ENGINEERED PARKING SYSTEMS MODEL 3416D

Similar documents
D-TEK -MS Vehicle Loop Detector. Operating Instructions

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Operating Instructions

Operating Instructions

Operating Instructions

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

For more information, please visit or call toll free at

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Operating Instructions

MD12-2 Vehicle Loop Detector

MD12-1 Vehicle Loop Detector

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

DSP-13 Tri-Axis Detection (TRIAD TM ) System

Remote NAC Power Supply D7038

Installation, Operating and Maintenance Manual

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

KP: Charge Air Cooler (CAC) Pump

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

MODEL B2 INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Overload LED On & Power LED On

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

Secure the other corner. bracket using the remaining screw,

TEXAS DEPARTMENT OF TRANSPORTATION DEPARTMENTAL SPECIFICATION TO-6043 DIGITAL LOOP VEHICLE DETECTOR UNIT

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

S AFETY SYSTEMS TECHNOLOGY Mill Creek Drive, Suite 215 Laguna Hills, California 92653, USA Tel (949) Fax (909)

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

LC3000 Level Controller Installation and Maintenance Instructions

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

3510 East Atlanta Avenue, Phoenix, AZ USA

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

RELEASE DEVICE CONTROLS

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

WARNING FIRE DOOR CLOSING

V-MUL-033(A0) RADIOLINK BASE

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

GS100M Gas Detector. Technical Specification

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

AL800ULADA. NAC Power Extender. Installation Guide

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

QA16 Addressable System

Safety Photo Beam UL MONITORED DEVICE

Pioneer-R16 Gas Monitor Operator s Manual

M2500 Engine Controller Installation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MANUAL RESET ALARM RELEASE BOX

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

Stratomaster Smart Single

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

INSTALLATION AND INSTRUCTION MANUAL

Description. Optex Incorporated

SAFETY INFORMATION AND WARNINGS

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Dishwasher Cycle Chart Condensation Dry System

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Part 3 Troubleshooting

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

C-Bus Four Channel Analogue Output Unit Installation Instructions

5000 SERIES 8 ZONE INSTRUCTION MANUAL

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

AO Annunciator Module

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

REMOTE CONTROL CAR ALARM SYSTEM

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Transcription:

ENGINEERED PARKING SYSTEMS MODEL 3416D Vehicle Loop Detector Operating Instructions ENGINEERED PARKING SYSTEMS 25010 AVENUE TIBBITTS VALENCIA, CA 91355 (661) 294-0778, (800) 377-4636 www.epsinfo.com

We have designed the new Model 3416D D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow easy installation into small operator housings. 2. All the controls are accessible from the outside for easy installation and operation. 3. Integral loop conditioner is provided, to enable detector operation with marginal loops. 4. Provide all the features and controls necessary for a variety of applications. 5. Use metal housing for maximum durability and RF blocking. 6. Provide maximum surge protection on all inputs and outputs of the detector. We took extra care to achieve and exceed these objectives. For example the controls are divided into two groups. The group on the front of the detector is for basic operation and the group on the back of the detector is for advanced settings. This way the more advanced settings are not visible to the casual user. There is no skimping on the quality in the D-TEK detector. The housing is made from aircraft quality anodized aluminum. All the switches have gold plated contacts and are sealed for protection. The detector is protected by easily replaceable fuse, snubbing circuitry on the relay contacts, metal oxide varistor on the power input and triple protection on the loop input. The D-TEK features are extensive and they include full loop diagnostics with frequency counter, 10 sensitivity settings, delay and extend features, "fail safe" and "fail secure" operation, automatic sensitivity boost, pulse or two presence relay operation and more. Technical Information Detector Connections Pin Function Harness A Power White B Presence relay Common Yellow C Power Black D Loop Grey E Loop Brown F Presence relay N.O. Blue G Presence relay N.C. Red H Chassis Ground Green I Relay 2 Common Pink or Blk/White J Relay 2 N.O. Purple or Red/White Connections are shown with Dip Switch #4 ON and no vehicle pesent. Front Indicators 1. Green Led is ON - the detector is powered. 2. Red Led is ON - the detector detected a vehicle 3. Green Led is Blinking - the loop failed and is shorted or disconnected 4. Green Led is Blinking with two consecutive fast blinks - the loop failed in the past and now is working correctly. 5. Red Led is Blinking at the start of a vehicle detection - the Filter function is ON 6. Red Led is Blinking at the end of a vehicle detection - the Extend function is ON 7. Red Led is Blinking during a vehicle detection - 4 minute limited presence time has expired.

Technical Specifications Power: the detector is available in the following voltages, 110V AC, maximum current draw 100mA. Low power detector is available with maximum current draw of 60mA Temperature: -40F to + 180F Environmental Protection: Circuit board is conformal coated Enclosure: Extruded anodized aluminum, Height = 3.25 inches 83 mm Width = 2.56 inches 40 mm Depth = 3.65 inches 90 mm Output Relays:5A/125 V AC standard version, 1A/125 V AC low current version Connector: MS compatible with 10pin Military Threaded wire harness. Surge Protection: The detector is protectedwith neon discharge lamps, zenner diodes and surge arrestors. Loop Input:Transformer isotated Grounded Loop: The loop isolation transformer allows operation with poor quality loops. Loop Inductance Range: 20 to 2000 microhenries with Q factor of 5 or higher. Tuning:Detector automatically tunes to the loop after power application or reset. Tracking: Detector automatically tracks and compensates for environmental changes Power Indicator: Green LED solid light indicates power Loop Failure Indicator: Green LED blinks indicates loop problem Loop Failure Memory: Green LED blinks with fast consecutive blinks indicates past loop problem that healed. Detect Indicator: Red LED solid light indicates detection Extend Indicator: Red LED blinks after a car left the loop indicates time Extend feature Sensitivity: is set by 10 position rotary switch Frequency: is set three position toggle switch Infinite Presence Mode: DIP switch selectable presence Limited 4 Minutes Presence Time: DIP switch selectable Second Presence Relay: DIP switch selectable Pulse On Exit / Entry: DIP switch selectable Fail Safe / Secure : DIP switch selectable Filter: DIP switch selectable 2 seconds Exteded Detection: DIP switch selectable 3, 6 and 9 seconds Front Controls Reset This toggle switch when pushed momentarily down will reset the detector Frequency Counter This toggle switch when pushed momentarily up will count the frequency on the loop. This count is displayed by the Red Led blinks, each blink represents frequency of 10K Hz. Count between 3 to 13 blinks confirms that the loop detector is tuned to the loop. Frequency This toggle switch controls the loop frequency. Set different frequencies on adjacent loops. Verify frequencies with the frequency counter by counting the Red LED blinks.

Back Controls Sensitivity This rotary switch controls the detector sensitivity. During normal operation the sensitivity level is set to 3 or 4. DIP Switch Functions DIP OFF ON 1 Pulse on Relay II Presence on Relay II 2 Pulse on detect Pulse on Un-detect 3 Constant presence 4 minute limited presence time 4 "Fail Secure" "Fail Safe" 5 Filter Off Filter On 6 ASB Off Automatic Sensitivity Boost On 7 Extend detect 6 seconds 8 Extend detect 3 seconds (When Dip7 and 8 are in ON position the extend time is 9 seconds.) Warning: Do not use limited presence setting and / or "Fail Secure" setting for reversing gates, doors or barriers. DIP - Detector Functions 1. Presence function is provided always by the presence relay output on pins 5, 6, and 10. These outputs are active when the detector detects a car. If there is a need for an additional presence output the Relay 2 can be configured as a second presence output by setting DIP 1 to ON position. 2. Pulse function is provided by the Relay 2 output on pins 3, 9, and 11. To obtain pulse on Relay 2 set DIP 1 to OFF position. The pulse of about 0.5 second can be generated when the car enters the loop or when it exits. To generate pulse on vehicle entry to the loop set DIP 2 to OFF position. To generate pulse on vehicle exit from the loop set DIP 2 to ON position. 3. The presence relay provides constant output as long as the car is detected on the loop. To obtain constant presence time set DIP 3 to OFF position. In some applications limited presence time is required. To obtain limited presence time of approximately 4 minutes set DIP 3 to ON position. Be aware that the detector relay will be released after 4 minutes even if the vehicle is still detected by the detector. This may by a serious hazard in applications where gates, doors or barriers are reversed, therefore never use this option in these applications. 4. When DIP 4 is set to ON position the detector works in "Fail Safe" mode of operation the detector will issue a detect signal when a car is detected, loop is disconnected or shorted, or when the power to the detector is interrupted. It is strongly recommended to use the detector in this mode. In some application there is a need to ignore the loop or power failures and only to provide the detect signal when a car is detected on the loop. To ignore loop or power failures set the detector to "Fail Secure" by setting DIP 4 to OFF position. Do not use this setting for application where gates, doors or barriers have to be reversed. Note: Functions on pins B and G are reversed if DIP 4 is set to OFF 5. In some applications it is necessary to filter out short detections such as cross traffic or short burst of radio frequency such as keying of a CB transmitter. To ignore these short detections set DIP 5 to ON position. This will cause any detection that is shorter than 2 seconds to be ignored. 6. To increase detection height when detecting high bed vehicles set DIP 6 to ON position. This setting will cause the sensitivity to automatically increase once the front axle of the truck is detected. The sensitivity will go back to the normal level once the truck left the loop. 7. To extend the presence output for 6 seconds after the vehicle left the loop set DIP 7to ON position. 8. To extend the presence output for 3 seconds after the vehicle left the loop set DIP 8 to ON position. Note: If DIP Switch 7 and DIP Switch 8 are set to ON position the presence output will be extended 9 seconds after the vehicle leaves the loop.

Trouble Shooting Symptom Possible Cause Correction Green indicator is not ON No input voltage Green indicator flashes Loop wire shorted or disconnected Green indicator flashes with two consecutive fast blinks Detector stays in detect mode after the car left the loop and fails to undetect. Loop wire was temporarily shorted or disconnected 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 1. Check voltage on pins 1 and 2. 2. Replace internal fuse 3. Check wiring to detector 1. Check loop resistance on pins D and E it should be less than 5 ohms and more than 0.5 ohms. 1. Check loop resistance on pins D and E while driving over the loop it should be less than 5 ohms and more than 0.5 ohms. The reading should be steady. 1. Perform megger test between loop lead and ground the reading should be larger than 100 megaohms. 2. Check that loop is tightly connected to proper terminals 3. Check that splices are tightly soldered and sealed against moisture. Detector detects intermittently even when there is no car on the loop. 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 4. Cross-talk between adjacent loop detectors 1. Perform megger test between loop lead and ground the reading should be larger than 100 megaohms. 2. Check that loop is tightly connected to proper terminals 3. Check that splices are tightly soldered and sealed against moisture. 4. Set adjacent loops on different frequencies.