Dear Valued Customer:

Similar documents
MODEL 6105 FINGERPRINT DEVELOPMENT CHAMBER OPERATIONS MANUAL

Dear Valued Customer:

ENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/

6 CUFT BENCHTOP CO 2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and

Dear Valued Customer:

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Dear Valued Customer:

Operator s Manual. Histology Bath

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

Operator s Manual. IP-100 Immersion Probe Cooler

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

REACH-IN CO2 INCUBATOR OPERATIONS MANUAL. For Models , , , , , ,

Environmental Chambers Series: reach-in & benchtop capacities

Refrigerated Incubator Model and Operating Instructions

Corning LSE 6L Digital Water Bath

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Installation Instructions

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

BENCHTOP FOR PO Box 715

6020 & 6040 SERIES ENVIRONMENTAL CHAMBERS OPERATIONS MANUAL FOR MODELS 6020, 6021, 6022, 6023, 6025, , 6041, 6042, 6043, 6045, 6047

Surna 25-Ton Chiller Operating & Maintenance Manual

1 HP Air Mover. Owner s Manual

ENVIRONMENTAL CHAMBERS OPERATIONS MANUAL. For -10 Series Models 7000, 7001, 7002, 7003

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

POLYMIX PX-IG 2000 Operating Instructions

Superdryer Dehumidifiers

Digital Heat Block User Manual

DUST FREE CARBON Whole House Air Purifier

TTT Digital Incubator

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL FOR MODELS

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Thermo-Sealer. Manual Heat Sealer. User Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

Reacti-Therm I and III Heating Modules

Buzzer Unit. TAN-5000 Series. Operating Manual

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

DEHUMIDIFIER. User Manual 50BT, 70BT

MaxLite LED MICRO-T PANEL

OWNER'S MANUAL T0140. Contents Page #

(HSTAT Series) Instruction Manual

IW-25-2 Dehumidifier Installation & Operations. Manual

MaxLite LED Vapor Tight Linear Fixture

Instruction Manual. Double Candy Apple Cooker

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

ASPIRE Laboratory Aspirator

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Series: MBC1-TC Mini Benchtop Temperature Controller

Reach-in CO 2 Incubators. 6024, 6026, 6044 & 6046 series

Installation, Operation & Service Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

e Heater/Exhaust Fan/Light User s Guide

Type 40HT Electrode Rebaking Ovens

Black Body Calibration Source User Manual

XC Portable Air Conditioning

Whynter Portable Ice Maker 33 lb capacity - White

CARON 6000 SERIES ENVIRONMENTAL TEST CHAMBERS

WITH OMRON E5CC CONTROL

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Owner & Operator s Manual. Table of Contents

e Bath Fan with Light User s Guide

CO 2 Incubators: 7401, 7402 & 7403 Series

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Installation Instructions

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

e Bath Fan with Light User s Guide

5) Do not start or stop the unit by inserting or pulling out the power plug.

Dry Bath Heating Systems

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Document No

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

240 ASSEMBLY & OPERATION MANUAL

User s Information Manual

Non-Programmable Digital Thermostat

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Isotemp Low Temperature Incubator

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Rules for Safe Operation

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Reacti-Therm I and III Heating/Stirring Modules

INSTALLATION INSTRUCTIONS

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Digital Non-Programmable

Transcription:

Dear Valued Customer: Thank you for purchasing CARON Products & Services equipment. We appreciate your business and look forward to being your preferred supplier of controlled environment equipment products in the future. At CARON, we are committed to continuous quality improvement. Our goal is to supply our customers with highly reliable equipment at a fair price. In order to openly monitor our performance, we would appreciate your feedback on our products and services. If you have questions, or any suggestions for improvement based on the installation or operation of the equipment you have purchased, please contact our service department at www.caronproducts.com or 740-373-6809. Thanks again for your business! Model 6105 Operations Manual Rev L 11-15-17 Page 2 of 27

Revision Log Version Date Description K 08-02-17 Updated consistency between all manuals L 11-15-17 Added door heat and light connection instructions Model 6105 Operations Manual Rev L 11-15-17 Page 3 of 27

EQUIPMENT LIMITED WARRANTY Please review this section before requesting warranty service. At CARON, one of our primary goals is to provide customers with high levels of personal service and top quality products, delivered on time, backed by technical service and supported for the life of the product. Before contacting us for warranty service, please be aware that there are repairs that are not covered under warranty. WARRANTY DEFINED Caron Products & Services, Inc. (herein after CARON) hereby warrants that equipment manufactured by CARON is free from defects in materials and workmanship when the equipment is used under normal operating conditions in accordance with the instructions provided by CARON. COVERED: Parts and labor for a period of one (1) year from date of shipment. Any part found defective will be either repaired or replaced at CARON's discretion, free of charge, by CARON in Marietta, OH. Parts that are replaced will become the property of CARON. If CARON factory service personnel determine that the customer's unit requires further service CARON may, at its sole discretion, provide a service technician to correct the problem, or require the return of the equipment to the factory or authorized service depot. CARON will have the right to inspect the equipment and determine the repairs or replacement parts necessary. The customer will be notified, within a reasonable time after inspection, of any costs incurred that are not covered by this warranty prior to initiation of any such repairs. NOT COVERED: Calibration of control parameters. Improper installation; including electrical service, gas and water supply tubing, gas supplies, room ventilation, unit leveling, facility structural inadequacies or ambient conditions that are out of specification. Cost of express shipment of equipment or parts. Any customer modifications of this equipment, or any repairs undertaken without the prior written consent of CARON, will render this limited warranty void. CARON is not responsible for consequential, incidental or special damages; whether shipping damage or damages that may occur during transfer to the customer s point of use. When the equipment is signed for at the customer s site, ownership is transferred to the customer. Any damage claims against the shipping company become the responsibility of the customer. Repairs necessary because of the equipment being used under other than normal operating conditions or for other than its intended use. Repair due to the customer's failure to follow normal maintenance instructions. Parts considered consumable; including: light bulbs, filters, gases, etc. Damage from use of improper water quality. Damage from chemicals or cleaning agents detrimental to equipment materials. Force Majeure or Acts of God. This writing is a final and complete integration of the agreement between CARON and the customer. CARON makes no other warranties, express or implied, of merchantability, fitness for a particular purpose or otherwise, with respect to the goods sold under this agreement. This warranty cannot be altered unless CARON agrees to an alteration in writing and expressly stated herein shall be recognized to vary or modify this contract. Ohio Law governs this warranty. Model 6105 Operations Manual Rev L 11-15-17 Page 4 of 27

EQUIPMENT INTERNATIONAL LIMITED WARRANTY Please review this section before requesting warranty service. At CARON, one of our primary goals is to provide customers with high levels of personal service and top quality products, delivered on time, backed by technical service and supported for the life of the product. Before contacting your distributor for warranty service, please be aware that there are repairs that are not covered under warranty. WARRANTY DEFINED Caron Products & Services, Inc. (herein after CARON) hereby warrants that equipment manufactured by CARON is free from defects in materials and workmanship when the equipment is used under normal operating conditions in accordance with the instructions provided by CARON. COVERED: Parts for a period of two (2) years from date of shipment. Any part found defective will be either repaired or replaced at CARON's or their authorized representative s discretion. Parts that are replaced will become the property of CARON. If CARON or their authorized representatives determine that the customer's unit requires further service, CARON or the representative may, at its sole discretion, provide a service technician to correct the problem, or require the return of the equipment to the an authorized service depot. CARON or their authorized representative will have the right to inspect the equipment and determine the repairs or replacement parts necessary. The customer will be notified, within a reasonable time after inspection, of any costs incurred that are not covered by this warranty prior to initiation of any such repairs. NOT COVERED: Calibration of control parameters. Improper installation; including electrical service, gas and water supply tubing, gas supplies, room ventilation, unit leveling, facility structural inadequacies or ambient conditions that are out of specification. Cost of express shipment of equipment or parts. Any customer modifications of this equipment, or any repairs undertaken without the prior written consent of CARON, will render this limited warranty void. CARON and their representative are not responsible for consequential, incidental or special damages; whether shipping damage or damages that may occur during transfer to the customer s point of use. When the equipment is signed for at the customer s site, ownership is transferred to the customer. Any damage claims against the shipping company become the responsibility of the customer. Repairs necessary because of the equipment being used under other than normal operating conditions or for other than its intended use. Repair due to the customer's failure to follow normal maintenance instructions. Parts considered consumable; including: light bulbs, filters, gases, etc. Damage from use of improper water quality. Damage from chemicals or cleaning agents detrimental to equipment materials. Force Majeure or Acts of God. This writing is a final and complete integration of the agreement between CARON and the customer. CARON makes no other warranties, express or implied, of merchantability, fitness for a particular purpose or otherwise, with respect to the goods sold under this agreement. This warranty cannot be altered unless CARON agrees to an alteration in writing and expressly stated herein shall be recognized to vary or modify this contract. Ohio Law governs this warranty. Caron Products & Services, Inc. PO Box 715 Marietta, OH 45750 740-373-6809 Model 6105 Operations Manual Rev L 11-15-17 Page 5 of 27

TABLE OF CONTENTS SECTION INTRODUCTION...7 INSTALLATION...9 Power requirements...10 Water connections...10 OPERATION...12 Start up...12 Temperature set point...13 Countdown timer...14 Humidity set point...15 Low water level alarm...15 Viewing light...17 Unlocking the Controllers...18 CALIBRATION...19 MAINTENANCE...21 Routine maintenance...21 Brief Troubleshooting...22 Spare Replacement Parts...26 Declaration of Conformity...27 Model 6105 Operations Manual Rev L 11-15-17 Page 6 of 27

INTRODUCTION CARON s 6105 fingerprint chambers are designed specifically to create conditions for developing DFO, Ninhydrin, and other fingerprint development process prints. The chamber features rapid condition recovery after the chamber door is opened and closed. The large viewing area offers easy observation of critical samples. The chamber interior is made of high quality, corrosion resistant material. Specifications Temperature Range 40ºC to 100 C Temperature Control ± 0.5 C Humidity Range 40 to 80% RH (of specified temperature range) Humidity Control ± 3% Interior Dimensions 24 W x 18 D x 22 H Exterior Dimensions 28 W x 26 D x 37 H Work Space 5 ft 3 Shelf Work Area 5.3 ft 2 (shelf plus bottom) Electrical 208/230V, 15 A, 60 Hz Model 6105-2 208/230V, 15 A, 50 Hz Model 6105-3 Specifications are based on exhaust air vent closed. Features Digital temperature and humidity display, PID control 1/16DIN, set-point & process value displayed simultaneously Digital countdown programmable timer Rapid recovery after chamber door is opened and closed Solid state sensors eliminate need for frequent replacement of wicks Chamber interior made of high quality, corrosion resistant material Exhaust adaptable air vent Forced air flow to ensure uniform internal conditions Large front viewing window Low water level alarm Model 6105 Operations Manual Rev L 11-15-17 Page 7 of 27

INTERNATIONAL SYMBOLS AND DEFINITIONS Warning of hazardous area Warning of dangerous electric voltage Earth (ground) protective conductor WARNINGS Local government may require proper lamp disposal Use eye protection, gloves and aprons if exposure to hazardous materials could occur Model 6105 Operations Manual Rev L 11-15-17 Page 8 of 27

INSTALLATION Unpacking This product has been completely tested, cleaned and packed for shipment. Carefully remove all packing material. Please examine the chamber completely. Should any damage be found, notify the delivering carrier immediately. Report any shortages to your local distributor or contact CARON customer service at 740-373-6809, 800-648-3042 (USA only) or www.caronproducts.com. Caron provides full on-site installation services for all models. Our installation services guarantees the proper set-up and startup of all equipment. Please contact the Service Department at 740-373-6809 or www.caronproducts.comfor details. Chamber Location The chamber must be located in a dry, clean, and level area. Allow a 2 inch (51 mm) clearance from the back of chamber for proper air circulation. Locate the chamber in an area out of direct sunlight and away from heating and cooling ducts. Caution: Do not put more than 5 lbs (2.3kg) on top of unit. The figure below shows the exhaust port on the back of the chamber. Install rubber stopper/vent into port and press in firmly. Make sure vent is in upward position as shown. If external ducting to a fume hood or exterior vent is necessary, make connection here. Note that temperature, humidity, and recovery time will be affected. Model 6105 Operations Manual Rev L 11-15-17 Page 9 of 27

Connect the unit to a dedicated grounded outlet that matches the units power requirements. Failure to do so could result in electrical shock or damage to the unit. Power Requirements The power cord of this chamber is equipped with a grounded plug. Be sure to connect the ground. CARON recommends that the chamber have a dedicated wall outlet. Verify correct power supply required for particular unit. (Nema 6-15 15A Cord, Model 6105-2 only.) (CEE 7/7 Continental European 16A Cord, 6105-3 only) Water Connections Plumb the water drain connection to a facility drain. Connect the water inlet to a water supply. The chamber requires distilled, reverse osmosis or deionized water with resistivity between 0.05 & 1 Mega Ohm-cm and ph above 6.5. Using water outside this range will void the warranty. Door Heat and Light Connection Locate the connection input on the bottom right of the door. Be sure the corresponding yellow connector is properly inserted. Note: The black shroud on the yellow connector must be pulled back for insertion and then pushed forward once connected to lock. Carboy water bottle: BTL101 (optional) Mount the universal carboy holder either on the top of the chamber or on the side (as shown below). Use the mounting screw holes provided and secure the holder. Connect tubing to carboy, fill bottle and install as shown. The water supply must gravity drain. The bottle cap must have a weep hole for it to work properly. Carboy Water inlet to chamber (supply) Universal carboy holder Water outlet from chamber (drain) Model 6105 Operations Manual Rev L 11-15-17 Page 10 of 27

Condensate Recirculating System: CRSY102 (optional) The Condensate Recirculating System can be used in conjunction with CARON s 6105 chambers as a water delivery system. This system is typically used in facilities where a drain or in-house source of distilled, RO or deionized water is not available. The system provides continuous, clean, filtered water to the chamber s humidity injection system, collects and recycles the condensate that forms in the base of the chamber. Refer to instructions with the CRSY102 for connection details. Use fittings provided with 6105 to connect to CRSY102. Install Shelf / Hanging Rails Insert both shelf tracks into the chamber (see picture below). Each unit is equipped with both a shelf and evidence rails/clips. Orient the shelf handle toward the front. Maximum shelf load is 22lbs (10kg) per shelf. Right shelf track Sliding shelf Model 6105 Operations Manual Rev L 11-15-17 Page 11 of 27

OPERATION Start Up Be sure the water connections are properly made and the exhaust vent properly closed (see installation section). Turn on unit by pressing the power switch. The power on indicator light, temperature and timer displays will illuminate. Air should be gently circulating internally. Power On indicator light Temperature and timer displays Power switch Control panel layout Light switch Humidity control enable switch Temperature controller Countdow n timer Humidity controller Model 6105 Operations Manual Rev L 11-15-17 Page 12 of 27

Temperature Actual temperature Infinity/Home button Temperature set point Up button Down button EZ button Advance button The unit is capable of reaching temperatures that could result in burns. Always wear protective clothing when accessing the unit. Use caution when opening the outer door. Change Set Point Use the up and down arrow push-buttons to obtain the desired temperature set point (red upper display). The temperature is displayed in ºC. The chamber drops in temperature slowly. For faster recovery time when lowering the temperature, open the door. The chamber will only control temperature within the specified range. Model 6105 Operations Manual Rev L 11-15-17 Page 13 of 27

Countdown Timer The countdown timer provides users with a way to alert them to check or remove chamber contents. It does not turn the chamber off or in any way affect the temperature and humidity control. Time is displayed in minutes and seconds. Start button Reset button Time remaining Total countdown time Unused buttons Up and down arrow buttons Using the timer 1. Set total countdown time to desired value using the four up and down arrow buttons. 2. Press the start button. 3. When the time remaining reaches 0:00, the alarm buzzes and display turns red for 3 seconds. 4. Press the reset button; the time remaining resets to the total countdown time Press the reset button at any time to stop the countdown. Timer just reached 0:00, alarm is buzzing 3 seconds after timer reaches 0:00, alarm is off Model 6105 Operations Manual Rev L 11-15-17 Page 14 of 27

Humidity For fingerprint development processes that require humidity such as Ninhydrin, 1, 2-Indanedione, Nickel Nitrate, 5-MTN, and Zinc Chloride, the humidity should be enabled. To enable humidity control, turn the humidity control enable switch on. This turns on the humidity controller display and fills the steam generator with water. When the humidity switch is enabled, the glass viewing window is heated to minimize the condensation on the inside. For fingerprint development processes that do not require humidity (temperature control only), the humidity switch should be off. Turning the humidity enable switch off drains the steam generator. Low water level alarm light Humidity control enable switch Humidity controller Low water level alarm The low water level alarm light will illuminate if the humidity control switch is enabled and, after 30 seconds, the internal steam generator does not fill properly. See troubleshooting guide if necessary. Once an adequate water supply is connected and the steam generator fills, the alarm light will automatically reset. If the low water level alarm light is on, the chamber will not control humidity. Model 6105 Operations Manual Rev L 11-15-17 Page 15 of 27

Change Set Point Low water level alarm light Actual humidity Infinity/Home button Up button Humidity set point EZ button Down button Advance button Use the up and down arrow push-buttons to obtain the desired humidity set point (red upper display). The relative humidity is displayed in %. To lower the humidity, open the door or rear vent. The chamber will only control humidity within the specified range. Model 6105 Operations Manual Rev L 11-15-17 Page 16 of 27

Viewing light To illuminate the interior, turn on the light switch. If lighting does not come on, see troubleshooting guide. Light switch Model 6105 Operations Manual Rev L 11-15-17 Page 17 of 27

Unlocking the Controllers The temperature and humidity controllers are factory programmed for precise control. Unlocking the controllers gives the user access to all parameters. Modifying parameters that are not thoroughly understood can adversely affect chamber performance that will not be covered under warranty. To unlock an individual controller 1) Press and hold the advance and infinity keys simultaneously for six seconds 2) Press the up key until LOC is displayed in the upper display 3) Press the advance key until rloc is displayed in the lower display 4) Press the up key to change the security level from 2 to 5 5) Press the advance key until sloc is displayed in the lower display 6) Press the up key to change the security level from 2 to 5 7) Press infinity key twice to return to the main menu All controller parameters are now available to be modified. Once the appropriate changes have been made, it is highly recommended to relock the controllers per the instructions below. Locking the Controllers To lock an individual controller 1) Press and hold the advance and infinity keys simultaneously for six seconds 2) Press the up key until LOC is displayed in the upper display 3) Press the advance key until rloc is displayed in the lower display 4) Press the up key to change the security level from 5 to 2 5) Press the advance key until sloc is displayed in the lower display 6) Press the up key to change the security level from 5 to 2 7) Press infinity key twice to return to main menu All controller parameters are now locked. Model 6105 Operations Manual Rev L 11-15-17 Page 18 of 27

CALIBRATION The temperature and humidity systems can all be calibrated as necessary. CARON recommends an annual calibration check of each system. Before making a calibration adjustment, allow the cabinet to stabilize a minimum of 12 hours from a power off condition. If the unit has been in operation, allow a minimum of 3 hours of stable operation at all set-points. If you do not have the appropriate reference instruments to perform calibration, contact CARON s service department for on-site calibration at www.caronproducts.com. Caron also provides validation services which ensures that the unit is functioning properly according to IQ, OQ and PQ protocols which satisfy FDA guidelines for qualification verification of equipment. Infinity/Home button Advance button Calibration Procedure: 1. Place an external temperature/humidity detector* as close to the center of the chamber as possible. Allow sufficient time for the chamber and the sensor to stabilize. It is recommended to place the detector with only the heat on to allow the sensor to stabilize to the temperature. Once the sensor has had sufficient time to stabilize; turn the humidity on. This should eliminate condensation on the sensor. It is recommended that the acceptable range is ± 1ºC and ± 2% RH. 2. If the reading difference is within the acceptable range; no changes will need to be made. If the difference is greater than the acceptable range; use the following steps to adjust the controller to be within the acceptable range. The difference will be used as the offset below. 3. To make the adjustment to controllers, press the advance key until the green display reads i.cal. 4. Press the UP arrow to increase the calibration offset. Press the DOWN arrow to decrease the offset. 5. Press the infinity key to save calibration and return to main menu. *Caron recommends using NIST traceable device to calibrate the controllers. A Vaisala HMI41/HMP46 temperature/humidity detector or a similar device is recommended. A wick type Model 6105 Operations Manual Rev L 11-15-17 Page 19 of 27

sensor is not recommended due to the likelihood that the sensor will become saturated and give inaccurate readings. Temperature calibration example If the chamber temperature display reads 40.0 C and the calibrated independent sensor shows 40.3 C, set the i.cal offset value to 0.3 C. If the calibrated independent sensor shows 39.6 C, then the entered offset should be negative. In this example the required offset to i.cal would be - 0.4 C. Humidity calibration example If the chamber temperature display reads 80% and the calibrated independent sensor shows 83%, set the i.cal offset value to 3.0%. If the calibrated independent sensor shows 74 C, then the entered offset should be negative. In this example the required offset to i.cal would be -6.0%. Model 6105 Operations Manual Rev L 11-15-17 Page 20 of 27

MAINTENANCE The CARON chamber has been robustly designed to minimize performance problems. However, regular maintenance is very important for continuous trouble free operation. As a general rule, CARON recommends an annual calibration check of the temperature, and humidity systems. CARON offers a full range of on-site calibration and validation services. We also offer preventative maintenance contracts on our equipment. Contact our Service department for details at 740-373-6809 or visit us on the web at www.caronproducts.com. WARNING: Before removing top/back panel, disconnect all power! Electrical components (circuit breakers, fuses, relays, power supplies, etc.) are located underneath the top/back panel. For additional service support, contact your local distributor or CARON service department at www.caronproducts.com. When contacting CARON, please provide model number and serial number Routine Maintenance Routine chamber maintenance is necessary to keep the chamber working properly. The recommended chamber maintenance schedule is: a) Clean interior chamber (as needed) b) If the humidity control portion of the chamber is going to be unused for 20 days, the small internal water reservoir should be drained. To drain the internal reservoir: turn the chamber on set the humidity switch to off set the temperature to 100ºC open the back vent (remove stopper) run for four hours leave humidity switch off until humidity control is required c) Check drains for blockage (monthly) Model 6105 Operations Manual Rev L 11-15-17 Page 21 of 27

Brief Troubleshooting Unit won t reach temperature set point Is the set point within the unit specification range? Is the rear vent closed? Is the door closed and latched? Can air flow freely throughout the chamber? Inhibited air flow can trip the over temperature safety device. Remove airflow obstructions and let stabilize for 30 minutes Temperature displayed is different than measured temperature inside chamber Can air flow freely throughout the chamber? Contact CARON service department to apply a temperature offset Temperature is higher than set point Is the set point within the unit specification range? Is the ambient temperature no more than 25ºC? Turn unit off and open door for 1 hour. Humidity controller is blank (temperature controller is illuminated) Is the humidity enable switch on? Unit won t reach humidity set point Is the rear vent closed? Is the door closed and latched? Is the low water level alarm light on? Is there adequate water supply? Can air flow freely throughout the chamber? Is the humidity set point within the unit specification range? Low water alarm light stays lit Is the water supply connected? Is there adequate water being supplied to the chamber? Are there any air traps in the line? If using a carboy or other reservoir, is their a weep hole to allow free flow? Humidity displayed is different than measured humidity inside chamber Can air flow freely throughout the chamber? Contact CARON service department to apply a humidity offset Humidity is higher than set point. Is the set point within the unit specification range? Is the drain line connected and draining properly? No kinks or up-hill traps in the line? Is the internal air saturated? Turn humidity enable switch off, open door, and set temperature to 100ºC for 1 hour to dry out the chamber. Is water present in exhaust vent? Remove stopper and let water drain out. Interior lights won t come on Model 6105 Operations Manual Rev L 11-15-17 Page 22 of 27

Are lights turned on? Is the connector on the bottom of the door switch connected (see below)? Door connector Glass fogs up on inside Is the humidity switch on? Is the connector on the bottom of the door switch connected (see picture)? Is the door sealed tightly? Is the door gasket collapsed? Has the unit stabilized 1 hour? Model 6105 Operations Manual Rev L 11-15-17 Page 23 of 27

Electrical Schematic Model 6105 Operations Manual Rev L 11-15-17 Page 24 of 27

Model 6105 Operations Manual Rev L 11-15-17 Page 25 of 27

Spare Replacement Parts General Part Number Description MTR-107 BLOWER MOTOR BLW-110 BLOWER WHEEL CTR-122 WATLOW STANARD CONTROLLER POW-108 24V POWER SUPPLY CRD-108 LINE CORD 50 HZ ONLY GSK-136 DOOR GASKET LGT-143 DOOR LIGHT Temperature Related Part Number HTR-143 RMT-114 RMT-115 RTD-101 REL-103 Description AIR HEATER SNAP DISK 225 F THERMAL FUSE 169 C TEMPERATURE SENSOR HEATER SOLID STATE RELAY Humidity Related Part Number HUM-114 SOL-133 SOL-135 LEV-106 HTR-144 REL-103 CTR-124 REL-150 Description RH SENSOR HUMIDIFICATION SOLENOLD DRAIN SOLENOLD STEAM GENERATOR LEVEL SWITCH STEAM GENERATOR HEATER HUMIDITY SOLID STATE RELAY TEMPERATURE LIMIT CONTROLLER TIME DELAY RELAY Model 6105 Operations Manual Rev L 11-15-17 Page 26 of 27

DECLARATION OF CONFORMITY CE Compliant Product Declaration of Conformity Caron Products 27640 State Route 7 Marietta, OH 45750 USA Declares that the following product: Designation: 6105 Model Number: 6105-3 Classification: Electrical Equipment for Measurement, Control, & Lab Use Rated Voltage: 220-240 V~ (ac) Rated Frequency: 50Hz Rated Power Consumption: 15 amps Meets the essential requirements of the following European Union Directive(s) using the relevant section(s) of the normalized standards and related documents shown: 89/336/EEC Electromagnetic Compatibility Directive EN 61326:1997 Laboratory Equipment, Immunity Measurement & Control requirements EN 61000-3-2:2000 Limits for harmonic current emission EN 61000-4-2:1995 Electrostatic Discharge EN 61000-4-3:1995 Radiated Susceptibility EN 61000-4-4:1995 Electrical Fast Transient EN 61000-4-5:1995 Lightning Surge EN 61000-4-6:1996 Conducted Disturbances Induced by RF Fields EN 61000-4-11:1994 Voltage Variations, Dips and Interruptions CISPR 11:1990 Emissions Standards 73/23/EEC Low-Voltage Directive EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use. Model 6105 Operations Manual Rev L 11-15-17 Page 27 of 27