LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

Similar documents
Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD-5000 REFRIGERANT LEAK DETECTOR

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

OPERATING INSTRUCTIONS

CLI Refrigerant Gas Leak Detector. User s Guide

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

99 Washington Street Melrose, MA Phone Toll Free Visit us at

D-TEK Select. Refrigerant Leak Detector

REFRIGERANT LEAK DETECTOR

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Leak-Seeker I Refrigerant Leak Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

Refrigerant / Combustibles Leak Detector

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

H-10PM. Refrigerant Leak Detector

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

NGD8800 USER S MANUAL

GERMANY TEC 'LOGY leak-detect EXPERT

SENSIT HXG-2d Combustible Gas Detector

GAS-Mate. Combustible Gas Leak Detector

Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector

Famous Trails Anaheim, California

RLD-H10G Refrigerant Leak Detectors

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Leak Monitors and Leak Detectors

For technical support call:

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Danfoss gas detection units

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

User Manual SF6 GASCHECK 6000

Operator's Manual. LIGHTNING 2 Laser Detector

AC1234 PRODUCT RANGE.

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

The Professional Metal Detector OWNER S MANUAL

Refrigerant / Combustibles Leak Detector

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

External Wireless Sounder

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

AIR CONDITIONNING 95 CODE 002

LEADERS IN LIQUID SCIENCE.

User's Guide. Pinless Moisture Meter. Model MO257

testo 316-EX gas leak detector Instruction manual

Water Tank Level Monitor

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Portable Air Conditioner

MODEL 951 RADIATION DETECTOR

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

OWNER S MANUAL. Fortune Finder Platinum Edition TC-3020 GET THE LATEST UPDATED MANUAL FOR THIS PRODUCT BY VISITING US FREQUENTLY AT

EVac II Programmable Digital Vacuum Gauge

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

FEATURES ON/OFF Button Pinpointing Tip 360 Side-Scan Area Exclusive Scraping Blade LED Flashlight Speaker Lanyard Attachment Loop Sealed Battery

Agrifim A675CT Timer. Frequently Asked Questions

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

RAM GENE / RAM GENE-1

WARNING Important Safety Information

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Mold Alert... Operation Manual P0270

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

DM200 = CS200 METAL DETECTOR

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

USER MANUAL MINITRACER PORTABLE SNIFFER

This instruction manual explains the use of three models listed on the left.

Smoke Alarm User s Manual

aspida User Manual T: +44 (0) F: +44 (0) W: E:

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

RAGNAR STÅLSKOG AB INSTRUCTION MANUAL HVDC-H HVDC-L VOLTAGE DETECTOR HVDC-H, HVDC-L 15H11

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

INSTRUCTION MANUAL CD Fax: (503)

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

evac Pro Programmable Digital Vacuum Gauge Operation and Maintenance Manual

LD200 / RLD400 LD200-G /RLD400-G

AIRAH Victoria Refrigerants Update

Transcription:

LD900 Refrigerant Gas Leak Detector Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends User Manual Design certified by ASCI and Intertek to meet SAE J2791 & ASCI J2913, EN14624-2012 & ASHRAE 173-2012 Made in U.S.A. LeakDetectors-LD900-UserManual.indd 1

INTRODUCTION The LD900 features a long life solid electrolyte sensor technology that is designed to detect more current and difficult HFC refrigerants such as R-134a, R-410A, R-404A, R-407A, and R-507 in addition to the new HFO-1234yf and all HCFC (R- 22) and CFC (R-12) refrigerants including SNAP approved hydrocarbon blends. Our unique digital leak size indicator takes the guesswork out of whether to repair a small leak. The digital display is independent from the audio alarm and sensitivity level, allowing the precise pinpointing of the leak source. The LD900 does not require rechargeable batteries. FEATURES Unique numeric leak size indicator Long life, stable sensor R-134a sensitivity.05 oz/yr R-1234yf sensitivity.015 oz/yr R-22 sensitivity.025 oz/yr Design certified to meet SAE J2791, SAE J2913, European EN14624 Automatic calibration and reset to ambient Visual LED leak alarm near sensor 3 adjustable sensitivity levels Low battery indicator True mechanical pump Audio mute function Uses 4 AA alkaline batteries CE Certified Comfortable Sanoprene grip 2-year warranty includes sensor Made in USA 2 LeakDetectors-LD900-UserManual.indd 2

LD900 CONTROL PANEL Digital Leak Size Indicator Low Battery Indicator Sensitivity Level Indicators Audio Mute & Sensitivity Level Selectors Power On/Off OPERATING INSTRUCTIONS 1. TURN ON: Press the ON/OFF button once to turn on and again to turn off. NOTE: Hold button down for approximately 1 second to turn unit off. 2. WARM UP: The detector automatically starts heating the sensor. During the heating cycle, the digital leak size indicator will flash 0 and the detector will sound a slow beep. Warm up time is usually less than 20 seconds. 3. READ: The detector is ready to begin searching for leaks when the flashing 0 stops and the green sensitivity LED turns on. The audio beep increases in frequency and the probe LED begins to blink steadily. 4. SEARCHING: When searching for leaks, move the sensor tip along A/C lines and fittings no further away than 0.4 in. (9.5 mm) and no faster than 3 in./sec. (75 mm/sec.) If the detector alarms, make smaller sweeps back and forth until the leak source can be pin pointed. NOTE: The LD900 only responds to changes in leak concentration. The alarm will re-set automatically if the sensor tip is held at the leak source. If the leak detector has been out of use for an extended period, weeks or months, the following action is recommended. Power on the instrument and allow it to come out of warm up. Then run it with the sensitivity level in the Hi (high) position for several minutes before testing it with the Leak Test Vial. This action will guarantee that the sensor is fully conditioned for maximum response to refrigerant gas. 3 LeakDetectors-LD900-UserManual.indd 3

LEAK SIZE INDICATOR The digital leak size indicator remains off normally but once a leak is detected, a number from 1-9 will be displayed for all HFC and HCFC refrigerants regardless of the sensitivity setting. The number will continue to increase or decrease depending on the amount of refrigerant sensed. The maximum value will be displayed once the leak source has been located. The table below can be used to approximate the size of leak: Maximum # Approx. Leak Size Approx. Leak Size Displayed (oz/yr) (g/yr) 1-3 < 0.1 <3 4-6 0.1 to 0.5 3 to 14 7-9 >0.5 >14 LOW BATTER INDICATOR Replace the 4 AA Alkaline batteries when the red LED on the control panel is lit. Follow battery installation instructions under Maintenance section. AUDIO MUTE FUNCTION To silence or mute the audio beep and alarm signal, press the MUTE button. To restore the audio sound, press the MUTE button again. (Note: a few seconds is required to restore sound if the mute button is pressed in rapid succession.) 4 LeakDetectors-LD900-UserManual.indd 4

ADJUSTING SENSITIVIT LEVELS The leak detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on. To change sensitivity levels, press the SENS once for HI sensitivity (red LED will turn on) and again for LO sensitivity (yellow LED will turn on). LEAK TEST VIAL The leak detector comes with a Leak Test Vial that allows the user to make sure the detector is performing properly. To test: 1. Remove the colored label dot in the center of the screw cap to expose the vent hole in the top of the screw cap. (see fig. below). 2. Turn on the leak detector and allow the instrument to complete the warm up cycle. 3. Place the sensor close to the small hole in the top of the Leak Test Vial. The beep rate should increase and the Digital Leak Size Indicator should display a number from 3-6 indicating that the sensor and the electronics are working properly. Remove label dot over vent hole before testing Vial cap with vent hole Expiration date on label NOTE: Replace the Test Vial back in the nylon bag when not in use to extend the shelf life. Replace Test Vial when the green color is less than ¼ full or at the time of the expiration date. 5 LeakDetectors-LD900-UserManual.indd 5

BATTER MAINTENANCE Install Batteries: Remove screw located at rear end of unit and pull down hinged battery door to open as shown. Always insert all four batteries into the battery compartment in the same direction. Note: polarity mark on the inside of the battery door for proper battery orientation. Polarity mark SENSOR MAINTENANCE Replace Filter: Unscrew sensor tip as shown to replace filter. Replace filter whenever it becomes visibly dirty or every 2 to 3 months depending on use. Replace Sensor: Remove sensor by pulling out of socket. Install the new sensor by aligning the Keyway notch in sensor cover with the raised keyway on sensor socket holder (see figure below). Note: Do not force sensor into socket. Misalignment can damage the sensor pins. Unscrew tip to replace filter Filter Push straight on (do not twist) to install sensor Keyway alignment Pull straight out (do not twist) to remove sensor IMPORTANT: The instrument s software is designed to alert the user if the sensor is dislodged or defective. If the sensor is not fully inserted into the six-pin socket, or if it is defective, the instrument will not come out of the Warm Up mode for proper operation when the power button is turned on. Additionally, if the instrument becomes unstable during its operation, it is an indication that the sensor may be defective or dislodged. 6 LeakDetectors-LD900-UserManual.indd 6

PRODUCT SPECIFICATIONS Model # LD900 Name Leak Detector, Refrigerant Gas Sensitivity.05 oz/yr R134a,.015 oz/yr R1234yf,.025 oz/yr R22 Sensor Life > 10 years Response Time Instantaneous Power Supply 4 AA Alkaline batteries Battery Life 4-6 hours continuous Warm up time < 20 seconds Probe length 17 inches (43.8cm) Numerical Display 7 segment digital display (1 to 9) Weight, lbs. 1.5 lbs. (0.68kg) Warranty 2 years (includes sensor) EN14624-2012 TEST SPECIFICATIONS Minimum/Maximum Sensitivity Threshold (fixed) Minimum/Maximum Sensitivity Threshold (moving) Minimum Detection Time (1gm/yr) Clearing Time Minimum Threshold after Maximum Exposure Sensitivity Threshold in Polluted Atmosphere Calibration Frequency 1 gm/yr minimum, >50 gm/yr maximum 3 gm/yr minimum, > 50 gm/yr maximum Approx. 1 sec Approx. 9 seconds after exposure to >50 gm/yr 1 gm/yr 1 gm/yr 1/yr check with calibrated leak Standard CROSS SENSITIVIT TO AUTOMOTIVE CHEMICALS Some automotive solvents and chemicals have similar hydrocarbon properties as R134a and may elicit a positive response. Before leak checking, clean up any chemicals in the list below that elicit a positive response Chemical Name/Brand Rain-X Windshield Wash Fluid Ford Spot Remover (Wet) Ford Rust Inhibitor Ford Gasket Adhesive (Wet) Loctite Natural Blue degreaser (diluted) Ford Brake Parts Cleaner Ford Silicone Rubber (uncured) Motorcraft Antifreeze heated to 160 F Gunk liquid wrench Ford silicone lubricant Ford Pumice lotion (with solvent) Ford Motorcraft brake fluid Ford Carburetor Cleaner Dextron Transmission fluid heated to 160 F Quaker State Motor Oil heated to 160 F Response (partial) N N N 7 LeakDetectors-LD900-UserManual.indd 7

REPLACEMENT PARTS Item Sensor with Sensor Tip & Filter Sensor Filters (5 pack) Leak Test Vial Sensor Tip with Filter Parts Kit (includes sensor, test vial, & filter kit) Carrying Case Part Number S77694 S77695 S77696 S77698 S77697 S77699 WARRANT The LD900 Refrigerant Gas Leak Detector is warranted to be free of defects in materials and workmanship for a period of two years from the date of purchase. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorized opening of the unit. Tools should be returned to the buyer s place of purchase. SERVICE/TECHNICAL QUESTIONS CALL TOLL FREE: 888.467.8665 www.imperial-tools.com info@stridetool.com 30333 Emerald Valley Pkwy. Glenwillow, Ohio 44139 888.467.8665 LeakDetectors-LD900-UserManual.indd 1