D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

D-TEK -MS Vehicle Loop Detector. Operating Instructions

ENGINEERED PARKING SYSTEMS MODEL 3416D

Operating Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

WIRING DIAGRAM AND INSTRUCTIONS

MD12-1 Vehicle Loop Detector

MD12-2 Vehicle Loop Detector

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

DSP-13 Tri-Axis Detection (TRIAD TM ) System

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Model 17A00 Expansion Enclosure

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

I/O ZONE 560/583 AND OPERATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation, Operating and Maintenance Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Overload LED On & Power LED On

INSTALLATION AND INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL B2 INSTALLATION MANUAL

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit

3510 East Atlanta Avenue, Phoenix, AZ USA

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

KP: Charge Air Cooler (CAC) Pump

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

24 VAC Intermittent Pilot Gas Ignition Control

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

ESSEX ENGINEERING CORPORATION

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

LeakSafe. solutions. WaterSwitch2. Installation Instructions

4 & 8-POINT ANNUNCIATORS Instruction Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SP-1000X. Panic Device Power Controller Installation Guide. Rev

DIGITAL LIGHT CONTROLLER

FEC400 Series. Installation Manual

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SWING GATE OPERATOR

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Dishwasher Cycle Chart Condensation Dry System

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

LeakSafe. solutions. WaterSwitch2. Installation Instructions

M2500 Engine Controller Installation Manual

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

EXTINGUISHING AGENT RELEASE MODULE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

CX-29. Section 1 General Description. Section 2 Installation. Besam Switching Network & Bi-Directional Door Sequencer Installation Instructions

Remote Chexit Module (RCM) System. General Information

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

WC Series Vended Washers Troubleshooting, and Fault Codes

SAFETY INFORMATION AND WARNINGS

Carbon Monoxide Transmitter

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

Remote NAC Power Supply D7038

TEXAS DEPARTMENT OF TRANSPORTATION DEPARTMENTAL SPECIFICATION TO-6043 DIGITAL LOOP VEHICLE DETECTOR UNIT

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR

QA16 Addressable System

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

MR-2602 Two Zone Fire Alarm Control Panel

Transcription:

D-TEK LM Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death! For more information, please visit www.devancocanada.com or call toll free at 855-931-3334

Product Overview The D-TEK LM TM Vehicle Loop Detector allows for detection of metallic objects entering into the field formed around the detection loop. We have designed the D-TEK with the following objectives in mind: 1. Conformal coated board to provide environmental protection. 2. All controls are accessible for easy installation and operation. 3. Integral loop conditioner is provided, to enable detector operation with marginal loops. 4. Provide all features and controls necessary for a variety of applications. 5. Provide maximum surge protection on all inputs and outputs of the detector. We took extra care to achieve and exceed these objectives. For example the controls are simple and easy to understand. The D-TEK PCB-1 switches have gold plated contacts that are sealed for protection. The circuit is protected by an advanced thermal resettable fuse, snubbing circuitry on the relay contacts, Metal Oxide Varistor on the power input and triple protection on the loop input. The D-TEK features are extensive and include full loop diagnostic with frequency counter, 10 sensitivity settings, delay and extend features, automatic sensitivity boost, pulse or two presence relay operation and more. Technical Specifications Power Supply 24 Volt AC Power Supply Tolerance +/- 20% of power rating Current Draw 100 ma maximum Dimensions W=4.5 (114mm), L=3.2 (80mm) Relay Type (2) DPST 5A@ 125VAC Temperature Range -40 to 180 Degrees Fahrenheit Connector 10 Pin Male Molex Header 09-72-2101 or 09-62-3101 Loop Inductance Range 20 to 2000 micro henries with Q factor of 5 or higher Loop Input Transformer Isolated Power On Indicator Green T-1 LED Detect Indicator Red T-1¾ LED Surge Protection MOV, Neon and Silicon Protection Devices Tuning Detector automatically tunes to the loop after power application or reset Tracking Detector automatically tracks and compensates for environmental changes Environmental Protection Circuit board is conformal coated to resist moisture Frequency Counter Counts Loop frequency, each blink represents 10KHz. Counts between 3 to 13 blinks confirm that the detector is tuned to the loop. Power Indicator Solid lighted green LED indicates power Loop Failure Indicator Slow blinking green LED indicates loop failure Loop Failure Memory Fast consecutive green blinking LED indicates past loop problem that healed Detect Indicator Solid lighted red LED indicates detection Extend Indicator Blinking red LED after vehicle leaves the loop indicates time extend 4 minute limit Blinking red LED during vehicle detection indicates that 4 minute limit has expired. D-TEK LM Operating Instructions 2

Controls, Indicators and Connections POWER LED SENSITIVITY BCD Switch Green T-1 Glows when power is applied DETECT LED Red T-1¾ Glows to indicated detection FREQUENCY COUNTER RESET Momentary Switch Push Test momentarily to activate Momentary Switch Push down momentarily and release to reset FREQUENCY DIP Switches 9 & 10 Low, Medium Low, Medium High, High Unit must be reset after any change! 0,1,2,3,4,5,6,7,8,9 must be on a number DIP SWITCH FUNCTIONS Dip Switch OFF ON 1 Extend Detect 3 seconds 2 Extend Detect 6 seconds 3 ASB OFF ASB ON 4 Filter OFF Filter On 5 Reserved 6 Constant Presence 4 Minute Limit 7 Pulse on Detect Pulse on Un-detect 8 Pulse on Relay 2 Presence on Relay 2 9 Loop Frequency Control 10 Loop Frequency Control *When DIP 1& 2 are both on time is 9 seconds ASB = Automatic Sensitivity Boost LOOP FREQUENCY SETTINGS Loop Frequency High Medium High Medium Low Low DIP 9 Off Off On On DIP 10 Off On Off On CONNECTIONS 10 PIN PIN FUNCTION HARNESS 1 Relay Output No2. COM BLUE 2 Relay Output No. 2 N/O ORANGE 3 Relay Output No. 2 N/C YELLOW 4 Relay Output No. 1COM GREEN 5* Relay Output No. 1 N/C RED 6* Relay Output No. 1 N/O PINK 7 POWER COM WHITE 8 POWER + BLACK 9 Loop BROWN 10 Loop GRAY * NOTE: Mounting hole with pad must be connected to earth ground for surge protection to be effective. ** NOTE: Functions on pins 5 and 6 are reversed if DIP switch 5 is set to OFF Fail Secure operation Ground * Must be connected to earth ground for surge protection to be effective D-TEK LM Operating Instructions 3

Installation 1. Connect the D-TEK to appropriate power supply as marked on the label of the detector on pins 7 and 8 according to the connection chart on page 3 of this manual. 2. Connect the loop wires to pins 9 & 10 (Brown and Gray wires in harness) The D-TEK PCB-1 must be connected to a loop meeting the appropriate requirement listed on page 2. 3. Connect the desired relay outputs to the operator control board inputs. Relay 1 is a Constant Presence and Relay 2 is Pulse or Constant Presence. 4. Adjust sensitivity to desired level to assure detection of all vehicle traffic. Factory set is normally 3 or 4. 5. Mounting hole with silver pad must be connected to earth ground for effective surge protection. 6. Do not install the loop wire near or parallel to: a. Low voltage lighting. b. Telephone lines. c. Underground power lines. d. Electrical pavement heaters. e. Cell phone towers or radio communication systems. f. Overhead power lines. g. Transformers. 7. To install the loop into new concrete with re-bar or wire mesh we recommend that the loops be installed at least 1 inch above the re-bar. 8. When installing in saw cut we recommend the use of backer rod and a good grade sealant for the type of surface. Operational settings explained 1. Reset Switch- when this switch is momentarily pressed down and released will cause the D-TEK to reboot. 2. Frequency Switches- DIP switches 9 and 10 are used to change the loop operation frequency to High, Medium High, Medium Low or Low. This helps to prevent cross talk with adjacent loops and possible interference from other sources in the same operational frequency. Note: When the frequency is changed the D-TEK must be re-set. (Page 3) 3. Frequency Counter- when this switch is momentarily pushed it will cause the detector to blink the red Detect LED. Each blink of the LED indicates a frequency multiple of 10 KHz. (example 5 blinks = 50 KHz.) Counts from 3 to 13 confirm that the detector has tuned to the loop. D-TEK LM Operating Instructions 4

4. Sensitivity- this rotary switch controls the detector sensitivity. During normal operation the sensitivity setting is 3 or 4. Note: the higher the sensitivity the more prone the detector will be to interference. To increase detection height without increasing the detector sensitivity settings, increase the size of the loop. Detection height is roughly 70% of the shortest side of the loop. (example 4 x 8 loop = approximately 33 inch detection height and a 6 x 8 loop = approximately 50 inch detection height.) 5. ASB- Automatic Sensitivity Boost is activated by DIP switch 3 on the detector. This allows the detector to be set at a standby sensitivity and when detection occurs sets the sensitivity to maximum until the unit undetects. This allows for the use on high bed vehicles that might otherwise un-detect while still in the loop. 6. Pulse/Presence relay 2- this feature is controlled by DIP switch 8 on the detector and allows relay 2 to act in the pulse mode or as a second presence mode relay mimicking relay 1. 7. Pulse Detect/Un-detect- this feature is controlled by DIP switch 7 on the detector. Allows for activation on entering into the loop or exiting from the loop. 8. Constant Presence / 4 minute limit- this feature is controlled by DIP switch 6 on the detector and allows for the detector to hold the activation for as long as any vehicle is in the detection loop or to allow the relay to deactivate after 4 minutes. Warning! DO NOT USE 4 minute limit unless opening is protected by a secondary safety device such as the IRB-4X. 9. Filter- this function is controlled by DIP switch 4 on the detector. This feature inputs a momentary delay into the detection circuit to verify that a vehicle is present in the loop for a minimum time period before activation occurs. 10. Extend Detect- this feature is controlled by DIP switches 1 and 2 detector. Turning on switch 2 allows for a 6 second extension of the detection after the vehicle leaves the loop. Turning on switch 1 allows for a 3 second extension of the detection after the vehicle leaves the loop. Turning on both switches 1 and 2 allows for a 9 second extension of the detection after the vehicle leaves the loop. D-TEK LM Operating Instructions 5

TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SOLUTION Green Indicator is not lit No input voltage 1. Check voltage on pins 7 and 8. 2. Check wiring to detector. 3. Verify voltage used matches voltage marked on unit. Green Indicator flashes Loop wire shorted or disconnected Check loop resistance on pins 9 and 10, it should be less than 5 ohms and more than 0.5 ohms. Green Indicator flashes with two consecutive fast blinks Detector stays in detect mode after the vehicle leaves the loop and fails to un-detect. Detector detects intermittently even when there is no vehicle on the loop. Loop wire was temporarily shorted or disconnected 1. Faulty Loop. 2. Poorly crimped connections 3. Loose connections 1. Faulty Loop 2. Poorly crimped terminals 3. Loose connections 4. Cross-talk between adjacent loop detectors 5. Loop not securely installed to prevent movement of wire in pavement Check loop resistance on pins 9 and 10, it should be less than 5 ohms and more than 0.5 ohms. The reading should be steady. 1. Perform megger test between loop lead and ground, the reading should be greater than 100 Mega ohms. 2. Check that loop is tightly connected to proper terminals 3. Check that splices are tightly soldered and sealed against moisture 1. Perform megger test between loop lead and ground, the reading should be greater than 100 mega ohms. 2. Check that loop is tightly connected to terminals 3. Check that splices are tightly soldered and sealed against moisture. 4. Set adjacent loops to different frequencies. 5. Verify that loop is securely installed in pavement and that site is in good condition preventing movement of loop wires. D-TEK LM Operating Instructions 6

Ordering Information D-TEK-LM Circuit board detector for Liftmaster operators 24 VAC Accessories PR-XX EMX Lite-preformed loop with 50 ft. lead wire standard (XX = loop size example 48 = 4x8) HAR-7 10 Pin Female wire harness with 3 ft. of wire Installer notes: Voltage installed: DIP switches turned on: Sensitivity setting: Frequency setting: D-TEK LM Operating Instructions 7

HOW TO ORDER REPAIR PARTS DEVANCO CANADA 19192 HAY ROAD, UNIT Q SUMMERSTOWN, ON K0C 2E0 TOLL FREE: 855-931-3334 www.devancocanada.com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: 3 PART NUMBER 3 DESCRIPTION 3 MODEL NUMBER