EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Similar documents
Precision air handling cabinets Ciatronic MICRO/EXPAIR

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Vertical self-contained air conditioner

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

CLIMACIAT AIR COMPACT

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Centrifugal air heaters hot water or electrical supply

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Compact and silent Scroll compressors All-season operation

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

NA B MAGISTER. Instruction manual

NA G µair CONNECT 2

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

NEXT DL NEXT DL. rcgroupairconditioning

K Series Modular air conditioners. With direct expansion coil With chilled water coil

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

DYNACIAT POWER. High energy efficiency Compact and quiet

DYNACIAT ILG. Use. Description. Heat pumps

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Aquaciat Free cooling

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

YORK Close Control units

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

CORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Roof top SPACE RPC 315Z R407C MA00

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

NA B AIR COMPACT. Instruction manual

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

TECNAIR LV C series Close control air conditioners

TECNAIR LV C series Close control air conditioners

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

2013 Product Range Precision Air Conditioners (CRAC)

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

DATATECH. Precision air conditioners for technological environments 6 220

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

next p dw next p dw rcgroupairconditioning

VariCool VAV Engineering Guide

CHAPTER 6 CONDENSING UNITS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Roof top SPACE RPC 450Z R407C M011

next evo cw next evo cw rcgroupairconditioning

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Flexible & Innovative. Cooling Solutions

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Water chillers water/water type SIGMA Technical information manual

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

HT V2 HT Split

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Integrated VarIable refrigerant flow ahu/pau (r410a)

Transcription:

Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision air handling cabinet particularly suited to air treatment requirements (filtration, temperature and hygrometry control) in computer and telecommunications facilities and rooms for special use (electronics, metrology, sensitive storage, medical, controlled atmosphere rooms). Dual-wall construction. Fan controlled by a variable frequency drive to ensure flow/pressure balance on site. The unit is quickly and easily installed and particularly easy to use. CW Cabinet supplied with chilled water. DXA Stand-alone cabinet with separate air condensing unit. (R410A). ASSEMBLY UNDER configuration : inverted discharge OVER configuration : discharge from top Assembly 1 Assembly 3 Assembly 4 Assembly 5 Discharge into raised floor Intake from front Intake from rear Return air below 1

Range Unit CW 5 8 12 16 27 39 59 DXA 5 8 10 12 15 19 24 31 36 38 48 Rated air flow rate (1) 1 2000 2500 0 4000 5000 6000 7000 8000 10000 12000 Associated CL condensing unit (2) 28 28 35 35 50 65 75 2x50 2x65 2x65 2x75 (1) Air flow rate adjustable by built-in variable frequency drive. (2) Two condensing units per air handling cabinet for 31 and 48 models. Quick selection CW Unit CW 5 CW 8 CW 12 CW 16 CW 27 CW 39 CW 59 Air flow (m 3 /h) 1 2000 2500 0 4000 5000 6000 7000 8000 10000 12000 Cooling capacity (kw) 5 8 10.5 14.7 18.5 23.5 27 34 38 48 55 Water flow (m 3 /h) 0.86 1.4 1.8 2.5 3.2 4 4.6 5.8 6.5 8.2 9.4 Pressure drop (mce) 4.3 4.9 5.1 4.7 7 4.1 5.2 7.3 8.9 5.5 6.9 Characteristics: total cooling capacity, pure water at 7 C/12 C, air at 24 C, 45 % RH. Pressure drop with control valve. Cooling capacity for maximum DT on air of 12 C. Correction factors 7 / 12 C 8 / 13 C 22 C / 45% 0.84 0.79 24 C / 45% 1 0.9 DXA Unit DXA 5 DXA 8 DXA 10 DXA 12 DXA 15 DXA 19 DXA 24 DXA 31 DXA 36 DXA 38 DXA 48 External units, quantity and type 1xCL 28 1xCL 28 1xCL 35 1xCL 35 1xCL 50 1xCL 65 1xCL 75 2xCL 50 2xCL 65 2xCL 65 2xCL 75 Air flow (m 3 /h) 1 2000 2500 0 4000 5000 6000 7000 8000 10000 12000 Cooling capacity (kw) 5 8 10.6 11 15 19 23.2 30.1 35 38 47 Characteristics: total cooling capacity, air at 24 C, 45 % RH, 32 C external temperature. Correction factors 30 C 32 C 35 C 40 C 24 C/50% 1.02 1 0.98 0.93 26 C/50% 1.06 1.04 1.02 0.98 Correction factors to be applied to the cooling capacity depending on the external temperatures and the inlet air conditions. 2

Quick selection Hot water coil Unit CW 5 8 12 16 27 39 59 DXA 5 8 10 12/15 19/24 31/36 38/48 Air flow (m 3 /h) 1 2000 2500 0 4000 5000 6000 7000 8000 10000 12000 Heating capacity (kw) 4.5 6.2 7.5 11.9 13.7 17.8 19.5 25.8 27.6 37.5 40.9 Water flow (m 3 /h) 0.21 0.27 0.33 0.5 0.6 0.8 0.9 1.1 1.2 1.65 1.8 Pressure drop (mce) 1.3 2.6 4.3 2.1 2.8 1 1.2 1.7 1.9 2.8 3.3 Characteristics: heating capacity, air at 20 C, pure water at 80 C/60 C, pressure drop with control valve. Correction factors to be applied to the heating capacity for water temperatures of 90 C/70 C: 1.23 and 45 C/35 C: 0.37. Electric heater Unit CW 5 8 12 16 27 39 59 DXA 5 8 10 12/15 19/24 31/36 38/48 Heating capacity (kw) 3 3 6 9 12 18 24 Ventilation Unit CW 5 8 12 16 27 39 59 DXA 5 8 10 12/15 19/24 31/36 38/48 Air flow (m3/h) 1 2000 2500 4000 6000 8000 12000 Maximum available pressure with G4 or F7 filtration 240 98 113 125 160 65 57 Maximum available pressure depending on air flow rate. Subtract approx. 20 Pa if hot water coil present on. The operating point may be adjusted directly using the built-in voltage generator. All combinations of air flow rate and available pressure are therefore possible up to the maximum values shown in the table above. Description Casing n Double-wall construction. n Pre-lacquered removable grey RAL 7035 panel: - external pre-lacquered sheet, thickness 1.0 mm - class M0 glass wool, thickness 25 mm - internal galvanised sheet, thickness 0.8 mm Filtration n F2SI filter cells, 90% efficiency according to ASHRAE gravimetric test (G4). n Optional F7 opacimetric filter. n Optional dual filtration (G4 + F7)* n Filter cells held in compression on a counter-frame with a seal to prevent all leaks. n Blockage level monitored by an analogue pressure sensor. Cold coil section n Coil copper pipes and aluminium fins. n Condensates drain pan. n CW model with 2- or 4-way control valve fitted and connected. Heat-insulated connection hoses available as an option. n Model DXA with thermostatic expansion valve. Ventilation section n Direct drive centrifugal fan. n Electric motor (3-Ph / 400 V / 4 poles / class F). n Variable frequency drive fitted for air flow control. n Air flow detected by an analogue pressure sensor. Internal unit electrical cabinet Power, control and regulation cabinet including: n Supply: 400 V / 3-Ph / 50 Hz + N + E n Main cut-off (emergency stop type) on front panel. n 400 V / 3-Ph / 24 V transformer with protection. n Protection and control for fan motor, and depending on options for humidifier and electric heater. n CIAT µair CONNECT2. n Dry temperature of return air tested. n Return humidity control: - Humidity control during auxiliary operation (optional) - Humidity control during dehumidification (optional) n Optional features include water leak detection, fire thermostat and supply air low limit. n Remote control and fault summary contact. n Optional condensate pump. * not available on DXA 5/8/10 and CW 5/8/12 models 3

Accessories n Support base for discharge into raised floor low version (225-320 mm) high version (320 to 525 mm) n Supply plenum n Acoustic plenum with noise trap n Motorised intake damper n Water leak detection n Fire thermostat n Hydraulic connection kit (chilled water and hot water coils) n LON gateway n C/O sensor (only on CW) Description of external unit (DXA model) n CL type air condensing unit n Supply: 400 V / 3-Ph / 50 Hz + N + E n SCROLL hermetic compressor n HP and LP safety pressostats n Isolating and adjustment valves n 1 cooling circuit n Refrigerant: R410A n Condensation pressure adjusted by electronic circuit board and pressure sensor. Speed variation on condenser fan n Faults signalled to internal unit Options Electric heater n Operation linked to fan n Two-stage control (3 kw electric heater excepted) n Two-stage or TRIAC control on n Two high limit safety thermostats, automatic and manual reset Hot water coil n Coil with one row of copper tubes and aluminium fins. n 2- or 4-way control valve fitted and connected. n Optional connection hoses. Control Control and supervision of units Humidifier n Immersed electrode humidifier with CPY board for feeding back information relating to the humidifier directly to the CIAT µair CONNECT2 PLC: Stainless steel electrodes with large surface area 3 kg steam per hour rated flow rate < 0 m3h 8 kg steam per hour rated flow rate > 0 m3h Steam cylinder contained in one easily-removable item Filling solenoid valves Drain pump Electronic circuit board controlling operation. Diffusion jet Water supply connection kit n Only operates on mains water (conductivity 350 to 1250 µs/ cm, hardness 13 to 30 F), non demineralised or softened water CIAT µair CONNECT2 1 2 3 Reset 4 5 6 7 8 9. 0 - Enter C - 160-character display containing instruction manual, operating reports, faults and corrective actions. Configurable PLC - Two fault levels - Operating time counter - RS 485 output using JBus or ModBus protocol - Can manage rotations, backups and auxiliaries between units. - LON gateway - C/O sensor (only on CW) 4

Electrical characteristics Internal unit (CW and DXA models) Fan motor assembly Control circuit Electric heater (option) Humidifier (option) max. value Total current without option Total current all options Voltage (V) CW 5 DXA 5 CW 8 DXA 8 CW 12 DXA 10 CW 16 DXA 12/15 CW 27 DXA 19/24 CW 39 DXA 31/36 CW 59 DXA 38/48 Power (kw) 0.55 0.75 1.1 1.5 2.25 Current (A) 2.6 3.3 5 6.6 9.9 Voltage (V) 24 Current (A) 1 400V Voltage (V) 400 Power (kw) 3 6 9 12 18 24 Current (A) 4.3 8.7 13 17.3 26 34.6 Voltage (V) 400 Power (kw) 2.25 6 Current (A) 3.2 8.7 Current (A) 3.6 4.3 6 7.6 10.9 Main switch rating (A) Current (A) 11.1 11.1 15.5 26 32.1 42.3 54.2 Main switch rating (A) 16 16 40 63 External unit (DXA model) Unit 5 8 10 12 15 19 24 31 36 38 48 No. and type of external units No./type of electrical power supply 1x28 1x28 1x35 1x35 1x50 1x65 1x75 2x50 2x65 2x65 2x75 1 / 3ph 400V / 50Hz + N +E 2 / 3ph 400V / 50Hz + N +E Max. total current (A) 5 7.5 8.5 8.3 11.3 12.6 15.7 2x11.3 2x12.6 2x12.6 2x15.7 Sound pressure level Internal unit (CW and DXA models) Unit CW 5 8 12 16 27 39 59 DXA 5 8 10 12/15 19/24 31/36 38/48 Air flow (m 3 /h) 1 2000 2500 0 4000 5000 6000 7000 8000 10000 12000 Sound pressure level (dba) 49 53 58 57 61 59 63 60 63 60 64 Sound pressure level of internal unit (CW and DXA) at 2 m, free field, with blower connected, ± 3 db External unit (DXA model) Unit DXA 5 8 10 12 15 19 24 31 36 38 48 Models 28 28 35 35 50 65 75 2x50 2x65 2x65 2X75 Sound pressure level (dba) 39 39 45 45 43 47 47 46 50 50 50 Sound pressure level of external unit at 5 m, 1.5 m four ground level, directivity 2 and ± 3 db 5

Connections/weight Internal unit Unit Chilled water Direct expansion Weight of internal unit (kg) CW 5 CW 8 CW 12 CW 16 CW 27 CW 39 CW 59 DXA 5 DXA 8 DXA 10 DXA12/15 DXA19/24 DXA 31/36 DXA 38/48 115 120 125 280 310 375 480 Chilled water coil (CW) Inlet/outlet connections G ½ M G ¾ M G ¾ M G¾ M G 1 M G 1 M G 1 ¼ M Condensate drain* Ø 32mm Direct expansion coil (DXA) Suction pipes G 5/8 M G 5/8 M G 3/4 M G 7/8 M G 7/8 M G1 1/8 M G1 1/8 M G 2X7/8 M G 2X7/8 M G 2X1 1/8 M G 2X1 1/8 M Liquid pipes 1/2 1/2 1/2 1/2 1/2 1/2 1/2 2x1/2 2x1/2 2x1/2 2x1/2 Condensate drain* Ø32mm Hot water coil Inlet/outlet connections G ½ M G ½ M G ½ M G ½ M G ½ M G ¾ M G ¾ M G ¾ M Chilled water coil connections: inlet on threaded coupling and outlet on threaded control valve. Condensate drain connection on smooth coupling. * Drain connections if optional pump fitted: dia. 6 mm Outdoor unit Direct expansion units Outdoor units (qty/type) Weight of outdoor unit (kg) DXA 5 DXA 8 DXA 10 DXA 12 DXA 15 DXA 19 DXA 24 DXA 31 DXA 36 DXA 38 DXA 48 1x28 1x28 1x35 1x35 1x50 1x65 1x75 2x50 2x65 2x65 2x75 64 69 69 69 101 112 118 101 112 112 118 Refrigerant connections Suction pipes 5/8 5/8 3/4 3/4 3/4 7/8 7/8 2x3/4 2x7/8 2x7/8 2x7/8 Liquid pipes 3/8 3/8 3/8 3/8 3/8 3/8 1/2 2x3/8 2x3/8 2x3/8 2x1/2 Condensate drain Ø32mm 6

Dimensions B B' A' A C Internal unit Units Dimensions (mm) A A B B C Weight (kg) CW5 DXA5 675 125 500 183 1700 115 CW8 DXA8 675 125 500 183 1700 120 CW12 DXA10 675 125 500 183 1700 125 CW16 DXA12/15 850 125 183 280 CW27 DXA 19/24 1150 125 183 310 CW39 DXA 31/36 1490 120 183 375 CW59 DXA 38/48 1990 120 183 480 C B' B B'' A' A A" Units Outdoor unit Dimensions (mm) A A A B B B C 28 1035 449 1500 658 69 35 1035 449 1500 658 69 50 1035 449 1500 1258 101 65 1035 449 1500 1258 112 75 1035 449 1500 1258 118 Weight (kg) 7

1700 82 675 850 450 1150 125 800 125 125 800 125 1490 1990 120 1250 120 120 1750 120 183 183 297 297 183 183 500 78 297 297 297 8

CW 5/8/12 DXA 5/8/10 CW 16 DXA 12/15 CW 27 DXA 19/24 1700 675 180 233.5 850 183 334 333 1150 164 268 210 268 239 500 260 58 CW 39 DXA 31/36 CW 59 DXA 38/48 1490 1990 183 334 246 334 393 183 334 246 334 248 334 313 9

Dimensions Internal unit (CW and DXA models) n Configuration OVER 4 CW 5/8/12 DXA 5/8/10 CW 16 DXA 12/15 CW 27 DXA 19/24 1700 500 200 CW 39 DXA 31/36 CW 59 DXA 38/48 260 83 58 200 57.5 560 57.5 83 125 600 125 125 900 125 83 675 850 1150 160 233.5 183 334 333 154 268 210 268 239 83 120 1250 120 83 120 1750 1490 1990 183 334 246 334 393 183 334 246 334 246 334 313 120 10

CW 5/8/12 DXA 5/8/10 CW 27 DXA 19/24 1700 675 1150 159 234 1625 268 208 268 243.5 51.5 165 51.5 250 15 15 Ø 3.5 CW 39 DXA 31/36 1490 CW 59 DXA 38/48 181 334 244 334 397 181 334 244 334 244 334 319 51.5 231 51.5 51.5 231 51.5 291 227 291 227 250 32 250 32 Ø Ø 239 32 239 32 182 239 32 262 291 227 32 3.5 3.5 11

Dimensions External unit n 28 and 35 models I H G C D F B 1 2 E A n 50, 65 and 75 models I H G C 1 2 D F B E A CL A B C D E F G H I 28 and 35 1.035 449 658 30 602 375 1.030 5 350 50, 65 and 75 1.035 449 1.258 30 602 375 1.030 5 350 1 2 EXTERNAL AIR FLOW LIQUID LINE SUCTION GAS LINE 12

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel. : 08 11 65 98 98 (0,15 / mn) Fax : 08 26 10 13 63 (0,15 / mn) Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114 Certified Management System 13