Australian Journal of Basic and Applied Sciences. Leak Detection in MDPE Gas Pipeline using Dual-Tree Complex Wavelet Transform

Similar documents
A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS

RLDS - Remote LEAK DETECTION SYSTEM

Shortcut Model for Predicting Refrigeration Cycle Performance

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

Long-range Ultrasonic Non-destructive Testing of Fuel Tanks

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

1066. A self-adaptive alarm method for tool condition monitoring based on Parzen window estimation

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

DETECTION AND LOCALIZATION OF MICRO-LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

An experimental study of the impact of tunnel suppression on tunnel ventilation

Australian Journal of Basic and Applied Sciences. Homogenous Fish Cracker Dryer Using Hybrid Control System

1441. Quantification of the flow noise in household refrigerators

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

AN10943 Decoding DTMF tones using M3 DSP library FFT function

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

This paper will discuss the leak detection technologies that have been adapted to detect thefts and secure accurate tapping point locations.

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

REVIEW ON CONDENSER AIR LEAK TEST

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

A study of Transient Performance of A Cascade Heat Pump System

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

6 th Pipeline Technology Conference 2011

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-11, November- 2016]

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Indoor Air of a Double-Storey Residential House in Malaysia

Preliminary Exploration: Fault Diagnosis of the Circulating-water Heat Exchangers based on Sound Sensor and Non-destructive Testing Technique

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas

ISO/TS TECHNICAL SPECIFICATION

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

REDUCTION OF NOISE AND VIBRATION OF FRONT LOADING WASHING MACHINE IN SPIN-CYCLE

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Keywords: ECM, suction tool, auxiliary electrode, current density, machining characteristics

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Related Problems in Ultrasonic Detection of Porcelain Insulator

Modified Everitt-Jennings (MEJ) Method and the Gibbs Method: Downhole Card Comparison

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Dynamic Models of a Home Refrigerator

Digitization For Long-Distance Oil Pipeline Leakage Detection. Liang Wei China University of Petroleum, Beijing

Department of MCE, Islamic University of Technology 2. Abstract

Fire Detection Using Image Processing

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Leak Detection and Water Loss Control. Maine Water Utilities September 9, 2010

Brine Generation Study

A Novel Online Cleaning System for Shell and Tube Oil Heat Exchanger

A Study of Drying Uniformity in a New Design of Tray Dryer

PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Video Smoke Detection using Deep Domain Adaptation Enhanced with Synthetic Smoke Images

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

CFD Analysis of Fire Characteristics on Subway Junction Station

EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA

AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

AIRFLOW STUDY OF A SPILT-TYPE OUTDOOR UNIT SUBJECTED TO NEAR WALL EFFECT USING COMPUTATIONAL FLUID DYNAMIC (CFD) SIMULATION

Music Sculptures of Glass and Gold

中国科技论文在线 Energy Conversion and Management 52 (2011)

Australian Journal of Basic and Applied Sciences

COST REDUCTION OF SECTION CHANNEL BY VALUE ENGINEERING

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

DUAL MODE PULSE REFLECTOMETRY

Analysis of Eccentric Wear of Sucker Rod and Design of Multi-Stage Flexibility Stabilizer

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Transcription:

AENSI Journals Australian Journal of Basic and Applied Sciences ISSN:1991-8178 Journal home page: www.ajbasweb.com Leak Detection in MDPE Gas Pipeline using Dual-Tree Complex Wavelet Transform Nurul Fatiehah Adnan, Mohd. Fairusham Ghazali, Makeen Amin, Abdul Malik, Akmal Ariffin Faculty of Mechanical Engineering, University Malaysia Pahang, 26600, Pekan, Pahang, Malaysia A R T I C L E I N F O Article history: Received 15 September 2014 Accepted 5 October 2014 Available online 25 October 2014 Keywords: Leak detection; gas pipeline; acoustic; dual tree; cepstrum A B S T R A C T Background: The pipeline system plays the important role in the industry and commonly use as media transport in the piping field on the land or on the sea as well. They are buried underground or situated in the wall of the buildings. The maintenance should be done properly to avoid any leakage to the surrounding. Therefore, the detection of the leak detection is the main investigation issue in order to get the fast and reliable leak detection method. Even though the reasons for these leaks are very well known, some of the current method is quite complicated and not precise. In addition, it is all about time consuming and cost of installment. In this paper, we proposed a leak detection method using acoustic. The chirp signal injected into the pipeline system and the estimation of the leak location from the delay time passing by the reflection in the pipeline if there have a leak. Using Dual Tree Complex Wavelet Transform, the signal filtered and decomposed into five levels. Then, the cepstrum analysis was used to detect the echoes for leak location estimation. When a leak occurred, the new peak shows and identified the presence in the pipeline network. The leak detected at a certain point and the error in this experiment is 0.62 % for leak location and 1.24 % for the outlet., which is nearly accurate to the original leak position. The DTCWT and ceptrum analysis could give acceptable result and possible to identify leaks that are difficult to find by other method. 2014 AENSI Publisher All rights reserved. To Cite This Article: Nurul Fatiehah Adnan, Mohd. Fairusham Ghazali, Makeen Amin, Abdul Malik, Akmal Ariffin., Leak Detection in MDPE Gas Pipeline using Dual-Tree Complex Wavelet Transform. Aust. J. Basic & Appl. Sci., 8(15): 356-360, 2014 INTRODUCTION In any application of engineering structure, pipelines are almost the main part to complete the media transport. The pipeline can be used to transfer air, water, oil and other fluids because of their cost and safety. Thus, as the main media transport they should be properly maintained, to avoid leaks. Usually, the leaks occur caused by damage from any accidents. The leaking and location of leaks needs to detect early. Monitoring any leaking is important in order to prevent any losses of fluid in term of cost. In addition, it can prevent any hazard to the surrounding. Different methods are used to investigate the leaking and their location. It includes visual inspections, acoustic emission, and dynamic pressure measurement. This paper proposed a signal processing method which is Dual Tree Complex Wavelet Transform (DTCWT). This signal processing tool analysis mainly decomposed the high frequency in low and high frequency. The cepstrum analysis used to find the echoes in the pipeline and as the main component to calculate the leak location with an equation. Basic Principle Of Acoustic Leak Detection: In air, sound travels by the compression and rarefaction of air molecules in the direction of travel. However, in solids, molecules can support vibrations in other directions, hence, a number of different types of sound waves are possible. When a leak or ruptures occurred in some places, there will be a change in the pressure balance which generated by friction of the gas or fluid with the wall of the pipeline. The reflection can be detected if there have blockage such as hole, junction, crack and ruptures. This reflection is known as a pressure wave that through inside the pipeline at the speed of sound (Lighthill, 1978). Figure 1 shows the concept of the reflection when a leak occurred. The time of reflected wave can be captured by generating pressure wave at certain location together with single remote sensor (Beck, Williamson, Sims, & Stanway, 2001). The low frequency can propagate for along the pipeline while the higher frequency will attenuate faster. Only the low frequency signal plays an important role in the gas pipeline leak detection. So, low frequency is the focus of this study. Corresponding Author: Nurul Fatiehah Adnan, Faculty of Mechanical Engineering, University Malaysia Pahang, 26600, Pekan, Pahang, Malaysia. Tel: 60134748734; E-mail: nfatiehahadnan@yahoo.com.my

357 Nurul Fatiehah Adnan et al, 2014 Fig. 1: Conceptual wave reflections at a leak (Hunaidi & Chu, 1999). Acoustic sensor normally installed outside the pipeline network. The leak generates noise and pick up by these acoustic sensors and the most important thing is to minimize the background noise (Chis & Saguna, 2007; Scott & Barrufet, 2003). The location and size can be determined by using acoustic methods. This method can be used on new as well as on the existing pipe network. The fast and high sensitivity gives advantages in this method compared to others. In addition, this method also offers accurate leak location and low false alarm rate (Meng, Yuxing, Wuchang, & Juntao). But, high background and noise condition will affect the actual leak and also produce a false alarm when the leak is too small (Murvay & Silea, 2012; Scott & Barrufet, 2003; Sivathanu, 2003; Wang, Short, Dawson, & Lennox, 2009). Dual Tree Complex Wavelet Transform: Complex Wavelet Transform (CWT) is the one of the Wavelet Transform (WT) that extend from the Discrete Wavelet Transform (DWT) and generates complex coefficients to obtain real and imaginary parts. It is a two-dimensional wavelet transform which provide multiresolution, sparse representation and useful characterization of the structure of an image. The tree divided into to two parts which are being real tree and imaginary tree (Dewangan & Bhonsle, 2013). Fig. 2: Block diagram for 3 levels of DTCWT. The necessary characteristic part that need to concern are (Dewangan & Bhonsle, 2013):- The low-pass filters in the two trees must differ by half a sample period. Reconstruction filters are the reverse of analysis. All filters are from the same orthonormal set. Tree a filters are the reverse of tree b filters. Both trees have the same frequency response. Experimental Design: The medium density polyethylene (MDPE) pipe was used in this project with length 35.3 m and diameter of 63 mm. MDPE pipe widely uses in gas and water distribution system because of their durability and easy to handle. For experimental process, the natural gas, which is air will be induced in the pipeline as input. The compressor is the main component to force the air to flow in the pipe. The gas will flow in the pipe and the hole

358 Nurul Fatiehah Adnan et al, 2014 that drilled at 14.75 m from the front pipe to simulate leak point. The total length of this MDPE pipe is 35.3 m. The diameter of the hole is 10 mm. For excitation signal, the speaker used in order to give good propagation. The speaker with closed end and sealed together with a waveguide lens to decrease the noise from surrounding. It has made sure to get the useful signal or output of leakage from the hole. The signal acquired from the wave that catch by microphone and then collected in data by DasyLab. The distance between the speaker and the microphone assumed to be negligibly small. Figure 3 shows the basic experimental setup for this study. National Instrument (NI) is the component to collect data and DasyLab is the also known as Data Acquisition System Laboratory to save the data. DasyLab will act as a filter of noise. The NI_DAQ would be synchronized with the transducer and DasyLab using NIDAQ-MX software. The chirp signal injected into the MDPE pipeline with 20-600 Hz as the input signal. The block size set up at 2000 and the sampling rate is 20 KHz. Fig. 3: Basic experiment setup. RESULT AND DISCUSSION The raw data acquire from the Dasylab and analysis in Matlab using DTCWT for filtering method. Figure 4 shows the original signal for leak and no leak for MDPE pipe and then reconstructed. This filtering method applies two types of filter which are raw data filtering used by 1 st level and signal filtering for next level (2 nd level to 5 th level). The first filter called legall and second filter is qshift_32 type. Fig. 4: Original signal and final reconstruction for leak and no leak. The next step is decomposition part which is DTCWT will decompose the signal into high and low frequency. Only low frequency gives useful data for analysis. The decomposition up to 5 th level as shown in Figure 5 and Figure 6. Fig. 5: 1 st level until 3 rd level of reconstruction of leak and no leak.

359 Nurul Fatiehah Adnan et al, 2014 Fig. 6: 4th level until 5 th level of reconstruction of leak and no leak. Fig. 7: Comparison between leak and no leak for ceptrum analysis. Using spectrum analysis, the echoes detected at certain times as shown in Figure 7. The echoes detected at t 1 = 0.084 s and t 2 =0.2048. t 1 represent leak and t 2 is the outlet that clearly detected using cepstrum. As informed, the leak was simulated at 14. 75 m and total length 35.3 m. The distance of the leak can be calculated using the following equation:- (1) where:- s= distance of the leak (m) Δt= change time (s) a=speed of sound (m/s) It is totally worth to mention the speed of sound is 349 m/s when the distance of the leak detected at 14.658 m and outlet at 35.7376 m which is nearly accurate to the experimental parameter which is leak at 14. 75 m and outlet at 35.3 m. The error for leak location is 0.62 % and for the outlet is 1.24 %. The error may caused by additional noise and also lag happen during data was captured. Conclusion: In this paper, a filtering method which is Dual Tree Complex Wavelet Transform was introduced to detect leak from MDPE pipeline. An acoustic method based on pressure wave through a gas pipeline investigated and analyzed using cepstrum analysis to detect the echoes in the pipeline. It is an effective filtering method which can decompose the high frequency and low frequency. The features in the pipeline simulated by hole as the leak. The result shows that the leak detected at 14. 658 m and outlet detected at 35.7376 am which is nearly accurate to the experimental parameter. The error is about 0.62 % for leak and 1.24 % for an outlet. Work is continuing to improve the accuracy and reliability of the method. The experiment should also be tested for longer pipeline and other features such as junctions and ruptures. ACKNOWLEDGEMENT The authors are grateful to the Ministry of Higher Education Malaysia, which supported this research via FRGS Grant RDU 130111.

360 Nurul Fatiehah Adnan et al, 2014 REFERENCES Beck, S.B.M., N.J. Williamson, N.D. Sims, R. Stanway, 2001. Pipeline system identification through crosscorrelation analysis. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 216: 133-142. Chis, T., A. Saguna, 2007. Pipeline leak detection techniques. Annals. Computer Science Series, 5th Tome 1st Fasc., 25-34. Dewangan, S., D. Bhonsle, 2013. Image denoising using dual tree complex wavelet transform. Global Research Analysis, 2(2): 91-93. Hunaidi, O., W.T. Chu, 1999. Acoustical characteristics of leak signals in plastic water distribution pipes. Applied Acoustics, 58(3): 235-254. Lighthill, J., 1978. Wave in fluids. Cambridge: Cambridge University Press. Meng, L., L. Yuxing, W. Wuchang, F. Juntao, 2012. Experimental study on leak detection and location for gas pipeline based on acoustic method. Journal of Loss Prevention in the Process Industries, 25(1): 90-102. Murvay, P.S., I. Silea, 2012. A survey on gas leak detection and localization techniques. Journal of Loss Prevention in the Process Industries, 25(6): 966-973. Scott, S.L., M.A. Barrufet, 2003. Worldwide assessment of industry leak detection capabilities for single & multiphase pipelines: Department of Petroleum Engineering Texas A&M University. Sivathanu, Y., 2003. Natural gas leak detection in pipelines: U.S. Department of Energy, National Energy Technology Laboratory. Wang, X., G. Short, K. Dawson, B. Lennox, 2009. Acoustic reflectometry for gas pipelines monitoring features in gas pipelines using acoustek.