Fume Hood Operating Display Panel

Similar documents
Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Room thermostat with 24-hour time switch and large LCD

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

No. Icon Name Function

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

2017 EcoFactor, Inc.

Digital Thermometer with Ice Alert and Clock

Oxygen (O2) Single-Point Gas Detection System

Electronic timeswitch

Installation Manual. Zoning Kit

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

3226 Trunk Port FXO Doorphone

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Mimic display driver, LED ribbon cable

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

IDP-Zone-6 Six Zone Interface Module

FCCP 200: Fume-cupboard indicator and monitor

2018 thesimple, Inc.

Smart Thermostat RDS110

Square D Clipsal Outdoor Light-Level Sensor

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Analog Room Pressure Monitor RPC Series

Multi-Gas-Controller MGC2

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Wireless High Bay Sensor (WHS100) Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Independent Zone Control (I.Z.C.)

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Two-Channel Gas Controller

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

Wireless External Alarm

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

EW 40 Wireless Fan Control

Ion Gateway Cellular Gateway and Wireless Sensors

Projection Alarm Clock

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Call stations and extensions

A WLAN compatible router Valid address Smartphone. 1. Select a language. Tap the language to select. Tap to view more languages. Tap.

Installation and ZONES: Operation Manual. Model: ON STI-34108

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

TEC2100 Series Networked Thermostats

Wall-mounted room thermostat with LCD

Operation and Maintenance Manual

Disclaimer. Trademarks. Copyright. Warranty

Wireless Weather Station. Table of Contents

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

PRELIMINARY EDITION

USER MANUAL FOR OPERATING SYSTEM

MMF Six Zone Interface Module

WatchDog Wireless Crop Monitor Operation Manual

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

180 Degree Ceiling Mounted Occupancy Sensors

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

AIRFLOW SPECIFICATIONS

Little Anne. Important Product Information

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

Semi flush-mount room thermostats

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

C-Bus Four Channel Analogue Output Unit Installation Instructions

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

CLEANROOM MONITOR CR3A Network - Installation Instructions

Flush-mounted room thermostat

Carbon Monoxide Transmitter

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

RVL479. Heating Controller. for use with a partner unit

Soil-Clik OWNER S MANUAL. Soil Moisture Sensor Wired Soil-Clik Module and Probe. Sensor for Compatible Hunter Controllers

Wireless Thermostat (WTS10) Keypad Operation Guide

ALARM FOR SAFETY CABINETS SPECIFICATIONS

Wireless Home Appliance Timer Remote Control Kit

AirGard. Air Flow Monitors

Combustible Gas Detection and Control System

USER MANUAL OUTDOOR IR ILLUMINATOR

Wireless Color Weather Station

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

Flush-mounted room thermostats

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

CONNEX Smart Thermostat CST R00

Explorer F210 Fuel Instrument Installation and Operation Manual

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Wireless room thermostat with LCD

9000P Wireless Alarm Owner s Manual

Room thermostats with LCD RDD100..

Touchscreen Comfort Control

TEC1100 Series Thermostats

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Transcription:

Desigo TRA Fume Hood Operating Display Panel QMX3.P87 The Operating Display Panel (ODP) is the interface between the operator and the DXR Fume Hood Controller (FHC). LCD display for volume flow setpoint, face velocity setpoint and alarms Alarm and warning notifications Silence alarm button Multiple operator selectable setpoints Control of fume hood light Energy Efficiency function Green Leaf Interface KNX PL-Link (for TRA, with plug & play functionality) Powered by KNX PL-Link Auxiliary keys (8 programmable) Building Technologies

Features Digital display of face velocity in meters per second (mps) or feet per minute (Fpm) Digital display of exhaust airflow in cubic meters per hour (m 3 /h), cubic feet per minute (cfm) and liters per second (l/s) Green, yellow and red LED status lights Alarm horn with dedicated silence alarm button Emergency max push button Use The KNX Operating Display Panel (QMX3.P87) is the interface between the fume hood operator and the control system. It includes a custom designed package for visual and audible indication of fume hood operating conditions and push-buttons for emergency mode operation, alarm silence and user defined auxiliary buttons. The panel is mounted on the wall or fume hood in an easily accessible location. Up to two Operating Display Panels are supported per Fume Hood Controller. Functions Visual Indicators Meaning Action Fume hood is operating efficiently None Action required Press Key 5 to return to energy efficient operation, check display for instrucitons Green LED - Solid Green LED Flashing Yellow LED - Solid Normal operation, no alarms or warnings present Pending change to Low air volume flow mode Fume hood is operating in Low airflow mode, no alarms or warning present High airflow warning Low airflow warning Sash open above maximum operating position Stabilizing jet fan failure None Follow lab safety procedures Follow lab safety procedures for high airflow warning indication Follow lab safety procedures for low airflow warning indication Close sash to a safe operating position Follow lab safety procedures for stabilizing jet fan failure Yellow LED - Flashing Fume hood use for lab room exceeded Close fume hood sash to reduce fume hood exhaust 2

Red LED Visual Indicators Meaning Action High airflow alarm Low airflow alarm Emergency purge Airflow measuring or sash measuring device failure Fume hood has been decommissioned Fire High exhaust air temperature Follow lab safety procedures Constant buzz Long buzz Short buzz Audible Information Meaning Action High airflow alarm Low airflow alarm Emergency purge Airflow measuring or sash measuring device failure Fire Sash open above maximum operating position Pending change to Low air volume flow mode Follow lab safety procedures Close sash to safe operating position Follow lab safety procedures Five buzz/minute Sash opening alert Close fume hood sash to reduce fume hood exhaust Buttons/Controls Meaning Action Horn Silence Mutes audible alarm None EMERGENCY MAX Rapid exhaust of fume hood contents in a spill situation If there is a spill, push button, lower sash, and follow lab safety procedures Technical design Mechanical design The unit always communicates as a KNX PL-Link device. Up to two operator display units can be connected to the same controller. The operating and display unit can perform the following functions without a controller: Monitoring of the communication to the controller. The green and yellow LEDs go off in the event of communication failure. The red alarm LED is activated. Components Segmented backlit display. "Green Leaf" energy efficiency function. Three status LEDs. Eight auxiliary buttons to support sash closure, light switches, and setpoint adjustment. Alarm buzzer. Horn silence button. Emergency max button. Communication port. The details of the functions of the elements are specified by the application of the connected controller. 3

Type summary Type Stock number Designation QMX3.P87-1WSC S55624-H111 Fume hood operating display panel Delivery The following items are packaged with product: Installation instructions KNX terminal block Screws (6) Product documentation Topic Title Document ID: Installation/Mounting Engineering and commissioning, workflow Wall mounted sensor and room operator units for KNX PL-Link ABT online help CM2M1602xx Commissioning User's guide: Setup & Service Assistant (SSA) CA111050 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download n.a. Notes Security CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage Observe national provisions and comply with the appropriate safety regulations. Engineering Fume hood automation The unit complies with the requirements for a fume hood operating device (see Conformity). Volume flow control, monitoring and light control can be implemented and automated for a fume hood together with a fume hood controller. Flexible use The functionality of the buttons, LEDs and alarm buzzer is defined by the application in the controller that controls the operator display unit. This ensures that the unit can be flexibly used. 4

Mounting The mounting plate is designed for the fume hoods with or without existing cutouts. designed for fume hood or wall-mounting. A conduit box is optional (A). base plate (B) has screw holes for all commercially available conduit boxes. The height of the screw heads must not exceed 3 mm. ODP device (C). Installation For KNX PL-Link wiring (topology, allowed cables and cable length), see the Desigo TRA installation guide, CM111043. Use the correct cables for the KNX PL-Link bus Do not interchange the wires of the KNX PL-Link cable. The red terminal is for KNX PL-Link + The gray terminal is for KNX PL-Link Observe all local installation regulations. CAUTION The devices are not protected against accidental connection to AC 230 V. 5

Operation The fume hood operating panel displays the current condition of the fume hood by illuminating one of its three status LEDs. The average face velocity of the fume hood can be displayed in ft/min or m/s. During an abnormal operating condition, the QMX3.P87 displays various messages to alert you of the condition. Horn silence button Pressing the Horn Silence button will turn the internal audible alarm off for the current alarm event. Emergency max button Emergency max automatically overrides any other control mode in the Fume hood controller. Pressing the Emergency max button will remove contaminated air from the fume hood by switching to an emergency exhaust flow level. The internal audible alarm will sound. Pressing the Emergency max button a second time reverts the FHC to normal operation for the current conditions. Display layout of fume hood operating display panel A - text messages B - setpoint, actual value, dynamic icon or text C - light display D - audible state display E sash close display 6

Function of the display elements and keys An arrow indicates that an element can be operated Fume hood setpoint selection (Key 3 or Key 7): Off, Auto, Setpoint 1, Setpoint 2, Setpoint 3 Dynamic close the sash Horn silence Fume hood light (Key 4) Automatic sash closing (Key 8) Advanced settings Press keys 1 and 8 simultaneously for 5 seconds Exit (Key 5) Menu select (Key 2 or Key 6) Setting select (Key 3 or Key 7) Auxiliary Keys Eight auxiliary keys are available for user defined programming. Key 1 Programmable for LSSB (Light switching sensor basic) operation* Key 2 Programmable for LSSB operation* Key 3 Manual setpoint adjustment or programmable for LSSB operation* Key 4 Fume hood light** Key 5 Green leaf reset Key 6 Programmable for LSSB operation* Key 7 Manual setpoint adjustment or programmable for LSSB operation* Key 8 Automatic sash closing** *ABT Pro is required to program buttons for LSSB. **Optional. Additional hardware and configuration required. Connecting KNX R1 QMX3.P87 Fume hood operating display N1 Controller, actuator Twisted pair + Red KNX PL-Link (positive) - Gray KNX PL-Link (negative) Note The device is protected against faulty wiring but communications will not work on interchanged wires. 7

Tool plug 2.5 mm Jack Tool cable RJ45 plug 1 CE+, KNx 5 Voltage 16 V 2 CE-, KNX 6 N.C. 3 N.C. 7 Identification pin 4 N.C. 8 GND Connecting tool Connect the ABT to load the application in the room automation station, or for service purposes: Directly to the room automation station. To the room unit using the tool cable and the OCI702 service interface (see data sheet A6V10438951). Commissioning KNX When only one device is connected to the KNX PL-Link bus, the operating display panel automatically establishes communications with the Fume hood controller, from where the functions are downloaded to the operating display panel (plug & play). Addressing: 1. Short press the programming pin (<0.5 sec). The device goes into programming mode; the service LED is continuously on. The tool identifies the current operating display panel that is operated and assigns it. 2. After the device is commissioned, deactivate the programming mode by shortly pressing the programming pin (<0.5 s). The service LED goes off. Note: Programming mode resets to disabled each time the device restarts. 8

Factory reset: 1. Long press the programming pin (>20 s). The device is locked and reboots within 10 seconds. The Fume hood controler deletes it from its device list. During this time, it is safe to remove the device from the network. If the bus plug remains connected, the device acts like a newly inserted device requiring again automated or manual configuration. Note: This operation resets all user preference data and configuration settings to factory default. This operation is irreversible. Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Warranty Technical data on specific applications are valid only together with products listed under "Equipment combinations". rejects any and all warranties in the event that third-party products are used. 9

Technical data Dimensions and Weight Dimensions Weight 140 mm x 80 mm x 39 mm (5.5in H x 3.125in W x 1.5in D) 226 g (8 oz.) Specifications Face Velocity Display Range Face Velocity Display Resolution Exhaust Air Volume Flow Display Range Exhaust Air Volume Flow Display Resolution Push-Buttons/Switch inputs Alarm Horn 0 3937 Fpm (0.01 20 m/s) 1 fpm, adjustable (0.01 m/s) 0 126400 cfm (0 214748 m 3 /h) 1 cfm, adjustable (1 m3/h) 1 Emergency ax 1 Horn silence 8 Auxiliary Keys 85 db @ 10 cm (4 in) Power supply Supply voltage Power consumption from room automation station Operating voltage range KNX / PL-Link DC 21...30 VDC Max 8 ma at DC 24 V Interfaces KNX PL-Link Type: KNX TP1, galvanic isolation. Baud rate: 9.6 kbps. Short-circuit proof. Protection against faulty wiring at max. AC 24 V. Wiring connections Cable type Wiring lengths for signals. TP-1 Twisted Pair Min. 0.8 mm (AWG20) Max. 1.0 mm (AWG18) KNX PL-Link 80 m (262.5 ft) with internal bus power or 300 m (984.3 ft) with external power supply. Ambient conditions and protection classification Classification as per EN 60730 Function of automatic control devices Degree of contamination Overvoltage category Design type Degree of protection of housing to EN 60529 Climatic ambient conditions Transport (packaged for transport) as per EN 60721-3-2 Operation as per EN 60721-3-3 Mechanical ambient conditions Transport as per EN 60721-3-2 Operation as per EN 60721-3-3 Type 1 2 III. Device suited for use with equipment of safety classes I and II. IP20. Class 2K3 Temperature -25...70 C (-13... 158 F) Air humidity 5...95%. Class 3K5 Temperature -5...50 C (23... 122 F) Air humidity 5...95%. Class 2M2. Class 3M2. 10

Standards, directives and approvals Product standard - Automatic electrical controls for household and similar use Product Standard - General requirements for Home and Building Electronic Systems (HBES) Electromagnetic compatibility generic immunity standard, Industrial environment Electromagnetic compatibility generic emission standard, Domestic, commercial, light industry. EU conformity (CE) EAC compliance IEC/UL/EN 60730-1, part H.23 Emission and H.26 Immunity EN 50491-5-1, EN 50491-5-2, EN 50491-5-3 Immunity IEC/EN 61000-6-2 Emission IEC/EN 61000-6-3 DoC Document number: A5W90001444 Eurasien compliance for all QMX3.P variants RCM conformity AS/NZS 61000-6-3 : 2012 DoC Document number: A5W90001445 UL Approbation Federal Communications Commission* CSA and cul ICES-003 Environmental compatibility UL 916 PAZX Energy Management Equipment, http://database.ul.com FCC CFR 47 Part 15 Subpart B Class B C22.2 No. 205 Signal Equipment CAN ICES-3 (B) / NMB-3 (B) The product environmental declaration contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). * This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 11

Dimensions Issued by Industry, Inc. Building Technologies Division 1000 Deerfield Pkwy Buffalo Grove IL 60089 Tel. +1 847-215-1000 Industry, Inc., 2017 Technical specifications and availability subject to change without notice. 12 Document ID Datasheet Edition