ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Similar documents
ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

WHHR Midi & Midi Lite

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

G Installation manual Solitude - dmev unit

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation manual Mori HR

Simply Silent Contour 4 (100mm) Axial Extraction Fan

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Xpelair Simply Silent TM Contour Fan

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation & Operating Instructions

Lo-Carbon Quadra Centrifugal Fan

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent DX150

ISCG90SS _03 ISCG90SS

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Xpelair Simply Silent DX100B

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Silhouette Installation and Wiring Instructions

Xpelair Simply Silent DX100

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

ART cm Island Curved Glass

User and maintenance manual

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Purge Ventilation Unit. Product Manual. ventilation systems TP625

irconcentre.co.uk airooncentre.co.uk

100cm Chimney Hood GB IE

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Box60/ 70/ 90. Box60_70_90 v8

CG60/ 70/ 80/ 90/ 100 SS/BK

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

GB User and maintenance manual

Cooker Hood LA-72-CAN.

Installation & Operating Instructions

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Leonardo 90 Wall Hood

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

HOTLINE:

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Instructions for use

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

SP16. 08/50740/1 (UK) - Issue 1

Lo-Carbon T-series Window & Roof Models

Hamlet 60 & 80 Wall Hood

Contact Details. Please note that some of the contact details on this PDF document may not be current.

User s Information Manual

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

General safety precautions English

EZT90BL Extractor. Installation, Use and Maintenance.

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Air always contains a certain amount of water in the form of vapour. This determines the

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance

Thank you for choosing EnviroVent

Triton Systems Anti-Condensation Products Data Pack

General safety precautions English

General safety precautions English

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Rigoletto 60,90 & 120 Built-In Cupboard Hood

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

Centrifugal extract and condensation control fans

T-60cm-OVEN-SS T-60cm-OVEN-CM T-60cm-OVEN-BL

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

November This product has been reconfigured Please read these instructions

Models: RP-10, RP-15, RP-20. User Manual

General safety precautions English

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

Installation and Wiring Instructions

EVG Extractors. Manual for Installation, Use and Maintenance

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

2200W RADIANT HEATER GVARH350. Instruction Manual

Transcription:

ELIX 1003 Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions 3 speed continuous running SAP Appendix Q Eligible 3 models: - standard - timer - humidity control for all domestic wet rooms for walls or ceilings IPX4

"Elix 1003 - CENTRIFUGAL FANS WITH EC MOTOR INSTALLATION and OPERATING INSTRUCTIONS THIS LEAFLET MUST BE AVAILABLE TO THE USER The product you have purchased is an extractor fan for exhausting directly outside or through longer lengths of ducting (up to 15m) and is suitable for wall or ceiling installation. To ensure optimum operation and guarantee a long life, please read this manual carefully. It explains how to install correctly, use and maintain the product properly. Following these instructions will ensure the reliability of the product and extend its working life. The manufacturer will not be held responsible and will not accept any responsibility for damage caused to persons or things due to improper use with reference to the precautions outlined in this leaflet. The product, constructed using state of the art technology, complies with current standards regarding electrical equipment. It conforms with the EMC 2014/30/EU European Directive regarding radio interference suppression and electro-magnetic compatibility. WARNING: Serious injury or death could result if these instructions are not carefully followed Do not use this product for any purpose other than that for which it was designed. Remove the product from its packaging and make sure that it has not been damaged. If in doubt, contact the supplier, authorised dealer, service centre or manufacturer to check that the product will still operate correctly. Do not attempt to use or repair the product before doing this. Do not leave packing material within the reach of children or unskilled people. To dispose of the packaging and the appliance at the end of its useful life refer to current recycling rules. The use of any electrical product requires compliance with some basic rules which are listed below: - do not touch it with wet or damp parts of the body (e.g hands, feet). - this appliance can be used by children aged 8 years and over, and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance should not be carried out by children without supervision. The product should be connected to the mains electricity supply or electrical outlet only if: - the electrical voltage and frequency correspond to those shown on the rating label. - the capacity of the electricity supply is sufficient to operate the product at its maximum power. - suitable electrical protection is provided for the product to be installed. The electrical supply to which the fan is connected must comply with all existing regulations. All installations must comply with current IEE wiring regulations. Before maintenance or cleaning is carried out, the product must be switched off and disconnected from the mains electricity supply. If a fault, malfunction or anomaly of any type occurs, the fan should be isolated (switching it off and disconnecting it from the mains electricity supply) and advice sought from qualified personnel. Always request original spare parts for repairs If the product needs to be removed, turn off the mains supply circuit-breaker and then disconnect the fan. The fan MUST BE installed as detailed in this leaflet 3

WARNING: Damage could be caused to the product if the installation instructions are not followed. The product should not be used in an ambient temperature higher than 40 C (104 F). The product should not be exposed to atmospheric agents (rain, sun, snow, etc.). The product or its parts should not be placed in water or other liquids. Routine maintenance as described below should be carried out to check the condition of the fan. The air or fumes being extracted must be clean and free from greasy particles, soot, chemical and corrosive agents, flammable or explosive mixtures. The product must be installed by professionally qualified personnel. Incorrect installation can cause damage to people, animals or property, for which the manufacturer cannot be held liable. The product must be connected to the electricity supply via a double pole switch of a suitable size, with contact openings of at least 3 mm. If the electrical supply board (or switching device) is located some distance from the fan a means of local isolation must be provided. To ensure optimum operation, do not block the air intake and exit vents. Any ducting used must be free of blockages, and should be insulated if in an unheated area. The room where the product is operating must have adequate air replacement to ensure maximum effectiveness. If the product is sited in a room containing a fuel burning appliance which is not of the balanced flue type, the installer must ensure that air replace ment is adequate both for the fan and the fuel burning appliance The product must not be used as an activator for water heaters, stoves, etc. The product must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion-powered devices. RANGE Trickle Speed 1-8 lt/sec - 28.8 m³/h Trickle Speed 2-14 lt/sec - 50.4 m³/h ELX1003 - this fan combines the latest technology with energy saving and efficiency. It is a quiet running, 3 speed fan designed to run continuously at a pre-selectable choice of 2 trickle speeds (see jumper switch settings). The user can boost the fan speed to its maximum performance when required by means of the cord or remove the cord and use a remote switch, light switch, PIR sensor or humidistat. If the fan is to be ceiling mounted, the pull-cord switch should be put in the off position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring diagrams. The ELX1003 is SAP Appendix Q Listed ELX1003DT - 3 speed, continuous running fan with delay-on timer and pull cord. The delay-on timer version will run at low speed until the boost speed (speed 2) is activated by means of the cord or, if the cord is removed, by means of a remote switch, light switch, PIR sensor or humidistat. There is a 2 minute delay before the fan starts to run at its high speed - if the boost speed is deactivated before that time lapse, the fan will continue to run at low speed. If the boost speed is activated, the fan will operate at high speed until the boost switch is turned off. After this, the fan will continue at high speed for the length of time set on the timer overrun adjustment, between 0 and 30 mins (see Trimmer Adjustment diagram). After the overrun time has elapsed, the fan will return to the slower speed. 4

ELX1003HDT - 3 speed, continuous running fan. The fan runs continuously at the pre-selected lower speed, and the boost (speed 2) will start to operate automatically when the relative humidity (adjustable between 40% and 90% +/-5% tolerance) reaches the pre-set level and will continue to operate at this speed until the humidity has been dispersed and the adjustable over-run timer (adjustable from 0 to 30 minutes) has completed its cycle. The boost speed can also be activated by as described for model ELX1003DT INSTALLATION 1. Check there is nothing missing in box and remove front cover. 2. Drill hole in wall - allow extra width if using ducting - it is the installer's responsibility to use the appropriate core cutter to obtain the correct hole diameter. 3. Remove circuit board cover. 4. Use fan assembly as template to mark drill holes. 5. Drill 4 x 6mm dia holes. 6. Fit wall plugs. 7/8 Decide whether to have cable access from rear (recessed) or top (surface) of fan - if from top ensure that included grommet is properly fixed. (See dia 8). If cable is to come through rear of fan, fit rubber ring (included). ELX1003DL - 3 speed, continuous running fan with Data Logger. For operation and monitoring of the Data Logger, please refer to separate Data Logger instructions enclosed. (Contact Vectaire Ltd for any further clarification.) 9. Screw fan to wall. 10. Connect cable using cable clamp - SEE WIRING DIAGRAMS FOR SPECIFIC MODELS NB this fan is double insulated and does not need to be earthed 11. Before replacing circuit board cover choose speed of fan and set delay-on timer (if applicable) SEE JUMPER SWITCH SETTINGS BELOW 12. Replace front cover. N.B This fan is NOT suitable for use with a Gravity Grille. It should be installed using either a Cowl or Fixed Grille. IMPORTANT If the fan is installed in a ceiling with a vertical duct passing through an unheated space, a condensation trap MUST be fitted. Any ducting in an unheated space should also be insulated according to the latest Building Regulations recommendations in the Domestic Ventilation Compliance Guide. Failure to do this could result in condensation affecting the operation of the fan and cause damage to the ceiling. 5 If the fan is to be ceiling mounted, the pull-cord switch should be put in the off position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring diagrams.

INSTALLATION 1 2 3 4 5 6 6

INSTALLATION 7 8 9 10 7

INSTALLATION 11 12 WIRING DIAGRAMS ELXs - 3 Speed with Cord ELXs - 3 Speed via remote switch N.B When installing fans via a remote switch, pullcord switch must be left in "off" position and the cord removed. 8

JUMPER SWITCH These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the jumper switch. 12 ELX1003 Minimum Speed Jumper 1 13 ELX1003 Speed 2 Jumper 2 14 ELX1003DT ELX1003HDT Minimum Speed Jumpers 1 and 3. To DISABLE delay-on timer remove Jumper 3 15 ELX1003DT ELX1003HDT Speed 2 Jumpers 2 and 3. To DISABLE delay-on timer remove Jumper 3 TRIMMER ADJUSTMENT To adjust the humidistat and timer trimmers, remove the front cover and circuit board cover of the fan to access the trimmers. The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise to decrease sensitivity and set at a higher level of relative humidity. The timer (TM) is adjustable between 0 and 30 minutes. Turn the trimmer clockwise to increase the overrun time, or anti-clockwise to decrease it. 9

MAINTENANCE Before any maintenance or cleaning operation, switch off the fan and disconnect it from the main power supply. The filter can be easily removed and carefully washed. The front cover can be cleaned with a dry cloth or soft brush. The fan must not come into contact with any kind of liquid or solvent. If this should occur, contact a qualified technician before reassembling the fan. NOTE: The motor does not require lubrication as it is maintenance free "sealed for life" type. DISMANTLING & RECYCLING This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. 10

Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk Vectaire Ltd reserves the right to alter specifications as part of its policy of continuous development Elix 1003 190717 E & O.E Cod. 5F12245: Rev.1