, instruments can then be transported to the decontamination area for further processing. Soiled Item Transport Instruments must be contained during transport to minimize contact or airborne spread of microorganisms. Enclosed carts can be used, but if open carts are used they should have a solid bottom shelf and the items should be covered. Carts and all containers used for transporting soiled devices should be cleaned after each use. If soiled items must be transported between buildings or campuses, one should consult US Department of Transportation (DOT) requirements for transportation of biohazardous materials. For example, clean and soiled items must be segregated if they are transported on the same truck at the same time. Applicable regulations are available from the DOT: Hazardous

Materials Regulation (HMR; 49 CFR Parts 100-180. Note: state and local requirements might also be applicable. Soiled items should be staged in a soiled holding area away from hallways or other high-traffic areas and locations, and away from cleaned items prior to transport. Personal protective equipment (PPE) must be worn when physically handling the soiled transport containers and carts, and transport personnel should properly wash their hands after completing this task. 1 Pre-Cleaning Prolonged cleaning delays can have detrimental effects on many medical devices, so it is important to keep instruments moist before they are cleaned. Devices should be sorted according to the cleaning process that will be used. Disposables should be discarded, and reusable sharps should be carefully removed from applicable instruments. Disassemble multi-part instruments to prepare them for cleaning. Open all items with box locks and hinges. Then inspect devices for gross tissue and bioburden, and rinse to remove these soils. Devices should be soaked in an enzyme or other detergent solution designed to release soil and remove it from device surfaces. Brush instrument surfaces, including ratchets, serrations and lumens to remove gross soil, and then thoroughly rinse them. Manufacturer Instructions for Use (IFU) IFU must always be followed when cleaning all devices. Manufacturers of reusable medical devices are responsible for ensuring that their devices can be effectively cleaned and disinfected or sterilized, if necessary. Device labeling should identify specific methods of cleaning that have been validated by the manufacturer. These instructions are reviewed by the US Food and Drug Administration (FDA) and are approved as part of the device 510(k) or pre-market approval process. Objective 2: Explain the importance of purified WATer in instrument cleaning processes Purified water should be used for instrument cleaning to ensure that no minerals, dissolved solids, particles, gases, or organic and non-organic chemicals are present. Purified water also reduces other problems that impact water quality, including those related to conductivity, acidity or alkalinity, and the presence or chlorides or other particles. Some water sources might also contain bacteria, algae and parasites. These contaminants could impede the processes, and might have detrimental effects on the instruments finishes. Water sample tests using chemical test strips should be made at each site where water is used as a final rinse. Common processes to purify water include: Granular activated charcoal a form of carbon riddled with small, lowvolume pores that increase the surface area and allows water to be purified by adsorption Filters Filter manufacturers should be consulted to learn when filters should be replaced. For example, a drop in pressure on the water line might indicate the need for filter replacement. Softened water requires less detergent to accomplish the same level of cleanliness. Distillation removes dissolved solids, gases and organic materials, along with particles, bacteria, pyrogens (substances in bacteria that produce fever when they are in blood) and endotoxins (poisons in bacteria that are released when the cell is destroyed). Deionization systems remove ioniccharged elements in water, along with dissolved solids and gases. However, they do not remove organics, particles, bacteria, pyrogens, or endotoxins. Reverse osmosis removes a large percentage of dissolved solids and organics, and can remove all particles, bacteria, pyrogens, and endotoxins. However, reverse osmosis removes little, if any dissolved gases. Objective 3: Identify common cleaning chemicals used for cleaning surgical instrumen- TATIon and review the basic protocols for their use Different types of chemicals are used in the cleaning process. Each has a specific purpose and must be used in accordance with the IFU for the device being cleaned. Enzymes are catalysts that can accelerate chemical reactions. Different enzymes are useful in removing specific types of organic matter. For example, protease breaks down blood, mucous and feces, and albumin and lipase helps to remove fats. Removing or dissolving fats helps to loosen bone chips, which can be bound together by fat. Amylase is useful in removing starch. Temperature is a special concern using enzyme-based cleaning products. If water temperature is too low (usually below 90ºF; 32ºC) the enzyme will not activate and will be ineffective. If water temperature is too high (above 140ºF; 60ºC), the enzyme can break down. Detergents enhance water s ability to remove soil. Emulsifiers and chelating agents in detergents help minimize formulation of insoluble deposits and prevent water spots. Alkaline detergents (ph 10-11.5) can effectively remove organic soils. An alkaline detergent may need to be neutralized with an acidic detergent rinse. Acidic detergents work well on inorganic soils and make stainless steel shine. Acidic descalers are used to remove mineral scale.

Cleaning refers to the removal of all visible and non-visible soil and any other foreign material. In contrast, decontamination relates to removing or reducing contamination by infectious organisms or other harmful substances. Objective 4: Understand the difference between cleaning and decontamination Cleaning refers to the removal of all visible and non-visible soil and any other foreign material. It is the first and most important step in the disinfection or sterilization process. One can clean without sterilizing or disinfecting, but one cannot sterilize or disinfect without cleaning. Bioburden left on medical devices can cause pyrogenic or foreign body reactions and create a breeding site for infections (even if the bioburden is microscopic). In contrast, decontamination relates to removing or reducing contamination by infectious organisms or other harmful substances. The purpose of decontamination is to make the device safe for handling without PPE. Some devices are safe for handling after thorough cleaning, while others require exposure to a microbiocidal process. Objective 5: Understand manual and mechanical cleaning, and when to use each process Manufacturer s IFU indicate whether a device should be manually or mechanically cleaned, and how specific devices should be cleaned. In general, mechanical cleaning is more effective and consistent than manual cleaning; however, many devices cannot be cleaned mechanically because the device cannot be immersed or a mechanical process may damage the device. Manual Cleaning Manual cleaning is used to physically remove deposits not removed or only softened during pre-soaking. It is also used prior to mechanical cleaning to remove heavy, gross debris and soil, and can be used when a mechanical process is not available. Some delicate or complex instruments require manual cleaning because a mechanical process may damage them or be ineffective on some or all surfaces that must be cleaned. Some instruments (example: power equipment) cannot be immersed and, therefore, must be manually cleaned. Instruments with lumens may also require manual cleaning if special mechanical attachments are not available to clean the lumens. Accessories, including cleaning brushes, are typically needed for manual cleaning. Brushes used to clean lumens must be the correct diameter. One that is too small will not effectively remove soil from lumen walls, and a brush that is too large will flatten backwards and not effectively remove the soil. The brushing action (direction) used on aluminum or stainless steel devices should be with the grain of the metal, not against or across the grain, which may damage the metal surface. Brushing should be performed under the surface of the detergent solution to prevent forming aerosols that could spread contaminants. Vertical soaking cylinders can be used for devices with lumens. The cylinder is filled with detergent solution, and the instrument is then hung in the cylinder with the lumen hanging down. This will help to soften anything still in the lumen and be drawn by gravity down and out of the lumen. Mechanical Cleaning A variety of mechanical cleaning equipment is available for cleaning medical devices. Ultrasonic Cleaners. Ultrasonic cleaners remove light soil from hard-to-reach places, such as hinges and box locks on some instruments. Heavy, gross soil must be removed from devices before placing them in an ultrasonic cleaner. Ultrasonic vibrations create tiny air bubbles that grow larger until they implode or collapse. This process, called cavitation, dislodges soil that is present, and the process is superior to manual cleaning because it can reach parts of the device that are inaccessible with manual brushing or rinsing procedures. Pre-cleaning to remove gross soil is critical before using an ultrasonic cleaner. Detergent solution ultrasonic cleaners must be changed whenever the solution appears visibly soiled, or is cloudy or turbid in appearance. The sink drain should be checked, and any debris present should be removed every time the water is changed. The cleaning solution will also need to be degassed each time the water is changed. This is done by running the ultrasonic cleaner for 5-10 minutes before placing any devices in the cleaning solution. Although ultrasonic cleaning processes are very effective, there are some devic-

es on which they should not be used. For example, ultrasonic cleaning could remove the plating on chrome, ebonized (black chrome), or other types of plated instruments. Instruments made of plastic, cork, glass, chrome, and rubber can absorb sonic waves and render the process ineffective. Needles, some delicate instruments, and endoscopes might also be damaged by ultrasonic waves. Different metals should not be processed at the same time as this can damage and discolor the metals. The cleaning chamber of an ultrasonic cleaner should not be overloaded because attempting to process too many devices at the same time may dilute the process and cause it to be ineffective. Automated Instrument Washers. A variety of automated instrument washers is available. Some perform all cleaning, disinfecting and drying processes within one chamber, while others use a tunnel configuration with separate chambers for each process. Most automated instrument washers use impingement: the spray force action of pressurized water against instruments being processed to physically remove bioburden. These washers rely on a combination of water temperature, special detergent, and spray force action to remove soil from instruments during processing. Automated instrument washers use several steps in the wash process, including: 1) pre-rinse to wet the instruments; 2) detergent cycle with higher temperature water; 3) lubrication cycle; 4) rinse cycle(s); and 5) dry cycle. Most automated instrument washers are sold with pre-set factory installed cycles. Instruments must be properly prepared before being placed in the washer. Multipart instruments must be disassembled. Generally, if an instrument can be taken apart without any tools it should be taken apart for cleaning. All box locks and hinges must be opened, and instruments should be placed in the cleaning basket with the box lock or hinge facing upward. Multi-level trays must be separated, trays should not be stacked in the washer, and all lids and covers must be removed from the tray. Special hold-down covers can be used to hold small or delicate instruments in place, and delicate instruments should be contained. Automated Cart Washers. These carts are used to wash large items, such as carts, basins and instrument containers. Their use has automated the cleaning of surgical case carts, rigid sterilization containers, basins, and other types of carts. Cart washers operate in a manner similar to automated instrument washers, but on a larger scale. High temperature water and detergent are delivered under high pressure, followed by rinse and drying cycles. CIS Self-Study Lesson Plans Technical Editor Carla McDermott, RN, CRCST Clinical Nurse III South Florida Baptist Hospital Plant City, FL Series Writer/Editor Jack D. Ninemeier, Ph.D. Michigan State University East Lansing, MI In Conclusion Reusable medical devices must be adequately cleaned and decontaminated before being prepared for packaging and subsequent sterilization. This can be a simple process for some devices, but a very complex and time-consuming process for others. Manufacturer s IFU for a particular device must always be followed exactly. Failure to do so may yield a device that is not adequately cleaned and, therefore, cannot be disinfected or sterilized. As well, the device may not be safe to handle without protection. Reference 1. International Association of Healthcare Central Service Materiel Management. Central service Technical Manual. 2007. (pp. 100 101). IAHCSMM acknowledges the assistance of the following two CS professionals who reviewed this lesson plan: Lisa Huber, BA, CRCST, ACE, FCS; Sterile Processing Manager, Anderson Hospital, Maryville, IL Paula VaNdiver, CRCST, CIS; Orthopedic Specialist, Anderson Hospital, Maryville, IL IAHCSMM is seeking volunteers to write or contribute information for our CIS Self- Study Lessons. Doing so is a great way to contribute to your own professional development, to your Association, and to your Central Service department peers. Our Team will provide guidelines and help you with the lesson to assure it will be an enjoyable process. For more information, please contact Elizabeth Berrios (elizabeth@iahcsmm.org). 32 Communiqué july / august 2014

Quiz - Decontamination Lesson No. CIS 244 (Instrument Continuing Education - ICE) Lesson expires July 2017 Sponsored by: 1. Cleaning and decontamination should begin: a. Within 24 hours of use b. At the point-of-use c. During use d. Upon arrival in the decontamination area 2. Items need to be contained during transport to: a. Prevent viewing of debris that may be disturbing to patients and visitors b. Prevent theft or unnecessary handling of the items c. Minimize contact or airborne spread of microorganisms d. Confirm they are not clean 3. If it is necessary to transport soiled items between buildings or campuses one must consult the requirements of: a. OSHA b. DOT c. TJC d. EPA 4. Until cleaning can begin it is important to: a. Sort instruments according to the cleaning process that will be used b. Remove gross soil by wiping it off the items c. Discard all disposable items d. Keep instruments moist 5. Cleaning instructions must be. a. Verified by the FDA b. Verified by the manufacturer c. Validated by the FDA d. Validated by the manufacturer 6. Purified water is used for final rinsing of instruments because water impurities can: a. Protect microorganisms b. Leave a greasy residue on device surfaces c. Impede processes d. Prevent detergents from contacting device surfaces 7. Reverse osmosis is capable of removing many impurities from water; however, it removes little, if any: a. Dissolved gases b. Dissolved solids c. Particles d. Endotoxins 8. Enzymes are useful in: a. Removing specific types of organic matter b. Removing certain stains c. Dissolving some minerals d. Dissolving bone chips 9. Emulsifiers and chelating agents in detergents help: a. Remove organic soils b. Dissolve fats c. Minimize formulation of insoluble deposits d. Make stainless steel shine 10. Bioburden left on devices after cleaning can cause: a. Allergic reactions b. Pyrogenic reactions c. Skin irritation d. Inflammation 11. The purpose of decontamination is to: a. Minimize cellular inflammation b. Render devices safe for handling without protective equipment (PPE) c. Ensure devices are functioning properly d. Expose devices to a microbiocidal process 12. Which machine is used to remove debris from hard to reach places, such as box locks and hinges? a. Cart washer b. Water pistol c. Washer-decontaminator d. Ultrasonic washer 13. After changing the solution in an ultrasonic washer, it is necessary to: a. De-gas the solution b. Energize the chamber c. Check the detergent levels d. Prime the detergent 14. Most automated instrument washers work on the principle of: a. Agitation b. Impingement c. Chemical reactions d. Thermal disinfection 15. Cart washers operate in a manner similar to: a. An ultrasonic washer b. an automated endoscope reprocessor c. A automated instrument washer d. A pasteurizing machine Request for online scoring (payment and scoring made directly online at ) Request for paper/pencil scoring (please print or type information below) m I have enclosed the scoring fee of $15. (please make checks payable to Purdue University. We regret that no refunds can Name be given) m Check here if you have a change of address Mailing Address (be sure to include apartment numbers or post office boxes) m Check here if you wish to have your results emailed to you Detach quiz, fold, and return to: Purdue University PEC Business Office Stewart Center, Room 110 128 Memorial Mall West Lafayette, IN 47907-2034 800.830.0269 City state/province Zip Code/Postal Code ( ) Daytime telephone IAHCSMM Membership Number Email Address If your name has changed in the last 12 months, please provide your former name Purdue University is an equal access/equal opportunity institution