MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Similar documents
D-TEK -MS Vehicle Loop Detector. Operating Instructions

ENGINEERED PARKING SYSTEMS MODEL 3416D

Operating Instructions

Operating Instructions

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

For more information, please visit or call toll free at

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Operating Instructions

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

DSP-13 Tri-Axis Detection (TRIAD TM ) System

MD12-2 Vehicle Loop Detector

Installation, Operating and Maintenance Manual

MD12-1 Vehicle Loop Detector

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

C-Bus Four Channel Analogue Output Unit Installation Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

C-Bus Four Channel General Input Unit Installation Instructions

RELEASE DEVICE CONTROLS

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

S AFETY SYSTEMS TECHNOLOGY Mill Creek Drive, Suite 215 Laguna Hills, California 92653, USA Tel (949) Fax (909)

INPUT / OUTPUT MINI MODULES

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

MODEL B2 INSTALLATION MANUAL

Emerald 3000 MK3 GJD010 Lighting Controller

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

MTRA-FSP Level Control Relay. Installation & Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Power Supply Display Module PSDM. Installation and Operation Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Overload LED On & Power LED On

Operating Instructions. For. Alarm Control Module. Model SSR 500

Pioneer-R16 Gas Monitor Operator s Manual

GS100M Gas Detector. Technical Specification

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

MANUAL RESET ALARM RELEASE BOX

4 Channel Contact Closure SFP DIN Fiber Link System

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Remote NAC Power Supply D7038

INTRODUCTION / TABLE OF CONTENTS

Installation and Operation Guide for the UPS-64C Power Supply with CometFlash

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

AL800ULADA. NAC Power Extender. Installation Guide

LC3000 Level Controller Installation and Maintenance Instructions

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

BX444-Mc Gas Detector

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

4 & 8-POINT ANNUNCIATORS Instruction Manual

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Safety Photo Beam UL MONITORED DEVICE

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

TEXAS DEPARTMENT OF TRANSPORTATION DEPARTMENTAL SPECIFICATION TO-6043 DIGITAL LOOP VEHICLE DETECTOR UNIT

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

KP: Charge Air Cooler (CAC) Pump

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Reflective Optical Beam Smoke Detector User Guide

TECHNICAL DATA OBSOLETE

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Dishwasher Cycle Chart Condensation Dry System

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Carbon Monoxide Transmitter

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless testing requires power.

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

AlarmLine Linear Heat Detector

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Technical Manual. Level Alarm Unit CARLA & WIDS

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Transcription:

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC Operating Instructions

We have designed the new MVP-D-TEK vehicle loop detector with the following objectives in mind: 1. Compact package to allow easy installation into small operator housings. 2. All the controls are accessible from the outside for easy installation and operation. 3. Integral loop conditioner is provided, to enable detector operation with marginal loops. 4. Provide all the features and controls necessary for a variety of applications. 5. Use metal housing for maximum durability and RF blocking. 6. Provide maximum surge protection on all inputs and outputs of the detector. We took extra care to achieve and exceed these objectives. For example the controls are divided into two groups. The group on the front of the detector is for basic operation and the group on the back of the detector is for advanced settings. This way the more advanced settings are not visible to the casual user. There is no skimping on the quality in the MVP-D-TEK detector. The housing is made from aircraft quality anodized aluminum. All the switches have gold plated contacts and are sealed for protection. The detector is protected by a thermal resettable fuse, snubbing circuitry on the relay contacts, metal oxide varistor on the power input and triple protection on the loop input. The MVP-D-TEK features are extensive and they include full loop diagnostics with frequency counter, 10 sensitivity settings, delay and extend features, "fail safe" and "fail secure" operation, automatic sensitivity boost, pulse or two presence relay operation and more. Technical Information Detector Connections Pin Function Harness 1 Power 9V DC - 240V AC White 2 Power Black 3 Relay 2 N.O Orange 4 Ground Green 5 Presence Relay Comm. Yellow 6 Presence Relay N.O. Blue 7 Loop Gray 8 Loop Brown 9 Relay 2 Comm.. Red 10 Presence Relay N.C. Pink 11 Relay 2 N.C. Violet Note: Functions on pins 6 and 10 are reversed if DIP 4 is set to OFF "Fail Secure" operation

Technical Specifications Power: The MVP detector operates across the 9V DC - 240V AC power range. Current Consumption: 19.2 ma @ 9 VDC 18.8 ma @ 12 VDC 17.3mA @ 24 VAC 9.5 ma @ 24 VDC 13.5 ma @ 115 VAC 11.0 ma @ 237 VAC Temperature: Environmental Protection: Enclosure: Output Relays: Connector: Surge Protection: Loop Input: Grounded Loop: Loop Inductance Range: Tuning: Tracking: Power Indicator: Loop Failure Indicator: Loop Failure Memory: Detect Indicator: Extend Indicator: Sensitivity: Frequency: Infinite Presence Mode: Limited 4 Minutes Presence Time: Second Presence Relay: Pulse On Exit / Entry: Fail Safe / Secure : Filter: Exteded Detection: -40F to + 180F Circuit board is conformally coated Extruded anodized aluminum, Height = 3.25 inches 83 mm Width = 2.56 inches 40 mm Depth = 3.65 inches 90 mm 1A/30V DC 86CP11 compatible with 11pin Octal DIN rail mountable socket or wire harness The detector is protected with neon discharge lamps, zenner diodes and surge arrestors. Transformer isotated The loop isolation transformer allows operation with poor quality loops. 20 to 2000 microhenries with Q factor of 5 or higher. Detector automatically tunes to the loop after power application or reset. Detector automatically tracks and compensates for environmental changes Green LED solid light indicates power Green LED blinks indicates loop problem. DIP switch 4 set to fail secure, Relay 2 may be used to act as loop failure output to control board. Green LED blinks with fast consecutive blinks indicates past loop problem that healed. Red LED solid light indicates detection Red LED blinks after a car left the loop indicates time extend feature Set by ten position rotary switch Set by three position toggle switch presence 2 seconds 3, 6 and 9 seconds

Front Indicators 1. Green Led is ON - the detector is powered. 2. Red Led is ON - the detector detected a vehicle 3. Green Led is Blinking - the loop failed and is shorted or disconnected 4. Green Led is Blinking with two consecutive fast blinks - the loop failed in the past and now is working correctly. 5. Red Led is Blinking at the start of a vehicle detection - the Filter function is ON 6. Red Led is Blinking at the end of a vehicle detection - the Extend function is ON 7. Red Led is Blinking during a vehicle detection - 4 minute limited presence time has expired. Front Controls Reset Frequency Counter Frequency Back Controls This toggle switch when pushed momentarily down will reset the detector This toggle switch when pushed momentarily up will count the frequency on the loop. This count is displayed by the Red Led blinks, each blink represents frequency of 10K Hz. Count between 3 to 13 blinks confirms that the loop detector is tuned to the loop. This toggle switch controls the loop frequency. Set different frequencies on adjacent loops. Verify frequencies with the frequency counter by counting the Red LED blinks. Sensitivity This rotary switch controls the detector sensitivity. During normal operation the sensitivity level is set to 3 or 4. DIP Switch Functions DIP OFF ON 1 Pulse on Relay II Presence on Relay II 2 Pulse on detect Pulse on Un-detect 3 Constant presence 4 minute limited presence time 4 "Fail Secure" "Fail Safe" 5 Filter Off Filter On 6 ASB Off Automatic Sensitivity Boost On 7 Extend detect 6 seconds 8 Extend detect 3 seconds (When Dip7 and 8 are in ON position the extend time is 9 seconds.) Warning: Do not use limited presence setting and / or "Fail Secure" setting for reversing gates, doors or barriers.

DIP - Detector Functions 1. Presence function is provided always by the presence relay output on pins 5, 6, and 10. These outputs are active when the detector detects a car. If there is a need for an additional presence output the Relay 2 can be configured as a second presence output by setting DIP 1 to ON position. 2. Pulse function is provided by the Relay 2 output on pins 3, 9, and 11. To obtain pulse on Relay 2 set DIP 1 to OFF position. The pulse of about 0.5 second can be generated when the car enters the loop or when it exits. To generate pulse on vehicle entry to the loop set DIP 2 to OFF position. To generate pulse on vehicle exit from the loop set DIP 2 to ON position. 3. The presence relay provides constant output as long as the car is detected on the loop. To obtain constant presence time set DIP 3 to OFF position. In some applications limited presence time is required. To obtain limited presence time of approximately 4 minutes set DIP 3 to ON position. Be aware that the detector relay will be released after 4 minutes even if the vehicle is still detected by the detector. This may by a serious hazard in applications where gates, doors or barriers are reversed, therefore never use this option in these applications. 4. When DIP 4 is set to ON position the detector works in "Fail Safe" mode of operation the detector will issue a detect signal when a car is detected, loop is disconnected or shorted, or when the power to the detector is interrupted. It is strongly recommended to use the detector in this mode. In some application there is a need to ignore the loop or power failures and only to provide the detect signal when a car is detected on the loop. To ignore loop or power failures set the detector to "Fail Secure" by setting DIP 4 to OFF position. Do not use this setting for application where gates, doors or barriers have to be reversed. Note: Functions on pins 6 and 10 are reversed if DIP 4 is set to OFF 5. In some applications it is necessary to filter out short detections such as cross traffic or short burst of radio frequency such as keying of a CB transmitter. To ignore these short detections set DIP 5 to ON position. This will cause any detection that is shorter than 2 seconds to be ignored. 6. To increase detection height when detecting high bed vehicles set DIP 6 to ON position. This setting will cause the sensitivity to automatically increase once the front axle of the truck is detected. The sensitivity will go back to the normal level once the truck left the loop. 7. To extend the presence output for 6 seconds after the vehicle left the loop set DIP 7 to ON position. 8. To extend the presence output for 3 seconds after the vehicle left the loop set DIP 8 to ON position. Note: If DIP 7 and DIP 8 are set to ON position the presence output will be extended 9 seconds after the vehicle left the loop.

Trouble Shooting Symptom Green indicator is not ON Possible Cause No input voltage Correction 1. Check voltage on pins 1 and 2. 2. Replace internal fuse 3. Check wiring to detector Green indicator flashes Green indicator flashes with two consecutive fast blinks Detector stays in detect mode after the car left the loop and fails to undetect. Detector detects intermittently even when there is no car on the loop. Loop wire shorted or disconnected Loop wire was temporarily shorted or disconnected 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 4. Cross-talk between adjacent loop detectors 1. Check loop resistance on pins 7 and 8 it should be less than 5 ohms and more than 0.5 ohms. 1. Check loop resistance on pins 7 and 8 while driving over the loop it should be less than 5 ohms and more than 0.5 ohms. The reading should be steady. 1. Perform megger test between loop lead and ground the reading should be larger than 100 megaohms. 2. Check that loop is tightly connected to proper terminals 3. Check that splices are tightly soldered and sealed against moisture. 1. Perform megger test between loop lead and ground the reading should be larger than 100 megaohms. 2. Check that loop is tightly connected to proper terminals 3. Check that splices are tightly soldered and sealed against moisture. 4. Set adjacent loops on different frequencies.

Place Address Label Here