CHAPTER 15 VEHICLE DETECTION

Similar documents
Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

EMERGENCY VEHICLE PREEMPTION (EVP) OPTICAL EMITTER ACTIVIATED EVP SYSTEM

CHAPTER 20 SERVICE EQUIPMENT

FLEXIBLE DUCTS BY SUBSURFACE INSTALLATION FOR MAGNETIC DETECTORS - Item No. RIGID DUCTS, CONCRETE ENCASED FOR MAGNETIC DETECTORS - Item No.

Section 600 Overview. Section 603 General Requirements for Installation and Evaluation of Traffic Control Equipment and Materials

SECTION STREET LIGHTING AND TRAFFIC SIGNALS Replace this section with the following:

SECTION 49 SIGNALS, LIGHTING AND ELECTRICAL SYSTEMS TABLE OF CONTENTS

City of Vista Fire Department

SIGNALS, LIGHTING AND ELECTRICAL SYSTEMS

FEB 2016 COUNTY MAP NTS

Transportation Systems and Utility Infrastructure

DSP-13 Tri-Axis Detection (TRIAD TM ) System

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Nuts and Bolts (or Gravel and Asphalt) of the Main Street Project

Owner's Manual. WS Series. Water Softener

Technical Bullet Series on Clay Brick Pavers

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Regulatory Reform (Fire Safety) Order 2005

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions

10ft Wide Polytunnel Assembly Instructions

E kv Transmission Line Underground Relocation Project. Initial Evaluation of Bridge Structures

Installation Instructions

730K TDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION January 1, 2015

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

218 Trademark Dr Buda Texas STL Boss 200 Watt Siren Operation Manual and Instructions

Te c h S p e c 3. Edge Restraints for Interlocking Concrete Pavements

T_01 Cover.DGN 5/10/ :51:40 AM

Inde-Pendants Family. 32L Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Operating Instructions

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

For more information, please visit or call toll free at

DESIGN SCENE SUBJECT INDEX

Vehicle Detection. Brief history of each detection. How they work. Discuss most used ones. Are other options

Monroe Street Reconstruction. Public Preconstruction Meeting February 21, 2018

LED Flex Tube Assembly Guide

CITY OF OZARK STANDARD DRAWING DETAILS FOR PUBLIC IMPROVEMENTS

SECTION ELECTRICAL IDENTIFICATION

Operating Instructions

WILDLIFE DETECTION AND ACTIVE WARNING SYSTEM SYSTEM OPERATIONS SUMMARY

APPENDIX G: TOWN ORDINANCE REVIEW

Handshower, Hose & Handshower Accessories

218 Trademark Dr Buda Texas STL Apex 150 Watt Siren Operation Manual and Instructions

SECTION (15530) - REFRIGERANT PIPING

CHAPTER 14: GUARDRAIL and BARRIERS

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Operating Instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

SILT FENCE MACHINE SLICED ERO-1A STEEL FENCE POST (T-POST), MINIMUM 5' LONG, 6' MAXIMUM SPACING.

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

1SC-SSC Splice Connection Kit Installation Instructions

2. HORIZONTAL DATUM = NAD 83. VERTICAL DATUM = NAVD 88.

BOARD OF SUPERVISORS BUSINESS MEETING ACTION ITEM

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

3510 East Atlanta Avenue, Phoenix, AZ USA

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

RKA-LEL Sample Draw Combustible Gas Detector

Woodbridge Addition Driveway Separation

Installation Instructions

Data Sheet. Self regulating heating tapes. RS stock numbers

Oahu Showerspa Model #1035 Owner's Manual

KR Electrical Defrost Unit Coolers (PN E108318_E)

New Construction Fire Inspection Process

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Installation Instructions

Acrylic Claw Foot Tub

6ft Wide Polytunnel Assembly Instructions

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

Oscillating Ceiling Fan

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Get it Right the First Time Avoid These Commonly Cited Errors

VILLAGE OF MOUNT PROSPECT 2016 STREET RESURFACING PROGRAM Frequently Asked Questions (FAQ s)

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Installation Instructions for. CattleMaster Series Fountains

INSTALLATION & OPERATING INSTRUCTIONS

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

GENERAL. Model 2SD UAI-A Before installing read all of the manufacturers installation and maintenance instructions.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Hanson LED C e i l i n g F a n

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Installation Manual January Canoga Traffic Sensing System Model 702 Non-Invasive Microloop

MODEL RWM RADIATION WASTE MONITOR LUDLUM MODEL RWM RADIATION WASTE MONITOR INSTALLATION MANUAL

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

5 Inch Speed Dome Installation Manual V2.0.0

Household devices, <-<>al breaker rolls, stone crusher, four early types of power devices.

FAN POWERED VAV TERMINALS

Installation Instructions

Main Street Reconstruction From Ninth Line to Stouffer Street. Town of Whitchurch-Stouffville. Public Information Centre

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Transcription:

CHAPTER 15 VEHICLE DETECTION VEHICLE DETECTION Vehicle detectors act as the eyes of the traffic signal controller thereby allowing it to become traffic responsive. The loss of even one vehicle detector could greatly disrupt the timing of the signal resulting in traffic backup. Because vehicle detection is a vital part of the traffic control signal system, great care must be exerted when installing vehicle detectors. Locations of vehicle detectors range from at or near the stop line to up to 750 feet back from the stop line. It is necessary to locate lane markings and crosswalks to correctly locate vehicle detectors that are in the pavement. Vehicle detectors should be marked after pavement markings have been determined or placed. Other types of detector units (video, microwave, sonic) will need to be located per the contract documents, manufacturer s instructions, and/or as directed by the engineer. Vehicle loop detector materials, installation requirements, approved loop detector conductors, test reports, requirements for inductance, and number of turns will be identified within the contract documents. MnDOT approved loop sealants and MnDOT approved loop detector splice encapsulation kits are listed on MnDOT s Approved/Qualified Products List (APL). 15.1 Types of There are four different types of vehicle detection used by MnDOT on traffic control signal system projects. The contractor must refer to the contract documents for the type of vehicle detection system that is required for the specific traffic control signal project. The four types are presented below: Preformed rigid PVC conduit loop detectors Saw cut loop detectors Video detectors Microwave and sonic detectors Figure 15-1: Detectors in Pavement 15-1

15.1.1 PREFORMED RIGID PVC CONDUIT LOOP DETECTORS Preformed rigid PVC conduit loop detectors are the most common type of vehicle detector that MnDOT currently uses on a typical traffic control signal system project. Standard Plate 8132 will have all the requirements for a complete installation of this type of detector. These types of detectors are either placed in the class 5 roadway base before pavement installation or they may be required to be milled into the existing pavement. Figure 15-2: Preformed Rigid PVC Conduit Loop Detectors Figure 15-3: Preformed Rigid PVC Conduit Loop Detector 15.1.2 SAW CUT LOOP DETECTORS When saw cut loop detectors are required, the requirements are on Standard Plate 8130. The steps presented below should be taken for saw cut loop detectors. Mark loop detectors and loop conduit locations on the pavement. If necessary, adjust the location of the loops to avoid cracks and joints in the pavement. If cracks or pavement joints are encountered, refer to Standard Plate 8130 for complete details of installation requirements. Install loop detectors in the roadway before bituminous wearing course is placed. Figure 15-4: Saw Cut Loop Detectors 15-2

It is essential to maintain required depth of trench or saw cut throughout, including the corners of the loop, to ensure the loops will survive future roadway milling operations. After sawing and drilling is complete, clean all foreign materials from loop detector saw cuts. Dry sawing does not require water flushing. Figure 15-5: Air Flushing Before installation of loop detector conductors, a bead of MnDOT-approved loop detector sealant must be placed in the saw cut. Ensure that the dowels are installed in the corners of the saw cut prior to winding the loop detector conductor. Install clean, dry, continuous loop detector conductor wound in a clockwise direction allowing 6 extra feet of conductor within the handhole. Lay the loop detector wire in the saw cut and push them to the bottom of the saw cut with a blunt instrument to avoid damaging the tubing or conductors. Figure 15-6: Water Flush Saw Cuts Figure 15-7: Placing Saw Cut Loop Detector Conductor Install 1/2-inch diameter by 1 inch backer rods at 24 inch intervals to ensure that the conductors remain at the bottom of the saw cut. Figure 15-8: Backer Rod Installation 15-3

After all sawing and drilling is complete, clean and flush all foreign materials from loop detector saw cuts and general area of loop detector using a high-pressure air and water mix. Dry all loop detector saw cuts and general loop area prior to installation of sealant and conductors. Loop wire must be clean when it is installed. If necessary place loop wire in a plastic bag to ensure it remains clean. Twist the loop conductor pairs for the entire length of the loop detector lead-in conduit at a minimum rate of three turns per foot. Seal the loop detector conduit at the roadway end with duct seal to prevent loop sealant from entering the conduit. Test the loop before the sealant is placed in the saw cut. Seal saw cut loop conductors with an approved loop detector sealant (see MnDOT s APL) as per manufacturer s recommended procedures. Do not overfill the saw cut with sealant. 15.1.3 HANDHOLE CONSIDERATIONS FOR BOTH SAW CUT AND PREFORMED LOOPS To run the loop wire to the handhole, it is necessary to install a conduit from the road surface to the handhole. Drill a hole a minimum of 18 inches from the curb apron or edge of pavement or joint between the road and the shoulder at an approximate 45-degree angle at the intersection of the loop saw cuts. The hole must be large enough to install 1-1/4 inch PVC conduit or rigid steel conduit (RSC). A ¾ inch PVC or RSC is acceptable when installing a single loop. Ream the end of the conduit so that the insulation on the wires is not damaged during installation. The conduit must be inserted far enough into the hole so that the bottom is one inch below the bottom of the saw cut. When installing preformed rigid PVC loops, the conduit must be continuous from the loop to the handhole. Install a conduit end bell bushing on the handhole end of the conduit. It is necessary to place a one inch metallic washer over the roadway end of the lead-in conduit so that the lead-in conduit can be found if the loop goes dead. Figure 15-9: Seal the Conduit Figure 15-10: Approved Sealant Figure 15-11: Loop Detector Cable Splices Figure 15-12: Roadway to Handhole Conduit Figure 15-13: Drill Hole for Conduit 15-4

15.1.4 PVC AND SAW CUT LOOP DETECTOR SPLICING The steps to PVC and saw cut loop detector splicing include the following: Properly prepare and clean the loop detector conductors. The ends of the roadway loop detector conductors are to be soldered to the loop detector lead-in cable. After being soldered, install an appropriate sized wire nut and scuff the conductor insulation with the provided emery cloth before splice kit installation. Splice the loop detector conductors according to the approved method and approved splice kit. (See contract documents for approved splice kit and splicing method). Loop detector splice kits must be installed in a manner to ensure that they are suspended and secured near the top of the handhole so that they are accessible if water freezes in the handhole. Testing The steps to PVC and saw cut loop detector testing include the following: Test each loop detector in accordance with 2565.3G. Figure 15-14: Suspended Splice Kits The loops must be tested for resistance, inductance and a Meg Ω reading to ground at the signal cabinet. The test results must be recorded on a form similar to the one found in the Appendix of this Field Guide. Three copies of the report must be given to the project engineer for distribution (signal cabinet, ESS, and the district traffic office). Figure 15-15: Detector Testing If the readings are not within the design parameters, there is a problem with the installation, or materials, and the loop will have to be reinstalled. These procedures will ensure a good functioning loop detector. Refer to contract documents for complete details on loop materials, installation, and testing. 15-5

15.1.5 VIDEO DETECTION SYSTEMS Some MnDOT projects will require video detection systems. All material and installation requirements for video detection systems are contained in the contract documents. Figure 15-16: Video Detection 15.1.6 MICROWAVE AND SONIC DETECTORS Microwave and sonic detector units are used on temporary span wire type traffic control signal systems. The contractor must refer to the contract documents for location and installation requirements for these vehicle detector types. Figure 15-17: Microwave and Sonic Detectors 15.2 Chapter 15 Resources Standard Plates 8130, 8132 MnDOT s Approved/Qualified Products List (APL) 15-6