Integrity Bath. Installation Manual. Important Safety Instructions Read & Follow All Instructions Thoroughly

Similar documents
Integrity Bath. Operating Instructions and Training Checklist. Important Safety Instructions Read & Follow All Instructions Thoroughly

Gen II Entree Bath - All Models

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly

1-866-PENNERS

Advantage Series Bathing System Specifications

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Superior Spa with Aqua-Aire

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

INSTALLATION GUIDE Dual Fuel Ranges

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

Undercounter Refrigeration

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Multi-Function Cooktop

Installation Instructions

Installation Instructions

SS1095 Ice Maker.

L A signature series TA T N E RE O, A L L A T S IN

Installation Manual PS-225 & PS-275

Destination Collection Whirlpool Bath Installation Instructions

557X-558X Comfort Care & Cozy Comfort, Premier Recliner 567X-5680 XL Cozy Comfort & XL Cozy Comfort Swing-Arm, Premier Recliner

PRO SERIES IMPORTANT SAFETY INFORMATION

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Installation Manual PS-200 & PS-201

COPPER FREESTANDING TUB

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Installation S

BEFORE OPERATING THE MACHINE: WARNING

Dishwasher Installation Instructions DW 24XT/DW 24XV

Installation & Operating Guide

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC


INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Installation Instructions Built-In Dishwasher

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

Installation S

Installation Instructions

Installation S

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation Instructions

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Top Control Dishwasher

Food Waste Disposer Instruction Manual

Installation and Operation Manual MG-304. Please read this manual carefully before use.

TIMES SQUARE TWO-HANDLE THERMOSTAT

GULFSTREAM PLASTICS LTD.

Medical Equipment Washer Information & Setup

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

PRO 2000i LOW LEVEL DEPOSITOR

Installation Instructions Built-In Dishwasher

INSTALLATION INSTRUCTIONS

Installation S

Installation Instructions

Installation Instructions

Installation. Please keep this manual for future reference.

ENVIRO-PAK. Operation and Maintenance Manual. Manufacturer of

Features Luxier SP21-SS

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

Artizan Ortho-Pedo Bench Installation / User Manual

Installation Instructions

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Installation Instructions

Pump Out Vacuums Polyethylene & Steel

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

Installation Instructions

Technical Specifications Section 1

RESIN FREESTANDING TUB

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation Instructions Wall Ovens

INSTALLATION & OPERATING INSTRUCTIONS

Assembly instructions. Alexandria Pedicare System ALEXANDRIA. Perfect design. Personal service.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Installation Guide BUBBLEMASSAGE. English page T01-A

Installation Instructions Dual Fuel Ranges

3/4 HP Model Trimmer Operating Instructions

SAVE THESE INSTRUCTIONS

Installation Instructions

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

INSTALLTION FOR THERMOSTATIC VALVES

INSTALLATION INSTRUCTIONS

Transcription:

Integrity Bath Model MB-80-R Installation Manual (Specifications & Rough-In Included) Important Safety Instructions Read & Follow All Instructions Thoroughly 2071 14 th Ave Columbus, NE 68601 800-798-5867 FAX: 402-563-9102 www.mastercarebath.com Form MB80MN11 Rev 0001-07-27-2015

Note: Integrity Bath must be purchased or specified with the Integrity Transfer Chair. For more information please contact MasterCare. MasterCare Patient Equipment Integrity Bath Standard Tub Models MB-80 Console Tub Models MB-80-R Dimensions: Bath: Width: Standard (MB-80) 34 ½ Width: Console (MB-80-R) 52 ½ Length: Standard (MB-80) 70 Length: Tub/Console (MB-80-R) 79 Tub Rim Height: (All Models) 36 ½ Console Height: Console (MB-80-R) 68 Specifications: Back Flow Prevention: 1 Air gap for tub fill, vacuum breakers for MB-80-R shower hoses. Watts N-9 double checks for MB-80 shower hoses. Note: The factory provided backflow prevention is the most widely accepted. Local codes may require changes, which is the responsibility of the local plumbing contractor. BathAire (SM) Outlets: 5 with 6 ports each for a total 30 warm air massage outlets. Door Seal: Seal certified by Warnock Hersey to the ASME A112.19.15-2005 and ASTM D 2000 standards to insure long lasting durability for bathtubs with pressure sealed doors. Highly resistant to oils, detergents and all water conditions. Electrical: UL/CSA approved 120V AC, 60 Hz, 15 Amp dead front GFCI (ground fault circuit interrupter) Installation Time: 1 ½ hours Inspection and Adjustments: ½ hour Liquids Storage: Located behind lockable service access doors. Motor Specs: BathAire (SM) Motor: 120 V., 11 Amps, 1.3 H.P. Variable speed with built-in 600 watt heating element for maximum comfort and control. Patent: US 6,766,543 B1. Room Size: Standard Model 6 wide x 9 4 long; Console model 6 wide x 10 long. Can fit in smaller room; call with dimensions. Service Access: Controlled access through lockable service doors. Electrical Standards: CAN/CSA C22.2 No. 218.2-93 (R2004) Hydromassage Bathtub Appliances. UL 1795 Hydromassage Bathtubs, Third Edition, Including revisions through to Sept. 22, 2006. Plumbing Standards: Warnock Hersey, CSA B45.5 (2008); ASME A112.19.15 (2005); CSA B45S1 (2004); ANSI Z124.1.2 (2005). State Standards: IL Dept. of Public Health, Product approval letter dated 10/28/04. Commonwealth of Massachusetts, Approval Code P3-1108-235 Michigan State Code Commission, Certificate of Acceptability No. 1554 PA. Wisconsin Administrative Code, In Compliance with chapters Comm. 82 through 84, Wis. Adm. Code, and Chapters 145-160, Wisconsin Statutes. Product File #20060062 & 20010143. Establishment Registration: 30033336913 Switches: Membrane Thermometer: Analog or digital temperature measurements. Tub Entry: Door counter-balanced with simple guidance system for ease of operation. Tub Fill/Shower: Built-in thermostatic mixing valve certified to ASSE 1016-2005, AMSE A112.18.1-2005, CSA B125, and UPC listed. Tub Fill / Shower shut off valves certified ASSE and UPC listed with ceramic disc controls. Tub Shell: Sanitary gel-coated FRP (Fiberglass Reinforced Polymer). Tub Water Use: 55 gallons Minimum with normal displacement 4 inches below over flow escutcheon. Waste: 2" PVC schedule 40 pipe. Water Connection: ¾ hose swivel connections supplied by manufacturer Water Supply: ¾ hot and cold with shut-offs. Hot and cold water pressure 45 psi. Hot water temperature to be 120 o F and Cold water to be 59 o F. Weight: Useful Life: Reservoir: MB-80 (420 lbs), MB-80-R (Tub 385 lbs, Console 240 lbs), MT-80 Transfer system (150 lbs). Approximately 10 years--determined by use and conditions 45 gallon fill capacity Warning: 1) Risk of electrical shock; Disconnect electric power source before installation and subsequent servicing. 2) An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electrical shock, this terminal must be connected to the grounding means provided in the electric supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment. 3) Install this unit in accordance with the U.S. National Electrical Code in the U.S.A and the Canadian Electrical Code, Part I in Canada. 2071 14th Ave. Columbus, NE 68601 Ph: 800-798-5867 Fax: 402-564-9102 Web: mastercarebath.com Page 2 of 16

1. Plan Bathing System Layout Floor Surface: Correct & Incorrect FIG. # 1 Right Hinged Door FIG: # 3 CONSOLE 112 " 130 " 45" 31" 51" CABINET TUB CHAIR TRANSFER SYSTEM CORRECT FLOOR DRAIN LOCATION 1O4" 85 3/4" Room Door 40 3/4 Inside line s represent the minimum area for in stallation with room door positioned as shown to open outward. See plumb ing notes next page regarding floor drain. FIG. # 4 CORRECT FLOOR SURFACE Outside lines represent the recommended area for optimum operational access. FIG. # 2 Left Hinged Door 130 " 112 " INCORRECT INCLINED FLOOR SURFACE 1O4" 85 3/4 40 3/4" Inside line s represent the minimum area for in stallation with room door positioned as shown to open outward. 51" Room Door Warning: INCORRECT DRAIN LOCATION IN FRONT OF TUB 45" CAUTION: Outside lines represent the recommended area for optimum operational access. See plumbing notes next page regarding floor drain. Choose flattest floor location. Make sure sufficient room is provided to allow unobstructed area for transfer in and out of the tub with the transfer system. Room dimensions, door sizes and floor drain placement, must comply with all applicable building and health codes. Caution: Figure #1 and #2 tub placement is critical for door opening and access to disinfectant and dispensing both sides. Space around system is needed to allow assistant to access resident, disinfectant & dispensing systems and maintain both sides. Avoid covering switches, valves and other items that must be accessed by authorized personnel or maintenance. Page 3 of 16

2. Mark Tub Center Line On Wall & Floor FIG. # 1 Center Line Of Tub Bathing System Footprint 52 1/2" 26" 33 1/2" 76 1/2" 33" Allow Minimum 33" For Door Arc 3. Install Electrical Service 120V AC, 60 Hz, 15 Amp CLASS A GFCI receptacle flush mounted in wall WARNING: Connect the bathing system ONLY to a circuit protected by a CLASS A GFCI FIG. # 2 Wall 10 25 Center Line Of Tub 4. Install Plumbing Service FIG. # 3 18" 5" Wall 5" Facets or ball valves with 3/4" hose connectors 3" +/- 1/4 " "2" PVC Waste Pipe Floor Floor NOTE: Item 4-Install Plumbing Service The height of the PVC waste pipe should be 3" All dimensions are approximate + / - 1/4" FIG. # 4 Floor 3" +/- 1/4" Alternate # 1 Alternate # 2 Wall Wall Approx. 27 " To Tub Drain 2" Waste Pipe With Trap Electrical Service Notes Floor 3" +/- 1/4" Approx. 27 " To Tub Drain 2" Waste Pipe With Trap WARNING: Electrical current can cause severe injury or death if the following precautions are not heeded. WARNING: Turn off power source. WARNING: Lock circuit open to prevent accidental activation. WARNING: Electrical service must be located higher than plumbing service. WARNING: Electrical switches and outlets must not be in reach by bathers in the tub. WARNING: Electrical wiring must comply with all applicable codes. A licensed electrician may be required to install the service. WARNING: Connect the bathing system ONLY to a circuit protected by a CLASS A GFCI. WARNING: Connect only to a branch circuit protected by an over current protection device rated not more than 15 amps. Plumbing Service Notes It is strongly recommended that a floor drain be installed in the vicinity of the front of the tub 40 either side of the centerline of the tub. Plumbing service must comply with all applicable building and plumbing codes. A licensed plumber may be required to install this service. Local plumbing codes may require back flow prevents to be installed on both the hot and cold water lines. CAUTION: The tub uses flexible hoses--it is an industry standard and is recommended by MasterCare to replace the hoses every five (5) years and to inspect the hoses yearly for any obvious signs of damage, wear, etc. If any signs of damage or wear are noted replace the hoses. General Notes Caution: Wall and floor openings for the electrical and plumbing service installations should be closed and sealed to help maintain sanitary conditions. Memo: P Trap to be supplied by customer not manufacturer. Page 4 of 16

BATHING SYSTEM INSTALLATION General Warnings: Warning: Risk of electrical shock. All equipment comes standard with a 120V 3 prong electrical plug. Plug the bathing system into a 120V AC, 60 Hz, 15 Amp CLASS A GFCI receptacle. All hard wiring must be performed by a licensed electrician following local codes. The main power supply must be disconnected before hard wiring. Warning!! Failure to disconnect main power before hard wiring unit can result in Electrical Shock, Death or Damage to Equipment not covered with the warranty. An equipment grounding terminal is provided in the field wiring compartment (electrical box on the unit). To reduce the risk of electrical shock, this terminal must be connected to the grounding means provided in the electrical supply panel with a conductor equivalent in size to circuit conductors supplying this equipment. Install this unit in accordance with the Canadian electrical code, part I, in Canada and in accordance with the U.S. national electrical code in the U.S.A. or local codes whichever applies. Warning: Risk of Scalding. 1. Check Electrical and Plumbing and Service Rough-Ins Bathing system location identified and marked per instructions in rough-ins Plumbing installed according to instructions in roughin manual. Wall and floor openings around pipes closed and sealed. 2. Clear Waste Water Drain Make sure wastewater drain is free of debris 3. Flush Debris from Hot and Cold Water Service Lines Flush debris from the incoming hot and cold water lines. Run about 10 gallons through each line into a bucket. This will protect the plumbing valves in the bathing system from potential damage by migration of debris into its vital components. You are now ready to install your MasterCare Integrity Bathing System. 4. Position Tub Hot water can scald people. Temperature control valve must be adjusted before using bath. Do not allow temperature to exceed 109.4 F (43 C) Other Precautions: FIG. # 1 9 Anchor bolt hole location. Tub and cabinet components are heavy and bulky. Do not attempt to lift or move this tub or cabinet alone. Damp or wet floors can be slippery causing falls and serious injury. Dry wet areas before starting to install bathing system. Standing in tub can damage the tub or lead to falls and serious injury. Do not stand in tub during installation or use. Do not allow residents to stand in the tub. CAUTION: The tub uses flexible hoses--it is an industry standard and is recommended by MasterCare to replace the hoses every five (5) years and to inspect the hoses yearly for any obvious signs of damage, wear, etc. If any signs of damage or wear are noted replace the hoses. 2" (5 cm) Connector Slide back of tub towards the wall so that top edge is squared off 9 (23.9cm) from wall. Remove dispensing and disinfectant boxes by removing the 2 screws at the top of the boxes then lift and set them to the side of the door opening. Make sure 2 drain on tub is aligned with 2 drain rough-in. Connect with 2 flexible connector, don t tighten yet. Note: If flexible connector doesn t meet local codes use any type of detachable coupler that meets code to allow drain connection to be uncoupled so tub can slid forward for service. Page 5 of 16

5. Locate & Set Anchors In Floor Find the two 1/4 holes located in the fiberglass rear floor area of the tub. Mark the hole locations on the floor, disconnect the 2 drain and slide the tub forward about six feet. Drill two 1/2 holes for the 1/4 SS anchor bolt anchors. Clean/blow out the holes that were previously drilled. Slide the tub back, connect the drain and set the anchors accordingly. Caution: During next step be careful not to scratch top or sides of tub while sliding tub inside the cabinet. 6. Pre-Position Reservoir Position the Reservoir (see figure #1) centered on the two inch drain. Leave about 40 between the reservoir support cabinets and wall for access purposes. Connect hot/ cold water high pressure hoses from inside of the support cabinets to the hot and cold water supply valves with ¾ male hose fittings. Warning: FIG. # 2 Shim to level If shimming to level tub is necessary because of unlevel floor, use non-porous material such as floor tile. If shimming ¾ high or more contact MasterCare representative for riser kit to increase the height of carrier for positive tub/chair latch connection. Transfer chair could drop to floor if tub and carrier rails are not correctly aligned. Tub must be level to facilitate alignment of lower carrier rails to tub rails. 9. Make Final Connections FIG. # 1 7. Reset Tub 40 Connect the 2 tub drain to 2 drain rough-in. Replace the dispensing boxes on both sides. Plug the bathing system into a 120V AC, 60 Hz, 15 Amp CLASS A GFCI receptacle. Connect the remaining hot water supply hose to the ¾ upper male hose fitting at the inside top of the disinfectant supply cabinet. 10. Tighten Anchor Bolts Re-install dispensing boxes 11. Position Reservoir Against Wall Slide tub back inside of reservoir side service cabinets to 9 square with the wall. Then remove the disinfectant and oil/shampoo dispensing boxes and set aside. Align predrilled anchor holes in rear floor of tub with anchors already set in the floor. Secure with anchor bolts. 8. Level Tub Shim with floor tile as needed to level tub (see FIG. # 2 this page). Remove any obstructions that would interfere with the fit of the console against the wall. If needed trim the back edge of the lower reservoir supports on each side to fit around the mop board or cut the mop board to butt against them. Carefully slide reservoir over tub all the way back so that it is firmly against the wall. The trim seal bulb on the back edge should be slightly compressed. 12. Connect Disinfectant Shower Wand Hose Connect ½ female end of the disinfectant hose to the ½ lower male fitting on the inside top of the disinfectant box. Page 6 of 16

VERIFY SYSTEM OPERATION 13. Close and Lock Door Reference the copy of wall chart instructions, page 14, as needed during the verification process. Rotate and position door inside the tub as far as it will go. Wide both hands push door down carefully until it latches in the down position. Rotate door cam arm up into full locked position. 14. Turn on BathAire Turn on BathAire by pushing the BathAire On/Off button. 15. Turn on Supply Water Turn on the hot and cold water supply valves. With the shower wand pointed inside the tub turn the chrome shower spray on/off handle counter clockwise (on) purge the plumbing system of any trapped air. Turn off after trapped air is purged. Rotate the reservoir open/closed handle on side of the console to open position. Rotate chrome reservoir fill knob on plumbing control deck counter clockwise until full open. 16. Check for Connector Leaks Check all hose connections for leaks. While holding shower wand over inside of tub turn chrome shower spray handle counter clockwise (on) and check for leaks. Turn shower spray off. While holding disinfectant wand over inside of tub turn chrome disinfectant handle counter clockwise (on) and check for leaks. Turn disinfectant handle clockwise (off). Tighten any loose connections that are leaking. 17. Check Fill Temp Gauge Adjust temperature of the incoming water to approximately 102 F (39 C) by turning the mixing valve handle to a position that provides a constant readout of desired temperature on the Thermometer located on the right side of the reservoir. Then turn the mixing valve handle to full hot. 18. Fill Reservoir Rotate the reservoir open/closed handle on side of the console to closed position. Continue to fill reservoir until completely full. A built-in float valve will automatically shut off the water when the reservoir is full. Check bath temp gauge, it should read approximately (within 3 degrees) what the fill temp. gauge read while filling the reservoir. 19. Check Reservoir Open/Close Function Rotate reservoir open/close handle on the side of the console to the open position. Then rotate reservoir open/close handle on the side of the console to the closed position. Water flow from fill spigot should stop after a few seconds with some minor residual flow until all the water drains out of the plumbing system. 20. Fill Tub Rotate reservoir open/close handle on the side of the console back to the open position. Water should flow freely from the reservoir into the tub. Fill time from reservoir to tub should be approximately 1 minute and 45 seconds under optimum conditions. Memo: Without a bather inside the tub to displace water the tub will only be partially filled. 21. Check BathAire Hydromassage Function Air bubbles should flow evenly out of all aerators. The level of air flow was preset at the factory. Check all functions on the oval BathAire control panel per copy of the operational procedures wall chart on page 14 of this manual.. 22. Drain Tub Rotate Drain Open/Close lever to open position. Allow tub to drain completely. Check all drain connections for leaks. Make sure all water drains from tub. If not, tub is not level. Level per instructions on page 7. Warning: Hot water can scald people. Temperature of the water in the tub must not exceed 109.4 F (43 C) or limit per facility policy whichever is less. If it does, call MasterCare s Technical Service Department 1-800-798-5867 for assistance. Page 7 of 16

23. Check & Adjust Disinfectant Dispensing System Refer to the Operational Procedures (In the black binder sent with the tub) for the disinfectant dispensing system to set up and check this system to make sure it operates as intended. With disinfectant wand pointed inside the tub turn chrome disinfectant On/Off handle counter clockwise all the way on. The clear tubing line from the one gallon bottle of concentrated cleaner disinfectant should have solution all the way up. After a few seconds a soapy disinfectant solution will emit from the wand. See below for adjustments. Caution: The Cleaner/Disinfectant system is preset at the factory to dispense 2 oz. of concentrated disinfectant per gallon of water. Using other brand disinfectant cleaners or system replacement parts could cause this recommended ratio to change and result in an incorrect solution. 24. Check & Program Bath Oil & Shampoo Dispensing System Remove the service access door on the right side of the tub. Connect the one gallon jugs of bath oil and shampoo shipped separately in the Starter Kit to the appropriate dispensing hoses. Bath oil left hose and Shampoo right hose. To prime, push the appropriate button for the solution you want to prime for seven seconds. Refer to the Operational Procedures (In the black binder sent with the tub) for the Bath Oil & Shampoo dispensing system to set up and check the system to make sure it operates as intended. Set to dispense ½ oz. bath oil and ¼ oz shampoo. If any problems are encountered in items 23 or 24 above, check the Maintenance Instructions included in the aforementioned Operating Instructions or call your local MasterCare Representative or MasterCare direct for technical service support. The flow rate of concentrate can be adjusted by turning the adjustment screw (see figure #1) on the injector housing counter clockwise for more, clockwise for less. The adjustment screw can be accessed through the small plugged hole to the left of the disinfectant On/Off handle. FIG. # 1 Page 8 of 16

CHAIR SYSTEM ADJUSTMENT General Warnings: 2. Position Transfer System FIG # 2 Tub & Chair rails must align properly to prevent chair derailment and provide smooth transfer of the chair. Transfer system lower carrier must latch to avoid disengagement from tub. Transfer system lower carrier caster bumpers, docking pin horizontal and vertical, rail mounting bar & bumpers and chair rails alignment must be checked and adjusted before use. Improper chair to tub transfer adjustment could allow residents to fall to the floor resulting in severe injury. Failure to heed these warnings could result in injury to the patient or operator. Tub Rails Carrier Rails Under Chair 1. Open Tub Door MEMO: For model MB-80-R with built-in chair without lower carrier disregard the rest of this procedure. Do, however, check the function of the chair lock lever. Pull up on the lever and move and lock the chair into its four basic positions: front for transfers, all the way back for upright bathing and about ¾ back for reclined bathing. See drawing of chair features on page 13. FIG # 1 Tub Door Page 9 of 16

3. Adjust Rear Caster Bumpers Adjust lower rear caster bumpers with two 9/16 wrenches as shown below: Caster Bumper 1/8" Gap Both Sides Fig # 1 Tub Pedestal 4. Adjust Carrier Docking Pin To Tub Docking Receiver (See Diagrams Below) CAUTION! Do not force docking pin into Receiver The docking pin was adjusted to properly engage the docking pin receiver at the factory. However because of uneven floor surfaces, minor adjustments may be needed, you might have to make adjustments to the docking pin device so that it properly aligns and engages the receiver and locks into place. Push transfer system gently towards the tub until the docking pin engages into the docking pin receiver and locks into place. If the docking pin does not properly engage the receiver and lock into place, carefully transfer the upper chair into the tub by pulling up on the active chair lock (See Figure # 2) and transfer the chair from the carrier rails onto the tub rails. Push the chair into the tub at least midway to continue with the docking pin adjustment. FIG # 2 1 Side c ut-a-way view of latch pin receiver with chair latch pin positioned prior to docking. Latch Pin Receiver Latch Pin 2 Side c ut-a-way view of latch pin receiver with chair latch pin in initial engagement phase. Active Chair Lock 3 Side c ut-a-way v iew of latch pin receiver with chair latch pin in fully engaged position. Access the alignment of the docking pin to the receiver then make the required adjustments for the docking pin to properly engage the receiver and lock into place. Check by pulling on the lower carrier to make sure it is locked into position. Page 10 of 16

4. (Continued) The diagram below of the docking pin device will help you determine which nuts to loosen to make the required adjustments. Make sure tub is level per item # 8 page # 7 before making these adjustments. If the docking pin is too high or too low loosen the up/down adjustment nuts and adjust as needed. Tighten the nuts back down securely. Assess the alignment of the docking pin to the receiver then make the required adjustments for the docking pin to properly engage the receiver and lock into place. FIG. # 1 TUB 6. Align Lower Carrier Rails to Tub Rails Position the lower carrier rails flush against the tub rails. Looking down from the top, the two lower carrier rails should align parallel with the tub rails. Looking from the side, the top of the two carrier rails should be 1/16 above the plain of the tub rails. See below: 17 7/16 Front Rail To Rail FIG. # 3 Top View Unit Without Scale Carrier Rail Rear Carrier Rails Width Dimension Must Match Tub Rails Width Tub Rail Carrier & Tub Rails Must Butt Against Each Other Docking Pin Receiver In/Out Adjustment Nuts Docking Pin Docking Pin Release Lever Up/Down & Side to Side Adjustment Nuts 5. Center Rail Mounting Bars In The Door Opening and Adjust Mounting Bar Bumpers 17 7/16 Front Rail To Rail Carrier Rail FIG. # 4 Top View Unit With Scale Carrier Rail Rear Carrier Rails Width Dimension 1/16 Wider Than Tub Rails Width Each Side Carrier Rail Tub Rail Tub Rail Carrier & Tub Rails Must Butt Against Each Other Tub Rail With the carrier correctly latched to the tub, verify the mounting bars under the lower carrier rails have equal space between the mounting bars and the sides of the door opening. If not, loosen the side to side adjustment nuts on the docking pin and adjust as needed. Verify all docking pin assembly nuts and bolts are tight. Carrier l Rail FIG. # 5 Side View 1/16" Tub Rail Lower Carrier Rail Bumper Mounting Bar 9/16" Nuts FIG. # 2 Docking Pin Release Lever Foot Ramp 9/16" Nuts Brake Unlock Tab To adjust, loosen the 9/16 nuts at the base of the lower carrier rails. See Figure # 2 on this page. Then make the required up/down and side to side adjustments to match the lower carrier rails to the tub rail. Tighten the nuts against each other when the desired adjustment is achieved. Page 11 of 16

7. Return Chair From Inside Tub to Lower Carrier Rails. Release chair from a locked position by pulling up on main chair release lever (See figure # 1 below). Holding the release lever up, roll the chair forward onto the lower carrier rails until it locks into position. Figure # 1 Transfer System 10. Clean & Rinse The Bathing System Before Using Before using this equipment: a) Remove all rough debris from inside the tub. b) Clean and rinse the system following the guidelines in the Operational Procedures Manual. 11. Operations Brake Lock Tab Front Locking Caster Brake Unlock Tab Carrier Arm Leg Rest Adjustment Latch Lower Carrier Chair Arm Chair Docking Pin Release Lever Main Chair Release Lever Lower Carrier Rail Passive Chair Lock Active Chair Lock Docking Pin Before using the system to bathe individuals the operator must be trained by a qualified trainer (an authorized MasterCare Representative or facility Inservice Trainer) in the proper use of this equipment according to the guidelines in the Operations Manual. For first time users of this equipment call your local MasterCare Representative or MasterCare Patient Equipment, Inc. to make arrangements for training 8. Release Transfer System From Tub Unlock the caster brakes by stepping down on the caster brake unlock tabs (Figure # 1 above). Release the lower carrier from its connection to the tub by stepping down on the docking pin release lever (Figure # 1 above) and pushing the transfer system away from the tub. 9. Final Check As a final check, using the above techniques, reconnect the transfer system to the tub. Transfer the chair back into the tub. Then back onto the lower carrier rails. These functions should be smooth and easy to achieve. If not make the re-adjustments as necessary to achieve the desired function. Page 12 of 16

OPERATING INSTRUCTIONS MasterCare Integrity Bath Model MB-80-R 1) Fill Reservoir: * Make sure the Tub Fill Lever is turned to a full closed position. Make sure the Shower Wand is directed into tub. Turn the Shower Control Valve on. Adjust Mixing Valve for desired safe water temperature (per facility policy) displayed on the bottom thermometer labeled Fill Temp. Turn Shower Control Valve off. Turn Reservoir Fill Valve on. Continue monitoring to maintain desired temperature. Reservoir fill will shut off automatically when full. 2) Transfer Resident Into Tub: * Push BathAire Control On/Off Button to turn on and adjust to desired speed using More & Less Air/Heat Buttons. * Open Tub Door. Back Chair towards tub to align Chair Rails with Tub Rails. * Push Chair back until Lower Carrier Latch Pin is engaged in the Receiver (located in the lower front center of the tub) and locks into position. Test by pulling on Chair/Carrier arms to make sure Lower Carrier is locked into position. Lock front Locking Casters by stepping down on Brake Lock. Adjust leg rest up one click by pulling up on leg rest. * Pull up on Active Chair Lock, push chair into tub. Release Locking Casters. Unlock Lower Carrier from tub by stepping down on the Latch Pin Release Lever, push out-of-way. If tub has built-in chair, lock into front position, verify it is locked by pushing on it, then transfer resident into chair. *Position door inside tub, push down until it latches and rotate Door Cam Arm up. BathAire Control 3) Before Filling The Tub From The Reservoir: 2 Speed On/Off Wave * Check bath temperature on the upper thermometer labeled Bath Temp. Make sure the desired water temperature per facility policy is achieved (See warning # 1). * If bath water exceeds desired temperatures, remove resident from bath per. step # 6. Close door and rotate Door Cam Arm up. Open drain. Drain sufficient water from console to adjust temp to desire level per instructions in step #1. More Air/Heat 4) Fill Tub: * After desired temp is verified, close drain and open Tub Fill Lever and leave open until desired water level is achieved. Then close and fill for next bath, or turn off Reservoir Fill Valve if no more baths are scheduled. 5) To Use Shower Wand: Follow procedure in step # 1 above. Test on wrist before showering resident. Less Air/Heat 6) To Remove Resident From Tub: Open drain. After water is drained, turn off BathAire and open door. Adjust Leg Rest one click up. Align lower carrier to tub and engage per step # 2 above, then lock the front casters. Pull up on Main Chair Release Lever, then roll resident onto Chair Rails. (See warning # 2 below) Unlock front casters. Step down on Latch Pin Release Lever to disengage carrier from tub to transfer resident. If tub has built-in chair, lock into front position and transfer resident out using proper ergonomic techniques. Disinfectant Wand Disinfectant Wand On/Off Valve Behind The Side Service Door Tub Rails Reservoir Shower Wand Tub Door Opened 7) To Clean/Sanitize Tub: Return chair to inside of tub. Close door and rotate Door Cam Arm up. Close drain. Rinse inside surfaces of tub & chair with shower wand. Apply MasterCare disinfectant cleaner with Disinfectant Wand to all chair parts, inside tub surfaces and removed pads. Scrub with brush. Follow directions on disinfectant cleaner label. Rinse with hot water. At the end of the day, shut off Reservoir Fill Valve and drain reservoir completely. Leave Tub Fill Lever in open position. Remove door seal, pads and belts for daily cleaning and sanitizing. Door Latch Release Button Door Seal Open/ Close Arm Latch Pin Receiver Auxiliary Drain Open/Close Lever Auxiliary Drain Open/Close Lever Mixing Valve Oil/Shampoo Control Panel Latch Pin Receiver Reservoir Fill On/Off Valve Shower On/Off Valve Drain Open/ Close Lever Bath Oil Shampoo Bath Water Temperature Fill Temperature Tub Fill Lever Key Latch Aroma Therapy Cap GFCI ReSet Service Access Door Brake Lock Tab Front Locking Castor Brake Unlock Tab Carrier Arm Leg Rest Adjustment Latch Lower Carrier Chair Arm Chair Latch Pin Release Lever Chair Rail Main Chair Release Lever Passive Chair Lock Active Chair Lock Latch Pin Page 13 of 16

BATH OIL SHAMPOO MasterCare MB-80-R Installation Manual (Specifications & Rough-In Included) for MasterCare Shower Cabinets & Integrity Bath Systems With Built-In Toilet Feature Rear View Of Integrity Tub 0r Shower Cabinet Rough-In 3/4 Hot Water Supply With MPT Shutoff Valve Rough-In 3/4 Cold Water Supply With MPT Shutoff Valve 17 ½ 16 3 1/4 3 1/4 5 1/4 Rough-In 1 (50-60 psi) Dedicated Separate Cold Water Supply With MPT Shutoff Valve Connect To 4 Wax Free Toilet Seal Already Attached With A Flange To The Toilet Outlet From A 4 Sewer Tap. See Memo. Also See Side View Below For More Detail. Connect To 2 Tub Drain Using The 2 Fernco Connector Suppled In The Factory Install Kit. See Side View Below For More Detail. Floor 3 ½ 16 3/4 Memo: 1) Local codes that require connection to a 4 sewer tap will be the responsibility of the purchasing entity. 2) For electrical rough-ins use the same guidelines in the standard Integrity Rough-In Manual which these special instructions were inserted in. 3) MasterCare s bathing and showering systems are certified as meeting all national plumbing and electrical codes. Local codes exceeding the requirements of the national codes are the responsibility of the purchasing entity. Cut-A-Way Side View of Tub & Toilet Drain Detail Integrity Tubs With (See Memo Below) & Without Reservoir 0r Shower Cabinet 11 1 ½ Center Line Of Tub/Shower Cabinet 9 MasterCare Wall MB-80 Wall MB-80-R Floor 1 ½ C/L Tub Drain From Floor 2 SCH 40 PVC Drain Pipe To P Trap Rough-In In Floor P Trap Supplied by Purchasing Entity. 4 SCH 40 PVC Drain Pipe From Toilet To Sewer Tap Rough-In. No Trap Needed. 3 ½ C/L Toilet Drain From Floor Memo: Above drawing shows the Integrity Tub Without Reservoir Model MB-80. The Integrity Tub With Reservoir (not shown) has the same exact tub & toilet drain specifications with the tub rear 9 from the wall. This allows you install rough-ins for connection to the tub and toilet drains within the 9 space between the rear of the tub and the wall. Page 14 of 16

MasterCare BathAire ThermAire BathAire ThermAire On/Off Wave MasterCare On/Off Wave MasterCare MB-80-R Right Hinged Door MB-80-R Left Hinged Door MB-80 Right Hinged Door MB-80 Left Hinged Door BathAire ThermAire BathAire ThermAire On/Off Wave MasterCare On/Off Wave MasterCare MB-80-R Integrity Bath To determine the hinged door location on the Integrity tub you are ordering, picture yourself facing the open end of the tub. The door will swing to the right or left as pictured above. Please check the box next to the model number above for the hinged door location you need. Fill out the information below and fax/e-mail this document along with your Proposal back to us. Call us on our 800 number if you have any questions. For multiple units of different configurations write # needed by each check mark. Facility Name: Authorized Purchaser Name: Title: Signature: Date: Page 15 of 16

Page 16 of 16 Gen II Mixing Valve Requirements: The MasterCare Bathing System for safety purposes is supplied with a thermostatic mixing valve that is ASSE 1016-T listed, UPC listed and CSA certified to the most stringent mixing valve safety standards in the industry. To achieve optimum results the valve manufacturer requires 120 o F hot water supply at the valve and 59 o F cold water supply at the valve. These temperatures will achieve a 100 o F blend of water. Note: After installation and before use verify that the cartridge screens are clean. Remove and carefully clean any debris from the screens. If the water heaters temperature is regulated at the source with a tempering valve the hot water temperature by the time it reaches the mixing valve on the bathing system may be inadequate (based on line size, distance water must travel and insulation) corrective options are as follows. Preferred Option: 1. Run a dedicated ¾ hot water line to the tub with 120 o F minimum to 150 o F maximum water temperature at 45 PSI to the high pressure hot water hose connecting to the mixing valve on the tub. Note: MasterCare provides a code approved point of use ASSE 1016-T listed mixing valve to safely regulate the tub and shower temperature in the bathing system. Alternative Options: 1. Adjust the MasterCare Gen II Mixing Valve to compensate for inadequate hot water supply. 2. Order a MasterCare manual mixing valve override knob. This knob will allow for a manual override of the anti-scald thermostatic mixing valve. Note: A signed release exempting MasterCare from liability will be required. 3. Slightly restrict the cold water supply to provide more hot water. 2071 14 th Ave Columbus, NE 68601 800-798-5867 FAX: 402-563-9102 www.mastercarebath.com Form 0000 Rev 0000