BALANCED FLOW METER PLATE APPLICATIONS

Similar documents
Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Chapter 8. Production of Power from Heat

"HC" AIRFLO. In-duct firing line burner

Amec Foster Wheeler- Fired Heater Division

Simsite. Impellers and Wear Rings. Improve Longevity & Performance with Simsite Products!

Energy recovery from exhaust gases using Heat Pipe technology

Silhouette. Feedwater Heater. Boiler Feedwater

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Introduction to Control Technology

PIPING SYSTEM EQUIPMENTS

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Vacuum and Compressor Systems for the Chemical Process Industry

Chapter 10 VAPOR AND COMBINED POWER CYCLES

APPLICATION REPORT Isomerisation This diagram is intended to be a representation and should not be viewed as an actual process flow diagram.

Brazed Plate Heat Exchanger

Strategies in Optimizing Condensate Return

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Feed Interruption Three separate incidents within Marathon petroleum. p Garyville 2005, 05 Coker Unit - Feed interruption/furnace tripped caused by wa

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

MPI Providing challenging ultrasonic solutions

BORSIG WASTE HEAT BOILERS FOR NITRIC ACID, CAPROLACTAM AND FORMALDEHYDE PLANTS PROCESS HEAT EXCHANGER. A Member of KNM Group Berhad

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

MaxiCoking Technology Breakthrough Technology for Improved Existing Delayed Coker Performance

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy

Burners Flares Incinerators Vapor Combustion

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Refinery Vacuum Towers. State of the Art. (Extended Abstract)

Prepared by Technical Team

Efficient Steam System Design

CONTENTS. B. System Design and Performance Requirements

CHAPTER 3 BASIC STEAM CYCLE

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

Numerical Standards Listing

Brazed Plate Heat Exchanger

Numerical Standards Listing

Evaporators. Direct Expansion Flooded Recirculated Over Feed

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Spray Rinse & Steam Handling

New generation heat exchanger improves industrial energy efficiency

Homework Chapter2. Homework Chapter3

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Short Course: Fundamentals of Edible Oil Processing and Refining. Recent Developments. Ken Carlson RBD Technologies, Inc.

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

Manhardt Lindel / ERHARD-Armaturen VALVE & PIPELINE CAVITATION

Industrial. Solutions brands you trust. Product Overview

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

What is a Secondary Pressure Drainer?

STEAM SYSTEMS TOP SAFETY ITEMS FOR STEAM OPERATIONS. July, 2018

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

CORNELL PUMP COMPANY REFRIGERATION EFFICIENT BY DESIGN

SULPHUR RECOVERY UNIT

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

HEAT EXCHANGE INSTITUTE, INC.

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

Chapter 2.3: Steam System

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

Numerical Standards Listing

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Tel: Fax: Website:

STATIC MIXERS STATIC MIXING HEAT EXCHANGERS EJECTORS IN-LINE HEATER IN-TANK HEATER JET MIXING EDUCTOR DESUPERHEATER

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Technical Publication. Monitor Your Pump for Process Efficiency By Jim Delee, Sr. Member Technical Staff, Fluid Components International

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Contact Information. Steven Potratz, P.E. WSU Facilities Services, Engineering Services Manager Phone

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd.

The Expertise for Components

Conveyor and Batch Reflow Ovens

Products & Application

COOPERATIVE PATENT CLASSIFICATION

Multifunction pump for handling gaseous liquids in process engineering

2007 KBC Advanced Technologies plc. All Rights Reserved.

Series 1140 and 1141 Temperature Regulators

TECHNICAL. Series 18. Pump Packages

So far 2010 is proving to be

Technical Development Program

Heavy Duty Process Pumps API 610/ISO 13709

Week 13 Chapter 10 Vapor & Combined Power Cycles

IN THE MARINE INDUSTRY

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Thermal Devices, Inc. Mount Airy, Maryland USA

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Top performance when the going gets tough

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Falling-film evaporators.

Transcription:

BFM BALANCED FLOW METER NASA Invention of the Year PLATE APPLICATIONS

A+ Multi-Holed Balance Flow Meter (BFM) and Balanced-RO (BRO) Benefits: Flow Error < 0.25% Repeatability Error < 0.1% < 1 D Upstream and Downstream Fitting Requirements Uniform Pipe Velocity and Pressure Profiles No Harmful Eddies and Vibrations Designed for Single or 2-Phase Flows Thick Plate to Handle dp Stresses and Longer Life Over 10x Life of Single-Holed Thin Plate Higher Tolerance to Erosion and Cavitation Each Plate Custom Designed for Your Unique Process 10x Reduction in Noise Power Plate Noise <85 db with Patented Hole Designs High Hole Mach Numbers Pipe Erosion Virtually Eliminated Rugged and Durable Compared To Thin Plates Self Draining or Venting Plate Design Lower Pipe Noise, Thrusts and Vibrations Robust Mechanical Design, Can Be Designed To Handle Hydraulic Transients/Hammer Any Materials Thousands of Successful Applications

SN40000000 NASA / MSFC Marshall Space Flight Center Application: Liquid oxygen sample plate

SN40150003 18 inch, 0.25 thick, Beta 0.568150 Application: Off-gas with fouling

SN42260001 3 inch, 100mm thick, Beta 0.814700 Application: Saturated liquid hydrocarbons

SN50410001 6 inch, 6.00 thick, Beta 0.670500 Application: High viscosity polymer melt

SN50410002 6 inch, 0.25 thick, Beta 0.752400 Application: Chilled cooling water loop and silencer

SN51380001-2 8 inch, 0.25 thick, Beta 0.593 Application: Refinery hydrocarbon liquid

SN52420002 12 inch, 0.375 thick, Beta 0.85, RMS Application: Medium pressure steam

SN53620003 3 inch, 0.25 thick, Beta 0.4469 Application: Hydrocarbon liquid for cavitation suppression restriction orifice plate; pump bypass

SN60480002 6 inch, 0.25 thick, Beta 0.63390 Application: High pressure steam

SN60480003 3 inch, 0.25 thick, Beta 0.70386 Application: High pressure steam

SN60480005 8 inch, 0.25 thick, Beta 0.74813 Application: High pressure steam

SN60530001 8 inch, 0.5 thick, Beta 0.77318, Ring Joint Flange Application: Well head gas and condensate flow (high pressure 2-phase flow)

SN60890002 4 inch, 0.25 thick, Beta 0.72000 Application: Air compressor stream

SN60890006 8 inch, 0.25 thick, Beta 0.52000 Application: Air compressor stream

SN61360001 8 inch, 0.25 thick, Beta 0. 83008 Application: Steam

SN61710004 8 inch, 0.25 thick, Beta 0.5 Application: Space Shuttle Program

SN61710005 8 inch, 0.25 thick, Beta 0.65 Application: Space Shuttle Program

SN61710006 8 inch, 0.25 thick, Beta 0.8 Application: Space Shuttle Program

SN61710007 4 inch, 0.25 thick, Beta 0.5 Application: Space Shuttle Program

SN61710009 4 inch, 0.25 thick, Beta 0.7 Application: Space Shuttle Program

SN61710011 8 inch, 0.25 thick, Beta 0.65 Application: Space Shuttle Program

SN61710012 8 inch, 0.25 thick, Beta 0.7 Application: Space Shuttle Program

SN61880001 4 inch, 4.00 thick, Beta 0.77672 Application: Effluent recycle

SN62130001 4 inch, 0.25 thick, Beta 0.84476 Application: Compressor discharge

SN62260001 8 inch, 0.50 thick, Beta 0.86068, Contoured Application: Boiler gas feed

SN62270001 8 inch, 0.25 thick, Beta 0.64755 Application: Compressor discharge

SN62410001 4 inch, 0.25 thick Application: Restriction orifice

SN62540001 4 inch, 0.25 thick, Beta 0.71446 Application: Air compressor

SN62830001 6 inch, 0.25 thick, Beta 0.50075 Application: Ammonia

SN63130002 4 inch, 0.25 thick, Beta 0.74203 Application: Light oil steam

SN63130003 3 inch, 0.25 thick, Beta 0.77945 Application: Ramp steam

SN63130005 8 inch, 0.25 thick, Beta 0.84811 Application: North loop steam

SN63490005 2 inch, 0.50 thick, Beta 0.71988, Contoured Application: Liquid

SN63550001 2 inch, 0.50 thick, Beta 0.72000, Contoured Application: LOx / Methane

SN70090001 4 inch, 0.50 thick, Beta 0.78688, Contoured Application: Liquid

SN70180001 2 inch, 0.50 thick, Beta 0.5 Application: Air

SN70250004 12 inch, 0.25 thick, Beta 0.63539 Application: Liquid

SN70360001 4 inch, 4.00 thick, Beta 0.77672 Application: Effluent recycle

SN70660001 8 inch, 0.25 thick, Beta 0.83280 Application: Coke vapor stream

SN71840001 16 inch, 0.50 thick, Beta 0.69463, RMS Application: Chlorine

SN72000002 4 inch, 0.25 thick, Beta 0.6 Application: Steam

SN72070002 8 inch, 0.25 thick, Beta 0.6 Application: Air compressor

SN72530001 1.25 inch, 0.50 thick, Beta 0.7002, Contoured Application: Rocket fluids

SN72760001 4 inch, 0.50 thick, Beta 0.70201, Contoured Application: Nuclear Master Meter

SN73110001 4 inch, 0.50 thick, Beta 0.72, Contoured Application: Liquid

SN73200001 10 inch, 0.25 thick, Beta 0.26027, Contoured Application: Acetylene

SN73330001 6 inch, 0.50 thick, Beta 0.72, Contoured Application: Compressor surge control, Critical flow

SN73390001 12 inch, 0.50 thick, Beta 0.69713, Contoured Application: Thermal incinerator feed

SN73410001 6 inch, 0.50 thick, Beta 0.72 +/- 1 mil, Contoured Application: Critical reactor recycle

SN73410002 6 inch, 0.25 thick, Beta 0.7524 Application: Critical reactor recycle

SN73600002 2 inch, 3.00 thick, Beta 0.6, Spool Application: Lethal service

SN80080002 16 inch, 0.25 thick, Beta 0.85188 Application: Para formaldehyde

SN80090001 14 inch, 0.50 thick, Beta 0.36047, Bi-directional, Contoured, Self-centering/aligning - Application: Chlorine

SN80150001 4 inch, 0.25 thick, Beta 0.61341, Contoured Application: Hydrocarbon liquid

SN80150005 8 inch, 0.25 thick, Beta 0.56656 Application: Hydrocarbon liquid

SN80160001 4 inch, 4.00 thick, Beta 0.77672 Application: Air compressor discharge flange

SN80950001 8 inch, 0.50 thick, Beta 0.61635, Contoured Application: Air

SN81020001 2 inch, 3.00 thick, Beta 0.47909 Application: Power Turbine Liquid Fuel

SN81160002 4 inch, 0.50 thick, Beta 0.56806, Contoured Application: Air

SN81280001 6 inch, 0.50 thick, Beta 0.22, Hastelloy C, Restriction, Beveled Application: Liquid RO w/hydraulic hammer limiter

SN81350001 10 inch, 0.50 thick, Beta 0.72, Contoured Application: Liquid Effluent pump