Similar documents
TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Installation and Operation Manual

Solution F2. Fire Alarm Control Panels one step ahead.

System 800 Addressable Fire Detection & Alarm System

TX7004. Intelligent Addressable Fire Alarm Control Panel Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Sita200plus. 200detectors. Single loop analogue addressable System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Intelligent Single Loop Fire Alarm Control Panel

Excel-EN Conventional Fire Control Panel

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Touch Screen 1 loop Addressable Fire Alarm Panel

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Consultant Specification AGILE Wireless Fire Detection System

TX7004. Intelligent Addressable Fire Alarm Control Panel Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Intelligent Addressable Fire Alarm System

The EN54 Part 2 & 4 Fire System

FireNET Plus Wiring Instructions

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Addressable and Conventional Fire Protection

GST Headquarters. GST Production Base

Installation, Operating and Maintenance Manual

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

CODESEC FIRE ALARM SYSTEMS. security technologies

Advanced FireAlarm Panel 1-4Loop

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

INPUT / OUTPUT MINI MODULES

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Solution F1. Fire Control Panels the new generation

INTELLIGENT FIRE ALARM CONTROL PANEL

intelligent fire alarm ID60series panels

Intelligent Security & Fire Ltd

Conventional Fire Alarm System 2014 V1.2

DS7400Xi Addressable Control/ Communicator

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SUPREMATouch. Modular Fire & Gas Detection System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

YOUR PARTNER IN FIRE & GAS DETECTION

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Vigilant MX4428 Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ZXSe Range Data Sheet

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Specification/ Data Sheet

The EN54 Part 2, 4 and 13 Fire System

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Control Panel Engineering and Commissioning Instructions

Our technology, your peace-of-mind. Product list

SUPREMATouch. Modular Fire & Gas Detection System

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Fire Alarm System. The Intelligent Solution. Leading global technology Safe guarding lives and properties

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Addressable Fire Alarm Control System 2100 series

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

Flair 500 Series Annunciators

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

TABLE OF CONTENTS. 1. Intelligent Light 1.1 Intelligent Corridor Light 1.2 Intelligent Down Light

2017 Fire Alarm Systems Product catalogue

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

The EN54 Part 2 and 4 Fire System

FC700A Fire detection control unit

30.45 Electric Release PDRP-2001

Intelligent Security & Fire Ltd

The supplier and installer of the system should be approved by the local civil defence authority.

An introduction to... Sigma

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Reliably Advanced Extinguishing Control

MINERVA MX. 800 Series Ancillary Equipment

ACP10 & ACP50 Security Systems

2000 Series Sensors Installation Guide

Laptop / PC Programming Manual

SUPREMATouch Modular Fire & Gas Detection System

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Wireless Fire & Security Solutions. Fire Product Showcase

Addressable Fire Alarm Control Panel

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Transcription:

Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity Memory [Non-Volatile]: Zones: Total group: Sounder group: Common group: EN54-2 & EN54-4 100VAC to 240 VAC 50/60Hz 1A 24VDC 2x12V/28AH, rechargeable-lead acid type battery Class A, can bus [loop], panel to panel 3kms Up to 512 USB, RS485 serial, RS232 serial, ethernet 1000 Fire events, 10,000 general event 3,000 Programmable 3,000 Programmable 1,000 Programmable 2,000 Programmable Loop specifications No. of loop: Protection: Power rating: Cabling: Up to 4 loops class A Built-in 4kV surge protection 24Vdc Output / 120Ma 1.0km Max length / 2x1.5mm² solid core fire resistance TX7004 Panel input / outputs Programmable relays: Programmable input: Programmable auxiliary power: Fixed outputs: 4 Circuits: normally open / close 1 Circuit: power limited 24Vdc (for future use) Power limited 24VDC 2 Circuits: power limited 24Vdc Display: Keypad: Material / Color: Dimension L x W x H: 24 LED Status / 160 Zone indicators 7 TFT Touch screen 5 Brigade buttons and programming keypad Flat sheet metal / with outer glass door, orange 530 mm x 490 mm x 135 mm 16.70 kg Graphic monitor system Color graphic control and display system, provide a complete window on the fire detection systems and ancillary equipment. Compatible with LPCB approved intelligent fire panels Multi-level password control for convenient system management PC not included 01

Intelligent addressable somke detector TX7100 Using microprocessor technology with memory capacity up to 10 events Analogue sending and digital addressing Provide real time algorithm to the control panel Smart linear drift compensation 360 degree visual indicator Removable chamber against dust and small insect Ancillary remote indicator output Sensitivity: EN54-7 Standby: 0.6mA / Alarm: 4mA As per stipulated standard Single LED / 360 Degree visual Diameter 99.7 mm / 57 mm 145g (with base), 90g (without base) Intelligent heat detector EN54-5 Compliance Using microprocessor technology with memory capacity up to 10 events Analogue sensor and digital addressing Provide real time algorithm to the control panel 360 degree visual indicator Ancillary remote indicator output TX7110 Sensitivity: EN54-7 Standby: 0.6mA / Alarm: 4mA Type A1R Single LED / 360 Degree visual Diameter 99.7 mm / 57 mm 127g (with base), 72g (without base) 02

Addressable manual call point TX7140 EN54-11 Compliance Using microprocessor technology Digital addressing Non-breakable glass and hammerless Safe to operate and easy to reset Surface mounted, indoor application Dimension: Class: EN54-11 Standby: 0.6mA / Alarm: 1.8mA Single LED / Steady on-when pressed ABS / Red glossy finishing 85 mm x 93 mm x 35 mm 102g (with base), 80g (without base) Type A, indoors -10 C to +55 C IP43 Addressable sounder and strobe EN54-3 Compliance Built-in MCU processor and digital addressing 17 Tones programmable sound output Programmable types such as sounder-strobe, sounder or strobe alone Programmable evacuate or pre-alarm / evacuate signal Low and normal consumption mode One or two addresses mode 10 Highlights LED status cluster s Loop or external power input Universal mounting with fix base for simple installation 03 TX7300 Typical current: Loop and external PSU: Saving current: Address sequence: Strobe light: Class: EN54-3 Loop power: 24VDC (18V to 27.5V) External PSU: 24 VDC (20V to 27.5V) Loop: Standby: 0.6mA / Alarm: 1.5mA External PSU: Standby: 0.6mA / Alarm: 15mA Standby: 1.2mA / Alarm: 9mA Single address: evacuate tone Dual address: 1st alert tone / 2nd evacuate tone 10 Highlights LED ABS / Red glossy finishing Diameter 110 mm / 39.6 (with base) 176g (with base), 110g (without base) Type A, indoors IP21

Addressable single input / output module TX7210 Isolator module EN54-18 Compliance Built-in MCU processor and digital addressing 24Vdc/2A Output relay contact and control module Input fire or supervisory signal configuration LED status indicator Loop or external power input Surface mounting with fix base for simple installation Control output voltage: Input relay Input resistance: Indicator status: Dimension / LWH: EN54-18 Loop power: External PSU: 20 to 28VDC Loop: Standby: 0.6mA / Alarm: 1.6mA External PSU: Standby 0.6mA / Alarm: 45mA 24VDC / 2A rating Normally open dry contact 5.1Kohms/ ¼ W Normal: single blink / Active: steady / Fault: double blink 108 mm x 86 mm x 38 mm 170g (with base), 92g (without base) IP30 EN54-17 Compliance In the event of a short circuit isolates faulty parts of the loop. Automatically resetting once the fault has cleared Can monitor up to 70 devices LED status indicator Loop powered device Surface mounting with fix base for simple installat TX7230 Protocol TNA Number of monitored: Output impedance: Indicator status: Dimension / LWH: EN54-17 Standby: 0.15mA / Alarm: 1.8mA Max 70 devices 480 ohms Normal: single blink / Active: steady-on 108 mm x 86 mm x 38 mm 152g (with base), 81g (without base) 04

Conventional reflective beam detector EN54-12 Compliance Hassle free alignment, built with digital guide display and laser beam pointing Employ single-ended design through reflective mirror Four ranges wide monitoring from 8-100 meters via encoder Three users programing sensitivity adjustment Built-in microprocessor Self-diagnosis function can monitor for internal faults Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter Fire and Fault interfacing relays Attractive and pleasing appearance Real User friendly alignment method EN54-12 TX7130 Operating voltage: Current parameters: Beam sensor sensitivity (via encoder): Length beam pathway (via encoder): Beam path angle: Alignment guide: Digital display guide: LED indicator guide: Reset time: Relay capacity (fire & fault): Dimension / Weight: DC20 V to 28V Standby: 23mA / Commission: 56m / Alarm: 33mA Level 1: 2.6 db high sensitivity Level 2: 3.8 db medium sensitivity Level 3: 5.8 db low sensitivity Span 1: 8 to 20 meters limited path Span 2: 20 to 40 meters short path Span 3: 40 to 70 meters normal path Span 4: 70 to 100 meters long path ±0.4º Directional Laser beam pointer Nixie tube Red: fire Yellow: fault Green: alignment Less than 2 second Normally open & close/ 2.0 A, 30 VDC ABS / White L: 190.87 x W: 126.87 x H: 91.96 mm / 440 gm 0.130kg with base IP30 (IP66 glue seal For permanent fixing) Detector base TX7980 Common base for termination and fixing of detectors, compatible for TX7100 and TX7110. Non-electronic component 05