1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Similar documents
1592P01. for liquids in piping DN

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

FSW300 Series Flow Switch

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

Temperature Sensor TRG Original Installation Instructions English

! WARNING. Before using product, read and understand instructions.

Installation, operating and servicing instructions

KOBOLD PSR/PS FLOW SWITCH

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Installation & Operating Instructions

Platen Heater Pad Replacement

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Flow Switches. Series VHS, VKS, VH

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

Eliminator TotalGuard Installation Manual

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Conductivity Electrode LRG Original Installation Instructions English

M7100 Pressure Transducer

Hakki Pilke Raven spare parts manual

Frost Protection Thermostat

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

QRA10... QRA53... QRA55...

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Water level controller and limiter

LC3000 Level Controller Installation and Maintenance Instructions

QRA10... QRA53... QRA55...

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Installation Instructions For Monsoon Universal Twin Pump

Installation and operating instructions. DK energy storage and DK energy buffer

QRA10... QRA53... QRA55...

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

Installation Instructions For Monsoon Universal Twin Pump

OEM Sensors for HVAC manufacturers Pool water

General System Layout Sketch

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER

Standard. thermostatic valve body without presetting

Pump assembly Instruction manual

Level Electrode NRG NRG Original Installation Instructions English

Waste water ejection unit

VERSAFLOW VORTEX Supplementary instructions

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

BASIC SYSTEM LOCATION INDEX

NRG NRG NRG NRG

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

HE360 Humidifier Installation Kit

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

SMK 22 SMK SMK SMK 22-82

IMPORTANT SAFETY INSTRUCTIONS:

esfr dry pendent sprinkler Vk502 (k14.0)

CR Series Command Relays

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Crown Boiler Company

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Instructions for the fan motor control system, SILVER C

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

TECHNICAL DATA. model c-2

A B A B4

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Installation instructions

Flame Safeguards LFE10. Building Technologies HVAC Products

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

HD Kompakt Service Manual

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Mounting and Operating Instructions EB 2231 EN

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

PWC-500/1000/1010/1500

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

MC-100V & BC-100V Operation / Installation Manual

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Operating instructions

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

Transcription:

594 59P0 Flow switch for liquids in piping DN 0 00. QE90 Contact load / switching capacity: Nominal pressure PN5 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free max. AC 30, A, 6 A max. DC 48, A, 0 W Mode of operation Flow monitor of liquid medium in HAC plants in hydraulic systems, in particular, refrigeration, heat pump and heating plants, e.g. for evaporators, boilers, heat exchangers, etc. Ordering When ordering, please provide the name and product number: Flow switch QE90 CMN594en 9.08.008 Building Technologies

Mechanical design Switching value table for water at 0 C The device records the flow of monitored medium via a paddle system (), which has a permanent magnet () attached at its upper end. A reed contact (3) is positioned outside the flow above this magnet. A second magnet (4) with opposite polarity is used to create a reset force. The paddle system moves once it comes into contact with the monitored flow. The magnet () changes its position to the reed contact (3). The contact opens/closes depending on the contact type. As soon as the flow is interrupted, the paddle returns to its original position and the reed contact opens/closes depending on the contact type. (See "Adjusting the switching unit" on page 5) 594G0 594G0 DN Qmax (m3/h) (m 3 /h) Factory setting (m 3 /h) 0 4 0.9. 0.9. 5 5..3..3 3 8.6.9.6.9 40 0.8..8. 50 4.4.7.4.7 80 30 4.7 5. 4.7 5. 00 40 5.8 6.4 5.9 6.4 50 00 4. 5.5 4. 5.5 00 80 9.0 30.0 9.0 30.0 Engineering notes On site, a T-junction /" thread per EN DIN 04 required (steel fittings with threads) and EN DIN 04 (threaded fitting from malleable casting) required All dimensions and data provided in the table of switching values are based on water at 0 C, the use of T-junctions and horizontal piping Before and after the mounting location of the flow switch, a smoothing path of at least 0 times or 5 times respectively the nominal pipe diameter required /7

Flow switch installation Mechanical installation General installation instructions When choosing the installation site, ensure that the specified limit values (see "Technical Data" are not exceeded. Select suitable measures to prevent the medium from freezing. If the flow switch is to be used in ambient temperatures of <4 C, do not carry out any operation beforehand using pure water. Residual water in the flow switch can result in frost damage. First, clean the pipe system where the flow switch is installed and remove any magnetic particles, e.g. wielding residue. The smoothing section in front of and behind the flow switch must be at least 0 times or 5 times respectively. The nominal installation position of the flow switch is "upright standing position" in horizontal pipework. The switches should only be installed in a vertical position; deviation max. of 45. Please contact the manufacturer for other installation positions. Please make sure that there are no external magnetic fields in the immediate vicinity of the flow switch, since these can impair device operation. There is an arrow on the flow switch. Ensure during installation that the arrow is parallel with the pipe shaft and is facing in the flow direction. DN0 00 The brass connecting nut G¾ has a tightening torque of 5...30 Nm. Nut size 7 external thread G½A, 4mm Welding nipple with female thread G½ 3/7

Installation notes Observe all local regulations from the electrical utilities or waterworks as applicable Allow for an extra loop of the connecting cable to ensure the switching value can be adjusted Electrical connections General electrical connection information Caution: Danger of death due to electrical voltage! Always de-energize the system before connecting the wires of the mains cable. CAUTION: Ensure that the maximum electrical contact load specified on the type plate is never exceeded; otherwise the reed contact integrated in the switching unit will be damaged. Inductive loads impair switching capacity. Please ask the manufacturer for information on protective circuits. Elbow plug connector EN 7530-803-A Fig. Fig. Fig. 3 Fig. 4 Loosen the central screw (pos. 6) M3x35 and disconnect the junction box EN 7530-803-A (pos. ) from the connector (pos., Fig. ). Use a screwdriver or similar tool to press out the core (pos. 8) of the junction box (Fig. ). Loosen the screw connection PG 9 (pos. 5, Fig. 3). Feed the connecting cable into the junction box via the screw connection (pos. 5), the clamping ring (pos. 0) and the rubber insert (pos. 9) and subsequently connect the wires as displayed in the connection diagram (see Fig. 4). not occupied Press the core (pos. 8) until it locks into position in the junction box (pos. ). Tighten the cable gland PG 9 (pos. 5). 4/7

Place the junction box (pos. ) on the connector (pos. ) and retighten the central screw (pos. 6). To guarantee the protection class IP 65 per EN 6059, the applied connecting cable has to have a sheathing diameter of between 4.5 and 7 mm. Furthermore, ensure that all the connector seals (pos. 3, 4 and 9) have been correctly inserted. Adjust switching unit Standard contact The switching unit of the control switch enables contact types:. Make contact (normally open): RED arrow on the switching unit. Break contact (normally closed): WHITE arrow on the switching unit The following table explains the two contact types: Contact type Setting Flow rate Electric contact increasing closing Make contact (NO) RED arrow decreasing opening Break contact (NC) WHITE or BLUE arrow increasing decreasing opening closing Unless otherwise agreed to with the customer, the switching unit is factory set to make contact, i.e. opens if the set switching point is exceeded. In order to adjust the switching unit, open the cover of the switching head Subsequently loosen the locking screw (.5 hexagon socket screw) and position the switching unit until the red or white arrow are visible at the entry of the switching contact guide for a desired make contact or break contact respectively. You can use the arrow length to make fine adjustments to the switching point: Adjust to the arrowhead means: Switching point is at a lower flow rate. Adjust to the arrow end: Switching point is at a higher flow rate. Carefully retighten the locking screw. We recommend you to use lacquer/thread locker to secure the locking screw of the switching unit after carrying out individual adjustments. Close the cover until it locks into place. high flow rate low flow rate setting range high flow rate low flow rate setting range The switching unit does not need to be adjusted when the customer requests a factory set switching point. 5/7

Technical data Functional data Protective data Environmental conditions Norms and standards Materials / Color Weight Field of use Suitable media All liquids (not suitable for ammonia) Piping diameter DN 0 00 Type of switch Reed contact Contact rating AC 30, A / DC 48, A Max. switching capacity AC 6 A / DC 0 W Switching point adjustment manual, supplied with minimum switch-off value Tolerance of switching point ranges in the table 5 % Setting range See switching value table Medium temp. (medium cannot freeze) -0 0 C Nominal pressure PN 5 Housing IP 65 per EN 60 59 Protection class III per EN 60 730 General environmental conditions Operation and storage -0 80 C Ambient humidity <95 % r.h. conformity to EMC directive 004/08/EEC Low voltage directive 006/95/EEC Product standard EN 6000-6- and EN 6004- Housing Polyamide, black Screw-in body G½" Brass excl. packaging 0.3 kg Maintenance and repair The flow switch is maintenance-free and cannot be repaired by the user. In the unlikely event of a defect, the device has to be returned to the manufacturer for repair. Decommissioning and disposal Never remove a flow switch or its upper parts from a system under pressure. Remove all the electrical connectors and disassemble the flow switch. The flow switch consists of various materials (see Technical data ). Never dispose of the level switch in domestic waste (refer to the crossed out waste bin displayed on the type plate). Return the flow switch to the manufacturer for correct disposal. 6/7

Dimensions Cutting the paddle DN L 3 (mm) 0 40 ± 5 46 ± 3 5 ± 40 6 ± 50 7 ± 80 9 ± 00 ± 50 ± 00 ± DN 40 6 ± DN 3 5 ± DN 5 46 ± DN 0 40 ± 594Z0 9 5 0 30 40 50 60 70 80 DN 50 7 ± DN 80 9 ± DN 00.. DN00 ± Flow switch 74 0 46 38 9 ± G ½ A 9 L3 5 0 30 40 50 60 70 80 594M0 Dimensions in mm 007 Siemens Switerland Ltd Subject to change 7/7