Series VENTS VUT R WH ЕС

Similar documents
Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

NKW. Heater series HEATERS

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

KOMFORT EC DB Suspended heat recovery air handling units

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Duct electric heater with temperature controller

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

Air handling units with an integrated heat pump and rotary heat exchanger

SINGLE-ROOM VENTILATION. for schools and public spaces

USER S MANUAL. VKP Series INLINE FAN

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

VEX100 series Air handling units with cross-flow heat exchanger

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AIR HANDLING UNIT

Swegon CASA. duct coils for heating. the supply air

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

TopMaster Air Handling unit. Technical data

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

HEATING AND COOLING DEVICE AGC

HEAT RECOVERY VENTILATOR

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

VERSO Air Handling Units

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

USER'S MANUAL PS

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CAW Ceiling-mounted fan heaters for hot water

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VERSO Air Handling Units

Heat recovery unit RDKS

CENTRIFUGAL FANS user's manual. model VENTS VK.

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

TSEK VHR EC HEAT RECOVERY UNITS

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Heat Recovery Unit HERU. web-version

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Centrifugal air heaters hot water or electrical supply

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

USER S MANUAL DN-2. Drain pump

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

CASSETTE UNIT. Comfort Circle

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNITS

Air heater/cooler in combination with ground source heat pump

The ultimate in air handling units: directly and indirectly fired

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

DOMEKT. Residential ventilation units

TopMaster Air Handling Unit

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Heat Recovery Air Handling Units

Heat Recovery Units. Heat Recovery 1

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

The ultimate in air handling units: directly and indirectly fired

42AM. Air heaters PRODUCT SELECTION DATA

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

BLAST FREEZING ROOMS

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Transcription:

AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater. Recuperating efficiency up to 85%. Air handling units with heat recovery with the air capacity up to 1500 m 3 /h in sound- and heat insulated casing with integrated water heater. Recuperating efficiency up to 85%. Description The air handling units EH EC with an integrated electric heater or WH EC with an integrated water heater are the ready-to-use ventilation units that provide air filtering, supply of fresh air to the premises and exhaust of stale extract air from the premises with synchronous thermal energy transfer from extract air flow to the supply air flow through the rotary heat exchanger. The models are used in ventilation and air conditioning systems installed in various premises that require reasonable energy saving solutions and controlled ventilation systems. EC motors reduce energy demand by 1.5-3 times and ensure high performance and low noise operation. All the models are designed for connection to Ø 160, 250 and 315 mm round air ducts. Modifications EH EC models with electric heater. WH EC models with water (glycol) heater. Casing The casing consists of a frame and three-layer 20 mm ( 1500 25 mm) thick panels made of AlZn plate internally filled with mineral cotton for reliable sound- and thermal insulation. Due to the specially designed removable side panels the unit requires little space for servicing and accessing to all the unit components. Filter G4/F7 supply and G4 exhaust filters prevent dirt ingress into the the room and are the essential components that protect that unit elements against soiling. Motor The units are equipped with high-efficient direct current electronically-commutated (EC) motors with external rotor and backward curved impeller blades. Such motor design is the most progressive solution in energy saving. EC motors are featured with high performance and well controllable speed range. Premium efficiency reaching 90% is a definite advantage of electronically commutated motors. Rotary heat exchanger The rotary heat exchanger is a rotating short cylinder internally filled with corrugated aluminium band placed in such a way as to ensure passing of the supply and exhaust air streams through the heat exchanger but to exclude their direct contact. While rotating of the heat exchanger the band inside of it first comes in contact with supply air stream and then with exhaust air stream. Consequently the aluminium band is heated up and cooled down by turns and recuperates the thermal energy and Designation key: Series Energy recovery unit Rated air capacity [m 3 /h] Heater type Duct connection Motor type Control panel VENTS VUT R rotary heat exchanger 400; 700; 900; 1200; 1500 E electric heater W water heater H horizontal EC synchronous electronically commutated motor А 13 Accessories page 336 page 336 page 390 page 392 page 398 page 401 288

WWW.VENTILATION-SYSTEM.COM moisture contained in the warm extract air to cold intake air flow from outside. The advantages of the rotary heat exchanger as compared to the plate airto-air heat exchangers include higher efficiency, maintaining comfortable indoor humidity level and extremely low freezing danger (it is nearly zero for rated temperature and humidity conditions). Intake air Supply air Exhaust air Extract air Rotary heat exchanger operating logic Heater Electric heaters ( EH EC models) or water heaters ( WH EC models) are used for application of the air handling unit at low outdoor temperatures. If heat recovery is not sufficient to reach the set supply air temperature, the air heater is turned automatically on and warms up the supply air flow. The heaters are equipped with protecting devices to ensure safe and reliable operation of the unit. The water heaters are designed for max. operating pressure 1.0 MPa (10 bar) and max. heat medium operating temperature 95 C. Control and automation The unit is equipped with a built-in automation system and a multi-functional touch control panel. The standard delivery set includes a 10 m cable for connection to the control panel. EH EC automation functions: turning the unit on and off according to set parameters; week-scheduled operation; setting of the required supply air temperature and air flow with an external control panel; regulation of air control dampers; filter clogging degree; electric heating elements overheating protection (operating and emergency thermostats). WH EC automation functions: turning the unit on and off according to set parameters; week-scheduled operation; setting of the required supply air temperature and air flow with an external control panel; regulation of air control dampers; filter clogging degree; supply air temperature control by means of actuating the three-way valve; circulating pump control; water (glycol) heater freezing protection based on air temperature sensor after the heater and on return medium thermostat. Mounting The air handling unit is suitable for mounting on a level surface, to the ceiling or to wall with mounting brackets. Service access is from the side panel on the left (along supply air stream). In the unit WH EC the water heater pipes are leaded outside to the service side. The air handling unit is suitable for mounting on a level surface, to the ceiling or to wall with mounting brackets. Service access is on side of service panels of the side panel on the left (along supply air stream). In the unit WH EC the water heater pipes are leaded outside to the service side on the left from supply air side. Overall dimensions: Dimensions [mm] Type D А E F G L1 H J L 400 EH ЕС / 400 WH ЕС 159 1050 225 167 333 200 670 440 648 700 EH ЕС / 700 WH ЕС 249 1210 243 180 340 250 700 580 745 900 EH ЕС / 900 WH ЕС 249 1210 243 180 340 250 700 580 745 1200 EH ЕС / 1200 WH ЕС 314 1335 373 220 438 880 460 745 1500 EH ЕС / 1500 WH ЕС 314 1430 427 275 460 1010 560 855 VENTS 400 EH ЕС / 400 WH ЕС VENTS 700 EH ЕС / 700 WH ЕС VENTS 900 EH ЕС / 900 WH ЕС VENTS 1200 EH ЕС / 1200 WH ЕС VENTS 1500 EH ЕС / 1500 WH ЕС VENTS EH ЕС/ WH ЕС AIR HANDLING UNIT WITH HEAT RECOVERY SERIES L L L1 E E H ØD G F H ØD G F A J A J VENTS. Industrial and commercial ventilation 01-2014 289

AIR HANDLING UNITS WITH HEAT RECOVERY Technical data: 400 EH ЕС 400 WH ЕС 700 EH ЕС 700 WH ЕС 900 EH ЕС 900 WH ЕС Voltage [V / 50 Hz] 1~ 230 1~ 230 3~ 380 1~ 230 Max. fan power [W] 2 pcs. х 2 pcs. х 105 2 pcs. х 135 Electric heater power [kw] 2,0 3,3 4,5 Total unit power [W] 2290 290 3615 315 4940 440 Total unit current [А] 9,9 1,2 15,8 1,4 7,2 1,9 Maximum air capacity [m 3 /h] 400 700 900 Rotation speed [min -1 ] up to 3 up to 2600 up to 2600 Sound power level at 3 m [dba] 45 52 58 Transported air temperature [ С] -25 +60-25 +60-25 +60 Casing material alumozink alumozink alumozink Insulation 20 mm mineral wool 20 mm mineral wool 20 mm mineral wool Extract filter G4 G4 G4 Supply filter G4 (F7) G4 (F7) G4 (F7) Connected air duct diameter [mm] Ø160 Ø250 Ø250 Weight [kg] 112 128 130 efficiency [%] 85 85 85 Heat exchanger type rotary rotary rotary Heat exchanger material aluminium aluminium aluminium VENTS EH (WH) ЕС VENTS EH (WH) ЕС 400 EH (WH) EC 700 EH (WH) EC 400 EH (WH) EC 700 EH (WH) EC 290 VENTS. Industrial and commercial ventilation 01-2014

WWW.VENTILATION-SYSTEM.COM Technical data: 1200 EH ЕС 1200 WH ЕС 1500 EH ЕС 1500 WH ЕС Voltage [V / 50 Hz] 3~ 380 1~ 230 3~ 380 1~ 230 Max. fan power [W] 2 pcs. х 208 2 pcs. х 222 Electric heater power [kw] 6,0 9,0 Total unit power [W] 6570 570 9750 750 Total unit current [А] 9,5 2,5 14,1 3,2 Maximum air capacity [m 3 /h] 1200 1500 Rotation speed [min -1 ] up to 1930 up to 2000 Sound power level at 3 m [dba] 60 62 Transported air temperature [ С] -25 +60-25 +60 Casing material alumozink alumozink Insulation 20 mm mineral wool 25 mm mineral wool Extract filter G4 G4 Supply filter G4 (F7) G4 (F7) Connected air duct diameter [mm] Ø315 Ø315 Weight [kg] 165 175 efficiency [%] 85 85 Heat exchanger type rotary rotary Heat exchanger material aluminium aluminium VENTS EH (WH) ЕС VENTS EH (WH) ЕС 900 EH (WH) EC 500 400 1200 EH (WH) EC 300 200 VENTS EH ЕС/ WH ЕС 0 0 200 400 600 800 0 1200 AIR HANDLING UNIT WITH HEAT RECOVERY SERIES 900 EH (WH) EC 90 80 1200 EH (WH) EC 70 VENTS. Industrial and commercial ventilation 01-2014 291

AIR HANDLING UNITS WITH HEAT RECOVERY VENTS EH (WH) ЕС Calculation of air temperature at heat exchanger outlet: 600 500 400 1500 EH (WH) EC t = t int +k eff *(t ext - t int ) /, Where t int intake air temperature С, t ext extract air temperature С, k eff heat exchanger efficiency (as per diagram), % 300 200 0 0 200 400 600 800 0 1200 1400 1600 90 80 1500 EH (WH) EC Calculation of water heater parameters Air temperature after heater [ C] 400 / 700 / 900 WH ЕС VENTS WH ЕС Coil heating capacity [kw] External air temperature [ C] 70 Air speed inside the coil [m/s] Air flow through the coil [m 3 /h] Water pressure drop [kpa] How to use water heater diagrams Air Speed. Starting from 650 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 2.35 m/s. Water flow through the coil [l/s] Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. +5 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+26 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., +5 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (5.8 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.04 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (0.5 kpa). 292 VENTS. Industrial and commercial ventilation 01-2014

WWW.VENTILATION-SYSTEM.COM Calculation of water heater parameters temperature after heater [ C] 1200 WH ЕС VENTS WH ЕС Coil heating capacity [kw] AIR HANDLING UNIT WITH HEAT RECOVERY SERIES VENTS EH ЕС/ WH ЕС External air temperature [ C] Air speed inside the coil [m/s] Air flow through the coil [m 3 /h] Water pressure drop [kpa] How to use water heater diagrams Air Speed. Starting from 0 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 2.22 m/s. Water flow through the coil [l/s] Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. +5 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+28 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., +5 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (9.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.11 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (0.8 kpa). VENTS WH ЕС Air temperature after heater [ C] 1500 WH ЕС Coil heating capacity [kw] External air temperature [ C] Air speed inside the coil [m/s] Air flow through the coil [m 3 /h] Water pressure drop [kpa] Water flow through the coil [l/s] How to use water heater diagrams Air Speed. Starting from 1200 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 2.25 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. +5 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+27 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., +5 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (11.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.13 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (0.8 kpa). VENTS. Industrial and commercial ventilation 01-2014 293