LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Similar documents
LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-3 LOW ENERGY GAMMA SCINTILLATOR. May 2018 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

MODEL RWM RADIATION WASTE MONITOR LUDLUM MODEL RWM RADIATION WASTE MONITOR INSTALLATION MANUAL

LUDLUM MODEL 19A. Micro R Meter. May 2017 Serial No and Succeeding Serial Numbers

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

Identify the following features and specifications for the ESP1

LUDLUM MODEL RK2 RESPONSE KIT. October 2017 Serial Number and Succeeding Serial Numbers

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

LUDLUM MODEL RK RESPONSE KIT. January 2016 Serial Number and Succeeding Serial Numbers

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

RAM GENE / RAM GENE-1

LUDLUM MODEL ALARM RATEMETER. June 2017 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL ALPHA/BETA RATEMETER. April 2018 Serial No and Succeeding Serial Numbers

Nuclear Associates

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

Portable Survey Instruments NISP-RP-01

LUDLUM MODEL 14C-RK RESPONSE KIT. April 2015 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL

Ranger EXP RADIATION A L E R T

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Department of State Health Services

LUDLUM MODEL 2360 SCALER/RATEMETER DATA LOGGER. July 2016 Serial Number and Succeeding Serial Numbers

Radiation Alert Frisker INTERNATIONAL

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Model OEM-2 INSTRUCTIONS FOR USE

OPERATIONS MAINTENANCE MANUAL

CD6102 / CD6102 OC / CD6102-2

Victoreen. Operator Manual. Current Mode Beta Scintillation Detector, Model

MaxLite LED MICRO-T PANEL

A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

PM-200 Power Module Operating Instructions

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Dosimeters/Survey meters

DIGITAL AREA RADIATION MONITOR

LUDLUM MODEL 52 PORTABLE PORTAL MONITOR. November 2011 Serial No and Succeeding Serial Numbers

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

MGC Dock User s Manual

Advanced Test Equipment Rentals ATEC (2832) Installation Note

OPERATION AND INSTALLATION MANUAL

CO2 Sensor User and Installation Guide

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

LUDLUM MODEL 334AB ALPHA/BETA PARTICULATE MONITOR. December 2016

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Mini rad-d User's Manual - February 22, 2010

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

Series: MBC1-TC Mini Benchtop Temperature Controller

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

RK/ RK Oxygen Detector Operator s Manual

Ludlum Measurements, Inc. Domestic Price List August 8, 2017

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Area Monitor/Frisker Count Rate Meter Victoreen

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

G-M Hotdog Detectors: Everything You've Wanted to Know (But Were Afraid to Ask)

CT2 Retro Box Installation Instruction Manual

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

PRM470 Portable Monitor Operation and Service Manual D00092 June 02, 2016 Rev. 2

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

XC Portable Air Conditioning

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

SeedVac TM REF 90091

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

MGC Dock User s Manual


GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Carbon Monoxide Monitor and Retrofit Carbon Monoxide Monitor Kit W-2808/37027

Document No

Kata products Kata DGM-1500 Turva

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Eliza Hugger 56 CEILING FAN

Global Water Instrumentation, Inc.

SYSTEM CONTROL KIT Model: CK-41P

Model NT20e Installation Guide

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

Transcription:

LUDLUM MODEL 44-25 ALPHA, BETA, GAMMA HAND DETECTOR June 2016 Serial Number 155835 and Succeeding Serial Numbers

LUDLUM MODEL 44-25 ALPHA, BETA, GAMMA HAND DETECTOR June 2016 Serial Number 155835 and Succeeding Serial Numbers LUDLUM MEASUREMENTS, INC. 501 OAK STREET, P.O. BOX 810 SWEETWATER, TEXAS 79556 325-235-5494, FAX: 325-235-4672

STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered in this manual to be free of defects due to workmanship, material, and design for a period of twelve months from the date of delivery. The calibration of a product is warranted to be within its specified accuracy limits at the time of shipment. In the event of instrument failure, notify Ludlum Measurements to determine if repair, recalibration, or replacement is required. This warranty excludes the replacement of photomultiplier tubes, G-M and proportional tubes, and scintillation crystals which are broken due to excessive physical abuse or used for purposes other than intended. There are no warranties, express or implied, including without limitation any implied warranty of merchantability or fitness, which extend beyond the description of the face there of. If the product does not perform as warranted herein, purchaser s sole remedy shall be repair or replacement, at the option of Ludlum Measurements. In no event will Ludlum Measurements be liable for damages, lost revenue, lost wages, or any other incidental or consequential damages, arising from the purchase, use, or inability to use product. RETURN OF GOODS TO MANUFACTURER If equipment needs to be returned to Ludlum Measurements, Inc. for repair or calibration, please send to the address below. All shipments should include documentation containing return shipping address, customer name, telephone number, description of service requested, and all other necessary information. Your cooperation will expedite the return of your equipment. LUDLUM MEASUREMENTS, INC. ATTN: REPAIR DEPARTMENT 501 OAK STREET SWEETWATER, TX 79556 800-622-0828 325-235-5494 FAX 325-235-4672

Table of Contents Introduction 1 Unpacking and Repacking 3 Specifications 4 Operating Procedures 5 Parts List 6 Drawings and Diagrams 44-25 Hand Monitor, Drawing 224 9 7 Ludlum Measurements, Inc. June 2016

Introduction The Ludlum Model 44-25 GM (Geiger-Mueller) Hand Monitor detects alpha, beta, and gamma radiation. Its size and shape provide easy handling for surveying or personnel monitoring. The detector is energy dependant, over-responding by a factor of 6 in the 60-100 kev range when normalized to 137 Cs. This detector operates between 850-1000 volts, with a recommendation from the tube manufacturer of approximately 900 Vdc. Recommended instrument input sensitivity is approximately 80 mv or higher to prevent the detector from double pulsing (where the detector counts a single pulse from the instrument multiple times.) Caution! The GM tube face can rupture above 2438 m (8000 ft) in altitude. When transporting this detector by air, use an airtight container in order to avoid sudden atmospheric changes resulting in tube failure. The Ludlum Model 44-25 will operate with any Ludlum instruments or equivalent instruments that provide 900 Vdc and an input sensitivity of approximately 80 mv or higher. Ludlum Measurements, Inc. Page 1 June 2016

Model 44-25 Ludlum Measurements, Inc. Page 2 June 2016

Unpacking and Repacking Remove the calibration certificate or detector functional check certificate and place it in a secure location. Remove the detector(s) and accessories (if applicable) and ensure that all items listed on the packing list are in the carton. If multiple detectors are included, refer to the calibration certificates for serial number (SN) matches. The Model 44-25 serial number is located on the side of the detector. To return an instrument or detector for repair or calibration, provide sufficient packing material to prevent damage during shipment and affix appropriate warning labels to promote careful handling. Every returned instrument must be accompanied by an Instrument Return Form, which can be downloaded from the Ludlum website at www.ludlums.com. Find the form by clicking the Support tab and selecting Repair and Calibration from the drop-down menu. Then choose the appropriate Repair and Calibration division where you will find a link to the form. Caution! When shipping a Model 44-25 by air, it is necessary to ship the tube in a sealed container to avoid sudden atmospheric changes, which could rupture the tube. Ludlum Measurements, Inc. Page 3 June 2016

Specifications Detector: 2 each pancake-type halogen quenched GM Window: 1.7 ± 0.3 mg/cm 2 mica Window Area: active is 31 cm 2 ; open is 18 cm 2 Efficiency (4π geometry): typically 5% for 14 C; 22% for 90 Sr/ 90 Y; 19% for 99 Tc; 32% for 32 P; 15% for 239 Pu Sensitivity: typically 6600 cpm/mr/hr ( 137 Cs gamma) Energy Response: energy dependant Dead Time: typically 80 µs Operating Voltage: 900 volts Compatible Instruments: general-purpose survey meters, ratemeters and scalers. Connector: series C (others available) Construction: aluminum housing with beige powder-coat finish; stainless steel protective screen Temperature Range: -15 to 50 C (5 to 122 F); may be certified for (-40 to 65 C) -40 to 150 F Size: 24.1 x 15.2 x 19.8 cm (9.5 x 6 x 7.8 in.) (H x W x L) Weight: 1.5 kg (3.3 lb) Ludlum Measurements, Inc. Page 4 June 2016

Operating Procedures CONNECTING TO AN INSTRUMENT Connect one end of the cable provided to the detector by firmly pushing the connector together while twisting clockwise ¼ turn until latched. Repeat the process in the same manner with the other end of the cable and the instrument. TESTING THE DETECTOR 1. Insure that the instrument high voltage (HV) is at the proper setting for the detector (900 volts). 2. Connect the detector to the instrument and check for a proper background reading (typically 25-50 cpm at 8-15 µr/hr). 3. Expose the detector to a check source and verify that the instrument indicates within 20% of the check source reading from the last calibration. Alternatively, expose the detector to a source of known value and verify that the detector detects greater than or equal to the efficiency listed in the specification section of this manual. 4. Instruments and detectors that meet these criteria are ready for use. Failure to meet these criteria may indicate a malfunction in the detector. Ludlum Measurements, Inc. Page 5 June 2016

Parts List Model 44-25 Alpha-Beta-Gamma Hand Monitor UNIT Completely Assembled Model 44-25 Alpha-Beta-Gamma Hand Monitor 47-1508 Quantity Description Part # 2EA G-M TUBE (LND 7311) 01-5008 2EA TUBE HOLDER 7073-037-02 1EA LEFT MOUNTING BRACKET 7224-003-01 1EA RIGHT MOUNTING BRACKET 7224-003-02 1EA COVER 7224-004-01 1EA BACK PANEL 7224-005-01 2EA PENCIL CLIP 01-5237 2EA RESISTOR, 3.3 MEG ¼W 5% 10-7044 1EA CONNECTOR, UG 706/U 13-7751 10IN. HV WIRE 21-9312 Ludlum Measurements, Inc. Page 6 June 2016

Drawings and Diagrams Ludlum Measurements, Inc. Page 7 June 2016