K4RH(X) Solids-Handling Pumps

Similar documents
K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

KEENER GRINDER PUMPS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

HOMA Pump, Ansonia Connecticut

Goulds HSU, HSUL & JCU. Submersible Pumps

- Sewage and Sludge Pumps

SUBMERSIBLE SOLIDS HANDLING PUMPS Features and Benefits:

Reliable Long-Term Solutions For Your Toughest Pump

brands you trust. The Next Generation of SH Series Pumps BARNES SH SERIES PUMPS

FLANGE-MOUNT CENTRIFUGAL PUMPS

Pump Installation and Service Manual SPX50/SPX50H Submersible Explosion-Proof Pumps

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Full-line Product Overview

SUBMERSIBLE SOLIDS HANDLING PUMPS

Series 4XSHV 18 Frame Driver 76mm Spherical Solids Handling

SECTION STEAM CONDENSATE PUMPS

SECTION WASTEWATER PUMPING STATION DESCRIPTION

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Industrial. Solutions brands you trust. Product Overview

The Next Generation of

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

PUMPS AND CONTROLS. Submittal #1 Pumps. Project Torrance Memorial Medical Center Storm Lift Sation Project #

Submersible and Immersible Pumps

Electric Submersible Pumps

POULTRY MARKET CATALOG

Electric Submersible Pumps

MARLOW PUMPS RECIRCULATION

Company name: Created by: Phone:

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CORNELL PUMP COMPANY MINE DEWATERING WHEN RELIABILITY MATTERS

CLOSED COUPLED CENTRIFUGAL PUMPS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Vertical Heavy Duty Pumps

INDUSTRIAL AND MARINE PUMPING SOLUTIONS

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

5. CONDENSATE PUMPS/UNITS

OTHER BJM PRODUCTS SUBMERSIBLE PUMP CAPABILITIES PERFECTA SERIES SLIDE RAILS CONTROL PANELS. THE RIGHT PUMP FOR TOUGH JOBS

SL EX.4.51D

Flygt N-pumps 3231, 3306, 3312, 3356, 3400

OTHER BJM PRODUCTS SUBMERSIBLE PUMP CAPABILITIES. PERFECTA SERIES SLIDE RAILS CONTROL PANELS THE RIGHT PUMP FOR TOUGH JOBS

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

GSZ/GSD HIGH VOLUME DEWATERING PUMPS

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

380 Series Multi-Stage Centrifugal Pumps

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

380 Series Multi-Stage Centrifugal Pumps

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

PENGUIN SERIES HSC PUMPS INTRODUCTION

NJWEA TECH TRANSFER MARCH 1, 2016

DESCRIPTION IMPELLER INSPECTION MAINTENANCE POWER CORD REPLACEMENT IMPELLER REPLACEMENT MECHANICAL SEAL REPLACEMENT IMPELLER INSPECTION /REPLACEMENT

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Flygt centrifugal grinder pumps

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

CR A-F-A-E-HQQE 3x400/ HZ

471 US Hwy 250 East, Ashland, Ohio PH: FX:

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

CR A-F-A-E-HQQE 3x400/ HZ

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

CR20-07 A-F-A-E-HQQE 3x400/ HZ

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

KTV DEWATERING PUMPS

INTRODUCTION 09/'16 SUPSD 06/'15

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Machine Tool Coolant Units

Wilo IL Vertical Split-Coupled Inline Pumps

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SL S.S.N.51D

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Ampco s Complete Line of AC SERIES PUMPS AC, AC+, IC+

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

Pumps SELECTION OF A PUMP

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 3HP THRU 10HP CENTRIFUGAL SUBMERSIBLE GRINDER SEWAGE PUMPS

TYPE POS Oil Shield Sump Pump

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Specially Designed Waste Water & Sewage Pumps

Dean Pump High Temperature Chemical Process Inline Pumps

MODELS 4RH/4RHX*, 4VHA/4VHAX*, 4VH/4VHX*, 4VHS/4VHSX* and 6VH/6VHX* *Used in Hazardous Locations Class I, Division 1, Groups C & D

LHW HIGH HEAD DRAINAGE PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

Transcription:

Solids-Handling Pumps K4RH(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location) RECESSED IMPELLER Handles Stringy and Fibrous Materials Passes Large Solids Pumps Heavier Solids Concentrations Ideal for Grit and Abrasive Solids Pumping via Vortex Action Solids Do Not Pass through Impeller Virtually Impossible to Clog STRONG PERFORMANCE Ideal for Higher heads, Lower flows Operate to Shut-off Head without Damage Non-overloading Performance Curve LONG SERVICE LIFE Dual Silicon Carbide Shaft Seals Low Motor Operation Temperatures Continuously Lubricated Bearings Premium 3-Bearing Construction Epoxy Potted Cord Entry LOW MAINTENANCE No Wear Components Recessed Impeller out of Passageway Grit-Resistant Silicon Carbide Shaft Seals CAPABILITIES: Flows-------------------------------------- to 540 GPM Heads------------------------------------- to 94 Feet HP Range-------------------------------- 7.5-15 HP Voltage / Phase Options------------- 208/230 V, 1 Phase - 208/230/460 V, 3 Phase Discharge Connections-------------- 4 ANSI Class 125 Horizontal Flange Motor Speeds--------------------------- 3450 RPM Solids-Handling------------------------ 3 Impeller---------------------------------- Recessed, Vortex Motor Service Factor----------------- 1.20 Rev. 03/2018

Features and Benefits 1. Watertight Cable Entrance Heavy-duty molded compression grommet protects outer cord jacket. *Explosion-proof cable entrance option provides agencyapproved, watertight strain relief cord grips with compression grommets to protect outer cord jacket. Epoxy-filled inner cord cap provides anti-wicking moisture protection to the motor even if power cable is cut or damaged. 40 UL power & control cords. K4RH(X) 1 2. Modular Pump Design Commonality of parts across the Keen product line minimizes the amount of parts required for servicing. Heavy-duty ASTM A48, Class 35 cast iron components. 2 3. Strong Motor Powerful high-torque motor for reliable pump operation. Pressed stator securely holds motor and efficiently transfers heat to cast housing. Class F insulation with overload protection in oil-filled chamber for cool operation and long motor life. 3a. Oil Proprietary Keen oil ensures industry-low operating temperatures. 4. 3-Bearing Support Motor / Pump shaft securely held with upper and lower ball bearing plus additional sleeve bearing in lower seal chamber. Long 50,000 hour B-10 bearing life. 5. Severe Duty Dual Mechanical Seals Dual silicon carbide mechanical shaft seals provide twice the moisture and grit protection for the motor. Dual seals are housed in a secondary oil-filled seal chamber. Tougher silicon carbide seals better handle sand, grit and abrasive materials. 6. Moisture Detection Seal leak probe signals alarm in control panel for scheduled maintenance. 3 6 4 5 7. Non-Overloading Hydraulic Design Recessed centrifugal impeller allows 100% performance curve operation from shut-off to maximum flow without damage to the pump or system. The recessed, vortex impeller is out of the passageway of fluid flow, eliminating concerns of blockage or wear. 8. 3 Solids-Handling Clear, unobstructed passageway provides reliable movement of solids. 9. Standard Flange Connection 4 Horizontal, Class 125 ANSI discharge flange. Industry standard, 8-bolt pattern. 7 8 9 Rev. 03/2018 471 US HWY 250 East. Ashland, Ohio 44805 419.207.9400 fax 419.207.8031 www.keenpump.com

DIMENSIONAL DATA 5-3/16 4-3/8 4-1/4 7-1/2 36 29-1/2 2-5/16 5-5/16 Note: All dimensions in inches unless noted. Dimensions may vary due to normal manufacturing tolerances. File: K4RH Dimensions

LIFTOUT DIMENSIONAL DATA Notes: 1. All dimensions in inches unless noted. 2. Discharge flange ANSI Class 125 unless noted. 3. Absolute minimum and recommended minimum submergence levels noted. 4. Discharge base elbow must be placed above sump bottom as noted. 5. Dimensions may vary due to normal manufacturing tolerances. 6. If discharge pipe is larger than discharge elbow, eccentric reducer must be used limited to 2X larger maximum. File: K4RH Liftout Dimensions

SIMPLEX INSTALLATION DIMENSIONAL DATA Notes: 1. All dimensions in inches unless noted. 2. Refer to pump dimension and liftout dimension sheets for more details. 3. Recommended minimum submergence levels noted. 4. Discharge base elbow must be placed above sump bottom as noted. 5. Dimensions may vary due to normal manufacturing tolerances. 6. If discharge pipe is larger than discharge elbow, eccentric reducer must be used limited to 2X larger maximum. File: K4RH Install Dimensions

DUPLEX INSTALLATION DIMENSIONAL DATA Notes: 1. All dimensions in inches unless noted. 2. Refer to pump dimension and liftout dimension sheets for more details. 3. Recommended minimum submergence levels noted. 4. Discharge base elbow must be placed above sump bottom as noted. 5. Dimensions may vary due to normal manufacturing tolerances. 6. If discharge pipe is larger than discharge elbow, eccentric reducer must be used limited to 2X larger maximum. File: K4RH Install Dimensions