SPACE NEEDS PROGRAM. Leicester Fire Department. Leicester Fire Station. July 27, 2009

Similar documents
Table of Contents. Brewster Fire and Rescue Department Town of Brewster Brewster Fire Headquarters

EXHIBIT A-1 CITY OF BELLFLOWER JANITORIAL MAINTENANCE SPECIFICATIONS

EQUIPMENT GUIDE LIST - CHAPTER

TRUCKING CO. OFFICE AND MAINTENANCE FACILITY

SPACE TYPE: JUDICIAL CHAMBER

FOOD SERVICE May 6, 2016

SPACE TYPE: CHILD CARE

FOOD SERVICE May 6, 2016

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Report To: Fire Commissioners From: Chief Sitar CC: Fire Station Committee Date: September 29, 2014 Re: Fire Station Needs

CDLC Rehab. Karen E. Conway Conway Creations. As inspired by your logo, hues of blues and yellows enliven durable commercial flooring and hardworking

WPUMC Capital Report Existing Facilities February 19, Maintenance Coordinator George Smit

Coquille Indian Housing Authority Maintenance Report February 2017

All food service facilities must be equipped with the following items for the pre-opening inspection:

Friday, March 8, 13. Furniture Arrangement & Traffic Patterns

FOR SALE OR LEASE OVERVIEW GREENCASTLE PIKE HAGERSTOWN, MD 21740

Apartment Inventory Check-list

Junk Pickup: Accepted Large Items

Additional Information 1626 Arapahoe Trail

JANITORIAL SPECIFICATIONS

Access Statement For Bluebell Cottage, Whittingham

Special Features 3638 Quail View Road Charlotte, NC ,076 SF Heated Living Area Acre Lot July 14, 2009

Craig A. Rush Presents Edinborough Circle, Perrysburg

MOLSON S BANK BUILDING 166 EAST HASTINGS STREET, VANCOUVER, BC

32 bernard avenue. Proudly Presented By Dagmar Hansen & Jimmy Molloy Sales representatives Chestnut Park Real Estate Limited, Brokerage

For details or to arrange a showing, call (800) or

Living in Whittemore Hall Some Helpful Info

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

Bedroom Front / Middle / Back Right / Left Side Charges $5 $10 $5 $5 $10 $5 $5 $5 $5 $5/ea $10 $5 $3/ea

FEATURES PLEASANT PROSPECT RD. BOWIE, MD 20721

9333 Ehler Avenue SE Delano, MN

TERRACE VIEW APARTMENTS

DAMAGE CODES* CODE DAMAGE COST

TERRACE VIEW APARTMENTS

22576 INSPIRATION POINT INTERIOR FEATURES BY ROOM

3 rd Floor Programming Date: April 24, 2011

All community assets are to be entered or updated in OneSite upon:

NP MASTER LIST OF ASSETS Do NOT Edit

TYPICAL GENERAL ADMINISTRATIVE OFFICES 60,000 SQ. FOOT BUILDING. Entrance ways (2, plus the single door to the left check each night)

CULINARY OPERATIONS September 30, 2010

15325 MASONWOOD DRIVE GAITHERSBURG, MARYLAND 20878

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

PLATTEVILLE MIDDLE SCHOOL

room data sheet ORANGE HALL 341 GORE AVENUE, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Home Contents Inventory Worksheet

Agriculture & Machinery. Appliances. Farm Machinery 150 Farm Produce 50 Farm Tools 10 Miscellaneous 10 Plant Equipment 100

Regulations Regarding the Requirements for the Arranging and Equipping of the Accommodation Centre

TERRACE VIEW APARTMENTS

14609 Delmar Street The Pavilions Estates of Leawood

SUN & FUN SIESTA KEY WATERFRONT HOME

WILLIAM & MARY CUSTODIAL TASK & FREQUENCY LIST. PUBLIC SPACE: ENTRANCES, LOBBIES, AND CORRIDORS Daily Weekly Monthly Quarterly Yearly

SPACE TYPES & REQUIREMENTS

Home Inventory Worksheet

Camden. Included Features. Prices are non-negotiable. Continued on Back ATTRACTIVE INTERIORS:

4.0 SERVICES AND SCHEDULE

1426 Hinman Ave Evanston, IL

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Estimate Form for Kitchen Design and Installation

SPECIFICATION MAZARIN 72 4 CABIN VERSION

DOWNTOWN SARASOTA WATERFRONT CONDO ON THE BAY

TERRACE VIEW APARTMENTS

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Laundry hamper (most models) Wall mounted/framed TV cabinet (Columbus) Cherry hardwood dresser top (Columbus) Pillow top mattress

Stairway Location for Optional Foundation Model

CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice.

Introducing... The Lake Country Series. 18 Wide Single Section Homes. ... our WIDEST single section homes! Canada. Proudly made in

TERRACE VIEW APARTMENTS

For details or to arrange a showing, call (800) or

BURLEIGH MANOR MIDDLE SCHOOL HOWARD COUNTY PUBLIC SCHOOL SYSTEM

Sudbury Kitchens DESIGN SURVEY

ATTACHMENT A - ITEM DETAIL

COSMETOLOGY September 30, 2010

25a Archer Road Penarth, Vale of Glamorgan, CF64 3HJ

Kitchen Planning Worksheet

TERRACE VIEW APARTMENTS

Visual Assessment of Cleanliness

VENTURA WAS VOTED ONE OF THE 10 BEST PLACES TO LIVE IN 2015

2169 Eagles Nest Rd. Waynesville, North Carolina Property Description & Features

Butte County Board of Supervisors Agenda Transmittal

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

03. FOOD: Unsealed, left in room, dirty lunch. 03. FOOD: Unsealed, left in room, dirty lunch. 03. FOOD: Unsealed, left in room, dirty lunch

Home Contents Inventory

Lighting Proposal Memo. Lighting Proposal. Angela Nudy Lighting/Electrical Dr. Mistrick Lighting Proposal Memo 1

Custodial- General Cleaning Duties

Planning Questionnaire

The Villas of Wyldewood

WATERLEFE GOLF & RIVER PARADISE

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

This Restaurant is ready to open.tomorrow

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

Proudly made in. Canada. to Canadian Standards. The CJ Series. 20 Wide Homes

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

Millard Refrigerated Services Monthly Health and Safety Observations

Columns REF, RESPONSIBLE and COMPL TD are provided for your numbering, assignments and control. REF ISSUE RESPONSIBLE COMPL TD

Columbia Single Section Homes

CONTEMPORARY DESIGN. MODERN LUXURY.

S P R I N G C L E A N I N G G U I D E

Sagecrest. LIVE All about you and how you live every day... Comfortable & Peace of Mind

Standard Features. ashbysbridge.com. Mobile: (757)

Transcription:

Leicester Fire Department July 27, 2009 33 Commercial Street, Suite 1

TABLE OF CONTENTS TABLE OF CONTENTS STAFFING AND PARKING I-1 SPACE ALLOCATION I-2 APPARATUS AND SUPPORT APPARATUS ROOM I-4 HAZMAT AND DISASTER SUPPLY STORAGE I-5 EQUIPMENT STORAGE I-6 FIREFIGHTER S TOILET I-7 DELUGE SHOWER I-8 AIR SUPPLY ROOM I-9 TURN-OUT GEAR ROOM I-10 CONTAMINATED WASHER EXTROR I-11 BIOHAZARD/DECON ROOM I-12 EMS STORAGE I-13 READY ROOM/BATTERY CHARGING I-14 PUBLIC LOBBY/DISPATCH WATCH ROOM I-15 PUBLIC LOBBY/VESTIBULE/RECEPTION I-16 PUBLIC TOILETS I-17 ADMINISTRATION FIRE CHIEF'S OFFICE I-18 DEPUTY FIRE CHIEF S OFFICE I-19 EMS COORDINATOR I-20 TRAINING OFFICER I-21 COMPANY OFFICER I-22 FIRE PREVENTION I-23 EMERGENCY MANAGER OFFICER I-24 CONFERENCE ROOM I-25 SPARE OFFICE I-26 ADMINISTRATIVE ASSISTANT I-27 SUPPLY ROOM I-28 ADMINISTRATIVE WORKROOM I-29 ADMINISTRATIVE TOILET ROOM I-30 ARCHIVES/DEAD RECORDS I-31 INDOOR TRAINING TRAINING EQUIPMENT STORAGE I-32 TRAINING ROOM (EOC) I-33 FITNESS I-34 Leicester Fire Department I-i 33 Commercial Street

TABLE OF CONTENTS FIREFIGHTER S QUARTERS FIREFIGHTERS' ROOMS I-35 MALE TOILET AND SHOWER I-36 FEMALE TOILET AND SHOWER I-37 MALE LOCKER ROOM I-38 FEMALE LOCKER ROOM I-39 DAY ROOM I-40 KITCHEN/DINING I-41 PANTRY I-42 BUILDING SUPPORT AND SYSTEMS JANITOR S CLOSET I-43 BUILDING SUPPLIES ROOM/STORAGE I-44 MAINTENANCE AND STORAGE I-45 MECHANICAL ROOM ELECTRICAL ROOM TELEPHONE ROOM Leicester Fire Department I-ii 33 Commercial Street

STAFFING AND PARKING Present Future Personnel, Day Shift Per Shift Total Per Shift Total Fire Chief 1 1 1 1 Deputy Fire Chief 1 1 1 1 Lieutenant 1 1 1 1 Company Officer 1 1 1 1 Firefighters (50 on call) 50 50 Firefighters (10 auxiliary) 10 10 Training Officer 1 1 1 1 Fire Prevention 1 1 1 1 EMS Coordinator 1 1 1 1 Emergency Management 1 1 1 1 Director Administrative 1 1 1 1 Total 9 69 9 69 Present Parking per Shift Future Parking per Shift Staff 2 20 Public 1 3 Site Features Provide space for dumpster, A/C condenser, emergency diesel generator (48 hour service for entire building), and communications tower. Interior Features All wall clocks interwired Multiple data and outlet locations in each room Leicester Fire Department I-1 33 Commercial Street

SPACE ALLOCATIONS ITEM PROPOSED SF 1 ST 2 ND APPARATUS AND SUPPORT APPARATUS ROOM I-4 6,400 HAZMAT AND DISASTER SUPPLY I-5 168 EQUIPMENT STORAGE I-6 168 FIREFIGHTER S TOILET I-7 50 DELUGE SHOWER I-8 36 AIR SUPPLY ROOM I-9 216 TURN-OUT GEAR ROOM I-10 250 CONTAMINATED WASHER EXTROR I-11 80 BIOHAZARD/DECON ROOM I-12 128 EMS STORAGE I-13 224 READY ROOM/BATTERY CHARGING I-14 36 SUB-TOTAL 7756 PUBLIC/LOBBY/DISPATCH WATCH ROOM I-15 180 PUBLIC LOBBY/VESTIBULE/RECEPTION I-16 216 PUBLIC TOILET I-17 270 SUB-TOTAL 666 ADMINISTRATION FIRE CHIEF S OFFICE I-18 224 DEPUTY FIRE CHIEF'S OFFICE I-19 168 EMS COORDINATOR I-20 176 TRAINING OFFICER I-21 140 COMPANY OFFICER I-22 160 FIRE PREVENTION I-23 248 EMERGENCY MANAGER OFFICER I-24 140 CONFERENCE ROOM I-25 150 SPARE OFFICE I-26 120 ADMINISTRATIVE ASSISTANT I-27 236 SUPPLY ROOM I-28 64 ADMINISTRATIVE WORK ROOM I-29 64 ADMINISTRATIVE TOILET ROOM I-30 126 ARCHIVE/DEAD STORAGE I-31 160 SUB-TOTAL 2176 INDOOR TRAINING TRAINING EQUIPMENT STORAGE I-32 80 TRAINING ROOM I-33 1000 FITNESS I-34 400 SUB-TOTAL 1480 FIREFIGHTER S QUARTERS FIREFIGHTER'S ROOMS (6) I-35 660 MALE TOILET AND SHOWER I-36 250 FEMALE TOILET AND SHOWER I-37 120 MALE LOCKER ROOM I-38 200 FEMALE LOCKER ROOM I-39 200 DAY ROOM I-40 260 Leicester Fire Department I-2 33 Commercial Street

SPACE ALLOCATIONS ITEM PROPOSED SF 1 ST 2 ND KITCHEN/DINING I-41 448 PANTRY I-42 120 SUB-TOTAL 2258 BUILDING SUPPORT AND SYSTEMS JANITOR S CLOSET I-43 72 BUILDING SUPPLIES ROOM/STORAGE I-44 120 MAINTENANCE AND STORAGE I-45 140 MECHANICAL ROOM 340 ELECTRICAL ROOM 120 TELEPHONE ROOM 80 SUB-TOTAL 862 SUBTOTAL 15,198 10364 4834 WALLS, CIRCULATION, STAIRS, CHASES 3800 2591 1209 @25% TOTAL GROSS FIRST FLOOR 12,955 TOTAL GROSS SECOND FLOOR 6043 TOTAL BUILDING GROSS 18,998 Leicester Fire Department I-3 33 Commercial Street

APPARATUS AND SUPPORT APPARATUS ROOM 4 bays @ 20' x 80' = 6,400 SF Adjacent to firefighters' quarters and to support spaces Controlled by public lobby Moderate Eye wash, area for printer and radio charging (Ready Room) HEADQUARTERS FRONT LINE RESPONSE 1 Pumper @ 38' 1 Brush @ 38' 1 Ladder @ 45' 1 Rescue Truck 2 Ambulance 1 SUV HEADQUARTERS RESERVE RESPONSE 1 Engine 1 Hazmat Trailer Electric cord reel. Overhead doors 14' x 14', overhead power, overhead water fill, compressed air. Overhead door operations: At door jamb, at office, and on apparatus vehicles. Wide trench drains. Mop sink Acoustic considerations Sand/oil separator Heavy-duty overhead door operators Zetron speakers/lights Ice Maker Hardener and sealer concrete slab CMU with epoxy paint Painted exposed/ Low-level night lighting, fluorescent rapidresponse No A/C, provide vehicle exhaust system, ceiling fans Leicester Fire Department I-4 33 Commercial Street

APPARATUS AND SUPPORT HAZMAT AND DISASTER SUPPLY STORAGE 12' x 14' = 168 SF Off apparatus floor Moderate 2'-0" deep shelves, 12" apart on 3 walls Sealed concrete CMU - epoxy paint Exposed Structure/ Fluorescent No A/C Leicester Fire Department I-5 33 Commercial Street

APPARATUS AND SUPPORT EQUIPMENT STORAGE 12' x 14' = 168 SF Next to apparatus room Moderate Storage for hand tools, ropes, water pumps, portable generator, ice sled, 2 rows of 18" deep metal mesh shelving on one wall Concrete with hardener CMU-epoxy paint Painted exposed structure/ Fluorescent No A/C Leicester Fire Department I-6 33 Commercial Street

APPARATUS AND SUPPORT PARTS STORAGE 12' x 14' = 168 SF Next to apparatus room Moderate Storage for parts and minor repairs. 4 rows of 24" deep metal mesh shelving on one wall. 8 Work bench Concrete with hardener CMU-epoxy paint Painted exposed structure/ Fluorescent No A/C Leicester Fire Department I-7 33 Commercial Street

APPARATUS AND SUPPORT HOSE STORAGE ROOM FLOOR AREA EXISTING 12' x 16' = 192 SF Next to apparatus floor Moderate Wall mounted hose racks on three walls Floor drain Concrete CMU epoxy paint Exposed Structure Fluorescent No A/C - mechanical ventilation Leicester Fire Department I-8 33 Commercial Street

APPARATUS AND SUPPORT FIREFIGHTER S TOILETS Male and female (2 @ 50 SF) 100 SF Next to apparatus room and gear room Each toilet room to have1 toilet, 1 sink Zetron speakers Ceramic tile CMU with ceramic tile wainscot Fluorescent A/C, good ventilation Leicester Fire Department I-9 33 Commercial Street

APPARATUS AND SUPPORT AIR SUPPLY ROOM 12' x 18' = 216 SF Off of apparatus room High Rack for storage of air tanks, 6' long workbench, tool storage, SCBA air tanks, SCBA compressor 4' x 10' Zetron speakers Concrete with hardener CMU Fluorescent No A/C, good ventilation Leicester Fire Department I-10 33 Commercial Street

APPARATUS AND SUPPORT TURN-OUT GEAR ROOM 10 SF for each locker (25) = 250 SF Next to apparatus room Moderate 25 steel mesh cubicles 24" x 24" with top and bottom shelves Zetron speakers Zetron speakers Floor drains Electrical outlets in each cubicle Concrete with hardener/or rubber flooring CMU with epoxy paint No fluorescent light fixtures No A/C, very good ventilation Maintain gear room under negative pressure Leicester Fire Department I-11 33 Commercial Street

APPARATUS AND SUPPORT CONTAMINATED WASHER/DRYER 8' x 10' = 80 SF Near turn-out gear room and Decontamination Room Heavy-duty, stainless steel, 45 lb. capacity washer extractor and dehydrator with shelving above Floor drain Thickened floor slab Gravity drain from extractor with air gap Concrete with hardener/ or rubber flooring CMU Fluorescent No A/C, good ventilation, dryer vent Leicester Fire Department I-12 33 Commercial Street

APPARATUS AND SUPPORT BIOHAZARD/DECON ROOM 8' x 16' = 128 SF Accessible from the exterior and the apparatus bay High 5 x 5 deluge shower with eye wash, 3' x 3' floor sink, hose with spray, wall-mounted stainless steel sink with foot controls. Zetron speakers Ceramic tile CMU with ceramic tile wainscot Fluorescent Good ventilation Leicester Fire Department I-13 33 Commercial Street

APPARATUS AND SUPPORT EMS STORAGE 14' x 16' = 224 SF With a built-in 18 SF drug locker Near apparatus room High 12" metal shelving, spaced at 12" apart on three sides of room Sealed concrete CMU Fluorescent Good ventilation, A/C Leicester Fire Department I-14 33 Commercial Street

APPARATUS AND SUPPORT BATTERY CHARGING 3' x 12' = 36 SF Alcove adjacent to Apparatus Room Moderate Counter with storage cabinets and shelving Electrical wire mold outlets and data jackets Sealed concrete. CMU Task lighting No A/C Leicester Fire Department I-15 33 Commercial Street

PUBLIC LOBBY/DISPATCH WATCH ROOM 180 SF Direct view to Public/Lobby entrance, view into Apparatus Room, adjacent to First Aid Triage High Radio console position for one 8' work, 2 chairs, wall space for maps, counter with storage for forms under at window to Public Lobby, 20 LF shelving, white board, cable TV. Window with pass-through and counter to Public Lobby/Reception Controls for VOC- ALARM or ZETRON. CCTV Room darkening shades. Desk space for report writing. Carpet tile Fluorescent with parabolic reflector, 2 level lighting, task lighting A/C Leicester Fire Department I-16 33 Commercial Street

PUBLIC LOBBY/DISPATCH PUBLIC LOBBY/VESTIBULE/RECEPTION 12' x 14' = 168 SF Next to Watch Room; near Administrative area. Easy, but not visible access to Admin. Speakthru and paper slot to Watch Room. Full access Moderate; controlled exit from Lobby to the rest of the building. All public must check in w/ Watch Officer first. Surveillance from Watch Room, automatic door operators Porcelain pavers Fluorescent plus accept lighting A/C Leicester Fire Department I-17 33 Commercial Street

PUBLIC LOBBY/DISPATCH PUBLIC TOILETS Male and female 190 SF Access from Public Lobby and adjacent to the training room High Male - 1 toilet, 1 sink, 1 urinal, Female - 1 toilet, 1 sink, Handicapped accessible Floor drain Ceramic tile CMU with ceramic tile wainscot Fluorescent A/C, good ventilation Leicester Fire Department I-18 33 Commercial Street

ADMINISTRATION FIRE CHIEF S OFFICE 12' x 16' = 192 SF Near Administrative Secretary's office Limited, controlled 30" x 6' desk with return and credenza, desk chair, with 4 file lateral file drawers, seating for 4 at small conference table, wall-mounted TV/VCR and 30 LF bookshelves White board Zetron Speakers Closet 2 x 4 Carpet Fluorescent with parabolic reflector A/C Leicester Fire Department I-19 33 Commercial Street

ADMINISTRATION DEPUTY FIRE CHIEF S OFFICE 12' x 14' = 168 SF Near Administrative Secretary's office Limited, controlled 30" x 6' desk with return and credenza, desk chair, with 2 file lateral file drawers, wallmounted TV/VCR and 30 LF bookshelves White board Zetron Speakers Closet 2 x 4 Carpet Fluorescent with parabolic reflector A/C Leicester Fire Department I-20 33 Commercial Street

ADMINISTRATION EMS COORDINATOR 12' x 14' = 168 SF Near Secretary's office Limited, controlled 30" x 6' desk with return and credenza, desk chair, with 2 file lateral file drawers, TV/VCR Closet with adjustable metal shelving Zetron speakers Closet 2 x 4 Carpet Fluorescent with parabolic reflector A/C Leicester Fire Department I-21 33 Commercial Street

ADMINISTRATION TRAINING OFFICE : Office 14' x 10' = 140 SF Near administrative staff Limited Moderate Desk with return and desk chair, 2 guest chair, (2) 3-drawer lateral files, 20 LF shelving Zetron speakers Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-22 33 Commercial Street

ADMINISTRATION COMPANY OFFICER/ LIEUTENANT Separate room to house 2 cubicles @ 8' x 10' = 160 SF Near secretary and Fire Chief's office Direct access to fire fighters area/apparatus bay Limited, controlled Each cubicle to house (1) 30" x 6' desk and return, 1 desk chair, 1 guest chair, 4 LF book shelves, (1) 3' storage cabinets, (1) 3-drawer lateral files with top Zetron speakers Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-23 33 Commercial Street

ADMINISTRATION FIRE PREVENTION OFFICE OFFICE @ 120 SF = 120 SF Plan storage @ 48 SF = 48 SF Work space @ 100 SF = 100 SF 268 SF TOTAL Plan storage and work room to be separate room Near administrative staff Limited Moderate desk with return and desk chair, 2 guest chairs, (3) 3-drawer lateral files, 10 LF shelving, plan review table, flat files for archived plans, roll storage for current plans Space for printer Zetron speakers Multiple data and outlets Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-24 33 Commercial Street

ADMINISTRATION EMERGENCY MANAGER OFFICE 10' x 14' = 140 SF Near administrative staff Limited, controlled (1) 30" x 6' desk, 1 desk chairs, 2 guest chairs, 40 LF book shelves, (2) 3' storage cabinets, (2) 3-drawer lateral files with top. Zetron speakers Closet 2 x 4 Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-25 33 Commercial Street

ADMINISTRATION EMERGENCY MANAGER STORAGE 10' x 14' = 140 SF Near Emergency Management Office Limited, controlled 5 rows of 24 deep shelving on one side Zetron speakers Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-26 33 Commercial Street

ADMINISTRATION CONFERENCE ROOM 25 SF per person (15 x 25 = 375 SF) Adjacent to Chief's and Deputy Fire Chief's Office Controlled Moderate Table and chairs to accommodate 16, credenza 6' white board, tackable surface Overhead projection screen, cable, phone and electrical connections set in conference table Carpet Fluorescent with parabolic reflectors, downlights A/C Leicester Fire Department I-27 33 Commercial Street

ADMINISTRATION STORAGE 12' x 10' = 120 SF Adjacent to Reception area Limited, controlled Carpet Fluorescent with parabolic reflections A/C Leicester Fire Department I-28 33 Commercial Street

ADMINISTRATION ADMINISTRATIVE ASSISTANT Open Office area 12' x 14' = 168 Waiting area 10' x 6' = 60 Closet 2' x 3' = 6 TOTAL SF 236 Near Chief, Public Lobby Limited controlled High 1 desk with returns, 1 desk chairs, 20 LF shelving; require 6-36" 4-drawer laterals - for active files Waiting area to have 4 chairs and a counter for filling out forms Office area to be separated from waiting area with a low wall and counter Coat closet Carpet Fluorescent with parabolic reflectors A/C Leicester Fire Department I-29 33 Commercial Street

ADMINISTRATION SUPPLY ROOM 8' x 8' = 64 SF Adjacent to Administrative Workroom Moderate 4 rows of 24" adjustable metal shelving on two walls Zetron speakers VCT Fluorescent with parabolic reflections A/C Leicester Fire Department I-30 33 Commercial Street

ADMINISTRATION ADMINISTRATIVE WORKROOM 8' x 8' = 64 SF Adjacent to Administrative Assistant Limited Copier, fax, printer, laminator, scanner, shredder, 30 LF of shelves. Cable data outlets. Zetron speakers VCT Fluorescent with parabolic reflector A/C Leicester Fire Department I-31 33 Commercial Street

ADMINISTRATION SERVER CLOSET 10' x 10' = 100 SF Adjacent to offices High Computer file server, monitor and keyboard on work counter VCT Fluorescent with parabolic reflectors A/C Leicester Fire Department I-32 33 Commercial Street

ADMINISTRATION ADMINISTRATIVE TOILET ROOMS 2 @ 9' x 7' = 126 SF Within Administrative area adjacent to break room Moderate Toilet and sink for each sex Handicapped accessible Floor drain Ceramic tile Ceramic tile wainscot Fluorescent A/C, good exhaust tied to light switch Leicester Fire Department I-33 33 Commercial Street

ADMINISTRATION ARCHIVES/DEAD RECORDS 16 SF per lateral file (16' x 10' = 160 SF) Moderate 10 4-drawer lateral file cabinets or mobile shelving Sealed concrete Fluorescent A/C Leicester Fire Department I-34 33 Commercial Street

INDOOR TRAINING TRAINING EQUIPMENT STORAGE 12' x 12' = 144 SF Access from training room High Shelving, 1½' deep for the storage of training equipment; VCR, TV monitor, slide projector, training tapes, CPR training equipment such as mannequins. Area to store tables and chairs. Carpet Fluorescent No A/C Leicester Fire Department I-35 33 Commercial Street

INDOOR TRAINING TRAINING ROOM 50 people @ 20 SF/person = 1000 SF Accessible from lobby and adjacent to Training Equipment Storage Possibly Moderate Table and chairs to accommodate 50; podium, stand with wheels for VCR, video monitor, and video and slide projectors. White board, fabric covered tackable surfaces. Room darkening shades. Cable data outlets. Room dividing partition to separate room into two. Alcove for coffee prep to include small refrigerator, microwave, sink, coffeemaker, and cabinets above. Zetron speakers Sound control to adjacent spaces Exterior access Carpet Fluorescent, glare-free; dimmers, or incandescent with dimmers A/C with good exhaust system Leicester Fire Department I-36 33 Commercial Street

INDOOR TRAINING FITNESS STAFF All 400 SF Direct access to showers Moderate Treadmills, stationary bicycles, universal weight, machine and free weights. Equipment will be furnished with FF&E. Zetron speakers Clock, wall-mounted TV, cable mirrored wall. Sport flooring on concrete slab, sound insulation Fluorescent A/C, good ventilation, separate control Leicester Fire Department I-37 33 Commercial Street

FIREFIGHTER'S QUARTERS FIREFIGHTER'S ROOMS Double bedrooms, 2 @ 10' x 11' = 220 SF Single bedrooms, 4 @ 10' x 8' = 320 SF Total = 540 SF Good access to Apparatus Room Adjacent to toilet rooms and Day Room Moderate Each single room to have a chair, extra long twin bed with under bed storage, small built-in desk. Each double room to have two chairs, two extra long twin bed with under bed storage, and two small built-in desk. Provide 2 power, 2 data and 2 cable TV outlets on all walls. Room darkening shades. Zetron speakers Sound attenuation in walls Carpet Fluorescent, 2 light levels Task lighting A/C Leicester Fire Department I-38 33 Commercial Street

FIREFIGHTER'S QUARTERS TOILET & SHOWER ROOMS 4 Private toilet rooms @ 54 = 216 SF Near Firefighters Rooms Direct access to Locker Room near Sleeping Quarters Moderate sink, toilet, showers with drying area. Toilet room does not need to be handicap accessible. 1 full-length mirror, Zetron speakers. Ceramic tile with ceramic wainscoting Fluorescent A/C Leicester Fire Department I-39 33 Commercial Street

FIREFIGHTER'S QUARTERS LOCKER ROOM 11 sf per locker x 36 = 396 SF Open locker area accessible to both male and females. Direct access to fitness room and showers Moderate One 18" x 18" locker per person (36 Lockers), wood bench Zetron speakers Full length mirror VCT/rubber Fluorescent A/C, good ventilation Leicester Fire Department I-40 33 Commercial Street

FIREFIGHTER'S QUARTERS STUDY ROOM 12' x 10' = 120 SF Near living quarters Moderate Built-in countertop for computer use, along one wall. Two chairs, 60 LF of shelving. Data/ computer outlets. Zetron speakers Carpet Fluorescent A/C Leicester Fire Department I-41 33 Commercial Street

FIREFIGHTER'S QUARTERS DAY ROOM 480 SF Good access to Apparatus Room open plan with Kitchen/Dining Moderate Recliners, couch and seating for 12. Table and chairs for four. Provide power and cable TV outlets on all walls. Zetron speakers Carpet Fluorescent with parabolic reflectors, multiple TV jacks, task A/C Fluorescent with parabolic reflectors, multiple TV jacks, task A/C Leicester Fire Department I-42 33 Commercial Street

FIREFIGHTER'S QUARTERS KITCHEN/DINING Kitchen 16 x 14 = 224 SF Dining 18 x 22 = 396 SF TOTAL = 620 SF Near Day Room Moderate High end Residential appliances; 20 cf refrigerator 20 cf freezer 6 burner range with oven and hood, microwave, large deep sink, dishwasher, garbage disposal, water tap at range, solid-surface countertop, tables to accommodate 20 plumbed coffeemaker Zetron speakers Ceramic tile, quarry tile Fluorescent A/C, range exhaust Leicester Fire Department I-43 33 Commercial Street

FIREFIGHTER'S QUARTERS PANTRY 10' x 10' = 100 SF Alcove off of Kitchen Moderate (4) 24" x 24" lockable storage closets, 1 soda machine, 50-lb. ice maker. Space for recycling Ceramic tile, quarry tile Fluorescent A/C Leicester Fire Department I-44 33 Commercial Street

BUILDING SUPPORT AND SYSTEMS JANITOR S CLOSETS (1 on each area) @ 6' x 6' = 36 SF 36 x 2 = 72 SF TOTAL Centrally located Moderate Floor sink, mop racks, shelving Ceramic tile with ceramic tile wainscoting Fluorescent No A/C Leicester Fire Department I-45 33 Commercial Street

BUILDING SUPPORT AND SYSTEMS BUILDING SUPPLIES ROOM/STORAGE 18' x 14' = 252 SF Moderate Three rows of adjustable 24" deep shelves on two and walls and 12" deep shelves on one wall VCT Fluorescent No A/C Leicester Fire Department I-46 33 Commercial Street

BUILDING SUPPORT AND SYSTEMS MAINTENANCE & STORAGE 10' x 12' maintenance, 120 SF First floor, good access to exterior and Apparatus Room Moderate 6' workbench with stool and tool rack above, 30 LF shelving Concrete with hardener CMU or exposed Fluorescent No A/C, ventilation Leicester Fire Department I-47 33 Commercial Street

BUILDING SUPPORT AND MECHANICAL Leicester Fire Department I-48 33 Commercial Street