EZ Plate Instantaneous

Similar documents
Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

INSTALLATION & MAINTENANCE MANUAL EZ PLATE INSTANTANEOUS WATER HEATER

ENGINEERED DUPLEX ALLOY

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

DigiTemp. Digital Water Tempering System. PVI.com

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Semi-Instantaneous Indirect Fired Water Heater

Heat Transfer Packages

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

Packaged Semi-Instantaneous Steam Fired Water Heater

AM SERIES BOILER INSTALLATION FORM

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

MODULEX BOILER INSTALLATION FORM

High Capacity Instantaneous Steam Fired Water Heater

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Originators of the Flexible Water Tube design

Domestic Hot Water Heaters and Boilers FTIIIC-6

Originators of the Flexible Water Tube design

INSTALLATION & MAINTENANCE MANUAL CSXT INSTANTANEOUS STEAM WATER HEATER Copyright 2006 PVI Industries, LLC

ADMS. AERCO Digital Mixing Station. AERCO.com

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

T. +44 (0) E.

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

Commercial Semi-Instantaneous Water Heaters

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

SmartPlate. Water Heaters. AERCO.com

SEQUENCE OF OPERATIONS

T. +44 (0) E.

Originators of the Flexible Water Tube design

ModuSat TP. Energy. Heat Interface Units

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

CONTROLLED CHILLED BEAM PUMP MODULE

heat interface units A BOILER WITHOUT A FLAME

Hydronic Product & Application Catalog

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

BENCHMARK BOILER INSTALLATION FORM

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

ModuSat TP. Energy. Heat Interface Units

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

June Copyright Climatec

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

TECHNICAL. Series 18. Pump Packages

Proudly assembled in U.S.A

Water Heaters. Solar Applications

Packaged Steam Fired Water Heater

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

INSTALLATION & MAINTENANCE MANUAL COBREX STORAGE WATER HEATER Steam Energy Source Models ( )(-2)(L)(150-***)A-TCX

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

ASME Packaged Indirect Fired Water Heater

.2 Section Waste Management and Disposal.

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

DIVISION FINNED WATER-TUBE BOILERS

Flo-Rite-Temp Instantaneous Steam/Water Heater

Flo-Rite-Temp Instantaneous Steam/Water Heater

BOILER APPLICATION GUIDE for:

Aldrich Blowdown Separators & Cooling Manifolds

HIGH EFFICIENCY COMMERCIAL BOILERS

AM Rapid Recovery Water Heaters

Tankless On Demand Electric Water Heater

Proudly assembled in U.S.A

FXLF-4. High Efficiency Water Heaters and Boilers

CONTROLLED CHILLED BEAM PUMP MODULE

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Submitted to Reference Approval Construction Unit Designation Schedule #

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

BuildingName The Description of the Project P DOCUMENTS

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Best Practices for Condensing Boilers

Submitted to Reference Approval Construction Unit Designation Schedule #

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

TRIDENT GS SERIES Central Chiller

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

University of Delaware

Transcription:

EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com

Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted instantaneous water heater that uses high or low temperature boiler water as the energy source. The heat exchanger is double-wall, brazed plate and temperature control is provided entirely on the domestic water side through a thermostatic mixing valve. This valve modulates infinitely in response to hot water demand. Ideal for Condensing Boiler Systems EZ Plate Instantaneous can work with all types of boilers, but is especially suited for condensing boilers where low return temperatures are beneficial to the operating efficiency of the system. Inside the plate exchanger, counter-flows of boiler and domestic water maximize the temperature differentials and allow the temperatures of the opposing liquids to cross with boiler return water becoming cooler than domestic outlet water. Due to their unique heat transfer characteristics, plate-type heat exchangers excel when applied in low-temperature boiler water loops. A plate-type exchanger, when supplied with 145 F boiler water, can produce 140 F domestic hot water while reducing boiler water return temperature to 110 F or lower. This is highly beneficial in condensing boiler systems where efficiency improves with reductions in both supply and return water temperatures. By comparison, u-tube heat exchangers are typically sized for a 20 F difference between the entering boiler water temperature and the desired domestic hot water outlet temperature. At-a-Glance Up to 6,000,000 Btuh output from 12 ft 2 of floor space Units are available to produce 10, 15 20, 30, 40, 50, 60, 75, 90 and 105 gpm of water with domestic outlet temperatures of 120, 140 or 160 F Designed to operate with lower boiler water supply and return temperatures to optimize condensing boiler operation Brazed plate heat exchangers Skid-mounted with factory pre-assembled piping Electronic communication with BAS optional 2

How It Works Domestic-Side Temperature Control No Boiler Water Valve Needed Demand for hot water causes cold water to flow into the water heater. The cold water can take either of two paths; through the cold port of the thermostatic temperature control valve or through the plate heat exchanger. Cold water entering the exchanger is heated to within 5 F of the boiler water temperature on the opposite side. Hot water exiting the heat exchanger enters the hot port of the control valve. The valve is self-contained with the ability to infinitely modulate the flows of cold and hot water as required to maintain the outlet temperature. The temperature setting on the valve is determined by the temperature sensing thermostatic element inside the valve. Under all flow conditions, the domestic outlet water is controlled to within 4 F of the valve set point. Outlet temperature is constantly monitored by a high-limit thermostat. In the event of an over-temperature condition, a solenoid valve will shut off the flow of water to the valve s hot port allowing water to flow only through the cold port of the valve. No boiler water valve is necessary to control domestic hot water temperature. The optional boiler water control valve restricts the boiler water, when demand is low. This can reduces the amount of boiler water passing through the heat exchanger. Boiler Water Inlet 145 F Domestic Water Outlet 140 F Domestic Water Inlet 40 F Boiler Water Outlet 100 F 3

Configurations Standard Configuration Boiler Water Supply Connection Plate-type Heat Exchanger Boiler Water Return Connection Steel Skid Pressure Relief Valve Clean-in-Place Fitting High-temperature Limit Solenoid Shutoff Valve Hot Water Outlet Thermostatic Temperature Control Valve Y-strainer with Blowdown Cold Water Inlet Optional Configuration with Modulating Boiler Water Control Valve Electronic Control Boiler Water Control Valve 4

Convenient Package With Low Cost Domestic Side Piping EZ Plate water heaters are completely factory piped and include all components shown in solid lines; including the hot and cold isolation valves. The heater only needs to be connected to domestic water lines and a building return circulation line with a minimum of 4 gpm flow. If a building circulator is not available, a small pump can be installed between the hot outlet piping and the cold inlet. Hot Outlet Building Return Cold Inlet Boiler Side Piping - Standard Product The standard EZ Plate configuration is intended to be installed with constant boiler water flow through the heat exchanger provided by the pressure drop between the supply and return headers or, if needed a zone pump. Even with VFD controlled boiler pumps, constant flow at the water heater is logical due to the year-round demand for domestic hot water and the requirement for a boiler loop flow path to establish a minimum run rate on the building circulator. This water heater also represents the lowest possible equipment cost. BOILER SUPPLY BOILER RETURN T P T P Boiler Side Piping - Modulating Boiler Water Valve When variable flow at the water heater is desired due to the operation of a VFD controlled boiler loop circulator, the EZ Plate can be configured with a modulalting boiler water valve. In this configuration, blended domestic return water to the water heater is monitored in a feed-forward control method to position the boiler water valve. The valve does not actually control the domestic hot outlet temperature but only modulates boiler water into the heat exchanger as required. Domestic hot water temperature is still controlled by the thermostatic valve. BOILER SUPPLY BOILER RETURN T P T P 123 Note: The piping illustrations are generalized. When applying low-water-volume instantaneous water heaters such as EZ Plate, there are additional considerations for the boiler loop. Characteristics such as boiler loop water volume, the number and type of boilers and the energy requirements of the domestic water system relative to the total boiler system BTU output must be taken into consideration. Contact with your PVI representative for design assistance. 5

Features Heat Exchanger ASME Section VIII, Div. 1 stamped for MAWP Brazed-plate heat exchanger double-wall Domestic Piping and Controls Fully assembled copper, brass and bronze waterside piping Infinitely modulating, self-contained, thermostatic temperature control valve; standard outlet temperatures include 120 F, 140 F, and 160 F ASME pressure relief valve Over-temperature solenoid shutoff valve Immersion temperature limiting device Clean-in-place valves for heat exchanger Bronze y-strainer with blow down valve Factory ready for connection to the building s domestic water re-circulation piping Heavy-duty painted steel skid Hot outlet temperature gauge Isolation valves 18-month heat exchanger warranty Optional Features and Equipment Field Installed Optional Equipment Water pressure gauge Inlet water temperature gauge Factory Installed Optional Equipment 2-way modulating boiler water control valve with fast-acting magnetic solenoid actuator (includes electronic control with LED temperature readouts and communication port) Boiler water temperature and pressure gauge on the inlet and outlet Y-strainer with blow down valve on boiler water inlet Electronic temperature monitor with LED readout (Modbus serial connection) Protocol gateway for Modbus TCP/IP, BacNet IP or BacNet MSTP A S M E U 6

Specifications and Dimensions Boiler Water Side Domestic Water Side Model Boiler Water Supply 150ºF 40ºF to 140ºF Boiler Water Flow (gpm) Boiler Water Pressure Drop Recovery (gpm) Hourly BTU Output Domestic Water Pressure Drop EZ-10-DW 10 0.9 5.9 295,000 1.1 EZ-15-DW 15 0.8 8.9 450,000 1.9 EZ-20-DW 20 0.8 11.9 600,000 2 EZ-30-DW 30 1.1 16.9 850,000 1.4 EZ-40-DW 40 1.0 22.7 1,125,000 1.2 EZ-50-DW 50 1.2 27.6 1,375,000 1.6 EZ-60-DW 60 1.4 32.6 1,625,000 2.1 EZ-75-DW 75 1.4 40.3 2,000,000 2.5 EZ-90-DW 90 1.5 48.4 2,450,000 3.3 EZ-105-DW 105 1.4 57.5 2,875,000 4 Boiler Water Side Domestic Water Side Model Boiler Water Supply 180ºF 40ºF to 140ºF Boiler Water Flow (gpm) Boiler Water Pressure Drop Recovery (gpm) Hourly BTU Output Domestic Water Pressure Drop EZ-10-DW 10 0.9 10 500,000 3 EZ-15-DW 15 0.8 15.5 775,000 5.75 EZ-20-DW 20 0.8 21 1,050,000 6 EZ-30-DW 30 1.1 30.3 1,500,000 4.3 EZ-40-DW 40 1.0 40.8 2,000,000 3.5 EZ-50-DW 50 1.2 50.2 2,500,000 5 EZ-60-DW 60 1.4 58.9 3,000,000 6.2 EZ-75-DW 75 1.4 74.3 3,750,000 7.8 EZ-90-DW 90 1.5 88.2 4,500,000 11.6 EZ-105-DW 105 1.4 97.5 4,875,000 11 7

Manufacturing ASME Commercial Water Heaters Since 1961 PVI Industries 3209 Galvez Avenue Fort Worth, TX 76111 T: (817) 335-9531 Toll Free: (800) 784-8326 PVI.com PV 8528 2-2018 2018 PVI