Cerberus PRO Sales Guide

Similar documents
Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

Desigo Fire Safety intelligent detectors for complete safety

Intelligent Detection Devices

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

Innovative protection that combines power and flexibility

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

ARCHITECT AND ENGINEER SPECIFICATIONS

Cerberus FIT conventional system

Desigo TM Fire Safety System A comprehensive fire-protection system

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Cerberus PRO A comprehensive fire-protection system

ARCHITECT AND ENGINEER SPECIFICATIONS

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Installation Instructions Model ABHW-4S

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Desigo TM Fire Safety System A comprehensive fire-protection system

TrueAlarm Fire Alarm Systems

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

D7024 Fire Alarm Control Panel

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

E3 Series Broadband System

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Multi-Point Peripherals

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

E3 Series Broadband System

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

FC724 Fire control panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

FC723 Fire control panel

Cerberus PRO enjoy protecting A comprehensive fire protection system

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Conventional Releasing Control Panel

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

FC724 Fire control panel

Addressable Fire Alarm Control Panel

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

FC722 Fire control panel

TrueAlarm ES Analog Sensing

Quick Selection Guide Analog Addressable Fire Systems

Fire control panels FC726 FC726-XA

ID50series. intelligent fire alarm panels

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TrueAlarm Fire Alarm Controls

NETWORK FIRE ALARM CONTROL PANEL. Features

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Answers for infrastructure. Cerberus PRO enjoy protecting

June 10, 2002 DF C S2424

Intelligent Single Loop Fire Alarm Control Panel

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

ECC-50/100C. Emergency Command Center

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Cerberus ECO enjoy protecting. Product Brouchure.

Fire control panels FC360

OOH740, OOHC740 Automatic fire detectors

A World of Solutions

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

FC722 Fire control panel

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Multi-Point Peripherals

July 14, 1999 DF C-100.

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ADVANCED TECHNOLOGY, FLEXIBILITY, AND BUILT-IN SURVIVABILITY

SMALL SCALE SOLUTIONS

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

ID3000 intelligent. fire alarm panel

Consultant Specification AGILE Wireless Fire Detection System

ECC-50/100(E) Emergency Command Center

Installation Instructions Model DLC

IDNet and MAPNET II Addressable Devices

CATALOG NUMBER. Features. Description

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

XC10 combined fire detection and extinguishing control

Intelligent Signature Series Analog Detection

XC10 combined fire detection and extinguishing control

good things in small packages

A World of Solutions in Fire Protection Systems

Fire Alarm System Fundamentals

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

INTELLIGENT FIRE ALARM CONTROL PANEL

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

intelligent fire alarm ID60series panels

AUTOCALL FIRE DETECTION SYSTEMS.

Comprehensive solutions for greater safety and security Answers for infrastructure.

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

AND ARCHITECT SPECIFICATIONS

Laptop / PC Programming Manual

Transcription:

www.usa.siemens.com/cerberus-pro Cerberus PRO Sales Guide

Introduction Cerberus PRO answer versatile challenges with powerful fire protection Cerberus PRO is an intelligent fire protection system for fast, reliable fire detection, alarm signaling, and control. Its wide portfolio includes innovative products with intelligent technology varied control panels, fire detectors, peripheral devices, and accessories making it a comprehensive fire protection system. New business opportunities, new streams of revenue Fire safety is about protecting people and assets and securing business processes and continuity. The powerful fire protection Cerberus PRO offers makes it an excellent choice for a variety of applications, including telecommunications, data centers, small industrial facilities and commercial buildings. It provides a stand-alone control panel for smaller applications, and networkable panels for larger, more complex applications. Also, our Cerberus PRO Communication system provides occupants of mid-sized facilities with the same safety technology that s normally reserved for high end facilities fast, reliable fire detection, intelligent emergency communication capability, and complete operator control all in one cost effective package. Additionally, Cerberus PRO provides a broad range of detectors with more than 20 selectable detection profiles, allowing them to be used in clean or dirty environments. This presents new opportunities in new applications, where we can offer a tailored detection solution: Advanced Multi-Criteria detection capabilities with ASAtechnology and CO detection for demanding environments Complete range of detectors for virtually any kind of fire phenomena which allows for potential upselling Scalable solutions for larger applications A winning formula for success This guide equips you with the tools you need to effectively promote and sell this new product portfolio. With your developed customer relationships and local expertise, and our innovative and reliable technology, we can bolster your position as an industry leader in fire safety, and enjoy exponential revenue growth. [1] Next

Table Of Contents Cerberus PRO answer versatile challenges with powerful fire protection 50 Point Panel Product Overview...3 Selling Points...3 Qualifying Questions...4 Benchmark Analysis...5 Cerberus PRO Communication Product Overview...12 Selling Points...12 Qualifying Questions...13 Benchmark Analysis... 14-15 250/500 Point Panel Product Overview...6 Selling Points...6 Qualifying Questions...7 Benchmark Analysis... 8-11 Detectors Advanced Detectors with ASAtechnology Product Overview... 16-17 Advanced Detectors with ASAtechnology Features & Benefits... 18-19 Standard Detectors Product Overview...20 Standard Detectors Features & Benefits...21 Sales Collateral...22 [2] Next

FC901 50 Point Fire Control Panel Product Overview Cerberus PRO offers a cost-effective stand-alone fire control panel for smaller, simpler applications. You can connect up to 50 detectors and peripheral devices. The detectors can be connected either via one class A or two class B CNET circuits. Notification devices can be connected either via one class A or two class B Notification Appliance Circuits (NAC). An RS485 connection allows you to install remote terminals to review and operate the panel from another location in the building. Additionally, the built-in Digital Alarm Communication Transmitter (DACT) sends system information to off-site monitoring stations. The FC901 Fire Control Panel, a 50 point panel, is a cost-effective stand-alone fire control solution for smaller, simpler applications. Smaller facilities Restaurants Strip Malls Small Retail Outlet Stores Apartment Complexes Banks Cinemas Department Stores Commercial buildings Telecommunication Systems Smaller Corporate Headquarters Municipal facilities such as Court Houses or Police Stations Light Manufacturing Stand Alone Warehouse Food Stores Places of Worship Healthcare Smaller Hospitals and Clinics Nursing Homes Retirement or Assisted Living Facilities Buildings less than 75 feet in height Dormitories Small Motels Extended Stay Facilities SELLING POINTS Cost-effective, stand-alone solution for small applications Connects up to 50 devices Easy, straightforward operation Fast installation and easy servicing Compatible with the latest Siemens detector technology [3] Next

FC901 50 Point Fire Control Panel Qualifying Questions QUALIFYING QUESTIONS 1. How dispersed are the devices from the panel? The FC901 loop can be up to 3,000 feet long using 18 gauge wire. 2. What type of building is it? (Bank, Cinemas, Small Restaurant) A single FC901 can support up to 50 points, consisting of any combination of detectors and modules. 3. Do you anticipate any future expansion plans? The FC901 can meet your customers smaller facility needs with a total mix of 50 addressable devices. 4. Are you constrained by budget limitation? For smaller applications, the FC901 is a cost-effective, compact fire alarm control panel that supports high-end technology and quality at a reasonable price. 5. Do you have a need for a Voice Evacuation System? The stand-alone voice system is available as an add-on to the FC901 and offers one of the most versatile voice evacuation systems available. 6. Does your facility have a fire sprinkler/suppression system and are you looking for a panel to connect? While our FC901 system does not support releasing technologies, you may use our FC922 and FC924 to meet this specification. [4] Next

FC901 50 Point Fire Control Panel Benchmark Analysis FEATURE SIEMENS FC901 FIRELITE MS-9050UD SILENT KNIGHT 5700 FIREWARDEN-50 Addressable Signaling Line Circuits (SLCs) 1 (Style 6,7) or 2 (Style 4) 1 (Style 4,6,7) 1 (Style 4,6,7) 1 (Style 4,6,7) Intelligent Addressable Detectors Any Mix of 50 Any Mix of 50 Any Mix of 50 Any Mix of 50 Maximum Addressable Modules Any Mix of 50 Any Mix of 50 Any Mix of 50 Any Mix of 50 Maximum Addressable Devices 50 50 50 50 Built-in Notification Circuits 2 Class B or 1 Class A 2 Class B or 2 Class A 2 Class B or 1 Class A 2 Class B or 2 Class A Alarm, Trouble, and Supervisory Relays Yes Yes Yes Yes Programmable Relay Yes Yes Yes Yes Approved for Releasing No No Yes (Water Deluge) No Pre-alarm Warning Pre-Signal Plus Delay Function Pre-Signal Plus Delay Function Yes Yes Addressable 2-Wire Detector Monitor Module Yes Yes No Yes 100% Field Programmable from Built-in Keypad Yes Yes Yes Yes Auto Programming Feature Yes (Devices must be preprogrammed) Yes (Devices must be preprogrammed) Yes (Devices must be preprogrammed) Yes (Devices must be preprogrammed) Silence Inhibit Yes Yes No Yes Reset Inhibit Timer Yes Yes No Yes Remote Upload/Download No Yes Yes Yes EIA-232 Serial Printer No Yes Yes Yes Optional 80 Column Printer Option No Yes Yes Yes EIA-485, Serial Remote Annunciator Interface Yes Yes Yes Yes Main Power Supply 6.5 A 3.0 A 2.5 A 3 A One Person Walk Test Yes Yes Yes Yes Optional High Capacity DACT Communicator Standard on Board Standard on Board Standard on Board Standard on Board Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [5] Next

FC922/FC924 250/500 Point Fire Control Panels Product Overview With the networkable control panels from Cerberus PRO, you can easily accommodate larger, complex applications. Depending on the control panel, you can connect up to 504 detectors and peripheral devices. Peer-to peer networking allows up to 16 panels to be connected. This makes Cerberus PRO a flexible and scalable solution that lets you easily and quickly adapt to future changes in building structure. Additionally, the networkable panels can also be integrated into a management station from Siemens. Both the FC922 and FC924 panels are compatible with addressable field devices used on other Siemens fire systems. This translates into easy and cost-efficient migration strategies. Networkable FC922/FC924 fire control panels, with 250 and 500 points, accommodate larger, complex applications. 250-Point: small to medium & 500-Point: medium to large facilities Restaurants Strip Malls Small Retail Outlet Stores Nursing Homes Smaller Hospitals and Clinics Retirement or Assisted Living Facilities SELLING POINTS Smart product features to increase safety Safe & easy installation, commissioning and testing Easy serviceability through remote access Flexible and homogeneous system, for medium to large systems Easy, straightforward operation Fast installation and easy servicing Dependable life safety detection technology based on global experience Cerberus PRO fire control panels combine high security standards with the latest technology, making them an excellent choice for a variety of applications. The different control panels increase flexibility in system planning and keep a system scalable forthe future. Buildings less than 75 feet in height for 250-Point & less than 150 feet for 500-Point Dormitories Small Motels Extended Stay Facilities [6] Next

FC922/FC924 250/500 Point Fire Control Panels Qualifying Questions QUALIFYING QUESTIONS 1. How dispersed are the devices from the panel? The FC922 and FC924 loop can be up to 5000 feet long using 18 gauge wire. 2. What type of building is it? (College Campus, Corporate Headquarters, Nursing Home) A single networkable FC922 can connect up to 252 devices and FC924 can connect up to 504 devices with 2 NACs expandable to 4. 3. Do you anticipate any future expansion plans? The FC922/FC924 can meet your customers medium/large facility with 2 NACs expandable to 4. 4. Are you constrained by budget limitation? For medium/larger applications, the FC922/FC924 are compact, cost effective Fire Alarm Control Panels that supports high-end technology and quality at a reasonable price. 5. Do you have a need for a Voice Evacuation System? A stand-alone voice system is available as an add-on for the FC922/FC924 and offers one of the most versatile voice evacuation systems available. [7] Next

FC922 250 Point Fire Control Panels Benchmark Analysis FEATURE SIEMENS FC922 EST EST2 NOTIFIER NFS-320 FCI 7100 LCD Display 40 Characters by 8 Lines 20 Characters by 4 Lines 40 Characters by 2 Lines No Lines Recorded Programmable Control Keys 7 None None None Programmable LEDs 10 up to 96 with Options None Yes None System Point Capacity 252 380 318 197 Addressable Signaling Line Circuits (SLCs) 4 Standard 1 Standard, Expandable to 2 1 Standard 2 Standard Points Per SLC 252 over 4 Circuits 190 (96 Detectors, 94 Modules) 318 (159 Detectors, 159 Modules) 197 over 2 Circuits Weak Device Answer Detection Yes No No No Auxillary Relays (Panel) 4 3 4 0 NAC Circuits (Panel) 2 Class B / 1 Class A @ 3.0 A each 2 @ 3.5 A each; total 3.5 A 4 @ 1.5 each; total 6 A 2 @ 1.5 A each Expansion NAC Module Yes Yes Yes Yes # NACs with Expansion 4 Class B or 2 Class A 2 Class B; Class A w/adapter Module NAC Coding Temporal; March Time; CA Code Temporal; March Time Fast/Slow; Zone (Optional) 4 Class A/B 2 Class A with expansion module Temporal; March Time; CA Code Temporal; March Time; CA Code; Zone Power Supply 6.5 A 4.5 A or 6.4 A 6 A 3.335 A Expansion Power Supply 11.5 A with opt 300WPS External 6 A or 8 A No Battery Charger 100 Ah (>32 Ah in Separate Cabinet) 30 Ah 18 Ah - 200 Ah 31 Ah Local Energy Master Box Optional Optional Optional Optional Reverse Polarity Optional Optional Optional Optional Disconnect Method Thru Menu Thru Menu Card Switch Card Switch DACT (Internal/External) Optional Optional Optional Optional Common Event DACT Yes Yes (Alarm, Trouble, Supervisory) Yes (Alarm, Trouble, Security, Supervisory) Point Reporting (Serial) DACT Yes Yes Yes Yes Optional Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [8] Next

FC922 250 Point Fire Control Panels Benchmark Analysis (continued) FEATURE SIEMENS FC922 EST/ EST2 NOTIFIER NFS-320 FCI 7100 Field Programmable Laptop Panel Keypad; Laptop Panel Keypad; Laptop Panel Keypad; Laptop Remote LCD Vectoring by Event Yes Yes Yes Yes Custom Labels 40-character 40-character 12-character None One Man Walk Test Yes Yes Yes Yes Historical Log Yes Yes Yes Yes Total Number of Events 2,000 576 800 all Events 280 Events Separate Alarm/Supervisory/Trouble Logs 500 Alarm Event-only File None 200 Event Alarm Log 280 Event Log Programmable Relay Output Yes No No No Printed Reports Yes Yes Yes Yes Environmental Compensation Yes Yes Yes Yes Temperature Monitoring Yes No No No Programmable Relay Base Yes No No No Short Circuit & Ground Fault Isolator Short Circuit Only Short Circuit Only Short Circuit Only Yes Combination Photo/Heat Sensor Yes + CO as well Yes (3D or SIGA-PHS) Yes Yes Separate Outputs for Photo, Heat, & Gas Yes No No No Programmable Sounder Base Yes Yes Yes Yes Printers Yes Yes Yes Yes Remote LCD Annunciators 16 Per Panel 32 Per Panel 32 Per Panel 5 Per Panel Graphic Drivers No Yes Yes Yes Network Node Yes (Yes) EST2 Network Only Yes Yes Alarm Power Supply 6A 4A 6A 3A Fiber Optic Support Yes No Yes Yes Active Status Reminder (Alarm/Supervisory/Trouble) Yes including Gas No No No Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [9] Next

FC924 500 Point Fire Control Panels Benchmark Analysis FEATURE SIEMENS FC924 SIMPLEX 4010 NOTIFIER NFS2-640 FCI NETSOLO LCD Display 320-Character (40 Character by 8 Lines) 80-Character Programmable Control Keys 7 10 Function Menu Control Keys of which 2 are Programmable Standard 80-Character Display, 640-Character Large Display, or Display-less. 80 Character (Optional) 24 No Programmable LEDs 10 up to 130 3 96 48 System Point Capacity 504 250 636 394 SLCs (max) 8 Standard 1 Standard 1 Standard, Expandable to 2 2 Standard Points Per SLC 252 (any mix) over 4 Circuits 250 (any mix) 318 (159 Detectors, 159 Modules) 394 (198 Detectors, 196 Modules) AUX RELAYS (Panel) 4 2 4 4 Built-in Notification Circuits 1 Class A, 2 Class B @ 3.0 A 4 @ 2 A 4 @ 6A 2 Class B # NACs 4 Class B or 2 Class A 8 4 4 Class A/B A/B B A/B B Power Supply 6.5 A or 11.5 A 4A 6A 9A Battery Charger 100 Ah (> 32 Ah in Separate Cabinet) 25 Ah Panel; 50 Ah Optional Supports 18-200 Ah Batteries. (26 Ah in Separate Cabinet) Local Energy Master Box Yes Selectable Optional Yes DACT (Internal) Optional Standard Optional Standard Point Reporting (Serial) DACT Yes Yes Yes Yes Field Programming Laptop Panel Keypad; Laptop Panel Keypad; Laptop Panel Keypad; Laptop Remote LCD Vectoring by Event Yes Yes Yes No One Person Walk Test Yes Yes Yes Yes Historical Log Yes Yes Yes Yes Total Number of Events in History Log 2,000 200 800 500 Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. 31-55 Ah [10] Next

FC924 500 Point Fire Control Panels Benchmark Analysis (continued) FEATURE SIEMENS FC924 SIMPLEX 4010 NOTIFIER NFS2-640 FCI NETSOLO Separate Alarm/Supervisory/Trouble Logs 500 Alarm Event-only File 50 Alarm; 50 Supv; 100 Trouble 800+ Separate 200-event Alarm-only File 800+ Separate 200-event Alarm-only File Programmable Relay Output Yes Relay Base Not Programmable Yes Relay Base Not Programmable Printed Reports Yes Yes Yes Yes Environmental Compensation Yes Yes Yes Yes Ambient Temperature monitoring Yes Yes No No Programmable Relay Base Yes Yes No No Short Circuit & Ground Fault Isolator Short Circuit Only Yes Yes Yes Combination Photo/Heat Detector Yes + CO as well Yes Yes Yes Separate Outputs for Photo & Heat Yes Yes Yes Yes Programmable Sounder Base Yes Yes Yes Yes Printers Yes Yes Yes Yes Remote LCD Annunciators 16 Per Panel 6 Per Panel 32 Per Panel Yes Graphic Drivers No Yes Yes No Network Node Yes Public Points Only Yes Yes Alarm Power Supply 6 A 8 A 6 A 3 A Fiber Optic Support Yes Yes Yes Yes Active Status Reminder (Alm/Supv/Tbl) Yes, Also Gas Yes Yes Yes Flow/Tamper on One IAM (Quad-state) Yes, 4 I/O Module Yes Yes, Dual Input Module Yes, Dual Input Module Analog Detectors FirePrint/ASAtechnology TrueAlarm FlashScan FlashScan Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [11] Next

FV922/FV924 250/500 Point Communication Systems Product Overview The Cerberus PRO Communication system is a technologically advanced and highly addressable fire-with-voice system. Through the use of its multi-processor Network design along with its ability to utilize intelligent detection devices Cerberus PRO epitomizes a flexible and highly configurable fire protection system with integrated voice evacuation. The Cerberus PRO Communication system offers occupants of mid-sized facilities with the same safety technology that s normally reserved for high-end facilities. Cerberus PRO Communication systems are ideally suited for small and mid-sized applications, with each panel capable of providing up to 252 (Model FV922) and 504-point (Model FV924), addressable points. Additionally the built-in Digital Alarm Communication Transmitter (DACT) sends system information to off-site monitoring stations. 250-Point and 500-Point: small to mid-sized buildings K-12 schools and campuses Low mid-rise hotels and motels Retail (mall, convenience) Medical office/office parks Sporting venues/theatres/concert halls Banquet halls Churches Apartment complexes SELLING POINTS Best intelligibility for essential messages Faster, easier, costs less, and requires less space than similar mid-range voice installations Customized messages reach specific areas a the same time Fire and voice (VoIP) networking over the same copper or fiber connection for simpler installation and high quality audio distribution Meets requirements as both fire alarm system and emergency communication system (UL 864 and UL 2572) Best survivability for small voice systems Versatile, flexible, and efficient system that is scalable to today s needs and adaptable as conditions change Compatible with the latest Siemens detection technology [12] Next

FV922/FV924 250/500 Point Communication Systems Qualifying Questions QUALIFYING QUESTIONS 1. What type of building is it (Retail, banquet halls, churches)? A single networkable FV922 can connect up to 252 devices and FV924 can connect up to 504 devices, consisting of any combination of detectors or modules. 2. Do you anticipate any future expansion plans? The system s peer-to-peer networking allows up to 16 panels to be connected, so the system can easily grow as the building s needs change. 3. Are you concerned about budget limitations? The Cerberus PRO Communication system installation is faster, easier, cost effective, and requires less space than similar solutions. 4. Does your customer require differentiations between emergency messages? The system contains a built-in, 2 channel message player that supports 64 digital messages, equipping you to deliver differentiated messages for any emergency situation. [13] Next

FV922/FV924 250/500 Point Communication Systems Benchmark Analysis FEATURE SIEMENS CERBERUS PRO Communication SILENT KNIGHT 5820XL-EVS NOTIFIER NFS-640 VIGILANT VM Integration with Fire Alarm Yes Yes Yes Yes Addressable Points 504 198 636 250 Standard, 500 With Optional Second Loop Message Player Built-in Yes Yes Yes Yes Channels 2 Channel Message Player Single Channel Single or Multi-Channel Voice 3 Channels Variable Number of Amplifiers Up to 3 With or Without Backup Up to 4 Up to 4 Amplifiers 15 Power Up to 2400 W (Over 16 Nodes) Plus Unlimited Boosters Support for 4 Amplifiers for a Total of 500W Number of Speaker Circuits Per Amplifier 2 Speakers Circuits Per Amplifier Each Amplifier has 4 Speaker Circuits Expandable to Eight Up to 4 Amplifiers For a Total of 260 Watts Support for 15 Amplifiers Up to 750 Watts 1 Expandable to 2 4 Number of Speaker Zones Per System 3 Per Panel Or 48 Per System 32 Per System Not Available Not Available Number of Microphone Stations 2 Per Panel 1 Per Panel 1 Per Panel 1 Per Panel Page From One Node to Another Yes No No Yes Global Page Yes No No Yes Distributed Amplifiers Yes, 16 Nodes Plus Boosters Yes, Up to 4 No No Printer/Peripheral Connection Yes Yes Yes Yes Digital Communicator Yes Yes Yes Yes Message Priority Yes Yes Yes Yes UL Listed to Mass Notification Yes Yes Yes Yes Removable Terminal Blocks Yes No No Yes Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [14] Next

FV922/FV924 250/500 Point Communication Systems Benchmark Analysis (continued) FEATURE Message Count SIEMENS CERBERUS PRO Communication 32 Preprogrammed and 32 Custom Messages SILENT KNIGHT 5820XL-EVS NOTIFIER NFS-640 VIGILANT VM 15 Variable Count Variable Count History Log Yes, 2,500 Events Yes, 1,000 Events 800 Event Capacity in Nonvolatile Memory, Plus Separate 200-Event Alarm-Only File Message Duration 3 Minutes, Storage of 64 Digital Messages Yes, 15 Recordable 1 Minute Messages 32 Minutes at Standard Quality, 4 Minutes at High Quality 1,100 Events 39 Seconds Per Message, 2 Minutes Total Storage Communicate Over IP Yes No No Yes Auxiliary Audio In/Out Aux In and Aux Out Available Aux In Available Aux In and Aux Out Available Aux In and Aux Out Available Firefighters Telephone No Yes Yes Yes, Optional Panels and associated information are based on product documentation published on each company s public website as of 6/19/2014. [15] Next

Advanced Detectors Overview Advanced detectors are the best choice for more demanding applications with deceptive phenomena, when extremely fast response time and the highest level of prevention of false alarms is needed. With features like the innovative ASAtechnology (Advanced Signal Analysis) and a No False Alarm Guarantee, these detectors are a great choice for protecting particularly demanding areas whether sensitive or harsh. Environments like data centers or industrial production facilities need highly advanced technology with no false alarms to provide maximum safety and optimal protection. Typical application areas for advanced detectors: With the capability of earliest detection of smouldering & flaming fires by the combustion of liquid and solid matter, ASAtechnology fire detector OOH941 and ASAtechnology fire and carbon monoxide (CO) detector OOHC941 are especially suited for: Data centers and IT equipment Telecommunications facilities Hospitals and nursing homes Restaurants and small commercial kitchens Auto repair shops and parking garages Industrial production facilities Warehouses Power generation facilities ADVANCED DETECTORS SELLING POINTS Unique detection reliability and No False Alarm Guarantee provided by ASAtechnology Fast, reliable detection of smoke, heat, and carbon monoxide Earliest detection of CO-generating fumes, also independently from fire, with the CO detector Enhanced life safety provided by 20+ selectable fire detection profiles Adjustable detection profiles guarantee quick, cost-efficient adaptation to environmental conditions Forward/backward light scattering is a green solution that replaces ionization Audible Bases Combine Cerberus PRO detectors with audible sounder bases. The bases attach to the detector to provide alarm notification through the detector rather than through a separate signaling device. Siemens ABHW-4 intelligent audible bases include the ABHW-4B and ABHW-4S bases. Sounder bases offer new and innovative features including: Sleeping Area Sounder Base with 520 Hz Individual control Temporal 3 & 4 (CO) life safety and other tones One footprint Loop powered version with standard tone (3 K Hz) Low current draw [16] Next

Advanced Detectors Featuring Unique ASAtechnology Multi-criteria fire detector with forward/backward light scattering technology and additional CO sensor for enhanced detection and carbon monoxide Life Safety. 5 LEGEND 3 1 Two IR light sources 2 The rays of the two IR light sources are scattered by smoke particles in the sampling chamber and strike the light receiver. 3 IR receiver: the special position of the two IR light sources helps to distinguish between light and dark smoke particles due to forward and backward light dispersion. 4 The patented labyrinth absorbs light emitted by the light sources, thus preventing random reflection. It also captures small fibers and dust particles so that they do not enter the sampling chamber. 5 Redundant temperature sensors (two) measure the temperature. 6 The monitored CO sensor measures the CO concentration. 4 2 1 6 1 5 [17] Next

Advanced Detectors Features & Benefits Advanced Multi-criteria fire detector, OOH941: ASAtechnology Offers highest detection security with excellent early detection and rejection of deceptive phenomena. 20+ Selectable Detection Profiles Guarantees quick, cost-efficient adaptation to environmental conditions with adjustable detection profiles. Dual Optics (forward/ backward light scattering) and Dual Thermal Sensors No False Alarm Guarantee UL-listed as a high sensitivity pre-alarm NFPA 76 Compliant (Telecommunication Standard) as classified as VEWFD (Very Early Warning Fire Detector) RoHS Compliant 8 Selectable temperature settings, ranging from 135 F (57 C) to 175 F (79 C) Offers programmable options for Fixed Temperature, Rate-of-Rise, and a selectable Low Temperature warning should the temperature drop below 40 F (4 C) Features enhanced detection capability equivalent to ionization detectors that heightens their immunity to deceptive phenomena and increases their detection capability and reliability. Should one sensor fail, the detectors will still provide fail-safe operation. This also makes them a great green solution. Eliminates nuisance alarms and confirms reliable detection. Handles sophisticated applications requiring exceptional reliability. Creates new business opportunities and high sensitivity for data centers or any application that requires very early detection, where maintaining business continuity is desired. Meets the standards regarding the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment. Handles most application needs with a variety of settings. Enables the additional flexibility to address any application with the selectable low temperature setting. [18] Next

Advanced Detectors Features & Benefits Advanced Multi-criteria Fire Detector, OOHC941: Identical features to the OOH941, plus an additional CO Sensor Selectable as a Multi-criteria Addressable Detector, Smoke Detector, Heat Detector or Independent CO Detector UL 2075 Listed as a CO Life Safety Detector and meets NFPA 720 Requirements ASAtechnology Responds very quickly and reliably to fire and as Multi-criteria (smoke, heat & C0). Detects CO-generating fires as well as Carbon Monoxide detection for life safety gas detection. Cost-effectively complies with life safety standards only one detector is needed for fire and CO (instead of two) Cost-effectively complies with life safety standards only one detector is needed for fire and CO (instead of two) Sophisticated applications require exceptional technology. These detectors feature our unique and dynamic ASAtechnology, which makes them highly reliable in preventing false alarms caused by deceptive on-site phenomena, such as machine exhaust gases, dust, or steam 20+ Selectable detection application profiles Provides field programmable, customizable supervisory signals for temperature or CO levels Dual optics (forward/ backward light scattering) and dual thermal sensors 8 selectable temperature settings, ranging from 135 F (57 C) to 175 F (79 C) Offers programmable options for fixed temperature, rate-of-rise, and a selectable Low Temperature warning should the temperature drop below 40 F (4 C) No False Alarm Guarantee UL-listed and FM approved as a high sensitivity pre-alarm NFPA 76 Compliant (Telecommunication Standard) as classified as VEWFD (Very Early Warning Fire Detector) RoHS Compliant Enhanced detection to both smouldering and flaming fires equivalent to ionization detectors. Heightens their immunity to deceptive phenomena and increases their detection capability and reliability. Should one sensor fail, the detectors will still provide fail-safe operation. This also makes them a great green solution. Meets most application needs for heat detection. with a variety of field configurable temperature alarm settings. Provides additional flexibility to address any application with the selectable low temperature setting. Eliminates nuisance alarms and confirms reliable detection. Handles sophisticated applications that require Very Early Fire Detection. Creates new business opportunities. Meets the standards regarding the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment. [19] Next

Standard Detectors Overview Standard detectors are an economical, reliable solution for standard application. Detectors from both lines can be used together in a single network, allowing you to manage diverse detection requirements with one detector family and one system. Typical application areas for standard detectors: Backed by many years of field experience and proven under numerous operating conditions, the standard fire detectors provide comprehensive safety. They offer very high performance on the basis of their advanced detection algorithms, making them a great choice in standard environmental conditions where only occasional deceptive phenomena occur, in environments such as: Retail stores Restaurants Offices Hotel rooms STANDARD DETECTORS SELLING POINTS State-of-the-art detection algorithms Designed with capabilities to use existing wiring Field-selectable application profiles Cost-effective range of detectors for standard applications Rejects deceptive phenomena that may cause false alarms Tri-color detector status LED with 360 viewing Wide operating temperature range suitable for use in the most demanding applications Ability to provide early detection of smoke and products of combustion present in air moving through an HVAC duct [20] Next

Standard Detectors Features & Benefits Standard Multi-criteria Fire Detector OH921: Multi-criteria addressable detector that incorporates photoelectric and thermal sensors Modern, accurate and shock resistant thermistor Field-selectable application profiles Existing wiring may be used Provides enhanced detection to a wide range of products of combustion, while offering superior rejection to nuisance-alarm sources. Senses temperature changes. Detects fires reliably and efficiently. Minimizes costs on material and installation in retrofit cases. Utilizes SureWire technology Helps eliminate installation errors and reduce installation time by up to 25%. Self Testing Tri-color detector status LED with 360 viewing Performs complete diagnostics every 10 seconds and self-monitors for sensitivity within UL Listed limits. Capable of notifying normal supervisory, trouble, and alarm conditions. Standard Optical (photoelectric) Smoke Detector OP921: Photoelectric, light-scattering, addressable detector Ensures enhanced sensitivity to actual fires and practically eliminates false alarms. Uitilizes advanced software algorithms Analyzes signals to provide highly stable and accurate smoke detection. Operating temperature range of 32 F (0 C) to 120 F (49 C) Wide operating temperature range suitable for use in the most demanding applications. UL listed for direct in-duct plenum usage (without duct housing) Ability to provide early detection of smoke and products of combustion present in air moving through an HVAC duct. Tri-color detector status LED with 360 viewing Notifies for normal supervisory, trouble, and alarm conditions. Utilizes SureWire technology Helps eliminate installation errors and reduce installation time by up to 25%. Self Testing Performs complete diagnostics every 10 seconds and self-monitors for sensitivity within UL Listed limits. Standard Thermal (Heat) Detector HI921: Provides 7 field-selectable settings in the 135 174 F temperature range Tri-color detector status LED with 360 viewing Compatible with Model DPU Provides a low-temperature warning at 40 F Provides a flexible field solution for multiple temperature settings with one heat detector. Notifies for normal, supervisory, trouble, and alarm conditions. Uses the standardized Siemens DPU (device programmer / loop tester) for easy programming and testing in the field. Detector can be specifically set to monitor for freezing pipes for sprinkler system supervsion as per NFPA 72 requirements. Utilizes SureWire technology Helps eliminate installation errors and reduce installation time by up to 25%. Field programmable as rate-of-rise or fixed temperature Flexible field adjustable settings meeting specifications and customer requirements. [21] Next

Sales Collateral Cerberus PRO detectors and peripherals perfectly connected Siemens Industry, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel (973) 593-2600 Fax (973) 593-6670 FC901 FC922/FC924 FV922/FV924 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. All rights reserved. Printed in USA 153-FIS-114 2014 Siemens Industry, Inc. CerberusTM PRO Advanced detectors with ASAtechnologyTM Advanced multi-criteria fire detector utilizing optical, thermal, and optional CO sensor Extreme immunity to deceptive phenomena while providing enhanced detection with the industry s only No False Alarm Guarantee Provide redundant optical and thermal sensors for extraordinary reliability Comply with NFPA 76 (Telecommunication Standard) as a Very Early Warning Fire Detector (VEWFD) as a result of high-sensitivity alarm capabilities www.usa.siemens.com/cerberus-pro CerberusTM PRO standard detectors Include a multi-purpose carbon monoxide (CO) life safety and fire detector Selectable as a multi-criteria fire detector and/or a CO life safety gas detector Environmentally friendly green detectors, as they are RoHScompliant and replace the need for ionization detectors due to forward/backward light scattering technology Provide multiple selectable temperature alarm thresholds, fixed and rate-of-rise Multi-criteria fire detector OOH941 Multi-criteria fire/co detector OOHC941 S54320-F7-A2 S54320-F8-A2 Solution for standard applications with average risk and moderate potential for deceptive phenomena Prevents false alarms thanks to intelligent algorithms Thermal detector provides 7 selectable alarm thresholds, fixed and rate-of-rise. Offer wide operating temperature & relative humidity (RH) range Green detectors, as they are RoHS-compliant, meeting the standards regarding the restriction of the use of certain hazardous substances in electrical and electronic equipment Multi-criteria fire detector OH921 Thermal (heat) detector HI921 Optical (photoelectric) smoke detector OP921 S54320-F6-A2 S54320-F5-A2 S54320-F4-A2 Compatible with bases below EXCEPT ADBH-11 Cerberus PRO Answers for infrastructure and cities. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority and not only where energy is concerned. In addition, we need to increase comfort for the wellbeing of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure. Planning Tool Compatible with bases below EXCEPT ADBH-11 Compatible with bases below EXCEPT ADBH-11 Answers for infrastructure. www.usa.siemens.com/fire ASAtechnology most intelligent and reliable fire detection Detector base DB-11 Detector base DB-11E Detector relay base DB2-HR Audible base SBGA-34 Audible base ADBH-11 Audible base ABHW-4B Audible base ABHW-4S, (520Hz) Ceiling mount remote lamp RL-HC Wall mount remote lamp RL-HW 500-094151 500-094151E S54370-F12-A1 S54370-F13-A1 500-033210 S54320-F13-A1 S54320-F14-A1 500-033230 500-033310 FC901 stand-alone control panel Housings FC901 2 With advanced signal analysis and 20+ selectable profiles, ASAtechnology detectors provide very fast, highly reliable detection in demanding environments. Cerberus PRO intelligent protection Remote indicators Air duct housings H-series detectors Are connected to automatic fire detectors that are not easily accessible or visible Contain an indicator lamp unit with one or two LEDs which will light up when the connected detector triggers an alarm Backward compatible with H-series detector Same footprint as existing Siemens duct housings Include optional remote test feature and indicator New, improved features include easy installation, improved operating temperature range, and optional in-duct carbon monoxide (CO) detection Existing detectors from other fire protection systems from Siemens, such as the H-series, can also be placed on the FDnet together with Cerberus PRO devices TM Detectors with the innovative ASAtechnology provide intelligent detection of smoke, heat, and CO in any environment without false alarms. A comprehensive fire protection system An innovation that sets new standards Protecting people and assets and securing business processes are of utmost importance. That s why Cerberus PRO provides an excellent fire safety solution for any application area. Features like the innovative ASAtechnology (Advanced Signal Analysis) and No False Alarm Guarantee make these detectors a great choice for protecting particularly demanding areas whether sensitive or harsh. Environments like data centers or industrial production facilities need highly advanced technology with no false alarms to provide maximum safety and optimal protection. Answers for infrastructure. Cerberus Pro System Brochure 153-FIS-112 Indicator ceiling mount ILED-HC Typical application areas With the capability of earliest detection of flaming fires caused by the combustion of liquid and solid matter, ASAtechnology fire detector OOH941 and ASAtechnology fire and carbon monoxide (CO) detector OOHC7941 are especially suited for: Data centers and IT equipment Telecommunications facilities Hospitals and nursing homes Restaurants and small commercial kitchens Auto repair shops and parking garages Industrial production facilities Warehouses Power generation facilities 500-048809 Air duct housing FDBZ492 Air duct housing with relays FDBZ492-HR Optional water-tight enclosure NEMA 4X FDBZ-WT S54319-B22-A1 S54319-B23-A1 S54319-B26-A1 Expansion options FC901 Housing FH901-R3 Red S54433-B103-A4 Ceiling mount remote lamp RL-HC Wall mount remote lamp RL-HW 500-033380 500-033230 500-033310 FITS ALL BASES Remote indicator wall mount ILED-HW Remote test lamp FDBZ492-RTL Weather-proof enclosure NEMA 3R WP-2000 Audible base ADBH-11 Audible base SBGA-34 Audible base ABHW-4B Audible base ABHW-4S, (520Hz) Detector base DB-11 Detector base DB-11E Detector relay base DB2-HR 500-048637 S54319-S27-A1 500-649714 500-033210 S54370-F13-A1 S54320-F13-A1 S54320-F14-A1 500-094151 500-094151E S54370-F12-A1 Power supply (170 W) FP2011-U1 Incl. connection cable 500-450222 Battery bracket FHA901-U1 Secures batteries to meet seismic requirements S54433-B107-A1 Kits FC901 4 Remote peripheral module FCA2018-U1 Interface to remote printers S54400-A65-A1 PAL-1 UL listed parallel printer 500-692407 FC901 Electronic kit FC901-U3 contains main board and operator unit FCM901-U3 and power supply (170 W) S54433-C105-A1 FC901 stand-alone control panel Fire system display FSD901-R3 Fire control panel FC901-R3 Remote peripheral module FCA2018-U1 2 Manual pull stations and accessories Line modules Are for immediate manual actuation of a fire alarm or an extinguishing process Direct alarm actuation by pulling down locking lever For indoor and outdoor applications For surface- and recess-mounted feed lines in easily accessible places Intelligently connect independent, potential-free make-or-break contacts Can be independently configured via a fire control panel for status or alarm messages Input modules monitor devices responsible for alarm inputs and confirm signals or technical states etc. Output modules control other equipment, such as door holders, fire dampers, smoke control systems, plant shutdown etc. FDCIO422 provides class A wiring and supervision RS485 NACs Devices Cerberus PRO Advanced line 1 Main board and operator unit FCM901-U3 Single action manual pull station HMS-S Dual action manual pull station HMS-D Single action metal manual pull station HMS-M Mini single input interface module HTRI-M Single input interface module with relay HTRI-R Dual input interface module HTRI-D Single input interface module HTRI-S Control point HCP Conventional zone module HZM Line isolator HLIM Input/output module FDCIO422 500-033200 500-033400 500-033450 500-034000 500-033300 500-033360 500-033370 500-034860 500-034850 500-033170 4 inputs, 4 outputs Class A and B wiring S54322-F4-A1 ASAtechnology Flyer 153-FIS-113 Power supply FC901 Fire System Display FSD901-R3 S54433-C102-A2 Trim kit FHA902-R1 Red S54433-B106-A2 3 1 WORKS WITH ALL DETECTORS 4 Answers for infrastructure. Fire System Display FSD901-U3 S54433-C102-A1 5 Thermal detector HFPT-11 500-033290 Main board and operator unit FCM901-U3 Interface options for loops, NACs, relays, aux. power, communication bus, city tie/ leased line module System LCD display, LEDs, control buttons Built in on-board DACT S54433-B101-A1 Leased Line/city tie cable FCA901-U1 Required for use with FCI2020-U1 with FC901 S54433-C106-A1 Trim kit FHA902-U1 Black S54433-B106-A1 Photo/Thermal detector HFP-11 System operating units FC901 Leased line/city tie module FCI2020-U1 Same as FC922/FV924 requires separate Leased Line/City Tie Cable S54400-A57-A1 Housing FH901-U3 Black S54433-B103-A3 2 Housing With back box, door, window FH901-U3 black FH901-R3 red 3 Power supply FP2011-U1 170 W, 24 VDC 4 Battery bracket FHA901-U1 5 City tie PAL-1 Cerberus PRO Standard line FCI2020-U1 FCA901-U1 (cable) H-Series Air Duct Housing I/O Module Manual Pull Station Cerberus Pro Planning Tool Poster 153-FIS-114 www.usa.siemens.com/cerberus-pro FC901 fire control panel a costeffective solution for small applications www.usa.siemens.com/cpivc An efficient stand-alone option for small fire protection systems The FC901 stand-alone control panel from CerberusTM PRO is an excellent choice for small application areas. Cost-effective solution for small systems The FC901 fire control panel is an excellent choice when a basic, stand-alone panel is needed to cost-effectively install small and simple fire protection systems. Up to 50 detectors and peripheral devices from the Cerberus PRO family and other existing Siemens fire protection systems can be connected to the FC901. Additionally, you will be able to connect future Siemens detectors and peripherals to it. This makes FC901 a safe and long-term investment. Cerberus PRO Intelligent Voice Communication Typical application areas The basic FC901 fire control panel is specifically suited to install small fire protection systems in small facilities that have sprinklers, such as: Retail shops Doctor s offices Dry cleaners Small restaurants Strip malls Banks Small commercial buildings Premium intelligent protection system with emergency voice communication, together in one cost-effective package Answers for infrastructure and cities. Answers for infrastructure. FC901 50 Point Fire Control Panel Flyer 153-FIS-115 Cerberus PRO Communication Brochure 153-FIS-132 > Find the tools you need on Fire Partners or Collateral Corner. Intro > 50 Point Panel > [22] Next 250/500 Point Panel >

Siemens Industry, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel (973) 593-2600 Fax (973) 593-6670 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. All rights reserved. Printed in USA 2014 Siemens Industry, Inc.