CASS9000 Standalone FingerPrint Door Access System. User Manual

Similar documents
UNC100 Integra Manual

NDC-F16. Access Control Panel. Installation Manual

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Section PERIMETER SECURITY SYSTEMS

HRX Technical Manual. Version 1.2

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

HRX3000. Technical Manual

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Protégé Eclipse LED Keypad User Manual PRT-KLES

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

LCF Touch Modbus Datasheet Application Security Advice Caution

PTE0705 Electric Fence Monitor

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

Beacon 800 Gas Monitor Operator s Manual

IDS816 User Manual H Issued January 2009

642 LCD Keypad. User Manual

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Contents. Glossary

MOBILE CALL GSM Alarm System User s Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

installation & operation manual

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

System. For a better understanding of this product, please read this user manual thoroughly before using it.

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Auto Dialer. Manual E-921APQ E-921GPQ

GLD-30 Gas Leak Detector

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Four-Door Access Controller User s Manual

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Please read the following before using Kaba E-Flash products

Product Data Sheet. Remote Terminals. Features:

INSTRUCTION MANUAL P Heating and 1 Cooling

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

INSTALLATION INSTRUCTIONS

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Networked Access Control Panel. Installation Guide

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

User Manual. Humidity-Temperature Chart Recorder. Model RH520

DYGIZONE GJD910 Lighting Controller & Enunciator

EXPERT TRI-STAR. Temperature controller. User s Manual

AirGard 385 Fume Hood Monitor

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual

636 and 646 Keypads. User s Manual

ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Carbon Monoxide Transmitter

Watchguard WGAP864 User Manual

Planning Elevator Relay Groups Programming Millenium for Windows Software

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

WARNING Important Safety Information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

LCF Touch (from firmware version 1.7)

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

LCD and 16-Zone LED Keypads. User s Manual

RC-2000 Thermostat Installation Instructions

! "! # Please read these installation and operating instructions completely and carefully before starting.

QUICK CONSUMER REFERENCE GUIDE

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

THX-DL Data Logger USER & INSTALLATION MANUAL V

Instruction Manual Model Backup Switch, 1 for 8

User Manual. Dryer Controller M720

Smart Thermostat. Set-Up Guide

IntelliDoX Operator Manual

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

Omniguard 4: Features

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

NO ONE DARES COME CLOSE O WNER S GUIDE 7756V

REPEATER FS5200R INSTRUCTION MANUAL

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

2GIG GC3 Security & Automation System. Fingertip Guide

Dolphin 9900 Mobile Computer

Dryer Controller M720

InBio X60 Series Access Control Panel User Manual

Two-Channel Gas Controller

Ethernet General Purpose

Transcription:

CASS9000 Standalone FingerPrint Door Access System User Manual CASS9000

COPYRIGHT Information furnished by Cass Technology Sdn. Bhd. is believed to be accurate and reliable. Cass Technology Sdn. Bhd. have patents, patent application, trademarks, copyrights, or other intellectual property rights covering subject matter in this manual. No part of this publication may be reproduced, transcribed, transmitted, stored in retrieval systems or translated into any languages in any form or by any means without the written authorization from Cass Technology Sdn. Bhd., Cass Technology Sdn. Bhd. reserves the right to change/modify any information in this manual at any time without any prior notice. Copyright 2005 by Cass Technology Sdn. Bhd. No. 28 Jalan PJU 3/48, PJU 3 Sunway Damansara Technology Park, 47810 Petaling Jaya, Selangor Darul Ehsan, Malaysia. Tel: +603 78030011 Fax: +603 78030066 Email: support@castle.com.my All rights reserved. December 2005 Printed in Malaysia This document supports firmware version HW.C9K.R2.1 FW.C9KSTD.R1.051129 TRADEMARKS: CASTLE is a registered of CASS TECHNOLOGY SDN BHD

WARRANTY SUMMARY (CASS9000 Door Access System) Cass Technology Sdn. Bhd. warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of twelve (12) months. If a product proves defective within the respective period, please contact your nearest Cass Technology Sdn. Bhd. authorized dealer to arrange for warranty service. EXCEPT AS PROVIDED IN THIS SUMMARY OR THE APPLICABLE WARRANTY STATEMENT, CASS TECHNOLOGY SDN. BHD. MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL CASS TECHNOLOGY SDN. BHD. BE LIABLE FOR INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES.

GENERAL SAFETY SUMMARY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. TO AVOID FIRE OR PERSONAL INJURY Use Proper Power Supply Unit. Use only the power supply unit specified for this product. Do Not Operate Without Covers. removed. Do not operate this product with covers or panels Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do Not Operate below or above specified temperature and humidity condition. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. 04 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

TABLE OF CONTENTS COPYRIGHT......................... 02 WARRANTY SUMMARY.................. 03 GENERAL SAFETY SUMMARY.............. 04 GENERAL FEATURES................... 06 SYSTEM MENU STRUCTURE............... 07 CASS9000 OPERATION GUIDE............. 08 Menu 1 (Reader Lock)..................... 08 Menu 2 (User Menu )....................... 08 Menu 3 (Programming)..................... 09 13 Menu 4 (Alarm).......................... 14 Operation procedure...................... 15 How to use finger only to access? How to use PIN to access to access? How to activate the alarm? How to change to 'Card only' mode? CASS9000 FINGERPRINT WIRING DIAGRAM... 16 SENSOR MAINTENANCE................. 17 CASS9000 TECHNICAL SPECIFICATION...... 18 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 05

GENERAL FEATURES 800 Fingerprint Templates 800 Card Users 6 Operation Mode Finger only mode (1:30 1 st 30 Templates Matching Sequence) Finger ID and Fingerprint Card and Fingerprint Card and Pin Card Only Global Pin Only (2 sets of 4 digits Pin Access) Door Setting Lock Release Time (1-15 Sec) Door Open Time (1-30 Sec) Security ON / OFF Alarm ON / OFF 1:30 Fingerprint Template Matching Sequence User definable 5 digit user ID (ID range from 00001 to 59999) User definable Adjustable Security Level 1 Alarm Input and 1 Alarm Output Reader Locking Feature External Watch Dog Real time clock display during system screen saver mode Animated icon display 16 keypad for user programming 3 LEDs Master login password 06 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

CASS9000 System Menu Structure [1]Reader Lock (Page 08) * Master login(master Finger) is require to enter into this menu. Please refer to page 13 under 'Enroll Master' how to enroll master finger. F1 (Main Menu) [2]User Menu [1]Enroll User (Page 08) [2]Delete User (Page 08) * Master Password is require to enter into this menu. Please refer to page 10 under 'Master Password', how to enroll change master password [3]Programming [1]System Param [1]Date & Time (Page 09) [2]Door Param (Page 09) [3]Master Reset (Page 10) [4]Password (Page 10) [5]Access Mode (Page 12) [2]Security Level (Page 13) [3]Calibrate (Page 13) [4] Enroll Master (Page 13) [4]Alarm (Page 14) CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 07

CASS9000 OPERATION GUIDE MENU 1 - READER LOCK MODE [Reader Lock] To lock the reader operation temporarily. No access activity until reader unlock. (default password 3333) b) Select [1] Reader Lock c) Key in 4 digits reader lock pin d) Reader is now lock and prevent from any access operation. * To unlock the reader, repeat the same procedure * To change Reader lock number, please refer to page 10 MENU 2 USER MENU * Master ID is required to enter in this menu. Please refer to page 13, how to enroll master finger. (A) ENROLL MENU a) ress [F1] to enter the System Menu c) Select [2] User Menu to enter the User Menu d) Scan Master Login finger e) Select [1] Enroll User to register new user f) Select [1] New Auto ID to let the system create it OR select [2] Specify ID if you wish to use your own ID g) Select [1] Add Proxy Card to register user proxy card h) Select [1] Flash Card to register card OR select [2] Key In Card to manual register card i) Select [1] Add Pin to register 4 digit user PIN OR select [2] No Pin if no PIN need to register. j) Select [1] Scan finger to register fingerprint template, Scan finger, repeat it 5 times until system confirm it OR select [2] No finger to add card data only (B) DELETE USER c) Select [2] User Menu to enter the User Menu d) Scan Master Login finger e) Select [2] Delete User to register new user f) Enter [1] Enter Card No OR [2] Enter ID that going to erase * Caution: User ID will be erased instantly once User ID have been enter & the process NOT REVERSIBLE! 08 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

MENU 3 PROGRAMMING (A) SYSTEM PARAM 1. Date & Time To set date and time display on the reader e) Select [1] System Param f) Select [1] Date & Time to set and change Time and Date g) Key in current year [4 digits] h) Key in current month [2 digits] i) Key in current day [2 digits] j) Key in current hour [2 digits] k) Key in current minute [2 digits] * Time setting are on 24 hour basis 2. Door Param To configure all door setting, including door open time, lock release time, door security, alarm, and pin access mode. e) Select [1] System Param f) Select [2] Door Param to set and change Door Configuration [1]Security [ON / OFF], Press[ ] Enter to change (default ON) [2]Lock Release Time, range from 1 Sec 15 Sec (default 05 Sec) [3]Door Open Time, range from 1 Sec 30 Sec (default 10 Sec) CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 09

3. Master Reset This menu is for clearing all the data that store inside the system. e) Select [1] System Param f) Select [3] Master Reset g) Enter Master password. (Entering password will clear the data instantly) * Caution: Performing Master Reset will clear all the database and the process NOT REVERSIBLE! 4. Password Menu where all the password or PIN can be change. 4.1 Master Password a. Press [F1] to enter the System Menu a) Press [6] to scroll down to next page b) Select [3] Programming to enter the Programming Menu c) Enter master password & press ' ' d) Select [1] System Param to set and change System Configuration e) Press [6] to scroll down to next page f) Select [4] Password to enter. g) Select [1] Master password to change Master Password h) Enter current password, Press [*] Undo when key in wrongly i) Enter 10 digits New Password, Press [*] Undo when key in wrongly j) Repeat New Password, Press [*] Undo when key in wrongly * New password can be program either 1 digit to 10 digits 4.2 Reader lock code (default Password 3333) To set and change reader lock code e) Select [1] System Param to set and change System Configuration f) Press [6] to scroll down to next page g) Select [4] Password to enter. h) Select [2] Reader lock code to change the lock code i) Enter current code, Press [*] Undo when key in wrongly j) Enter 4 digits New code, Press [*] Undo when key in wrongly k) Repeat New code, Press [*] Undo when key in wrongly 10 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

4.3 Alarm PIN (default Password 3333) To set and change alarm pin e) Select [1] System Param to set and change System Configuration f) Press [6] to scroll down to next page g) Select [4] Password to enter. h) Select [3] Alarm Pin to change alarm PIN i) Enter current PIN, Press [*] Undo when key in wrongly j) Enter 4 digits New PIN, Press [*] Undo when key in wrongly k) Repeat New PIN, Press [*] Undo when key in wrongly 4.4 Global PIN 1(default Global PIN 1 is null. Global PIN not active) To set and change global pin 1 e) Select [1] System Param to set and change System Configuration f) Press [6] to scroll down to next page g) Select [4] Password to enter. h) Select [4] Global PIN 1 to change access PIN i) Enter current PIN (Press[ ] Enter if still default), Press [*] Undo when key in wrongly j) Enter 4 digits New PIN, Press [*] Undo when key in wrongly k) Repeat New PIN, Press [*] Undo when key in wrongly * New password can be program either 1 digit to 4digit 4.5 Global PIN 2 (default Global PIN 2 is null. Global PIN not active) To set and change global pin 2 e) Select [1] System Param to set and change System Configuration f) Press [6] to scroll down to next page g) Select [4] Password to enter. h) Select [5] Global PIN 2 to change access PIN i) Enter current PIN (Press[ ] Enter if still default), Press [*] Undo when key in wrongly j) Enter 4 digits New PIN, Press [*] Undo when key in wrongly k) Repeat New PIN, Press [*] Undo when key in wrongly * New password can be program either 1 digit to 4digit CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 11

5. ACCESS MODE To set and change mode operation e) Select [1] System Param to set and change System Configuration f) Press [6] to scroll down to next page g) Select [5] Access Mode a) 4 Mode can be select here [1] Card + Finger [2] Card + Pin [3] Card Only [4] Card and/or finger Note: ID & finger mode is a available concurrently with above 3 operations mode. Please refer to page 15 on 'How to use finger only access'. 12 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

B) SECURITY LEVEL Set fingerprint security level to accommodate different fingerprint condition e) Select [2] Security Level f) Enter value 1 to 9999. Default value 50 Important Note Security Level 1 is the highest security level Security Level 9999 is the lowest security level Changing of security level alter the verification process. Lower security level decreases verification level hence increases false acceptance rate (FAR) Security Level Highest High Medium Low Lowest False Rejection Rate (FRR) Highest High Medium Low Lowest False Acceptance Rate (FAR) Lowest Low Medium High Highest C) CALIBRATE User can recalibrate the sensor if the the sensor not respond to a finger placement. Make sure there not be a finger on the sensor during the calibration. e) Select [3] Calibrate f) If the calibration successful, display will return to the its menu. D) ENROLL MASTER Enrollment fingerprint of master card user. c) Select [3]Programming e) Select [4] Enroll Master to enroll master user f) Select [1] New ID for new register (* For new ID, proceed to step 'h') OR Select [2] Specify ID to modify existing ID information OR Select [3] Pre-registered ID to select pre-registered ID g) Select [1] Add To Same ID to adding more than one template in same ID h) Select [1] Add Proxi Card. i) Select [1] Flash Card to pre-register card OR select [2] Key In Card to manual enter pre-register card. j) Select [1] Add To Same Card OR select [2] Create New Record for previous registered without finger template. k) Select [1] Add pin to add card pin number OR [2] No Pin to leave it blank l) Select [1] Scan finger to register fingerprint template & Scan finger, repeat it 5 times until system confirm it OR [2] No finger to add card information only. 13 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

E) COMMUNICATION 1. Relay Board Comm Enable/ disable communication port to relay board d) Key in Programming Menu password [10 digits] e) Select [5] Communication to enter the Programming Menu f) Select [1] Relay board comm to enter menu g) Press[ ] Enter to 'ON' or 'OFF' relay board communication. MENU 4 ALARM A) ALARM (default alarm pin 3333) To activate/ deactivate alarm mode c) Select [4] Alarm d) Enter alarm pin [4 digits] e) Press [ ] Enter to 'ON' or 'OFF' alarm. 14 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

OPERATION PROCEDURE How to use only finger to access? a) Just place the registered finger on the sensor, b) Wait until the system granted scanned finger How to use only PIN to access? a) Press [*] to enter the Global Pin Menu b) Key in 4 digits PIN number. Global PIN 1 or Global PIN 2 can be use to access. * Please refer to page 11 to set Global Pin. How to activate alarm mode? Refer to page 14. Follow the same step to deactivate the alarm. How to change to 'card' only mode? a) Refer to page page 12 under Access Mode. b) Select [3] Card to activate card only operation mode. CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 15

CASS9000 Standalone Configuration 12vDC 3A Power Supply (Any DC 12V power supply) +ve -ve CASTLE STR100 +12V GND C+ C- IN1 IN2 IN3 IN4 GND CM1 NO1 NC1 CM2 NO2 NC2 RELAY 1 RELAY 2 +ve -ve +12V (Red Wire) GND (Orange Wire) C+ (Green Wire) C- (Yellow Wire) +ve 12vDC 3A Power Supply (Any DC 12V power supply) Alarm Siren -ve Door Sensor Door Release Button Break Glass Alarm Sensor Electromagnetic Lock Surge Protection Card 16 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM

SENSOR MAINTENANCE In normal use, monthly cleaning of the sensor surface is recommended. To clean the finger drive ring and the sensor surface, follow these steps: 1. Remove the electrical power from the fingerprint sensor by disconnecting it from its power source. 2. Use any type of household kitchen or window cleaner, such as Formula 409, Fantastic, Windex, or any generic versions of these cleaners. DO NOT use chlorine-based cleaners, such as Clorox bleach, non-chlorine bleach, or chlorine-based bathroom or mildew cleaners. Chlorine based cleaners will not necessarily affect the functionality of the finger print sensor, but they will discolor the finger drive ring and could damage the surrounding circuitry around the fingerprint sensor. D0 NOT use any solvents, such as acetone, MEK, TCE, paint thinner, turpentine, etc. Solvents will not adversely affect the sensor, but they might damage the surrounding enclosure and peripheral components to the sensor. 3. Wet one end of a cotton swab (not soaking or dripping wet) with one of the above mentioned cleaners. Gently rub the sensor surface and finger drive ring with the wet cotton swab, slowly rotating the swab so a new, clean surface of the swab is constantly exposed to the sensor surface. Do not allow cleaner to drip or run down into the electronics around the sensor. 4. After cleaning with the wet swab, gently rub the surfaces again with a dry cotton swab. Use a clean swab each time the sensor is cleaned. (If a dirty swab is used, it may make the sensor dirty again.) CASS9000 FINGERPRINT DOOR ACCESS SYSTEM 17

ITEM CASS9000 TECHNICAL SPECIFICATION Card Reading Distance DESCRIPTION ± 5 cm Sensor FP8600 TruePrint Fingerprint Template Fingerprint Capture Time Processor RTC (Real Time Clock) Flash Memory RAM Watchdog Housing Display Unit Operating Temperature Humidity Audible Device Backup Battery Baud Rate (DIU to reader) EMI Protection Input Voltage Input Current Communication Cable Usage Cabling 6144 Bytes / Template ± 1 sec 16 bits processor Yes 64Mb 64Mb Yes Well designated and high grade ABS casing to protect the reader and PCB Graphic 32 x 122 LCD with blue backlight display 0 65 C 95% non-condensing Yes Rechargeable SuperCap 9600bps Yes 12Vdc 13.8Vdc 500mA 1 pair from door interface to CASS9000 1 Pair from CT9000 to PCI unit RS485 standard cable 18 CASS9000 FINGERPRINT DOOR ACCESS SYSTEM