Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Similar documents
Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Searchpoint Optima Plus

SPM Flex Chemcassette Tape-Based Gas Detector

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Searchpoint Optima Plus

Honeywell Analytics. Order List BW Clip & IntelliDoX

MeshGuard and MeshGuard Gamma

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Operating Instructions

XNX Universal Transmitter

MeshGuard and MeshGuard Gamma

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Operating Instructions

Sensepoint XCL Fixed Gas Detector

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

XNX Universal Transmitter

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Touchpoint Pro Flexible Gas Control System

Gas Detection. Touchpoint Plus. A whole new control experience

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Life Safety Network. Intelligent solutions for advanced requirements

Dräger GS01 (wireless) Detection of flammable gases and vapours

System 57. An advanced World of intelligent gas detection system management

XNX Universal Transmitter

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Touchpoint Plus. A whole new control experience

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

GS01 (wireless) Detection of flammable gases and vapours

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Operating Instructions and Maintenance Manual

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

Senscient s team has more than 150 years collective experience in gas. detection.

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Dräger Flame 2500 (IR3) Flame Detection

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

EC FX NH3. A new and improved approach to ammonia gas detection

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

System 57. An advanced world of intelligent gas detection system management

Zareba Sensepoint Pro

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Sieger Apex. Flexibility that meets your requirements

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

OMA-300 Process Analyzer

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

BP Alaska GC-1. Design Review Project. January 2003

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Flame Detection Jon Sarfas

PREMIER PLATINUM INFRARED GAS SENSOR

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Flame 5000 Flame Detection

Dräger Flame 2500 Flame Detection

ADPRO PRO Series by Xtralis

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Technical data sheet TDS0034

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

GAS PLUS ALARM SYSTEM

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Flame 2100 (UV) Flame Detection

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Sieger fixed gas detection. Fixed protection from hazardous gas

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Transcription:

Searchline Excel The Searchline Excel is the World s best selling infrared open path gas detector

Searchline Excel Applications include Offshore platforms & vessels (FPSO s) Downstream chemical processing plants Gas transport and pipelines Large storage areas & buildings Perimeter detection Features and Benefits Double band pass filters that fully compensate for all types of fog, rain and/mist interference 100% Solar Immune Correct operation under partial obscuration conditions High vibration resilience Radially symmetrical and bonded window heating delivers good low temperature performance Coaxial optics delivers best in class performance and resilience to partial obscuration Fully temperature compensated solid state detectors Low power consumption in all conditions Simple lock on alignment tool No extra software alignment required Higher power and more robust design telescope Optional Modbus RS485 multi drop output FM hazardous area and performance approved The Searchline Excel is the World s best selling infrared open path gas detector with over 25,000 units installed in challenging applications throughout industry. From the Arctic Circle to middle eastern deserts, customers have repeatedly selected the Searchline Excel as their preferred choice. Product Evolution pioneered the original design of open path infrared flammable gas detectors with the introduction of the original Searchline back in 1987. Since then we have continued to work in conjunction with major international oil and gas companies to fully understand the demanding application requirements of these systems. In 1998 we introduced Searchline Excel which has become the industry standard for open path gas detection by meeting and exceeding all customer driven demands. With continuous improvement and the highest quality manufacturing and control processes, Searchline Excel Open Path flammable gas detector provides best in class gas detection. Excel is often the chosen primary flammable gas detector in conjunction with Searchpoint Optima Plus as complimenting flammable point detection. Why open path gas detection? Open path detectors complement the use of individual point detectors and offer many significant benefits including: Reliable flammable gas detection, proven in use Wider area coverage - most likely to pick up any leak Very high speed of response Failsafe - no unrevealed failure modes - no possibility of blocked gas path to detector Detector location not as critical Indicates size of hazard Simple set up and commission Replaces multiple point devices Gas leak missed by point detectors but picked up by Open Path Detector Pipeline Point Detectors Open Path Detector

Searchline Excel The Difference The patented optical design used in Searchline Excel has proven itself as the only solution available that fully addresses all the challenges of open path flammable gas detection. Unlike some competitive devices, it does not try to hide fundamental design inadequacy with the use of software masks that can compromise the unit s ability to detect gas. Searchline Excel employs a patented double band pass filter that fully compensates for all types of fog and / or rain, thereby allowing it to continue to operate accurately and reliably in all climatic conditions. Different fog types scatter/absorb differently Fog type 1 Fog type 2 Upscale gas/ false alarm S R S R Downscale gas/fault R - reference wavelength S - sample wavelength The solution... double band pass filter Fog type 1 Fog type 2 R S R R S R R - reference wavelengths S - sample wavelength The differential scatter and absorption has a linear effect with respect to the reference wavelengths. The output from the reference detector is the average between the reference bands and will be exactly the same as the sample wavelength. Searchline Excel was the first open path gas detector in the world to have achieved performance approval by FM. Radially symmetrical heating elements bonded to transmitter and receiver windows. The unique coaxial design of the optics also means that Searchline Excel is also the only open path gas detector that can operate correctly under partial obscuration conditions without the possibility of generating a false alarm. Non-coaxial instruments potentially suffer from differential attenuation that can lead to false alarms. Products or services that meet FM Approvals rigorous testing standards may bear the FM APPROVED mark, a visual symbol of excellence that is widely recognised and respected. This Mark of Excellence tells customers that a company s product conforms to the highest standards and will continue to meet those standards. Additional FM tests With its patented double band pass filter and unique coaxial optical design, Searchline Excel was the first open path gas detector that fully addresses the issues of performance under partial obscuration and fog/mist conditions. As these elements were not covered in the FM standard, our optical engineers worked alongside FM to develop and approve Searchline Excel to a new set of simulated fog/mist and partial obscuration tests.

Searchline Excel Sample and reference detector alignment Reduced sensitivity to alignment Guaranteed performance Reduced sensitivity to partial obscuration Intuitive hand-held software Simple confirmation of alignment Visual indication of target and current signal levels Compatible with existing systems The fundamental design of Searchline Excel has remained the same since its original launch and it continues to lead the field. Other manufacturers have tried unsuccessfully to develop comparable instruments but none have the experience or technology that is utilised in Searchline Excel. Having introduced open path flammable gas detection built upon the excellence of the Searchpoint Optima Plus optimal point gas detectors, has continued to develop the Searchline Excel system. This open path flammable gas detector has become the standard within the oil and gas and petrochemical industries, meeting the exacting demands of our customers. The addition of the XNX Universal Transmitter provides local display and enhanced interfacing options such as relays and modern digital communications including HART, Modbus and Foundation Fieldbus. Accurate alignment tools Simple to use, accurate alignment tools High-power telescope Easier to align with greater zoom and magnification Robust shock resistant design True Alignment System A good installation is key to obtaining the best performance from an open path gas detection system. Optimum alignment of the transmitter and receiver will ensure the best performance of the system in the harshest climatic conditions. A visual check of the path using a telescope is required to ensure that there are no physical obstructions in the beam. With the True Alignment System used on Searchline Excel this alignment is so accurate that the requirement for further adjustment using a software based alignment tool is eliminated. Unique, proven telescope mounting mechanism Simple engagement and locking mechanism 3 point mounting datum ensures true alignment Sight can be angled to most convenient position So accurate that further software guided adjustments not required

Solar Immune Searchline Excel is totally immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning. This is achieved by using a xenon flash lamp that is actually brighter than the sun at the infrared detection wavelengths and solid state detectors with a wide dynamic range. The lamp is also modulated to have a unique pulse duration and shape. The receiver then uses high speed digital signal processing to validate that all the signals received have this unique signature and rejects any extraneous signals. Accessories 1. Deluge shield / sunshade 2. True alignment system 3. Gassing cell 4. Hand-held interrogator 5. Optical gas test filters 6. SHC protection device 1 3 2 6 4 5

Modbus Digital Output Modbus digital output - know before you go! Searchline Excel is also available as a kit with the XNX Universal Transmitter, featuring both a local HART port and HART over 4 to 20mA as standard. These solutions allow configuration of the Searchline Excel through the XNX user interface or using a compatible HART hand-held interrogator 1 device. Alternatively, an intrusive connection to the Searchline Excel using an SHC-1 handheld interrogator together with an SHC-1 protection device module can be made in applications that allow such operations. The multi drop Modbus capability can enable significant savings in installation and cabling costs. A single comms cable can be run between up to 32 detectors instead of the usual single run required for each detector. Additionally, the 2 way digital communication protocol allows configuration, warning and fault diagnosis information to be communicated back to the control room. This reduces servicing and maintenance costs as the operator can diagnose the state of any individual unit before deciding to send anyone into the field. Installation options Options 1 2 3 Hazardous Area Safe Area Hazardous Area Safe Area Hazardous Area Safe Area Power XNX Universal Transmitter 4-20mA Controller 4-20mA Controller Modbus DCS/PLC 4-20mA DX100 (M) UL/CSA/FM approved Modbus SCADA OTB122 Junction box Searchline Excel/Junction box/ Controller 4-20mA output to Controller Local intrusive interrogation via SHC and Hand-held Interrogator Lowest cost Searchline Excel/XNX Universal Transmitter or DX100(M) Controller Redundant 4-20mA signals to Controller or HART (XNX) Optional remote status via Modbus to SCADA Local non intrusive interrogation (DX100 (M) or local non-intrusive interrogation with HART (XNX) Searchline Excel/DX100M or XNX Universal Transmitter (Modbus)/ DCS or PLC Multi drop Modbus output Remote status to DCS/PLC Local non intrusive interrogation Cabling cost savings

Technical Summary Searchline Excel Specification Available Gases Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Butadiene Range Recommended Alarm Settings Path Lengths Speed of Response Output Signal Digital Output Operating Temperature 0 to 5 LEL.m (Low) 1.0 LEL.m; (high) 3.0 LEL.m Short Range 5m to 40m (15ft to 130ft.), Medium Range 40m to 120m (130ft to 390ft.) and Long Range 120m to 200m (390ft to 650ft.) T90 less than 3 seconds. (under normal operating conditions) 4-20mA (maximum loop resistance 600 ohms; source & sink available) and RS485 21mA Over range 4-20mA Normal operation (0 to 5 LEL.m) 3mA (1) Dirty optics 2.5mA (1) Beam blocked 2mA (1) 0mA Fault Modbus RS485 multi drop. Using DX100 (M) or XNX Universal Transmitter with Modbus option -40 C to +65 C (-40 F to 150 F) Operating Humidity 0 to 99% RH (non-condensing) Operating Pressure Warm-up Time Power Supply Power Consumption Enclosure Material Weight (inc. mounting bracket) Vibration 91.5 to 105.5 KPa (915 to 1055 mbar) (non-compensated) Less than 5 minutes (operational), or less than 1 hour (fully stabilised) 18V to 32VDC Short Range Tx: 3.5W / 5.0W *maximum. Medium and Long Range Tx: 10W / 13W* maximum. Rx: 8W maximum. 316 stainless steel Short Range TX: 3.5kg Medium and Long Range TX: 7kg RX: 3.5kg 2 to 60Hz, max ptp amplitude 1mm. Misalignment Tolerance Short Range ±0.5º (±~35cm at 40m). Medium Range ±0.5º (±~104cm at 120m). Long Range ±0.5º (±~170cm at 200m) EMC Standards Performance Approval EN50270 FM performance approved Safety Approval ATEX Transmitter: II 2 G Ex d op is IIC T5 (Tamb -40 C to +65 C) Gb II 2 G Ex d op is IIC T6 (Tamb -40 C to +40 C) Gb Receiver: II 2 G Ex d IIC T5 (Tamb -40 C to +65 C) Gb II 2 G Ex d IIC T6 (Tamb -40 C to +40 C) Gb IECEx Transmitter: Ex d op is IIC T5 (Tamb =-40 C to +65 C) Gb Ex d op is IIC T6 (Tamb =-40 C to +40 C) Gb Receiver: Ex d IIC T5 (Tamb -40 C to +65 C) Gb Ex d IIC T6 (Tamb -40 C to +40 C) Gb UL: Class 1 Groups B, C, D and Class 1 Zone 1 AEx d IIB + Hydrogen (Amb -40 C to +65 C) CSA: Class 1 Div 1 groups B, C, D, T5 and Exd IIC T5 (Amb -40 C to +65 C) FM: Class 1 Div 1 groups B, C, D & T5 (T amb -40 to +65 C) Other: GOST Independently assessed to IEC61508 IP Rating IP66 and IP67 (1) User programmable. * Turboheating activated (standard feature; user selectable). This is recommended for the most severe weather conditions. Tx / Rx = 80mm Tx / Rx = 185mm Tx = 137mm Rx = 80mm Tx = 235mm Rx = 185mm Short Range 5m to 40m (15ft to 130ft) Medium Range 40m to 120m (130ft to 390ft) and Long Range 120m to 200m (390ft to 650ft)

Gas Detection is able to provide gas detection solutions to meet the requirements of all applications and industries. Contact us in the following ways: Headquarters Europe, Middle East, Africa Life Safety Distribution AG Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Customer Service: Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Fax: 00800 333 222 55 Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Middle East Tel: +971 4 450 5852 (Portable Gas Detection) Americas Distribution Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com Asia Pacific Asia Pacific #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 (0) 2 6909 0300 Fax: +82 (0) 2 2025 0388 India Tel: +91 124 4752700 analytics.ap@honeywell.com Technical Support Centres Ltd. 4 Stinsford Road Nuffield Industrial Estate Poole, Dorset, BH17 0RZ United Kingdom Tel: +44 (0) 1202 645 544 Fax: +44 (0) 1202 645 555 ZAC Athélia 4-375 avenue du Mistral Bât B, Espace Mistral 13600 La Ciotat France Tel: +33 (0) 4 42 98 17 75 Fax : +33 (0) 4 42 71 97 05 Elsenheimerstrasse 43 80687 München Germany Tel: +49 89 791 92 20 Fax: +49 89 791 92 43 P.O. Box-45595 6th Street Musaffah Industrial Area Abu Dhabi UAE Tel: +971 2 554 6672 Fax: +971 2 554 6672 EMEA: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com www.honeywellanalytics.com www.raesystems.com Experts in Gas Detection Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. 11256_H_Searchline Excel_IR_DS0282_V8_EMEA 02/15 2015