Isolated Power Systems Equipment

Similar documents
T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

MK Series. Remote Indicators For Line Isolation Monitors and Fault Location. Technical Bulletin NAE /

Isolated Power Panels Line Isolation Monitor (LIM) Remote Indicators/Displays Accessories 15-6

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Line Isolation Monitor (LIM) LIM2000plus

ISOLATED POWER ACCESSORIES

Isolated Power Panels Duplex Panels Surgical Facility Panels Dual Output Voltage Panels Accessories 16-6

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Line Isolation Monitor LIM2000plus Confirms the Integrity of Isolated Power Systems

Remote alarm indicator and test combination MK2430

T M. User Manual LIM2010. Line Isolation Monitor

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

IntesisBox BACnet/IP Server - Notifier ID3000 series

Spectron LSN (Life Safety Network) Suggested Specifications

Data Bulletin. Hospital Isolated Power Systems. Dual Output Voltage Isolation. Class 4817 INTRODUCTION

1.7. Insulation fault evaluators EDS460/490 EDS461/491

LORAIN CIP 4890/48120 DC Power System

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

NU2 Smart Power Supply (SPS) Manual

APPLICATION DATA SHEET

SECTION ISOLATED POWER SYSTEMS

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

CMD420 / CMD421 Series

LORAIN CSP DC Power System

AIS750 Series Alarm Annunciator

16 Zone Voice Evacuation VA & PA Sound System

SECTION POWER SUPPLIES AND DISTRIBUTION

RACK MONITORING SYSTEM - RAMOS Ultra

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

SIMPLICITY BY DESIGN M52 CONTROLLER

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Specification Data. General:

Across-the-Line SERIES MP300 Combined Manual and Automatic

THX-DL Data Logger USER & INSTALLATION MANUAL V

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DGC-500 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER

RACK MONITORING SYSTEM RAMOS Ultra

ID2000. intelligent fire alarm panel

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

SECTION NURSE CALL SYSTEM

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Galaxy Pulsar Plus Digital Battery Plant Controller

Soft Start Series MP700 Solid State, Reduced Voltage

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Product overview. Alarm indicator, operator and display panels

N-8000 SERIES IP INTERCOM SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

APPLICATION DATA SHEET

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

FG Wilson Control Systems

Added password for IP setup page : Password must be in IP format!

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

SECTION LIGHTING CONTROLS

Variable Frequency Drive SERIES MP800 VFD

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

Vocia VACIE. Reference Guide

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

VACIE REFERENCE GUIDE REVISION 1.2.6

ENGINE GENERATORS AND ACCESSORIES

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Model A1600 Series Annunciator

PowerWizard Range. Digital Control Systems & Remote Communication Options.

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

For Complete Fire and Gas Solutions

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

APC BC300 Series 40kW 208/450/480V User Guide

CHAPTER 20 SERVICE EQUIPMENT

Panel Mounted Fault Annunciator Series

Networked Access Control Panel. Installation Guide

Healthy. Atmosphere. for Pigs and Poultry. for a

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

_5120_School_Intercom_Rack_Spec.doc 09/21/04

1.1 Remote Annunciator Controller (RAC) and 1 Switch (ATC-600/800) via Modbus TCP/IP Ethernet Gateway

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Touchpoint Pro Flexible Gas Control System

Med Touch Master Alarm

IT system floor-standing distribution

INSTALLATION GUIDE

Flair 500 Series Annunciators

PUMP CONTROL CENTER (PCC)

GasGard 100 Control System

Upright Chromatography Refrigerators

USER MANUAL FOR OPERATING SYSTEM

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

DETECTION TECHNOLOGY

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Universal fault annunciator for panel mounting

Transcription:

2 Isolated Power Systems Equipment For Hospitals and Critical Care Areas Brochure NAE2091010 / 10.2012

BENDER Isolated Power System Equipment Isolated Power System with Line Isolation Monitor for hospitals and other critical care areas Isolated Power Systems Isolated power systems offer an invaluable advantage: Early detection allows for critical systems to remain online in a single fault condition. BENDER Isolated Power Panels provide isolated power to electrical systems in operating rooms and other critical care areas. Utilizing the latest in line isolation monitoring technology, the LIM2010 provides advanced warning of faults to help reduce downtime and increase operational efficiencies. BENDER isolated power system equipment are designed in strict compliance with UL 1047, UL 1022, and UL 50. LIM2010 Line Isolation Monitor No interference with electrical equipment Digital display showing THC in real-time Automatic self-calibration and self-check Audible and visual alarm indicators Many optional alarms, including load monitoring, over and under voltage, temperature monitoring, and more RS-485 communication interface Compatible with BENDER s advanced communication bus with several distribution options, including web-based viewing Compatible with BENDER s ground fault location system (EDS) LIM2010 Line Isolation Monitor Ground Fault Location Module The EDS491/EDS461 series of ground fault location modules, combined with the LIM2010, create an installed ground fault location system for ungrounded AC and DC systems. Once a ground fault is detected, the test pulse generated by the LIM2010 is scanned by the EDS491/EDS461 to locate a ground fault down to the load level. Up to 12 separate current transformers may be connected to the device. A total of 90 EDS devices may be interconnected via RS-485. By utilizing the EDS series devices, the source of the fault in the isolated power system can be identified within seconds. EDS491-D-2 5 Year Warranty* on BENDER Isolated Power Panels and Line Isolation Monitors *Note: 5 year warranty is issued when an initial startup checkout is performed by a Manufacturer Authorized Technician 2

A complete ground fault location system TCP/IP Modbus/TCP OPC Server Router WiFi Modbus/TCP OPC Modbus/TCP SCADA / BMS Modbus/TCP TCP/IP/Ethernet Ethernet Modbus/TCP COM460IP Line Isolation Monitor LIM2010 GF Location Module EDS Series Power Supply Class 2 > F L1 L2 MK2430 MK2000 Series Ethernet and Modbus/TCP Communication Modules The COM460IP is a full-featured communication gateway for connecting BENDER devices to modern networks. The COM460IP connects via Ethernet connections to an existing communication network. The integrated web server displays the status of the entire network of BENDER devices, and may be viewed through the web browser (with Silverlight plugin installed) of any connected PC. No additional software is required. The COM460IP has many customizable options, including the ability to act as a Modbus/TCP gateway for status information. Features Modular, expandable gateway between BENDER communication bus and TCP/IP Gateway between BENDER communications bus and Ethernet Optional Modular/TCP communication gateway for status information of BENDER devices Customizable features available through options Capability for remote access via LAN, WAN, and Internet COM460IP 3

Isolated Power Panels General Information: A complete Isolated Power Panel is typically comprised of four assembly types : Interior, Hospital grade transformers, Backbox (enclosure ) and Front trim Isolated Power Panels BENDER s standard hospital panel provides isolated power service and protection to operating rooms and other critical care areas. The panel includes: Isolation transformer, rated to your requirements Primary circuit breaker Eight (8) 2-pole circuit breakers, field expandable to 16 LIM2010 Line Isolation Monitor Compatible with BENDER s EDS ground fault location system Isolated Power Panels with Receptacles and Ground Jacks Including all of the features of standard panels, BENDER isolated power panels may also be provided with a section for hospital grade power receptacles and/or ground jacks. This panel configuration is ideally suited for having a centralized location for receptacles and ground jacks. BENDER type HGC hospital grade ground cords are recommended for use with this configuration. See accessories for more information. Isolated Power Panels for X-Ray / Laser Equipment Isolated power panels may also be configured to feed x-ray and laser equipment at intervals up to 60 A (within the power rating of the panel). Panels are controlled by means of a PLC. This control may be customized to meet a particular system s requirements. BENDER type XRM receptacles modules are recommended for use with this panel configuration. See accessories for more information. 4

Isolated Power Panels Dual Voltage Isolated Power Panels BENDER s dual voltage isolated power panels provide two different output voltages simultaneously using one isolation transformer. The typical configuration is provided with one side configured for 208 V or 240 V fixed at 15 kva and the second side configured for 120 V at 5, 7.5, or 10 kva. Ideally suited for: Locations where space is limited Installations requiring power for both typical hospital equipment and x-ray / laser receptacles Dual System Isolated Power Panels BENDER dual system isolated power panels contain two complete isolated power systems. Both sides are independently configurable. Ideally suited for: Locations where space is limited Renovations Surgical Facility Centers BENDER s custom designed surgical facility centers combine many key operating room components into one isolated power solution. Surgical facility centers provide isolated power protection while minimizing footprint and standardizing individual components required in the operating room. Surgical facility centers typically include, but are not limited to: Surgical clock/timer Receptacle and/or ground jacks Film illiminators or Dry Erase Boards Audio system with speakers 5

Remote Indication MK2000 Series LIM Remote Indicator MK Series remote indicators are designed for use with the BENDER LIM2010 Line Isolation Monitor. A remote indicator duplicates audible and visual alarm indications on the LIM. All remote indicators include a green SAFE LED, a red HAZARD LED, and a MUTE button with an integral amber LED. The MUTE button is used to silence the remote audible alarm. Optionally, it can also be used to silence all audible alarms in the system. MK2000P-G1 (left) & MK2000 CBM (right) Models with additional features include: MK2000P: Test button MK2000C: Amber OVERLOAD * alarm LED MK2000CP: Amber OVERLOAD * alarm LED and test button MK2000CBM: Amber OVERLOAD * alarm LED, test button, and digital displays showing THC reading and % isolation transformer load* in real-time RAS Remote Annunciator Station RAS series remote annunciator stations utilize multiple MK series remote indicators, each connected to a line isolation monitor. Included remote indicators may feature a built-in test button and a transformer overload* LED. Each remote indicator is powered directly by the LIM2010 line isolation monitor, located at the isolated power panel. RAS-04B Advanced MK Series Remote Indicators The universal remote alarm indicators and operator panels MK2430/MK800 are intended for visual and audible indication of operating status and alarm messages from BENDER systems including the LIM2010 and EDS series ground fault location evaluators. The MK2430/MK800 displays information regarding each individual device, system, or room and can define custom labels based on each individual application. A LIM test may also be preferred from these devices. MK2430 (left) & MK800 (right) Alarm and Display Features: Status and alarms are viewed on an easy-to-read LCD display. Features include: Normal operation indicator (green LED) Connection monitoring alarms Total hazard current Device errors Overload* Test results Over-temperature Measured values Location of fault from EDS device Audible and visual indication During normal operation, the MK2430/MK800 indicates the overall status of the system. The MK2430-11 features 12 digital inputs allowing messages from other technical equipment to be recorded and displayed. * Note: Overload feature requires the use of BENDER STW series CTs installed in the Isolated Power Panel 6

Clocks, Timers, & Communication Solutions Dual Display Digital Clock and Timer The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both the time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required. ZT1590RS (left) & MK1550 (right) Digital Clock or Timer ZT1591 The Clock/Elapsed timers are complete microprocessor based units that display either time of day or elapsed time information. The ZT1591 has a large 2-1/2 7 segment display with large bright red LED characters that are easily read in high ambient light. The BENDER ZT1591 operates independent of line frequency. This unit has unique power backup systems that requires no battery so there is no need for battery monitoring and replacement. In the event of power outage, both clock and timer functions will continue to work for at least 24 hours. However, the displays are not visible during this time interval. The Timer may be activated from the remote control MK1550 or an external contact (code blue or other monitoring output). A count may be interrupted, resumed and reset at the remote control MK1550. Surgical Chronometer The ZT1594 surgical chronometer is a complete, microprocessor based system that displays time of day and three elapsed times. The system has four sevensegment displays with large, red LED characters easily read in high ambient light. All features, as well as device setup, are carried out on the connected MK1554 chronometer remote. ZT1594 7

Isolated Power Systems Equipment and Accessories GPM Series-Power and Ground Modules BENDER power and ground modules provide a combination of hospital grade power receptacles and/or hospital grade ground jacks. Straight-blade single, straight-blade duplex, and twist-to-lock receptacles can be provided in a wide array of combinations. Also available are hospital grade ground jacks to facilitate implementation of an equal-potential environment. Modules are provided on either stainless steel wall plates compatible with standard contractor supplied electrical gang boxes or stainless steel cover plates (as shown on the right) for use with ROHS compliant galvanized steel backboxes. GPM-F4DR4 HGC Series-Hospital Grade Ground Cords and Jacks BENDER hospital grade ground cords are available in various lengths for implementing an equal-potential environment. Cords are highly flexible and available with either a heavy duty clip or lug on one end, and plug with rubber handle on the other. HGC-15C (left) & HGJ-1R (right) XRM Series-X-Ray/Laser Receptacle Modules Used in conjunction with circuit-controlling isolated power panels, XRM series modules provide a convenient source of power for portable x-ray and laser equipment. Typical configurations include an x-ray or laser power receptacle matching the NEMA plug configuration of the equipment. An in-use lamp and magnetic door switch ensure that the proper amounts of circuits are online simultaneously. The MK series LIM remote indicator may also be built into the module for displaying the status of the connected LIM. North American Headquarters Coatesville, PA Toll-Free: 800-356-4266 Main: 610-383-9200 Fax: 610-383-7100 E-mail: info@bender.org T M bender.org bender.org/mobile XRM-8B2 Canada Mississauga, ON Toll-Free: 800-243-2438 Main: 905-602-9990 Fax: 905-602-9960 E-mail: info@bender-ca.com Document NAE2091010 / 10.2012 / Bender Inc.